973 resultados para Medical device industry


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Shape memory NiTi alloys have been used extensively for medical device applications such as orthopedic, dental, vascular and cardiovascular devices on account of their unique shape memory effect (SME) and super-elasticity (SE). Laser welding is found to be the most suitable method used to fabricate NiTi-based medical components. However, the performance of laser-welded NiTi alloys under corrosive environments is not fully understood and a specific focus on understanding the corrosion fatigue behaviour is not evident in the literature. This study reveals a comparison of corrosion fatigue behaviour of laser-welded and bare NiTi alloys using bending rotation fatigue (BRF) test which was integrated with a specifically designed corrosion cell. The testing environment was Hanks’ solution (simulated body fluid) at 37.5oC. Electrochemical impedance spectroscopic (EIS) measurement was carried out to monitor the change of corrosion resistance at different periods during the BRF test. Experiments indicate that the laser-welded NiTi alloy would be more susceptible to the corrosion fatigue attack than the bare NiTi alloy. This finding can serve as a benchmark for the product designers and engineers to determine the factor of safety of NiTi medical devices fabricated using laser welding.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Induction of in vivo responses by implanted biomaterials is of great interest in the medical device field. Calcium phosphate bone cements (CPCs) can potentially promote natural bone remodelling and ingrowth in vivo and, as such are becoming more common place in a range of orthopaedic procedures. However, concerns remain regarding their mechanical and handling properties. Compressive modulus and fracture toughness of CPCs can be improved, without compromising injectability and setting time, through the incorporation of bovine collagen fibres1. Incorporation of marine derived collagen fibres has also yielded similar improvements2. It is hypothesised that, due to its role in bone formation and function, that incorporation of collagen in CPCs will also result in biological benefits.
The biological properties of α-TCP-CPC were largely unchanged by the incorporation of marine derived collagen. However, as a result of significant improvements to the mechanical properties, its incorporation may still result in a suitable alternative to some commercially available bone cements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Enquadramento: O ‘Physiosensing’ (‘PhyS’) é um dispositivo médico destinado ao treino do controlo postural nas posições de sentado e de pé, bem como no levantar e sentar, possibilitando também a avaliação do desempenho a este nível. Este trabalho teve como objetivo avaliar a fiabilidade e a validade da plataforma ‘Physiosensing’ na avaliação do equilíbrio em pessoas com deficiência intelectual (PCDI). Métodos: Para o grupo experimental (GE) foram recrutados 47 indivíduos com deficiência intelectual e para o grupo de controlo (GC) 39 indivíduos sem deficiência intelectual, provenientes da região do BaixoMondego. A avaliação da fiabilidade incluiu as análises da concordância entre observadores, reprodutibilidade temporal e consistência interna. A análise fatorial exploratória analisou os pressupostos de subdomínios propostos pelos autores. A validade discriminante foi analisada através da comparação de resultados entre o GE e o GC, e a validade concorrente pela análise dos valores de associação entre os resultados do ‘PhyS’ com a Escala de Equilíbrio de Berg (EEB). Resultados: O subconjunto de exercícios relacionados com a transferência de peso lateralmente (TPL) apresentou os resultados mais elevados a nível da concordância entre observadores (0,40 ≤ CCI > 0,75) e na reprodutibilidade intemporal (CCI ≥ 0,75). O instrumento apresenta uma consistência interna fraca (α = 0,63) quando considerados todos os exercícios, tendo-se obtido o melhor resultado para o subconjunto de exercícios TPL (α = 0,81). A análise fatorial exploratória devolveu quatro fatores, explicando 76,4% da variância, agrupando no primeiro fator o subconjunto de exercícios TPL. Foram encontradas diferenças estatisticamente significativas entre os resultados dos participantes com e sem deficiência intelectual, em dez dos onze exercícios que compõem a configuração da plataforma. Seis exercícios, que incluem os exercícios TPL, apresentam valores de associação estatisticamente