937 resultados para Low-flow gas
Resumo:
Participation as observer at the meeting of Task 14 of IEA's Solar Heating and Cooling Projects held in Hameln, Germany has led to greater understanding of interesting developments underway in several countries. This will be of use during the development of small scale systems suitable for Swedish conditions. A summary of the work carried out by the working groups within Task 14 is given, with emphasis on the Domestic Hot Water group. Experiences of low-flow systems from several countries are related, and the conclusion is drawn that the maximum theoretical possible increase in performance of 20% has not been achieved due to poor heat exchangers and poor stratification in the storage tanks. Positive developments in connecting tubes and pumps is noted. Further participation as observer in Task 14 meetings is desired, and is looked on favourably by the members of the group. Another conclusion is that SERC should carry on with work on Swedish storage tanks, with emphasis on better stratification and heat exchangers, and possible modelling of system components. Finally a German Do-it-Vourself kit is described and judged in comparison with prefabricated models and Swedish Do-it-Yourself kits.
Resumo:
The importance of investigating cost reduction in materials and components for solar thermal systems is crucial at the present time. This work focuses on the influence of two different heat exchangers on the performance of a solar thermal system. Both heat exchangers studied are immersed helically coiled, one made with corrugated stainless steel tube, and the other made with finned copper tube with smooth inner surface.A test apparatus has been designed and a simple test procedure applied in order to study heat transfer characteristics and pressure drop of both coils. Thereafter, the resulting experimental data was used to perform a parameter identification of the heat exchangers, in order to obtain a TRNSYS model with its corresponding numerical expression. Also a representative small-scale combisystem model was designed in TRNSYS, in order to study the influence of both heat exchangers on the solar fraction of the system, when working at different flow rates.It has been found that the highest solar fraction is given by the corrugated stainless steel coil, when it works at the lowest flow rate (100 l/hr). For any higher flow rate, the studied copper coil presents a higher solar fraction. The advantageous low flow performance of stainless steel heat exchanger turns out to be beneficial for the particular case of solar thermal systems, where it is well known that low flow collector loops lead to enhanced store stratification, and consequently higher solar fractions.Finally, an optimization of the stainless steel heat exchanger length is carried out, according to economic figures. For the given combisystem model and boundary conditions, the optimum length value is found between 10 and 12 m.
Resumo:
This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV
Resumo:
Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.
Resumo:
Background: An upper limb arteriovenous (AV) fistula is the access of choice for haemodialysis (HD). There have been few reports of saphenofemoral AV fistulas (SFAVF) over the last 10-20 years because of previous suggestions of poor patencies and needling difficulties. Here, we describe our clinical experience with SFAVF.Methods: SFAVFs were evaluated using the following variables: immediate results, early and late complications, intraoperative and postoperative complications (up to day 30), efficiency of the fistula after the onset of needling and complications associated to its use.Results: Fifty-six SFAVF fistulas were created in 48 patients. Eight patients had two fistulas: 8 patent (16%), 10 transplanted (20%), 12 deaths (24%), 1 low flow (2%) and 20 thrombosis (39%) (first two months of preparation). One patient had severe hypotension during surgery, which caused thrombosis of the fistula, which was successfully thrombectomised, four thrombosed fistulae were successfully thrombectomised and revised on the first postoperative day. After 59 months of follow-up, primary patency was 44%.Conclusion: SFAVF is an adequate alternative for patients without the possibility for other access in the upper limbs, allowing efficient dialysis with good long-term patency with a low complication rate.
Resumo:
Este trabalho tem como objetivos verificar as áreas de cria e alimento e a longevidade de operárias em colmeias de Apis mellifera, em apicultura fixa (mata) e migratória (laranja e eucalipto), sem (T1) e com (T2) tela excluidora de rainha. Foram utilizadas colmeias modelo Langstroth, com sobrecaixa. Na apicultura fixa, estas colmeias foram analisadas durante 476 dias e mapeadas a cada 30 a 45 dias para obtenção das áreas de cria e alimento. Na migratória, as colmeias foram analisadas antes e após a florada. Foi estudada também a longevidade das operárias, nos dois tratamentos. Os dados mostraram que em fluxo baixo de néctar (apicultura fixa, em mata), o uso de tela excluidora apresentou maior eficiência na separação do mel das crias. Entretanto, quando o fluxo de néctar foi alto (floradas de laranja e eucalipto), a tela excluidora não foi eficiente, pois as abelhas rapidamente preencheram os favos disponíveis no ninho inferior, misturando-o com cria. Observou-se também redução na longevidade das operárias das colmeias com tela excluidora, em dois dos três testes realizados. Este trabalho, desenvolvido em três locais diferentes, com plantas apícolas distintas evidenciou também a variabilidade e a grande influência ambiental no desenvolvimento das colônias de Apis mellifera.
