970 resultados para Low voltage varistor


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Glioblastoma multiforme (GBM) is the most common malignant primary brain tumor in adults. Standard therapeutic approaches provide modest improvement in the progression-free and overall survival, necessitating the investigation of novel therapies. We review the standard treatment options for GBM and evaluate the results obtained in clinical trials for promising novel approaches, including the inhibition of angiogenesis, targeted approaches against molecular pathways, immunotherapies, and local treatment with low voltage electric fields.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Taajuusmuuttajat aiheuttavat toimintansa seurauksena runsaasti laajakaistaisia sähkömagneettisia häiriöitä. Häiriöt etenevät sekä johtumalla että säteilemällä ja ne ovat seurausta pääasiassa taajuusmuuttajien toimintaan perustuvista nopeista kytkentäilmiöistä sekä puolijohdekomponenttien epälineaarisuuksista. Sähkömagneettisille häiriöille määritellään suurimmat sallitut tasot useissa EMC-standardeissa. Taajuusmuuttajia koskevia EMC-standardia on neljä; tuotestandardi EN 61800-3, harmonisia virtoja pienjänniteverkoissa käsittelevä EN 61000-3-12 sekä yleiset standardit EN 61000-6-1, -6-2 ja EN 61000-6-3, -6-4. Tämän diplomityön tarkoituksena on tutkia ja koota yhteen edellä mainittujen standardien sisältämät vaatimukset. Työn pääpaino on kohdistettu häiriöpäästöille asetettuihin vaatimuksiin, sillä häiriöiden sietoon liittyvien vaatimusten täyttäminen ei taajuusmuuttajien kohdalla yleensä tuota ongelmia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sähkökäytön valintaan vaikuttavat useat eri tekijät. Sähkökäytön valinnan perusteena voidaan käyttää tietoa prosessin tai toimilaitteen fysikaalisesta käyttäytymisestä. Valinnan perusteena voi olla myös riittävän suorituskyvyn tarve prosessissa. Tässä työssä tutustutaan sähkökäytön valintaan vaikuttaviin tekijöihinja sähkökäytön mitoitukseen. Työssä on keskitytty yleisempien pienjännitemoottorityyppien ja niiden säätöjen käsittelyyn. Useissa prosesseissa vaaditaan monen moottorin käyttöä saman kuorman liikuttamisessa. Monimoottorikäyttöjen ohjauksen tuntemus auttaa ongelmatilanteiden ratkaisussa ja antaa perusteet monimoottorikäytön valinnalle. Tässä työssä käsitellään monimoottorikäyttöjen pyörimisnopeuserojen ja vääntömomenttien epätasaisuuteen liittyviä ongelmia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diplomityössä määritellään sähkönjakeluverkon suunnitteluperusteet. Suunnitteluperusteet antavat ohjeet verkostosuunnittelijoille siitä, miten sähköverkko suunnitellaan sähköteknisesti oikein, taloudelliset näkökohdat huomioiden. Työn alussa määritellään kaikkiin suunnittelutehtäviin vaikuttavat sähkötekniset ja taloudelliset laskentaparametrit. Oikeiden parametrien käyttäminen on ehdottoman tärkeää totuudenmukaisten lopputulosten saavuttamiseksi. Eniten lopputuloksiin vaikuttaville laskentaparametreille suoritetaan työn loppuosassa herkkyysanalyysi, jotta tulevaisuuden mahdollisesti erilaiset olosuhteet voitaisiin huomioida. Varsinaisissa suunnitteluun liittyvissä osioissa käsitellään keski- ja pienjänniteverkkojen suunnittelunlisäksi jakelumuuntajan mitoittaminen, sekä määritellään rajat erilaisille verkoston rakenteille. Erityisesti elinkaarikustannusajattelua painotetaan suunnittelutehtävissä ottamalla huomioon komponenttien koko pitoaikana syntyvät kustannukset.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Perinteiset sähkökoneen eristemateriaalit eivät kestä vesihöyryä. Vesihöyryä kestävä eristerakenne on tarpeen, kun tehdään hermeettinen turbogeneraattori, jossa vesihöyry virtaa ilmavälin läpi. Tällainen turbogeneraattori mahdollistaa teholtaan tavallista pienemmän biopolttoainevoimalan rakentamisen kustannustehokkaasti. Työssä tutkittiin erilaisia pyörölankakäämityn pienjännitekoneen eristemateriaaleja. Pienoismallikokein testattiin ne eristemateriaalit, joiden uskottiin kirjallisuustietojen perusteella selviytyvän vesihöyryssä. Myös perinteinen, polyesteriin pohjautuva eristerakenne testattiin. Kokeiden perusteella valittiin turbogeneraattorin staattoriin sopiva eristerakenne.