956 resultados para Keratoconus eyes
Resumo:
Perceptual multimedia quality is of paramount importance to the continued take-up and proliferation of multimedia applications: users will not use and pay for applications if they are perceived to be of low quality. Whilst traditionally distributed multimedia quality has been characterised by Quality of Service (QoS) parameters, these neglect the user perspective of the issue of quality. In order to redress this shortcoming, we characterise the user multimedia perspective using the Quality of Perception (QoP) metric, which encompasses not only a user’s satisfaction with the quality of a multimedia presentation, but also his/her ability to analyse, synthesise and assimilate informational content of multimedia. In recognition of the fact that monitoring eye movements offers insights into visual perception, as well as the associated attention mechanisms and cognitive processes, this paper reports on the results of a study investigating the impact of differing multimedia presentation frame rates on user QoP and eye path data. Our results show that provision of higher frame rates, usually assumed to provide better multimedia presentation quality, do not significantly impact upon the median coordinate value of eye path data. Moreover, higher frame rates do not significantly increase level of participant information assimilation, although they do significantly improve overall user enjoyment and quality perception of the multimedia content being shown.
Resumo:
Although the medieval papacy's stance towards the Jews is a well-established area of research, Jewish ideas about the papacy remain a surprisingly underdeveloped historical topic. This article explores such ideas through the genre of polemic and disputational literature. Jewish writers were keen to ensure the safety of their communities in western Europe and grateful for statements of papal protection. They fully acknowledged that popes had always played and would continue to play an important role in safeguarding their well-being and determining their future. Yet although contemporary and later writers often valued papal protection more highly than that of monarchs, emperors or clergy, they also knew that it had its carefully circumscribed limits. Furthermore, although they were respectful of the papacy's power, both spiritual and temporal, they were dismissive of the scriptural and theological formulations on which Christian claims for apostolic authority rested and highly critical of Christian beliefs about the papacy, in particular that of apostolic succession. Jewish ideas about both individual popes and the medieval papacy as an institution are therefore nuanced and complex; they deserve rigorous and wide-ranging investigation and it is hoped that this article will contribute to their better understanding.
Resumo:
Most approaches to Duffy’s work have been a feminist reading of poetry, focusing on the portrayal of women within the theoretical framework of feminism. However, little attention has been paid to the religious elements in Duffy’s work, something that Duffy herself has recognized. This essay will therefore focus on the centrality of religion in Duffy’s work, and will argue that her poems constitute an arena where religion is redefined and female experience and theology are reconciled. The poems under focus, “Delilah”, “Salome”, “Pilate’s wife”, “Pope Joan”, “Mrs Lazarous” and “Queen Herod” are examined in two separate sections: their portrayal of love and sexuality, and their portrayal of motherhood respectively, within the theoretical framework of feminist theology.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVOS: Avaliar o efeito da facoemulsificação com incisão em córnea clara no meridiano mais curvo sobre a magnitude do astigmatismo ceratométrico pré-operatório. Mapear a magnitude do astigmatismo cirurgicamente induzido por incisões nas posições nasal (N), temporal (T), temporal superior (TS) e temporal inferior (TI). MÉTODOS: Foi realizado estudo ceratométrico prospectivo em 48 olhos de 48 pacientes, submetidos a facoemulsificação com incisão do meridiano mais curvo. As medidas ceratométricas foram realizadas no pré-operatório e um mês após a realização da cirurgia. O astigmatismo cirurgicamente induzido foi determinado pelo método das coordenadas retangulares em 10 passos, modificado. RESULTADOS: Foram operados 21 olhos direitos e 27 olhos esquerdos e, de acordo com a posição das incisões em córnea clara, foram divididos em: 16 olhos N, 4 olhos T, 22 olhos TS, 6 olhos TI. A média da ametropia cilíndrica pré-operatória foi de 1,06D ± 0,65 e a pós-operatória de 0,89D ± 0,80. Houve diminuição estatisticamente significativa no astigmatismo corneal preexistente (p=0,016). A média total de astigmatismo cirurgicamente induzido foi de 0,94D ± 0,56. em relação aos grupos o astigmatismo cirurgicamente induzido foi de 1,06D ± 0,66 em N, 0,87D ± 0,20 em T, 0,95D ± 0,55 em TS e 0,61D ± 0,25 em TI. Não houve diferença estatística com relação ao astigmatismo cirurgicamente induzido nos grupos N, T, TS e TI (p=0,426). CONCLUSÃO: A técnica se mostrou efetiva na redução do astigmatismo ceratométrico pré-operatório. A média do astigmatismo cirurgicamente induzido foi de 1,06D ± 0,66 em N, 0,95D ± 0,55 em TS, 0,61D ± 0,25 em T e 0,87D ± 0,20 em TI.
Resumo:
Purpose: Synthetic hydroxyapatite and porous polyethylene (Polipore) spheres were placed in rabbits' eviscerated cavities to evaluate tissue reaction and volume maintenance.Methods. Fifty-six Norfolk albino rabbits underwent unilateral evisceration and implantation of synthetic hydroxyapatite (H group, 28 animals) or porous polyethylene spheres (P group, 28 animals). Postoperative reactions, animal behavior, and socket conditions were monitored. Light microscopy and morphometric evaluation with statistical analysis of the exenterated orbits were performed at 7, 15, 30, 60, 90, 120, and 180 days. Scanning electron microscopy was appraised 7, 60, and 180 days after surgery.Results: Two animals from the H group and 1 from the P group had extrusion 7 days after surgery. Throughout the experimental period, the synthetic hydroxyapatite caused more inflammation than the porous polyethylene material. Ingrowth in the sphere occurred 7 to 15 days after the surgery in both groups, and the tissue reaction became denser at approximate to60 to 90 days, when bony metaplasia began in the H group. Volume maintenance was better in the P group and with a smaller pseudocapsule surrounding the implanted sphere than in the H group.Conclusions: Clinical findings demonstrated mild inflammation inside the sphere and in the pseudocapsule surrounding it and better cavity volume maintenance in the P group animals. The authors consider porous polyethylene a more suitable material than synthetic hydroxyapatite for use in anophthalmic cavity reconstruction.