971 resultados para LASER FLUORESCENCE METHOD


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this clinical study was to evaluate the effectiveness of the toothbrushing with and without fluoride and the daily fluoride rinse (NaF 0.05%) on produced white spot, in vivo. This was a clinical study, controlled, randomized and triple blind. Thirty patients were selected for orthodontics reasons from Orthodontics Specialization Course at the Brazilian Dental Association - Section of Rio Grande do Norte. In this study it was used 4 bicuspid upper and lower. They had orthodontic reason for extractions, in 35 days, at least. The sample had one hundred and twenty teeth that received orthodontic bands. The bands were fixed with polycarboxylate cement, and there was a space standardized between bands and one surface of teeth. The four bicuspid of each patients were randomized and nominated as A, B, C and D. These nominations determinated the sequence of the extractions and what was done in each tooth. All the patients had been submitted to the toothbrushing with or without fluoride for 35 days. After this period, the A tooth of each patient was extracted to serve as control. The others teeth (B, C and D) were extracted one by each week. The entire sample was analyzed through the clinical examination and by laser fluorescence (DIAGNOdent®) in three different times: before orthodontic bands, 28 days after fixed and then removed the bands and, the last one, 07 days after one of the three treatments (toothbrushing with or without fluoride, tooth paste with fluoride and mouth rinse with fluoride). At the beginning all groups (A, B, C and D) had the same conditions, no significant difference was found. The same situation was found in a clinical examination. The results of the DIAGNOdent® for the groups that used tooth paste without fluoride, with fluoride and mouth rinse with fluoride, after 28 days, there was no significant difference. Clinically, the white spot was formed in all teeth after 28 days. When it was compared the three treated groups, the group without fluoride in tooth paste had worst result than the others groups. But there was no significant association between the number of active and inactive white spots and the type of treatment that the teeth had received. The demineralization of the enamel surface, under the orthodontic bands, it happened in a few weeks. The exposition of the white spots in oral environmental resulted in an improvement, but it was not enough to return to the values from the base line, either for the toothbrushing and/or the use of fluorite mouth rinse. Mouth rinse and toothpaste with fluoride have showed to reduce the incidence of demineralization in the enamel, but none seems to be superior to another one in an in vivo study

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A escolha e o uso adequado de pontas de pulverização são essenciais para a correta aplicação de produtos fitossanitários, sendo, portanto, indispensável o conhecimento de suas características. Este trabalho teve o objetivo de caracterizar o perfil de distribuição e o diâmetro de gotas, oferecendo dados para otimizar o espaçamento entre bicos na barra de pulverização. Foram avaliados os perfis de distribuição da ponta de jato plano Teejet XR 110015 VS, a 0,50 m da altura da mesa de deposição, nas pressões de 200 e 300 kPa, e o diâmetro das gotas pelo método de difração de raios laser. As distâncias máximas foram de 0,85 m, calculadas para um coeficiente de variação (C.V.) aceitável para as pressões de 200 e 300 kPa , com os respectivos valores de 9,52 e 9,58%. A distância ótima foi de aproximadamente 0,70 m, para C.V. em torno de 5%. Comparando as pressões, houve diferença significativa para DV0,1 e DV0,5, não havendo diferença para o DV0,9. Embora o aumento da pressão tenha provocado diminuição do tamanho das gotas, não houve diferença significativa de uniformidade entre as duas pressões de trabalho avaliadas. Concluiu-se que o espaçamento máximo entre bicos na barra não deverá ser maior que 0,85 m e que o DV0,5 diminui com o aumento da pressão de 200 para 300 kPa, porém sem alteração significativa da uniformidade de diâmetro de gota.