972 resultados para Intergranular corrosion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of investigations into the cause of an accelerated corrosion of copper sheathing and keel cooling pipe of a 36' wooden trawler are reported. The corrosion is attributed to the stray electric currents originating from the electrical wiring system. The sources of stray currents and the remedial measures have been suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study on arsenical creosote with reference to leaching, corrosion and anti-borer properties was carried out. Results showed that aging had very little effect on the preservative which suggested better fixation of the preservative into the wood. Corrosion of mild steel, galvanised iron, aluminium-magnesium alloy (M57S) and copper panels in the preservative was found to be negligible. Normal creosote and low temperature creosote of Regional Research Laboratory, Hyderabad, both fortified with arsenic trioxide resisted borer damage on wooden panels for a period of over five months in the port of Cochin. The performance of low temperature creosote fortified with arsenic was found to be equally satisfactory when compared to normal creosote fortified in the same manner. A loading of 208.6 Kgs/ml³ for Haldu (Adina cordifolia) and 138 Kgs/m³ for Mango (Mangifera indica) in the case of normal creosote and 177 Kgs/m³ for Mango the case of RRL creosote were found to be sufficient for treating the wood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although high tensile brassess of copper-zinc alloys (Manganese bronze) find extensive use in all marine applications, under aggressive sea-water, marine propellers cast out of such an alloy frequently suffer heavy corrosion damages due to dezincification. An interesting case history where a number of propellers have undergone dezincification in the Cochin backwaters is narrated in this paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some presently used anti-fouling materials contain metals and other compounds, which are toxic in the environment. Coating products are not always stable, and there is a resulting pollution hazard. In particular if surfaces are poorly prepared and manufactures' instructions are not closely followed the application of anti-fouling substances becomes pointless and dangerous. In addition the salinity, constant biological activity and suspended particles make seawater a highly corrosive material in its own right.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosion of ETP copper in natural seawater and putrid seawater has been studied. The corrosion rates and the sulphide content were monitored at regular intervals. In the absence of oxygen in the putrid media, the presence of sulphide favoured a reduction in the corrosion rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several experimental techniques have been used in order to characterize the properties of multifilamentary Bi-2223 / Ag tapes. Pristine samples were investigated by electrical resistivity, current-voltage characteristics and DC magnetic moment measurements. Much emphasis is placed on comparing transport (direct) and magnetic (indirect) methods for determining the critical current density as well as the irreversibility line and resolving usual lacks of consistency due to the difference in measurement techniques and data analysis. The effect of an applied magnetic field, with various strengths and directions, is also studied and discussed. Next, the same combination of experiments was performed on bent tapes in order to bring out relevant information regarding the intergranular coupling. A modified Brandt model taking into account different types of defects within the superconducting filaments is proposed to reconciliate magnetic and transport data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This communication aims at reporting the superconducting properties of Bi-2223/Ag tapes determined by using various measuring techniques. First, the original samples have been characterized by electrical resistance, AC susceptibility, and DC magnetization. The transport (intergranular) critical current vs. magnetic field was also determined at T = 77 K using pulsed currents up to 40 A. Next, the same combination of experiments was performed on bent tapes in order to bring out relevant information concerning the strength of the intergranular coupling. The results show that intergranular and intragranular currents differ by at least one order of magnitude. Finally, additional magnetic measurements were carried out in order to determine the anisotropy ratio Jc ab/Jc c, which was found to lie around 30. © 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new model is presented which describes the growth of the duplex layers of Fe3O4 on mild steel in high temperature, deoxygenated, neutral or alkaline aqueous solutions. It is shown that the layers grow by the ingress of water along oxide micropores to the metal-oxide interface and by the rate-limiting outward diffusion of Fe ions along oxide grain boundaries. The new model accounts for the observed temperature-dependence and pH-dependence of the corrosion, the morphology of inner and outer layer crystallites, the segregation of alloying elements, and the location of hydrogen evolution. The model can also be generalized to other steels and alloys. © 1989.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress corrosion studies of 50 Mn18Cr4 austenitic steel implanted with 120 keV N+, 100 keV Cr+, 200 keV and 400 keV Er+ ions were carried out by constant strain method in the nitrate solution. Surface composition and depth profiles of the implanted material were measured by AES sputter etching technique. The results exhibit that nitrogen implantation has no significant affection to the stress corrosion, but the chromium and erbium implantation has prolonged the incubation period of the stress corrosion cracking. (C) 1999 Kluwer Academic Publishers.