985 resultados para Inputs synaptiques


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, genetically encoded optical indicators have emerged as noninvasive tools of high spatial and temporal resolution utilized to monitor the activity of individual neurons and specific neuronal populations. The increasing number of new optogenetic indicators, together with the absence of comparisons under identical conditions, has generated difficulty in choosing the most appropriate protein, depending on the experimental design. Therefore, the purpose of our study was to compare three recently developed reporter proteins: the calcium indicators GCaMP3 and R-GECO1, and the voltage indicator VSFP butterfly1.2. These probes were expressed in hippocampal neurons in culture, which were subjected to patchclamp recordings and optical imaging. The three groups (each one expressing a protein) exhibited similar values of membrane potential (in mV, GCaMP3: -56 ±8.0, R-GECO1: -57 ±2.5; VSFP: -60 ±3.9, p = 0.86); however, the group of neurons expressing VSFP showed a lower average of input resistance than the other groups (in Mohms, GCaMP3: 161 ±18.3; GECO1-R: 128 ±15.3; VSFP: 94 ±14.0, p = 0.02). Each neuron was submitted to current injections at different frequencies (10 Hz, 5 Hz, 3 Hz, 1.5 Hz, and 0.7 Hz) and their fluorescence responses were recorded in time. In our study, only 26.7% (4/15) of the neurons expressing VSFP showed detectable fluorescence signal in response to action potentials (APs). The average signal-to-noise ratio (SNR) obtained in response to five spikes (at 10 Hz) was small (1.3 ± 0.21), however the rapid kinetics of the VSFP allowed discrimination of APs as individual peaks, with detection of 53% of the evoked APs. Frequencies below 5 Hz and subthreshold signals were undetectable due to high noise. On the other hand, calcium indicators showed the greatest change in fluorescence following the same protocol (five APs at 10 Hz). Among the GCaMP3 expressing neurons, 80% (8/10) exhibited signal, with an average SNR value of 21 ±6.69 (soma), while for the R-GECO1 neurons, 50% (2/4) of the neurons had signal, with a mean SNR value of 52 ±19.7 (soma). For protocols at 10 Hz, 54% of the evoked APs were detected with GCaMP3 and 85% with R-GECO1. APs were detectable in all the analyzed frequencies and fluorescence signals were detected from subthreshold depolarizations as well. Because GCaMP3 is the most likely to yield fluorescence signal and with high SNR, some experiments were performed only with this probe. We demonstrate that GCaMP3 is effective in detecting synaptic inputs (involving Ca2+ influx), with high spatial and temporal resolution. Differences were also observed between the SNR values resulting from evoked APs, compared to spontaneous APs. In recordings of groups of cells, GCaMP3 showed clear discrimination between activated and silent cells, and reveals itself as a potential tool in studies of neuronal synchronization. Thus, our results indicate that the presently available calcium indicators allow detailed studies on neuronal communication, ranging from individual dendritic spines to the investigation of events of synchrony in neuronal networks genetically defined. In contrast, studies employing VSFPs represent a promising technology for monitoring neural activity and, although still to be improved, they may become more appropriate than calcium indicators, since neurons work on a time scale faster than events of calcium may foresee

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New Linear Matrix Inequalities (LMI) conditions are proposed for the following problem, called Strictly Positive Real (SPR) synthesis: given a linear time-invariant plant, find a constant output feedback matrix Ko and a constant output tandem matrix F for the controlled system to be SPR. It is assumed that the plant has the number of outputs greater than the number of inputs. Some sufficient conditions for the solution of the problem are presented and compared. These results can be directly applied in the LMI-based design of Variable Structure Control (VSC) of uncertain plants. ©2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contiene aportes de la Secretaria a la Reunion Extraordinaria sobre desarrollo economico a realizarse en Ciudad de Mexico en enero de 1987.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sources and concentrations of aliphatic hydrocarbons (AHs) and polycyclic aromatic hydrocarbons (PAHs), faecal and biogenic sterols, and trace metals at 10 sampling sites located in Laranjeiras Bay, a large Environmental Protection Area in the southern Atlantic region of Brazil, were determined to assess the sources of organic matter and the contamination status of estuarine sediments. Organic compounds were determined by GC-FID and GC-MS, and ICP-OES was used to evaluate trace metals. The total AHs concentration ranged from 0.28 to 8.19 mu g g(-1), and n-C-29 and n-C-31 alkanes were predominant, indicating significant inputs from higher terrestrial plants. Unresolved complex mixtures (UCM) were not detected at any site, suggesting that the study area was not significantly contaminated by fossil fuels. The total PAH concentration varied from 3.85 to 89.2 ng g(-1). The ratio between selected PAH isomers showed that combustion of biomass, coal, and petroleum is the rnain source of PAHs in the study area. The concentrations of the faecal sterols coprostanol and epicoprostanol were below the detection limits, suggesting that sewage was not a significant contributor to sedimentary organic matter. The concentrations of the trace metals (As, Cr, Cu, Ni, Pb and Zn) were low, except near sites located at the mouths of rivers that discharge into the study area and near urbanised regions (Paranagua city and the adjoining harbour). In general, the concentrations of PAHs were below the threshold effect concentrations (TEL) levels. Although the As, Cr and Ni concentrations were above the TEL levels, the study area can be considered as preserved from human activities.