Resumo:
Tungsten carbide, WC, has shown dissimilar thermal behavior when it is heated on changeable heating rate and flow of oxidant atmosphere. The oxidation of WC to WO3 tends to be in a single and slow kinetic step on slow heating rate and/or low flux of air. Kinetic parameters, on non-isothermal condition, could be evaluated to the oxidation of WC to heating rate below 15 degrees C min(-1) or low flow of air (10 mL min(-1)). The reaction is governed by nucleation and growth at 5 to 10 degrees C min(-1) then the tendency is to be autocatalytic, JMA and SB, respectively.
Resumo:
Sugar cane burning in Brazil causes remarkable amounts of organic compounds to be emitted amongst which the polycyclic aromatic hydrocarbons (PAHs) represent serious health hazards. Therefore, 24-h aerosol samples (< 10 mum aerodynamic diameter) were collected in Araraquara city (São Paulo state) during the harvest season using a Hi-Vol sampler. PAHs were recovered using an Accelerated Solvent Extractor and analyzed by low-pressure gas chromatography-ion trap mass spectrometry (LP-GC-IT-MS). The fully automated extraction process was performed in less than 25 min with a solvent consumption of approximately 20 ml. The use of a deactivated 0.6 m x 0. 10 mm i.d. restrictor coupled to a 10 m wide-bore analytical column allowed most of the 16 PAHs in EPA's priority list to be identified and quantified in only 13 min. Concentrations of PAHs in Nraraquara aerosols ranged between 0.5 and 8.6 ng m(-3). (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Background and Objectives - Sevoflurane is an inhalational anesthetic drug with low blood/gas solubility providing fast anesthesia induction and emergence. Its ability to maintain cardiovascular stability makes it ideal for pediatric anesthesia. The aim of this study was to evaluate hemodynamic stability, consumption of inhalational anesthetics and emergence time in children with and without premedication (midazolam or clonidine) anesthetized with sevoflurane titrated according to BIS monitoring. Methods - Participated in this study 30 patients aged 2 to 12 years, physical status ASA I, undergoing elective surgeries who were divided into 3 groups: G1 - without premedication, G2 - 0.5 mg.kg-1 oral midazolam, G3 - 4 μg.kg-1 oral clonidine 60 minutes before surgery. All patients received 30 μg.kg-1 alfentanil, 3 mg.kg-1 propofol, 0.5 mg.kg-1 atracurium, sevoflurane in different concentrations monitored by BIS (values close to 60) and N2O in a non rebreathing system. Systolic and diastolic blood pressure, heart rate, expired sevoflurane concentration (EC), sevoflurane consumption (ml.min-1) and emergence time were evaluated. Emergence time was defined as time elapsed between the end of anesthesia and patients' spontaneous movements trying to extubate themselves, crying and opening eyes and mouth. Results - There were no differences among groups as to systolic and diastolic blood pressure, EC, sevoflurane consumption and emergence time. Heart rate was lower in G3 group. Conclusions - Sevoflurane has provided hemodynamic stability. Premedication with clonidine and midazolam did not influence emergence time, inhaled anesthetic consumption or maintenance of anesthesia with sevoflurane. Anesthesia duration has also not influenced emergence time. Hypnosis monitoring was important for balancing anesthetic levels and this might have been responsible for the similarity of emergence times for all studied groups.
Resumo:
Objectives: To investigate the effect of fluoride (0, 275 and 1250 ppm F; NaF) in combination with normal and low salivary flow rates on enamel surface loss and fluoride uptake using an erosion-remineralization-abrasion cycling model. Design: Enamel specimens were randomly assigned to 6 experimental groups (n = 8). Specimens were individually placed in custom made devices, creating a sealed chamber on the enamel surface, connected to a peristaltic pump. Citric acid was injected into the chamber for 2 min followed by artificial saliva at 0.5 (normal flow) or 0.05 (low flow) ml/min, for 60 min. This cycle was repeated 4×/day, for 5 days. Toothbrushing with abrasive suspensions containing fluoride was performed for 2 min (15 s of actual brushing) 2×/day. Surface loss was measured by optical profilometry. KOH-soluble fluoride and enamel fluoride uptake were determined after the cycling phase. Data were analysed by two-way ANOVA. Results: No significant interactions between fluoride concentration and salivary flow were observed for any tested variable. Low caused more surface loss than normal flow rate (p < 0.01). At both flow rates, surface loss for 0 was higher than for 275, which did not differ from 1250 ppm F. KOH-soluble and structurally-bound enamel fluoride uptake were significantly different between fluoride concentrations with 1250 > 275 > 0 ppm F (p < 0.01). Conclusions: Sodium fluoride reduced enamel erosion/abrasion, although no additional protection was provided by the higher concentration. Higher erosion progression was observed in low salivary flow rates. Fluoride was not able to compensate for the differences in surface loss between flow rates. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)