significativos com a EEB. Conclusão: Alguns exercícios da plataforma ‘PhyS’ não se mostram adequados para medir o equilíbrio em PCDI, não podendo ser incluídos numa medida global. No entanto, os exercícios TPL poderão constituir um indicador global do equilíbrio em pessoas com PCDI. Recomenda-se a definição de procedimentos de medição de forma a melhorar os índices de fiabilidade, o aprofundamento da configuração de exercícios para a avaliação do equilíbrio e o estudo do potencial da plataforma em programas de intervenção para o treino das funções do equilíbrio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Com o crescente aumento da Teleradiologia, sentiu-se necessidade de criar mais e melhores softwares para sustentar esse crescimento. O presente trabalho pretende abordar a temática da certificação de software e a sua marcação CE, pois para dar entrada no mercado Europeu todos os Dispositivos Médicos (DM) têm de estar devidamente certificados. Para efetuar a marcação CE e a certificação serão estudadas normas e normativos adequados para marcação de DM ao nível Europeu e também dos Estados Unidos da América. A temática da segurança de dados pessoais será também estudada de forma a assegurar que o dispositivo respeite a legislação em vigor. Este estudo tem como finalidade a certificação de um software proprietário da efficientia sysPACS, um serviço online abrangente, que permite a gestão integrada do armazenamento e distribuição de imagens médicas para apoio ao diagnóstico.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As formulações de cloreto de sódio 0,9%, são na sua grande maioria utilizadas com bastante frequência sobretudo na população pediátrica. Tanto os cuidadores como os próprios profissionais de saúde as reconhecem e avaliam como um componente essencial para os cuidados de saúde desta população. No entanto, o grave problema destas formulações reside no facto de muitos dos consumidores após a sua utilização apresentarem reacções adversas, que não são justificáveis se apenas da composição da formulação fizerem parte água purificada e cloreto de sódio. Assim deve ser tida em conta a composição de cada apresentação farmacêutica, a fim de se averiguar quanto à presença de conservantes potencialmente perigosos e para deste modo alertar os possíveis consumidores destes produtos. O principal objectivo deste estudo foi a análise e avaliação da rotulagem e folheto de instruções das formulações de cloreto de sódio 0,9% para aplicação tópica em pediatria, a fim de se averiguar a utilização de conservantes na sua formulação e por conseguinte a sua conformidade para comercialização. Com o auxílio de uma check-list, foram avaliadas 34 apresentações de venda livre de formulações de cloreto de sódio 0,9% para aplicação tópica, no período de Janeiro a Março de 2014. Das 34 apresentações farmacêuticas analisadas, apenas uma dasapresentações não se encontrava descrita como dispositivo médico, mas sim como produto cosmético. Contudo quanto à marcação CE de conformidade, esta encontrava-se devidamente aposta em 94% das apresentações. No que às indicações terapêuticas diz respeito e como seria expectável, na sua maioria estas apresentações destinam-se em 51% dos casos para utilização nasal e em 33% dos casos para utilização oftálmica, sendo o modo de apresentação em gotas (88%) o mais encontrado para comercialização. Quanto à utilização de conservantes, constatou-se uma grande omissão e alguma imprecisão quanto às informações contidas na rotulagem e/ou folheto de instruções das formulações analisadas, expondo assim os indivíduos mais susceptíveis e em especial a população pediátrica ao risco de reacções adversas e que por vezes podem ser fatais. Por outro lado também podem ocorrer complicações aquando do uso inadvertido destasformulações com conservantes, por portadores de lentes de contacto ou sem a devida esterilidade para utilização oftálmica. Assim apesar de o soro fisiológico não ser considerado um medicamento, mas sim um dispositivo médico, deve ser contudo utilizado com algumas precauções, sobretudo nesta população pediátrica e sempre que possível aconselhado por um profissional treinado e consciente da problemática que os conservantes usados nestas formulações podem causar quando utilizados indevidamente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação apresentada ao Instituto Superior de Administração e Contabilidade do Porto para obtenção do Grau de Mestre em Logística Orientada por: Professora Doutora Maria Clara Rodrigues Bento Vaz Fernandes

