1000 resultados para METALLICITY DISTRIBUTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perhaps the most innovative of all independent OLD ventures specialising in ROW content is Jaman. Founded in 2007 by IT entrepreneur Gaurav Dhillon, and based in San Mateo, California, Jaman is a quality specialist distributor of non-Hollywood films. As of late 2010, Jaman had 1.8 million registered users and attracts viewers from most countries in the world. 75% of all use is generated from outside the U.S. Jaman does very well in English speaking parts of the world, particularly current and former Commonwealth countries. The United Kingdom accounts for 29% of users, North America (U.S. and Canada) 26%, and India represents 23%. Jaman is sometimes referred to as ‘social cinema’: a website which brings together the critique and review of a cinephile website (the forums of Rue-morgue.com for cinefantastique movie fans for example) with the social interaction, community and functionality of a social media site (for example Facebook.com). Jaman could be considered a pioneer in this space; a first mover in wrapping commercial movie downloading in an interactive social experience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The CDKN2 gene, encoding the cyclin-dependent kinase inhibitor p16, is a tumour suppressor gene that maps to chromosome band 9p21-p22. The most common mechanism of inactivation of this gene in human cancers is through homozygous deletion; however, in a smaller proportion of tumours and tumour cell lines intragenic mutations occur. In this study we have compiled a database of over 120 published point mutations in the CDKN2 gene from a wide variety of tumour types. A further 50 deletions, insertions, and splice mutations in CDKN2 have also been compiled. Furthermore, we have standardised the numbering of all mutations according to the full-length 156 amino acid form of p16. From this study we are able to define several hot spots, some of which occur at conserved residues within the ankyrin domains of p16. While many of the hotspots are shared by a number of cancers, the relative importance of each position varies, possibly reflecting the role of different carcinogens in the development of certain tumours. As reported previously, the mutational spectrum of CDKN2 in melanomas differs from that of internal malignancies and supports the involvement of UV in melanoma tumorigenesis. Notably, 52% of all substitutions in melanoma-derived samples occurred at just six nucleotide positions. Nonsense mutations comprise a comparatively high proportion of mutations present in the CDKN2 gene, and possible explanations for this are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper employs the industry of origin approach to compare value added and productivity of Singapore and Hong Kong's Distribution Trade Sector for the period 2001-2008. The direct comparison between these two economies was motivated by the statements of the Singapore government: Its services sector, especially in Retail Trade, lags behind Hong Kong's productivity levels. The results show that since 2005, Singapore's Distribution performance in terms of labour productivity was below Hong Kong's level, which was largely due to poor performance in its Retail Trade sector arising from an influx of foreign workers. Results from total factor productivity (TFP) between these two economies also suggest that Hong Kong's better performance (since 2005) was largely due to its ability to employ more educated and trained workers with limited use of capital. The results suggest that polices that worked in Hong Kong may not work for Singapore because its population is more diverse which poses a challenge to policy-makers in raising its productivity level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of the placement and rating of transformers and feeders are the main objective of the basic distribution network planning. The bus voltage and the feeder current are two constraints which should be maintained within their standard range. The distribution network planning is hardened when the planning area is located far from the sources of power generation and the infrastructure. This is mainly as a consequence of the voltage drop, line loss and system reliability. Long distance to supply loads causes a significant amount of voltage drop across the distribution lines. Capacitors and Voltage Regulators (VRs) can be installed to decrease the voltage drop. This long distance also increases the probability of occurrence of a failure. This high probability leads the network reliability to be low. Cross-Connections (CC) and Distributed Generators (DGs) are devices which can be employed for improving system reliability. Another main factor which should be considered in planning of distribution networks (in both rural and urban areas) is load growth. For supporting this factor, transformers and feeders are conventionally upgraded which applies a large cost. Installation of DGs and capacitors in a distribution network can alleviate this issue while the other benefits are gained. In this research, a comprehensive planning is presented for the distribution networks. Since the distribution network is composed of low and medium voltage networks, both are included in this procedure. However, the main focus of this research is on the medium voltage network planning. The main objective is to minimize the investment cost, the line loss, and the reliability indices for a study timeframe and to support load growth. The investment cost is related to the distribution network elements such as the transformers, feeders, capacitors, VRs, CCs, and DGs. The voltage drop and the feeder current as the constraints are maintained within their standard range. In addition to minimizing the reliability and line loss costs, the planned network should support a continual growth of loads, which is an essential concern in planning distribution networks. In this thesis, a novel segmentation-based strategy is proposed for including this factor. Using this strategy, the computation time is significantly reduced compared with the exhaustive search method as the accuracy is still acceptable. In addition to being applicable for considering the load growth, this strategy is appropriate for inclusion of practical load