973 resultados para Implantable Infusion pumps
Resumo:
Candida albicans is one of the most important opportunistic fungal pathogens. It can cause serious fungal diseases in immunocompromised patients, including those with cancer. Treatment failures due to the emergence of drug-resistant C. albicans strains have become a serious clinical problem. Resistance incidents were often mediated by fungal efflux pumps which are closely related to the human ABC transporter P-glycoprotein (P-gp). P-gp is often overexpressed in cancer cells and confers resistance to many cytotoxic drugs. We examined whether cytotoxic drugs commonly used for cancer treatment (doxorubicin and cyclophosphamide) could alter the expression of genes responsible for the development of fluconazole resistance in Candida cells in the way they can influence homologous genes in cancer cell lines. ABC transporters (CDR1 and CDR2) and other resistance genes (MDR1 and ERG11) were tested by real-time PCR for their expression in C. albicans cells at the mRNA level after induction by antineoplastic drugs. The results were confirmed by a lacZ gene reporter system and verified at the protein level using GFP and immunoblotting. We showed that doxorubicin is a potent inducer of CDR1/CDR2 expression in C. albicans at both the mRNA and protein level and thus causes an increase in fluconazole MIC values. However, cyclophosphamide, which is not a substrate of human P-gp, did not induce ABC transporter expression in C. albicans. Neither doxorubicin nor cyclophosphamide could influence the expression of the other resistance genes (MDR1 and ERG11). The induction of CDR1/CDR2 by doxorubicin in C. albicans and the resulting alteration of antifungal susceptibility might be of clinical relevance for the antifungal treatment of Candida infections occurring after anticancer chemotherapy with doxorubicin.
Resumo:
RESUME : La ghrelin est un peptide sécrété par l'estomac jouant un rôle important dans le maintien de l'homéostasie énergétique. Ses taux plasmatiques sont augmentés durant des périodes prolongées de déficit nutritionnel. Une carence énergétique étant souvent associée à une inhibition de l'axe hypothalamo-hypophyso-ovarien, nous avons postulé que l'augmentation des taux circulant de ghrelin pourrait diminuer l'activité du générateur hypothalamique de pulsations de GnRH. Le protocole expérimental impliquait des singes rhésus adultes ovariectomisés (n=6) qui dans un premier temps recevaient durant 3 heures une perfusion de solution saline physiologique afin de mesurer la sécrétion pulsatile de LH à l'état basai. L'expérience se poursuivait alors durant 5 heures par une perfusion intraveineuse de ghrelin humaine (un bolus de 100-150µg suivi par 100-150µg/h) ou le maintien de la perfusion de solution saline physiologique. Des échantillons de sang étaient prélevés toutes les 15 minutes. La perfusion de ghrelin a augmenté ses taux plasmatiques de 2.9 fois par rapport aux valeurs de base. L'administration de ghrelin a significativement diminué la fréquence des pulsations de LH (de 0.89±0.07/h à l'état basai à 0.57±0.10/h durant la perfusion de ghrelin; p<0.05, moyenne±SEM), alors que la fréquence des pulsations de LH est restée inchangée durant la perfusion de solution physiologique. L'amplitude des pulsations de LH n'a pas été modifiée. La ghrelin a également stimulé de manière significative la sécrétion de cortisol et d'hormone de croissance, mais n'a toutefois pas eu d'effet sur la sécrétion de leptin. En conclusion, la ghrelin peut inhiber l'activité du générateur de pulsations de GnRH et pourrait ainsi contribuer à l'inhibition de l'axe de la reproduction observée durant des périodes de carence nutritionnelle, comme notamment chez les patientes souffrant d'anorexie mentale. La ghrelin peut également activer l'axe hypothalamo-hypophyso-surrénalien. Le lien dans cette situation entre l'activation de l'axe surrénalien et l'inhibition de l'axe de la reproduction reste à démontrer. ABSTRACT: Ghrelin, a nutrition-related peptide secreted by the stomach, is elevated during prolonged food deprivation. Because undernutrition is often associated with a suppressed reproductive axis, we have postulated that increasing peripheral ghrelin levels will decrease the activity of the GnRH pulse generator. Adult ovariectomized rhesus monkeys (n = 6) were subjected to a 5-h iv human ghrelin (100- to 150µg bolus followed by 100-150 µg/h) or saline infusion, preceded by a 3-h saline infusion to establish baseline pulsatile LH release. Blood samples were collected at 15-min intervals throughout the experiment. Ghrelin infusion increased plasma ghrelin levels 2.9-fold of baseline. Ghrelin significantly decreased LH pulse frequency (from 0.89 ± 0.07/h in baseline to 0.57 ± 0.10/h during ghrelin infusion; P<0.05, mean ± SEM), whereas LH pulse frequency remained unchanged during saline treatment. LH pulse amplitude was not affected. Ghrelin also significantly stimulated both Cortisol and GH release, but had no effect on leptin. We conclude that ghrelin can inhibit GnRH pulse activity and may thereby mediate the suppression of the reproductive system observed in conditions of undernutrition, such as in anorexia nervosa. Ghrelin also activates the adrenal axis, but the relevance of this to the inhibition of GnRH pulse frequency remains to be established.
