870 resultados para Medical instruments and apparatus
Resumo:
We present the first comprehensive intercomparison of currently available satellite ozone climatologies in the upper troposphere/lower stratosphere (UTLS) (300–70 hPa) as part of the Stratosphere-troposphere Processes and their Role in Climate (SPARC) Data Initiative. The Tropospheric Emission Spectrometer (TES) instrument is the only nadir-viewing instrument in this initiative, as well as the only instrument with a focus on tropospheric composition. We apply the TES observational operator to ozone climatologies from the more highly vertically resolved limb-viewing instruments. This minimizes the impact of differences in vertical resolution among the instruments and allows identification of systematic differences in the large-scale structure and variability of UTLS ozone. We find that the climatologies from most of the limb-viewing instruments show positive differences (ranging from 5 to 75%) with respect to TES in the tropical UTLS, and comparison to a “zonal mean” ozonesonde climatology indicates that these differences likely represent a positive bias for p ≤ 100 hPa. In the extratropics, there is good agreement among the climatologies regarding the timing and magnitude of the ozone seasonal cycle (differences in the peak-to-peak amplitude of <15%) when the TES observational operator is applied, as well as very consistent midlatitude interannual variability. The discrepancies in ozone temporal variability are larger in the tropics, with differences between the data sets of up to 55% in the seasonal cycle amplitude. However, the differences among the climatologies are everywhere much smaller than the range produced by current chemistry-climate models, indicating that the multiple-instrument ensemble is useful for quantitatively evaluating these models.
Resumo:
Historians of medicine, childhood, and paediatrics, have often assumed that early modern doctors neither treated children, nor adapted their medicines to suit the peculiar temperaments of the young. Through an examination of medical textbooks and doctors’ casebooks, this article refutes these assumptions. It argues that medical authors and practising doctors regularly treated children, and were careful to tailor their remedies to complement the distinctive constitutions of children. Thus, this article proposes that a concept of ‘children’s physic’ existed in early modern England: this term refers to the notion that children were physiologically distinct, requiring special medical care. Children’s physic was rooted in the ancient traditions of Hippocratic and Galenic medicine: it was the child’s humoral makeup that underpinned all medical ideas about children’s bodies, minds, diseases, and treatments. Children abounded in the humour blood, which made them humid and weak, and in need of medicines of a particularly gentle nature.
Resumo:
Background: Studies evaluating acceptability of simplified follow-up after medical abortion have focused on high-resource or urban settings where telephones, road connections, and modes of transport are available and where women have formal education. Objective: To investigate women's acceptability of home-assessment of abortion and whether acceptability of medical abortion differs by in-clinic or home-assessment of abortion outcome in a low-resource setting in India. Design: Secondary outcome of a randomised, controlled, non-inferiority trial. Setting Outpatient primary health care clinics in rural and urban Rajasthan, India. Population: Women were eligible if they sought abortion with a gestation up to 9 weeks, lived within defined study area and agreed to follow-up. Women were ineligible if they had known contraindications to medical abortion, haemoglobin < 85mg/l and were below 18 years. Methods: Abortion outcome assessment through routine clinic follow-up by a doctor was compared with home-assessment using a low-sensitivity pregnancy test and a pictorial instruction sheet. A computerized random number generator generated the randomisation sequence (1: 1) in blocks of six. Research assistants randomly allocated eligible women who opted for medical abortion (mifepristone and misoprostol), using opaque sealed envelopes. Blinding during outcome assessment was not possible. Main outcome measures: Women's acceptability of home-assessment was measured as future preference of follow-up. Overall satisfaction, expectations, and comparison with previous abortion experiences were compared between study groups. Results: 731 women were randomized to the clinic follow-up group (n = 353) or home-assessment group (n = 378). 623 (85%) women were successfully followed up, of those 597 (96%) were satisfied and 592 (95%) found the abortion better or as expected, with no difference between study groups. The majority, 355 (57%) women, preferred home-assessment in the event of a future abortion. Significantly more women, 284 (82%), in the home-assessment group preferred home-assessment in the future, as compared with 188 (70%) of women in the clinic follow-up group, who preferred clinic follow-up in the future (p < 0.001). Conclusion: Home-assessment is highly acceptable among women in low-resource, and rural, settings. The choice to follow-up an early medical abortion according to women's preference should be offered to foster women's reproductive autonomy.