characteristic (dynamic), as demonstrated in this thesis. The allocation and sizing problem has a discrete nature with several local minima. This highlights the importance of selecting a proper optimization method. Modified discrete particle swarm optimization as a heuristic method is introduced in this research to solve this complex planning problem. Discrete nonlinear programming and genetic algorithm as an analytical and a heuristic method respectively are also applied to this problem to evaluate the proposed optimization method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a new graph-theory and improved genetic algorithm based practical method is employed to solve the optimal sectionalizer switch placement problem. The proposed method determines the best locations of sectionalizer switching devices in distribution networks considering the effects of presence of distributed generation (DG) in fitness functions and other optimization constraints, providing the maximum number of costumers to be supplied by distributed generation sources in islanded distribution systems after possible faults. The proposed method is simulated and tested on several distribution test systems in both cases of with DG and non DG situations. The results of the simulations validate the proposed method for switch placement of the distribution network in the presence of distributed generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protection of a distribution network in the presence of distributed generators (DGs) using overcurrent relays is a challenging task due to the changes in fault current levels and reverse power flow. Specifically, in the presence of current limited converter interfaced DGs, overcurrent relays may fail to isolate the faulted section either in grid connected or islanded mode of operation. In this paper, a new inverse type relay is presented to protect a distribution network, which may have several DG connections. The new relay characteristic is designed based on the measured admittance of the protected line. The relay is capable of detecting faults under changing fault current levels. The relay performance is evaluated using PSCAD simulation and laboratory experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of distributed reactive power control to improve the voltage profile of radial distribution feeders has been reported in literature by few authors. However, the multiple inverters injecting or absorbing reactive power across a distribution feeder may introduce control interactions and/or voltage instability. Such controller interactions can be alleviated if the inverters are allowed to operate on voltage droop. First, the paper demonstrates that a linear shallow droop line can maintain the steady state voltage profile close to reference, up to a certain level of loading. Then, impacts of the shallow droop line control on line losses and line power factors are examined. Finally, a piecewise linear droop line which can achieve reduced line losses and close to unity power factor at the feeder source is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distribution feeder voltage reinforcement by multiple site reactive power compensation systems has recently been reported by many researchers. However, voltage control by multiple DSTATCOMs across a distribution feeder may introduce control interactions and/or voltage instability. This paper addresses these control interaction issues and proposes a control scheme that alleviates interactions among controllers. The proposed control scheme also enhances proper sharing of reactive power among DSTATCOMs. A mathematical model of a distribution system with any number of DSTATCOMs is developed to investigate the performance of the control system. This mathematical model is used to conduct eigenvalue analysis to develop the criterion for controller design. The proposed control scheme is tested in time domain on a sample radial distribution feeder installed with multiple DSTATCOMs and test results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

‘Nobody knows anything’, said William Goldman of studio filmmaking. The rule is ever more apt as we survey the radical changes that digital distribution, along with the digitisation of production and exhibition, is wreaking on global film circulation. Digital Disruption: Cinema Moves On-line helps to make sense of what has happened in the short but turbulent history of on-line distribution. It provides a realistic assessment of the genuine and not-so-promising methods that have been tried to address the disruptions that moving from ‘analogue dollars’ to ‘digital cents’ has provoked in the film industry. Paying close attention to how the Majors have dealt with the challenges – often unsuccessfully – it focuses as much attention on innovations and practices outside the mainstream. Throughout, it is alive to, and showcases, important entrepreneurial innovations such as Mubi, Jaman, Withoutabox and IMDb. Written by leading academic commentators that have followed the fortunes of world cinema closely and passionately, as well as experienced hands close to the fluctuating fortunes of the industry, Digital Disruption: Cinema Moves On-line is an indispensable guide to great changes in film and its audiences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed generators (DGs) are defined as generators that are connected to a distribution network. The direction of the power flow and short-circuit current in a network could be changed compared with one without DGs. The conventional protective relay scheme does not meet the requirement in this emerging situation. As the number and capacity of DGs in the distribution network increase, the problem of coordinating protective relays becomes more challenging. Given this background, the protective relay coordination problem in distribution systems is investigated, with directional overcurrent relays taken as an example, and formulated as a mixed integer nonlinear programming problem. A mathematical model describing this problem is first developed, and the well-developed differential evolution algorithm is then used to solve it. Finally, a sample system is used to demonstrate the feasiblity and efficiency of the developed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endemic Burkitt