967 resultados para MICELLAR ELECTROKINETIC CHROMATOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comprehensive two-dimensional gas chromatography (GC×GC) offers enhanced separation efficiency, reliability in qualitative and quantitative analysis, capability to detect low quantities, and information on the whole sample and its components. These features are essential in the analysis of complex samples, in which the number of compounds may be large or the analytes of interest are present at trace level. This study involved the development of instrumentation, data analysis programs and methodologies for GC×GC and their application in studies on qualitative and quantitative aspects of GC×GC analysis. Environmental samples were used as model samples. Instrumental development comprised the construction of three versions of a semi-rotating cryogenic modulator in which modulation was based on two-step cryogenic trapping with continuously flowing carbon dioxide as coolant. Two-step trapping was achieved by rotating the nozzle spraying the carbon dioxide with a motor. The fastest rotation and highest modulation frequency were achieved with a permanent magnetic motor, and modulation was most accurate when the motor was controlled with a microcontroller containing a quartz crystal. Heated wire resistors were unnecessary for the desorption step when liquid carbon dioxide was used as coolant. With use of the modulators developed in this study, the narrowest peaks were 75 ms at base. Three data analysis programs were developed allowing basic, comparison and identification operations. Basic operations enabled the visualisation of two-dimensional plots and the determination of retention times, peak heights and volumes. The overlaying feature in the comparison program allowed easy comparison of 2D plots. An automated identification procedure based on mass spectra and retention parameters allowed the qualitative analysis of data obtained by GC×GC and time-of-flight mass spectrometry. In the methodological development, sample preparation (extraction and clean-up) and GC×GC methods were developed for the analysis of atmospheric aerosol and sediment samples. Dynamic sonication assisted extraction was well suited for atmospheric aerosols collected on a filter. A clean-up procedure utilising normal phase liquid chromatography with ultra violet detection worked well in the removal of aliphatic hydrocarbons from a sediment extract. GC×GC with flame ionisation detection or quadrupole mass spectrometry provided good reliability in the qualitative analysis of target analytes. However, GC×GC with time-of-flight mass spectrometry was needed in the analysis of unknowns. The automated identification procedure that was developed was efficient in the analysis of large data files, but manual search and analyst knowledge are invaluable as well. Quantitative analysis was examined in terms of calibration procedures and the effect of matrix compounds on GC×GC separation. In addition to calibration in GC×GC with summed peak areas or peak volumes, simplified area calibration based on normal GC signal can be used to quantify compounds in samples analysed by GC×GC so long as certain qualitative and quantitative prerequisites are met. In a study of the effect of matrix compounds on GC×GC separation, it was shown that quality of the separation of PAHs is not significantly disturbed by the amount of matrix and quantitativeness suffers only slightly in the presence of matrix and when the amount of target compounds is low. The benefits of GC×GC in the analysis of complex samples easily overcome some minor drawbacks of the technique. The developed instrumentation and methodologies performed well for environmental samples, but they could also be applied for other complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodimerization of acenaphthylene and 5,6-dichloroacenaphthylene solubilized in sodium dodecylsulphate (SDS), cetyltrimethylammonium chloride (CTAC), dodecyltrimethylammonium chloride (DTAC), cetyltrimethylammonium bromide (CTAB) and Triton X-100 micelles gives a mixture of cis and trans dimers. The magnitude of the cis:trans ratio is sensitive to the type of micelle used. In CTAB micelles the heavy atom effect of the bromide counter-ions leads to an increased triplet-derived trans dimer yield, whereas in micelles with light atom counter-ions (CTAC, DTAC and SDS) the singlet-derived cis dimer predominates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In view of the vast potential of micellar systems as media in which reactions may be conducted, a clear understanding of the structure of micelles is essential. The unique features of micelles and how these have been utilized to catalyse and control photochemical reactivity are briefly surveyed here. Micellar media, when used for chemical reactions, exhibit features that are completely different from those of ordinary non-aqueous solvents. A thermal or photochemical reaction conducted in micellar media is influenced by the effects of the micellar environment which result in control and/or modification of reactivity. The salient features of micelles that influence the photochemical reactivity are cage and microviscosity effects, localization and compartmentalization effects, pre-orientational, polarity and counterion effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodimerization of 2-substituted naphthalenes in organic solvents has been well explored. In contrast to their behavior in organic solvents, in anionic and cationic micellar media enhanced reactivity and pronounced regioselectivity are observed. Reactivity enhancement in micellar media is attributed to the local concentration effect. Enhanced reactivity in CTAC and DTAC compared to CTAB micelles is attributed to the counterion effect, and the regioselective photodimerization observed in anionic and cationic micelles leading exclusively to the cis dimer or the products derived therefrom is rationalized on the basis of the preorientational effect of micelles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the effect of rhamnolipid biosurfactant on the electrokinetic and rheological behavior of nanozirconia particles is reported. The effect of pH, concentration of biosurfactant, and solids loading on ζ-potential and rheological behavior was investigated. ζ-potential measurements showed that adsorption of biosurfactant shifted the iso-electric point of zirconia with increasing biosurfactant concentration. The surface of zirconia became more electronegative in the presence of biosurfactant indicating a strong interaction. Maximum charge was obtained in the presence of about 230 ppm of biosurfactant. Rheological tests at pH 7 revealed that the zirconia suspension is viscous at high solids loading and addition of biosurfactant decreased the viscosity substantially especially at high solids loading (>50 wt%). Sedimentation tests confirmed that the biosurfactant is a good dispersant for zirconia particles at pH values of 7 and above.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and rapid method for the separation of vitamins A1 and A2 and allied compounds by thin-layer chromatography using kieselgel has been described. The method, however, cannot bbe applied for quantitative estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An attempt has been made to review the literature that has accumulated during the last twelve years on the subject of paper chromatography of higher fatty acids. The various modifications that have been applied to the technique have been considered and their merits and limitations discussed. The important modifications are mainly concerned with the stationary and mobile phases and the use of different reagents for identification and estimation. This technique has also been successfully applied to the quantitative determination of the components of "critical pairs" of fatty acids in biological materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study of various reversed phase systems for the qualitative analysis of fatty acids has been made and it has been shown, among other things, that the liquid paraffin-aqueous methanol system is a most convenient one. The details of a fairly simple and rapid method for the quantitative estimation of higher fatty acids have also been discussed.