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Suuritehoisissa pumppu- ja puhallinkäytöissä käytetään usein suurnopeusmoottoria,jota syötetään välijännitteellä. Suurjännitetaajuudenmuuttajat ovat kalliita, eikä niitä ole aina edes mahdollista valmistaa. Tutkimuksen kohteena on rinnakkaisilla pienjännitetaajuudenmuuttajilla toteutettu sähkökäyttö, jossa pienjännite nostetaan moniensiöisellä muuntajalla suurjännitteeksi (6,6 kV) ja syötetään edelleen kuormana olevalle suurnopeusmoottorille. Opinnäytetyössä tutkitaan moniensiöisen muuntajan syöttöä rinnakkaisilla taajuudenmuuttajilla sekä niiden aiheuttamia häiriöitä toisilleen. Työssä tutkitaan myös harmonisten yliaaltojen vaikutuksia muuntajan häviöihin ja magnetointiominaisuuksiin. Taajuudenmuuttajan lähtöjännite ja -virta suodatetaan sinisuotimella, jonka parametreja simuloidaan Simulink- ohjelmistolla. Tavoite on löytää optimaaliset parametrit taajuudenmuuttajanlähtösuotimelle käyrämuotojen ja suotimeen jäävän tehon suhteen. Työssä tarkasteltiin sinisuodinta, johon jää 3 prosenttia syöttöjännitteestä. LC-suodin kompensoi sähkökäytön loistehon lähes kokonaan, joten taajuudenmuuttajien antotehon kannalta suotimet ovat perusteltuja. Taajuudenmuuttajan näennäisteho putoaa 22 prosenttia, joten taajuudenmuuttajat voidaan vastaavasti mitoittaa pienemmiksi.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä simuloitiin Valkealassa sijaitsevaa Tirvan pienvesivoimalaitosta ja sen vaikutusta sähkönjakeluverkkoon. Pienvesivoimalaitos mallinnettiin PSCAD-ympäristöön verkko- ja voimalaitostietojen perusteella. Sähköverkko kuvattiin malliin koko 110 kV:n siirtävän verkon ja Tirvan pienjänniteverkon väliltä. Mallin avulla tehtiin sarja hajautettua sähköntuotantoa koskevia tarkasteluita. Tarkasteluissa huomattiin voimalaitoksen verkkoonliitynnän aiheuttavan standardien ylärajoilla olevan transienttisen muutoksen voimalaitoksen jännitteisiin. Työssä tehtiin yksityiskohtaisempi jännitehäviöiden mittaus voimalaitoksen pullonkaulana toimivalle pienitehoiselle jakelumuuntajalle. Tuotannon lisäämisen yhteydessä näkyvän yllättävän jännitteen laskun syyt paikannettiin muuntajalla tapahtuviin loistehon siirrosta johtuviin ylimääräisiin jännitehäviöihin. Voimalaitoksella ei ole merkittävää vaikutusta vikatilanteiden virtoihin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of the three voltage level 20/1/0.4 distribution system in Finland has proved to be an economic solution to enhance the reability of electricity distribution. By using 1 kV voltage level between medium and low voltage networks, the improvement in reability could be reached especially inaerial lines networks. Also considerable savings in investment and outage costscould be archieved compared to the traditional distribution system. This master's thesis is focused on the describing the situation in Russian distribution netwoks and consequent analyses the possibility of applying 1000V distribution system in Russia. The goal is to investigate on the basis of Finnish experience is any possible installation targets in Russia for the new system. Compatibility with Russian safety and quality standards are also studied in this thesis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Interconnection of loads and small size generation forms a new type of distribution systems, the Microgrid. The microgrids can be operated together with the utility grid or be operated autonomously in an island. Thesesmall grids present a new paradigm of the construction of the low voltage distribution systems. The microgrids in the distribution systems can become small, controllable units, which immediately react to the system's changes. Along with that the microgrids can realize the special properties, such as increasing the reliability, reducing losses, voltage sag correction, uninterruptible supplying. The goals of the thesis are to explain the principles of