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dental caries consists in a multifactorial and dynamic process. The knowledge of the ionic interactions among dental tissues and dental biofilm make possible its understanding as a process that can be stopped. Recently, the use of sealants have lost its function as preventive agent and passed to be argued as a possible therapeutical agent. This happens by hindering the substratum flow to the lesion inner and, therefore, controls the advance of the process. This study aimed to evaluate glass ionomer cement as a not invasive technique of treatment in occlusal caries without clinical cavitation, but with dentinal involvement. The research was accomplished using a controlled clinical trial with two groups (experimental and control) in 38 subjects (8-18 years) with 51 molars. The teeth of the experimental group were sealed with glass ionomer cement (Vidrion-R, S.S.White, Juiz de Fora, Brazil) and the molars control did not suffer intervention. The experimental group was followed by a year and the control by 8 months due the progression of the carious injury. Both groups were reevaluated to each 4 months with the use of clinical, radiographic and laser fluorescence (DIAGNOdent®) examination. The analysis of the clinical evaluation did not observe a significant difference between experimental and control groups. However, analysis with radiographic and laser fluorescence (DIAGNOdent®) examination observed a significant difference (p> 0,05) between groups, demonstrating a wors condition to the group without intervention. The results suggest that glass ionomer cement as sealant can be efficient to paralyze dentinal caries without clinical cavitation

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to determine the extent of DNA fragmentation and the presence of denatured single-stranded or normal double-stranded DNA in spermatozoa with large nuclear vacuoles (LNV) selected by high magnification. Fresh semen samples from 30 patients were prepared by discontinuous isolate concentration gradient. Spermatozoa with normal nucleus (NN) and LNV were selected at x8400 magnification and placed on different slides. DNA fragmentation was determined by TUNEL assay. Denatured and double-stranded DNA was identified by the acridine orange fluorescence method. DNA fragmentation in spermatozoa with LNV (29.1%) was significantly higher (P < 0.001) than in spermatozoa with NN (15.9%). Therefore, cleavage of genomic DNA in low molecular weight DNA fragments (mono- and oligonucleosomes), and single-strand breaks (nicks) in high molecular weight DNA occur more frequently in spermatozoa with LNV. Similarly, the percentage of denatured-stranded DNA in spermatozoa with LNV (67.9%) was significantly higher (P < 0.0001) than in spermatozoa with NN (33.1%). The high level of denatured DNA in spermatozoa with LNV suggests precocious decondensation and disaggregation of sperm chromatin fibres. The results show an association between LNV and DNA damage in spermatozoa, and support the routine morphological selection and injection of motile spermatozoa at high magnification for ICSI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to determine the extent of DNA fragmentation and the presence of denatured single-strand or normal double-strand DNA in spermatozoa with extruded nuclear chromatin (ENC) selected by high magnification. Fresh semen samples from 55 patients were prepared by discontinuous isolate concentration gradient. Spermatozoa with normal nucleus (NN) and ENC were selected at 8400x magnification and placed on different slides. DNA fragmentation was determined by TUNEL assay. Denatured and double-stranded DNA was identified by the acridine orange fluorescence method. DNA fragmentation was not significantly different (p = 0.86) between spermatozoa with ENC (19.6%) and those with NN (20%). However, the percentage of spermatozoa with detectable denatured-stranded DNA in the ENC spermatozoon group (59.1%) was significantly higher (p < 0.0001) than in the NN group (44.9%). The high level of denatured DNA in spermatozoa with ENC suggests premature decondensation and disaggregation of sperm chromatin fibres. The results show an association between ENC and DNA damage in spermatozoa, and support the routine morphological selection and injection of motile spermatozoa at high-magnification intracytoplasmic sperm injection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to assess the influence of cleaning pits and fissures with on aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods. The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnification was used as the gold standard Results. Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and 0 specificity of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specificity of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to determine the extent of DNA fragmentation and the presence of single/denatured or double stranded of DNA in sperm with large nuclear vacuoles (LNV) selected by high-magnification. A total of 30 patients had fresh semen samples prepared by discontinuous concentration gradient. Sperm with normal nucleus (NN) and LNV were selected at 8400x magnification and placed in different slides. DNA fragmentation was determined by TUNEL assay. Denatured and double stranded DNA was identified by acridine orange fluorescence method. The percentage of DNA fragmentation in LNV sperm (29%) was significantly higher (P<0.001) than NN sperm (15.8%). Therefore, cleavage of genomic DNA in low molecular weight DNA fragments (mono and oligonucleosomes), and single strand breaks (nicks) in high molecular weight DNA occur more frequently in LNV. Identically, the percentage denatured stranded DNA in sperm with LNV (67.9%) was significantly higher (P <0.0001) than NN sperm (33%). The high level of denatured DNA in sperm with LNV suggests precocious decondensation and disaggregation of sperm chromatin fibers. Our results support an association between LNV sperm and DNA damage, and the routine selection and injection of morphological motile sperm at high magnification for ICSI. The adverse effect (DNA fragmentation or denaturation) leads to concern particularly about the possibility of iatrogenic transmission of genetic abnormalities. Copyright - SBRA - Sociedade Brasileira de Reprodução Assistida.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to assess the influence of cleaning pits and fissures with an aluminum oxide air abrasion system on the detection of occlusal caries in primary teeth using laser fluorescence (LF) and visual examination. Methods: The sample comprised 65 pit and fissure sites on extracted primary teeth suspected to be carious. The sites were submitted to 2 visual examinations (examiner JAR) and 2 LF readings (examiner TMV). Next, the occlusal surfaces were air-abraded and re-examined thereafter using both methods. The teeth were sectioned, and the histological analysis of the sites with a stereoscopic magnifying lens at X32 magnifi cation was used as the gold standard. Results: Cohen's kappa statistic for LF and visual examination were, respectively, 0.282/0.884 before and 0.896/0.905 after air abrasion. LF showed a sensitivity of 0.28 increasing to 0.49 and a specifi city of 0.50 increasing to 0.92. Visual examination showed sensitivity of 0.78 and specifi city of 0.73. Both increased after air abrasion. Conclusion: The findings suggest that cleaning pits and fissures with aluminum oxide air abrasion increased the accuracy of LF and visual examination for detection of occlusal caries in primary teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this clinical study was to evaluate and compare the performance of visual exam with use of the Nyvad criteria (visual examination - (VE)), interproximal radiography (BW), laser fluorescence device (DIAGNOdent Pen-DDPen), and their association in the diagnosis of proximal lesions in primary teeth. For this purpose, 45 children (n = 59 surfaces) of both sexes, aged between 5 and 9 years were selected, who presented healthy primary molars or primary molars with signs suggestive of the presence of caries lesions. The surfaces were clinically evaluated and coded according to the Nyvad criteria and immediately afterwards with the DDPen. Radiographic exam was performed only on the surfaces coded with Nyvad scores 2, 3, 5, or 6. Active caries lesions and/or those with discontinuous surfaces were restored, considering the depth of lesion as reference standard. Sensitivity, specificity, accuracy, and area under ROC curve were calculated for each technique and its associations. Visual exam with Nyvad criteria presented the highest specificity, accuracy, and area under ROC curve values. The DDPen presented the highest sensitivity values. Association with one or more methods resulted in an increase in specificity. The performance of visual, radiographic, and DDpen exams and their associations were good; however, the clinical examination with the Nyvad criteria was sufficient for the diagnosis of interproximal lesions in primary teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Because discomfort caused by different approximal caries detection methods can influence their performance, the assessment of this discomfort is important. Thus, this study aimed to evaluate the discomfort reported by children after the use of different diagnostic methods to detect approximal caries lesions in primary teeth: visual inspection, bitewing radiography, laser fluorescence (DIAGNOdent pen - LFpen) and temporary separation with orthodontic rubbers. Seventy-six children aged 4 to 12 years were examined using these methods. Their discomfort was assessed using the Wong-Baker scale and compared among the methods. Visual inspection caused less discomfort than did other methods. Radiography and the LFpen presented similar levels of discomfort. Older children reported higher discomfort using temporary separation, whereas younger children reported less discomfort with the LFpen. In conclusion, radiographic, temporary separation and LFpen methods provoke higher discomfort than visual inspection.