lymphoma (BL) is etiologically associated with Epstein-Barr virus (EBV) and ecologically linked to Plasmodium falciparum malaria. However, these infections imperfectly correlate with BL epidemiology. To obtain recent epidemiological data, we studied district- and county-specific BL incidence and standardized incidence ratios using data collected from 1997 through 2006 at Lacor Hospital in northern Uganda, where studies were last done more than 30 years ago. Among 500 patients, median age was 6 years (inter-quartile range 5-8) and male-to-female ratio was 1.8:1. Among those known, most presented with abdominal (56%, M: F 1.4:1) vs. only facial tumors (35%, M: F 3.0:1). Abdominal tumors occurred in older (mean age: 7.0 vs. 6.0 years; p<0.001) and more frequently in female children (68% vs. 50%; OR 2.2, 95% CI 1.5-3.5). The age-standardized incidence was 2.4 per 100,000, being 0.6 in 1-4 year olds, 4.1 in 5-9 year olds and 2.8 in 10-14 year olds and varied 3-4-fold across districts. The incidence was lower in districts that were far from Lacor and higher in districts that were close to Lacor. While districts close to Lacor were also more urbanized, the incidence was higher in the nearby perirural areas. We highlight high BL incidence and geographic variation in neighboring districts in northern Uganda. While distance from Lacor clearly influenced the patterns, the incidence was lower in municipal than in surrounding rural areas. Jaw tumors were characterized by young age and male gender, but presentation has shifted away from facial to mostly abdominal. Keywords: Africa, cancer, malaria, Epstein-Barr virus, clustering, epidemiology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voltage drop and rise at network peak and off–peak periods along with voltage unbalance are the major power quality problems in low voltage distribution networks. Usually, the utilities try to use adjusting the transformer tap changers as a solution for the voltage drop. They also try to distribute the loads equally as a solution for network voltage unbalance problem. On the other hand, the ever increasing energy demand, along with the necessity of cost reduction and higher reliability requirements, are driving the modern power systems towards Distributed Generation (DG) units. This can be in the form of small rooftop photovoltaic cells (PV), Plug–in Electric Vehicles (PEVs) or Micro Grids (MGs). Rooftop PVs, typically with power levels ranging from 1–5 kW installed by the householders are gaining popularity due to their financial benefits for the householders. Also PEVs will be soon emerged in residential distribution networks which behave as a huge residential load when they are being charged while in their later generation, they are also expected to support the network as small DG units which transfer the energy stored in their battery into grid. Furthermore, the MG which is a cluster of loads and several DG units such as diesel generators, PVs, fuel cells and batteries are recently introduced to distribution networks. The voltage unbalance in the network can be increased due to the uncertainties in the random connection point of the PVs and PEVs to the network, their nominal capacity and time of operation. Therefore, it is of high interest to investigate the voltage unbalance in these networks as the result of MGs, PVs and PEVs integration to low voltage networks. In addition, the network might experience non–standard voltage drop due to high penetration of PEVs, being charged at night periods, or non–standard voltage rise due to high penetration of PVs and PEVs generating electricity back into the grid in the network off–peak periods. In this thesis, a voltage unbalance sensitivity analysis and stochastic evaluation is carried out for PVs installed by the householders versus their installation point, their nominal capacity and penetration level as different uncertainties. A similar analysis is carried out for PEVs penetration in the network working in two different modes: Grid to vehicle and Vehicle to grid. Furthermore, the conventional methods are discussed for improving the voltage unbalance within these networks. This is later continued by proposing new and efficient improvement methods for voltage profile improvement at network peak and off–peak periods and voltage unbalance reduction. In addition, voltage unbalance reduction is investigated for MGs and new improvement methods are proposed and applied for the MG test bed, planned to be established at Queensland University of Technology (QUT). MATLAB and PSCAD/EMTDC simulation softwares are used for verification of the analyses and the proposals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilizing a mono-specific antiserum produced in rabbits to hog kidney aromatic L-amino acid decarboxylase (AADC), the enzyme was localized in rat kidney by immunoperoxidase staining. AADC was located predominantly in the proximal convoluted tubules; there was also weak staining in the distal convoluted tubules and collecting ducts. An increase in dietary potassium or sodium intake produced no change in density or distribution of AADC staining in kidney. An assay of AADC enzyme activity showed no difference in cortex or medulla with chronic potassium loading. A change in distribution or activity of renal AADC does not explain the postulated dopaminergic modulation of renal function that occurs with potassium or sodium loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of multiple distribution static synchronous compensators (DSTATCOMs) to improve the voltage profile of radial distribution networks has been reported in the literature by few authors. However, the operation of multiple DSTATCOMs across a distribution feeder may introduce control interactions and/or voltage instability. This study proposes a control scheme that alleviates interactions among controllers and enhances proper reactive power sharing among DSTATCOMs. A generalised mathematical model is presented to analyse the interactions among any number of DSTATCOMs in the network. The criterion for controller design is developed by conducting eigenvalue analysis on this mathematical model. The proposed control scheme is tested in time domain on a sample radial distribution feeder installed with multiple DSTATCOMs and test results are presented.