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La littérature abordant les enjeux socio-éthiques et réglementaires associés aux médicaments est relativement abondante, ce qui n’est pas le cas des dispositifs médicaux (DM). Ce dernier secteur couvre une très large diversité de produits qui servent à de multiples applications: diagnostic, traitement, gestion des symptômes de certaines conditions physiques ou psychiatriques, restauration d’une fonction débilitante, chirurgie, etc. À tort, on a tendance à croire que les DM sont réglementés de la même manière que les médicaments, que ce soit pour les exigences concernant leur mise en marché ou des pratiques de surveillance après mise en marché. Or, au cours des dernières années, leur usage élargi, leur impact sur les coûts des soins de santé, et les rappels majeurs dont certains ont fait l’objet ont commencé à inquiéter la communauté médicale et de nombreux chercheurs. Ils interpellent les autorités réglementaires à exercer une plus grande vigilance tant au niveau de l’évaluation des nouveaux DM à risque élevé avant leur mise en marché, que dans les pratiques de surveillance après mise en marché. Une stratégie plus rigoureuse d’évaluation des nouveaux DM permettrait d’assurer un meilleur suivi des risques associés à leur utilisation, de saisir la portée des divers enjeux socio-éthiques découlant de l’utilisation de certains DM, et de préserver la confiance du public. D’emblée, il faut savoir que les autorités nationales n’ont pas pour mandat d’évaluer la portée des enjeux socio-éthiques, ou encore les coûts des DM qui font l’objet d’une demande de mise en marché. Cette évaluation est essentiellement basée sur une analyse des rapports risques-bénéfices générés par l’usage du DM pour une indication donnée. L’évaluation des impacts socio-éthiques et l’analyse coûts-bénéfices relèvent des agences d’Évaluation des technologies de santé (ÉTS). Notre recherche montre que les DM sont non seulement peu fréquemment évalués par les agences d’ÉTS, mais l’examen des enjeux socio-éthiques est trop souvent encore incomplet. En fait, les recommandations des rapports d’ÉTS sont surtout fondées sur une analyse coûts-bénéfices. Or, le secteur des DM à risque élevé est particulièrement problématique. Plusieurs sont non seulement porteurs de risques pour les patients, mais leur utilisation élargie comporte des impacts importants pour les systèmes de santé. Nous croyons que le Principisme, au cœur de l’éthique biomédicale, que ce soit au plan de l’éthique de la recherche que de l’éthique clinique, constitue un outil pour faciliter la reconnaissance et l’examen, particulièrement par les agences d’ÉTS, des enjeux socio-éthiques en jeu au niveau des DM à risque élevé. Également, le Principe de Précaution pourrait aussi servir d’outil, particulièrement au sein des agences nationales de réglementation, pour mieux cerner, reconnaître, analyser et gérer les risques associés à l’évaluation et l’utilisation de ce type de DM. Le Principisme et le Principe de Précaution pourraient servir de repères 1) pour définir les mesures nécessaires pour éliminer les lacunes observées dans pratiques associées aux processus de réglementation, et 2) pour mieux cerner et documenter les enjeux socio-éthiques spécifiques aux DM à risque élevé.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivo del estudio: comparar las mediciones realizadas en el dispositivo de entrega de agente halogenado, con un modelo matemático donde se encontraron los valores ideales de fracción espirada de agente halogenado para cada evento. Diseño del estudio: diseño de tecnología. Lugar de desarrollo: salas de cirugía de un Hospital Universitario, Bogotá, Colombia. Intervenciones y medidas: luego de diseñar y ensamblar un circuito anestésico semiabierto tipo mascara facial con dos válvulas unidireccionales (una inspitratoria y otra espiratoria), se procedió a tomar las medidas de Concentración inspirada de sevofluorane, y fracción inspirada de oxigeno, con volúmenes espiratorios de 70 a 170 mL con intervalos de 10 mL, y con el dial de sevoflorane a 2, 2.2, 2.4, 2.6 vol%, los resultados consignados fueron comparados con los valores matemáticamente calculados para cada evento. Resultados: las mediciones realizadas en la máscara son concordantes con los cálculos realizados en el modelo matemático. La concentración espirada de sevoflorane es ligeramente superior en cada evento con respecto a lo encontrado en el modelo matemático, no es posible asegurar la no reinhalación con las mediciones realizadas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and Objective: Dispensing medicines into compliance aids is a common practice in pharmacy contrary to manufacturers’ advice and studies have shown the appearance of light-sensitive tablets is compromised by such storage; we previously found evidence of reduced bioavailability at elevated temperature and humidity. Our objective was to examine the physicochemical stability of two generic atenolol tablets in different compliance aids and with aspirin co-storage at room temperature and at 40 °C/75% relative humidity. Methods: The physicochemical stability of atenolol tablets was evaluated after 28 days of storage and compared with controls by examining visual appearance, weight, disintegration, dissolution, friability and hardness to accepted standards and using a previously validated HPLC method for chemical assay. Results and Discussion: The response to storage was brand-dependent and not straightforward. With one make of atenolol (Alpharma), storage in compliance aids even at room temperature impacted on physical stability, reducing tablet hardness, with storage in Dosett® exerting a greater impact than storage in Medidos® (t-test P < 0·001). Co-storage at elevated temperature and humidity also impacted on the appearance of non-coated aspirin tablets (Angette™). The chemical stability of atenolol was not affected and we did not find evidence of changes to bioavailability with either make. Certainly data for one atenolol make (CP Pharmaceuticals) co-stored with aspirin (Angette™ and Nu-Seals) in both compliance aids at room temperature provided evidence of short-term stability. But medicines are dispensed into compliance aids in multi-factorial ways so our study highlights not only the lack of evidence but also a realization that evidence to support real practice may not be accomplished through research. Conclusion: Reassuring practitioners of the continued stability of medicines in compliance aids under the countless condition in which they are dispensed in practice may requires a different approach involving medical device regulators and more definitive professional guidance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nasogastric tubes are a commonly used medical device. There are numerous complications associated with their use, one of the most significant is when they are inadvertently inserted into the cranium. Clinicians need to be aware of this complication and the type of patient who is most susceptible.