the microgrid's functioning, to clarify the main ideas and positive features of the microgrids, to find out and prove their advantages and explain why they are so popular nowadays all over the world. The practical aims of the thesis are to construct and build a test setup of a microgrid based on two inverters from SMA Technologie AG in the laboratory and to test all the main modes and parameters of the microgrid's operating. Also the purpose of the thesis is to test the main component of the microgrid - the battery inverter which controls allthe processes and energy flows inside a microgrid and communicates with the main grid. Based on received data the main contribution of the thesis consists of the estimation of the established microgrid from the reliability, economy and simplicity of operating points of view and evaluation ofthe advisability of its use in different conditions. Moreover, the thesis assumes to give the recommendations and advice for the future investigations of the built system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pienjännitejakeluverkko Suomessa on toteutettu 400 V:n kolmivaiheisella vaihtosähköllä. Pienestä jännitteestä johtuen 20/0.4 kV:n muuntajat täytyy sijoittaa lähelle kuluttajaa, jotta siirtohäviöt eivät nouse liian suuriksi. Suuremman vaihto- tai tasajännitteen käyttö pienjännitejakelussa kasvattaisi verkon tehonsiirtokapasiteettia ja mahdollistaisi pidempien siirtomatkojen käytön. Käynnissä olevassa tutkimushankkeessa käsitellään vaihtoehtoa, jossa tasajännitettä käytettäisiin 20 kV:n verkon ja kuluttajan välisessä tehonsiirrossa ja kuluttajalla sijaitseva vaihtosuuntaaja muodostaisi tasasähköstä standardien mukaista yksi- tai kolmivaiheista vaihtosähköä. Tässä diplomityössä käsitellään tehoelektroniikan soveltamista kuluttajalle sijoitetussa vaihtosuuntaajassa. Työssä tarkastellaan yksivaiheisia invertteritopologioita, niiden ohjausta ja soveltamista erilaisissa vaihtosuuntaajaratkaisuissa sekä LC- ja LCL-suotimien soveltuvuutta invertterin lähtöjännitteen suodatukseen. Lisäksi esitellään erilaisia rakenneratkaisuja vaihtosuuntauksen toteutukseen ja tarkastellaan näiden järjestelmien vikatilanteita ja sähköturvallisuutta. Lopuksi käsitellään koko järjestelmän häviöitä ja hyötysuhdetta eri suodinkomponenteilla sekä kytkentätaajuuksilla ja esitellään laboratorioprototyyppi. Työssä saatiin selville, että puolisiltainvertteri ei sovellu suurten kondensaattorien vuoksi syöttämään verkkotaajuista kuormaa, vaan joudutaan käyttämään kokosiltainvertteriä. Kokosiltainvertterin ja LC- tai LCL-suotimen käsittävää kokonaisuutta tarkasteltaessa havaittiin, että pienimmät häviöt saavutetaan LC-suotimella 5 %:n ja LCL-suotimella 1 %:n särövaatimuksella. Hyötysuhdekäyrää tarkasteltaessa saatiin sama tulos läpi koko invertterin tehoalueen. Suotimen häviöiden tarkka laskenta on kuitenkin erittäin haasteellista, joten tulokset ovat suuntaa-antavia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sähkönjakeluverkkojen kehittäminen nykyistä käyttövarmemmiksi ja taloudellisemmiksi vaatii jatkuvasti uusia ratkaisumalleja. Lupaavaksi tekniikaksi sähkönjakeluverkkojen kehittämisessä on osoittautumassa tasasähkönjakelu tehoelektronisten komponenttien kehittyessä ja hintojen laskiessa samanaikaisesti. Pienjännitedirektiivi mahdollistaa tasajännitteen myötä aiempaa suurempien jännitteiden käytön pienjänniteverkoissa. Tasajännitteen käytöllä voidaan saavuttaa etuja mm. tehonsiirtokyvyssä, sähkönlaadussa, käyttövarmuudessa sekä kustannuksissa. Työssä tehdään yksityiskohtaisia teknistaloudellisia tarkasteluja perinteistä 20/0,4 kV tekniikkaa, 1000 V sähkönjakelua sekä tasasähköjärjestelmiä hyödyntäen ja verrataan näiden järjestelmien kustannuksia ja ominaisuuksia toisiinsa. Tutkimusalueet on valittu Fortum Sähkönsiirto Oy:n maaseutu- ja taajamaverkoista. Työssä pyritään hahmotta-maan teknistaloudellista käyttöaluetta eri tasasähkönjakelujärjestelmille sekä määrittä-mään tasasähkönjakelun käyttöpotentiaali tutkimuskohteena olleissa verkoissa. Lisäksi tutkitaan eri tekijöiden