Resumo:
Frequent advances in medical technologies have brought fonh many innovative treatments that allow medical teams to treal many patients with grave illness and serious trauma who would have died only a few years earlier. These changes have given some patients a second chance at life, but for others. these new treatments have merely prolonged their dying. Instead of dying relatively painlessly, these unfortunate patients often suffer from painful tenninal illnesses or exist in a comatose state that robs them of their dignity, since they cannot survive without advanced and often dehumanizing forms of treatment. Due to many of these concerns, euthanasia has become a central issue in medical ethics. Additionally, the debate is impacted by those who believe that patients have the right make choices about the method and timing of their deaths. Euthanasia is defined as a deliberate act by a physician to hasten the death of a patient, whether through active methods such as an injection of morphine, or through the withdrawal of advanced forms of medical care, for reasons of mercy because of a medical condition that they have. This study explores the question of whether euthanasia is an ethical practice and, as determined by ethical theories and professional codes of ethics, whether the physician is allowed to provide the means to give the patient a path to a "good death," rather than one filled with physical and mental suffering. The paper also asks if there is a relevant moral difference between the active and passive forms of euthanasia and seeks to define requirements to ensure fully voluntary decision making through an evaluation of the factors necessary to produce fully informed consent. Additionally, the proper treatments for patients who suffer from painful terminal illnesses, those who exist in persistent vegetative states and infants born with many diverse medical problems are examined. The ultimate conclusions that are reached in the paper are that euthanasia is an ethical practice in certain specific circumstances for patients who have a very low quality of life due to pain, illness or serious mental deficits as a result of irreversible coma, persistent vegetative state or end-stage clinical dementia. This is defended by the fact that the rights of the patient to determine his or her own fate and to autonomously decide the way that he or she dies are paramount to all other factors in decisions of life and death. There are also circumstances where decisions can be made by health care teams in conjunction with the family to hasten the deaths of incompetent patients when continued existence is clearly not in their best interest, as is the case of infants who are born with serious physical anomalies, who are either 'born dying' or have no prospect for a life that is of a reasonable quality. I have rejected the distinction between active and passive methods of euthanasia and have instead chosen to focus on the intentions of the treating physician and the voluntary nature of the patient's request. When applied in equivalent circumstances, active and passive methods of euthanasia produce the same effects, and if the choice to hasten the death of the patient is ethical, then the use of either method can be accepted. The use of active methods of euthanasia and active forms of withdrawal of life support, such as the removal of a respirator are both conscious decisions to end the life of the patient and both bring death within a short period of time. It is false to maintain a distinction that believes that one is active killing. whereas the other form only allows nature to take it's course. Both are conscious choices to hasten the patient's death and should be evaluated as such. Additionally, through an examination of the Hippocratic Oath, and statements made by the American Medical Association and the American College of physicians, it can be shown that the ideals that the medical profession maintains and the respect for the interests of the patient that it holds allows the physician to give aid to patients who wish to choose death as an alternative to continued suffering. The physician is also allowed to and in some circumstances, is morally required, to help dying patients whether through active or passive forms of euthanasia or through assisted suicide. Euthanasia is a difficult topic to think about, but in the end, we should support the choice that respects the patient's autonomous choice or clear best interest and the respect that we have for their dignity and personal worth.
Resumo:
OBJETIVO: Verificar a frequência de problemas médicos autorrelatados e a frequência de áreas de dor no corpo em pacientes com dor orofacial, comparando-os a pacientes submetidos a tratamento odontológico de rotina. MÉTODOS: Os dados foram coletados dos arquivos da Clínica de Dor Orofacial (Grupo A, n=319) e de clínicas de tratamento odontológico rotineiro (Grupo B, n=84) da Faculdade de Odontologia de Araraquara, São Paulo, Brasil. Os indivíduos responderam a questionários e preencheram um mapa corporal indicando os locais de dor. RESULTADOS: O teste de Mann-Whitney demonstrou que o Grupo A apresentou uma média de relatos de problemas médicos superior ao Grupo B (p=0,004). Para ambos os grupos, o teste de correlação de Pearson demonstrou correlação positiva entre os problemas médicos e a frequência de áreas dolorosas (respectivamente, 0,478, p=0,001 e 0,246, p=0,000). CONCLUSÕES: O Grupo A relatou maior número de problemas médicos e houve correlação positiva entre a frequência desses problemas e a de áreas de dor para ambos os grupos.
Resumo:
Includes bibliography
Resumo:
This study evaluated the efficacy of 2 types of rotary instruments employed in association with sodium hypochlorite (NaOCl) or EDTA in removing calcium hydroxide (CH) residues from root canals dentin walls. Forty-two mandibular human incisors were instrumented with the ProTaper System up to F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA and filled with a CH intracanal dressing. After 7 days, the CH dressing was removed using 4 techniques: NiTi rotary instrument size 25, 0.06 taper (K3 Endo) and irrigation with 17% EDTA (Group 1), NiTi rotary F1 instrument (ProTaper) and irrigation with 17% EDTA (Group 2), NiTi rotary instrument size 25, 0.06 taper and irrigation with 2.5% NaOCl (Group 3) and NiTi rotary F1 instrument and irrigation with 2.5% NaOCl (Group 4). Two roots without intracanal dressing were used as negative controls. Teeth were evaluated by scanning electron microscopy, in the cervical and apical canal thirds. None of the techniques removed the CH dressing completely. In the apical and cervical thirds, F1 instrument was better than instrument size 25, 0.06 taper in removing CH residues (p<0.05), regardless of the final irrigating solution. No difference was found between the irrigating solutions in the groups of F1 instrument and of instrument size 25, 0.06 taper (p>0.05). The negative controls had no CH residues on the dentin walls. In conclusion, the ProTaper F1 instrument was better than K3 Endo instrument size 25, 0.06 taper in the removal of CH intracanal medication, regardless of irrigating solution used.
Resumo:
Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.
Resumo:
Due to shortage of time and limited availability of faculty surgeons to teach basic surgical skills during medical graduation, the search for alternative ways of simulated training with feedback is needed. The purpose of this study was to compare the simulated teaching of suture skills to novice medical students by senior medical students and by experienced faculty surgeons. Forty-eight novice medical students were randomly assigned to three practice conditions on bench model (n = 16): self-directed suture training (control), senior medical student-directed suture skills' training, or experienced faculty surgeon-directed suture skills' training. Pre- and post-tests were applied. Global Rating Scale with blinded evaluation and self-perceived confidence based on Likert scale were used to assess all suture performances in pre- and post-training. Effect size was also calculated. The analysis made after training showed that the students who received feedback from the instructors had better performance based on the Global Rating Scale (all p < 0.0000) and felt more confident to carry out sutures (all p < 0.0000) when compared to the control. There was no significant difference (all p > 0.05) between the student-directed teaching and faculty-directed teaching groups. The magnitude of the effect (instructor-directed training suture) was considered large (>0.80) in all measurements. The acquisition of suture skills after student-directed training was similar to the training supervised by faculty surgeon, and the increase in suture performances of trainees that received instructor administered training was superior to self-directed learning. © 2013 Springer-Verlag Italia.