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nasogastric tubes are a medical device that can be used for a number of purposes. The process of inserting them however can be complicated. Nurses must therefore use an evidence based approach to confirm the correct position of nasogastric tubes and there are three main techniques described in the literature to do so. To date, one group of authors has published the majority of the studies on these techniques. This paper reviews their work.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective : To document the types of, and mortality from, Staphylococcus aureus bacteraemia in Australia and New Zealand, and determine factors associated with mortality.

Design and setting : Prospective observational study in 27 independent or hospital pathology laboratories in Australia (24) and New Zealand (3), employing a web-based database to prospectively record demographic features, selected risk factors, principal antibiotic treatment and mortality data on all patients with positive blood cultures for S. aureus from June 2007 to May 2008.

Main outcome measure : 30-day all-cause mortality.

Results : 1994 episodes of S. aureus bacteraemia were identified, and complete 30-day follow-up data were available for 1865. Most episodes had their onset in the community (60.8%; 95% CI, 58.7%–63.0%). Methicillin-resistant S. aureus (MRSA) caused 450 episodes (24.1%; 95% CI, 22.2%–25.9%), and 123 of these (27.3%) had a susceptibility profile consistent with community-associated MRSA. All-cause mortality at 30 days was 20.6% (95% CI, 18.8%–22.5%). On univariate analysis, increased mortality was significantly associated with older age, European ethnicity, MRSA infection, infections not originating from a medical device, sepsis syndrome, pneumonia/empyema, and treatment with a glycopeptide or other non-β-lactam antibiotic. On multivariable analysis, independent predictors of mortality were age, sepsis syndrome, pneumonia/empyema, device-associated infection with a secondary focus, left-sided endocarditis, and treatment with a glycopeptide such as vancomycin, but not MRSA infection.

Conclusions : S. aureus bacteraemia is a common infection in both the community and hospitals in Australia and New Zealand, and is associated with appreciable mortality. Invasive MRSA infection may be more life-threatening, partly because of the inferior efficacy of the standard treatment, vancomycin. National web-based surveillance of S. aureus bacteraemia and its outcomes is not only important but also easily achievable.