vaikutuksia tasasähköjakelun kannattavuuteen ja käyttövarmuu-teen sekä pyritään tuomaan esiin muitakin tasasähkönjakelujärjestelmien ominaisuuksia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tämän diplomityön tarkoitus on selvittää pienjakelujännitteen nostosta aiheutuvia vaikutuksia sellutehtaan varavoimaverkossa. Työn alussa esitellään varavoimaverkkoon kuuluvia osia, selvitetään erilaisten kuormien vaikutusta varavoimaverkon sähkön laatuun sekä kuormien jakoa varmennettuihin verkkoihin. Seuraavaksi suunnitellaan kaksi keskitettyä varavoimaverkkomallia eri pienjakelujännitteillä. Mallien nimellisjännitteet ovat 400 V ja 690 V. Varavoimaverkkomallien kuormat ja osastojen väliset etäisyydet on otettu valmiista sellutehtaista. Tässä diplomityössä painotutaan erityisesti varavoimaverkkomallien mitoitukseen ja jakelujännitteen nostosta aiheutuvien vaikutusten teknistaloudelliseen vertailuun. Vertailu tehdään keskijännitekojeiston ja varavoimakeskusten välisellä alueella, johon kuu-luvat jakelumuuntaja, varavoimakone, varavoimapääkeskus, kiskosillat, jakelukaapelit, kytkinvaroke- ja katkaisijalähdöt sekä mahdolliset välimuuntajat. Varavoimaverkkojen välisessä kustannusvertailussa käytetään nykyarvomenetelmää.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä tutkitaan 1000 V pienjännitejakelun taloudellista kannattavuutta. Tutkimus perustuu teoreettiseen tarkasteluun, jossa noudatetaan yleisiä verkostosuunnittelun periaatteita. EU-lainsäädäntö mahdollistaa 1000 V pienjänniteportaan sijoittamisen nykyisen keskijänniteverkon ja pienjänniteverkon väliin lisäten kolmannen jakelujänniteportaan nykyään käytettävien 20 kV ja 0,4 kV väliin. Jakeluverkkojen kehittämiseksi on etsittävä ratkaisu, joka on taloudellinen sekä asiakkaiden että verkonhaltijoiden kannalta. Tällaiset ratkaisut pienentävät verkon käytön kokonaiskustannuksia ja parantavat sähkön laatua. Lisättäessä jakeluverkkoon kolmas jänniteporras, keskijänniteverkon johtopituus lyhenee ja varsinkin lyhyiden haarajohtojen määrä vähenee. Tämä vähentää keskijänniteverkossa esiintyvien keskeytysten määrää ja pienentää keskeytyskustannuksia. Kilovoltin järjestelmä on kannattava korvattaessa sillä osa keskijänniteverkkoa, tai estettäessä perinteisellä järjestelmällä tarvittava muuntopiirin jakaminen. Osana varsinaista pienjänniteverkkoa ei kilovoltinjärjestelmä ole kannattava. Tässä työssä kolmijänniteportaista jakeluverkkoa tutkitaan teoreettisilla verkkosuunnitelmilla, joita tehdään muutamille perusverkkotopologioille. Taloudellista kannattavuutta tutkitaan vertaamalla perinteistä kaksijänniteportaista ja kolmijänniteportaista verkkoratkaisua kustannusten suhteen teknisten reunaehtojen puitteissa. 1000 V pienjännitejakelu vaatii uudenlaisia verkostokomponentteja. Näistä on erityisesti käsitelty 1/0,4 kV pienjännitemuuntajaa. Muuntajasuunnittelun lähtökohtana on 1000 V verkon käyttäminen keskijänniteverkon jatkeena maasta erotettuna verkkona.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tässä työssä on tarkasteltu sähkönjakeluverkon primäärikomponenttien elinkaaria niiden energiankulutuksen näkökulmasta. Työssä kerrotaan elinkaarianalyysin käyttämisestä tutkimusmenetelmänä erityisesti sähkönjakeluverkkojen tarkastelussa. Tarkasteltaviksi komponenteiksi on valittu 110 kV/20 kV sähköasemalta päämuuntajat ja keskijännitepuolen kojeistot, keskijännitejohtolähdön maakaapeli ja ilmajohtorakenteet sekä jake-lumuuntajat, pienjännitemaakaapelit ja -avojohdot. Työssä esitetään yksinkertainen menetelmä komponenttien elinkaarien aikana kuluvan energiamäärän ja siitä aiheutuvien CO2-päästöjen arviointiin. Lisäksi esitetään tuloksia tehdyistä esimerkkitarkasteluista ja analyysin lähtötietojen määrittämisestä. Työn tarkoitus on auttaa verkkoyhtiöitä arvioimaan komponentti-investointien kannattavuutta energiatehokkuuden näkökulmasta. Energiahäviöt ovat usein verkkoyhtiön suurin asiakas ja päästökaupan myötä myös CO2-päästöillä on hintansa. Energiatehokkaiden ratkaisujen käyttäminen on tullut entistä tärkeämmäksi komponentteja uusittaessa.