Resumo:
The implantable loop recorder developed by Medtronic (Reveal plus) is a small device inserted subcutaneously under local anesthesia in patients with syncope of unexplained origin. This device enables a single lead-ECG recording and has autonomy of two years. Memories are activated during episodes of bradycardia or tachycardia, either automatically or manually. Several studies have shown a high diagnostic rate reaching 50% and demonstrated its cost-effectiveness. There is also a significant reduction in syncopal episodes and a higher quality of life score in patients with syncope of unexplained origin.
Resumo:
The brain uses lactate produced by glycolysis as an energy source. How lactate originated from the blood stream is used to fuel brain metabolism is not clear. The current study measures brain metabolic fluxes and estimates the amount of pyruvate that becomes labeled in glial and neuronal compartments upon infusion of [3-(13) C]lactate. For that, labeling incorporation into carbons of glutamate and glutamine was measured by (13) C magnetic resonance spectroscopy at 14.1 T and analyzed with a two-compartment model of brain metabolism to estimate rates of mitochondrial oxidation, glial pyruvate carboxylation, and the glutamate-glutamine cycle as well as pyruvate fractional enrichments. Extracerebral lactate at supraphysiological levels contributes at least two-fold more to replenish the neuronal than the glial pyruvate pools. The rates of mitochondrial oxidation in neurons and glia, pyruvate carboxylase, and glutamate-glutamine cycles were similar to those estimated by administration of (13) C-enriched glucose, the main fuel of brain energy metabolism. These results are in agreement with primary utilization of exogenous lactate in neurons rather than astrocytes. © 2014 Wiley Periodicals, Inc.
Resumo:
Tässä diplomityössä käsitellään erikoispumppujen korjausprosessia teollisuuspumppujen korjauksiin erikoistuneessa konepajassa. Työn pääasiallinen tarkoitus on tuotantoprosessin kehittäminen ja tuotantovaiheiden esitteleminen. Tavoitteen taustalla on pyrkimys entisestään parantaa palvelukykyä ja asiakastyytyväisyyttä.Kolme eri keinoa päätavoitteen saavuttamiseksi ovat tuotannon suunnittelun ja ohjauksen kehittäminen, työssä käsiteltyjen pumpputyyppien korjausprosessien läpäisyaikojen lyhentäminen sekä korjausvaiheiden määrittely ja esittely vaihe vaiheelta. Työssä käsiteltyjä erikoispumpputyyppejä ovat imupumput, monijaksopumput sekä pysty/potkuripumput.Tuotannonsuunnittelun ja -ohjauksen kehittämiseksi sekä läpäisyaikojen lyhentämiseksi työssä etsittiin vaihtoehtoisia toimintatapoja. Kolmas tavoite, eli korjausvaiheiden määrittely, toteutettiin esittelemällä korjausprosessin vaiheet käsitellyillä pumpputyypeillä.Tuloksena saatiin keinoja tuotannon suunnittelun ja hallinnan kehittämiseksi. Useimmat keinot koskevat toimintatapojen selkiyttämistä. Myös keinoja läpäisyaikojen lyhentämiseksi löydettiin. Tietyllä imupumpputyypillä ja -koolla läpäisyajan lyheneminen oli 25 % ja osalla monijaksopumpuista jopa 75 %. Tulokset saavutetaan varastoimalla tiettyjä komponentteja, joilla on pitkä valmistus- tai korjausaika. Pysty/potkuripumppujen korjauksen läpäisyaikaa ei saatu lyhennettyä työn rajausten puitteissa Näiden tulosten lisäksi korjausprosessin toimintatavat määriteltiin.
Resumo:
BACKGROUND: Magnetic resonance imaging (MRI) of patients with conventional implantable cardioverter-defibrillators (ICD) is contraindicated. OBJECTIVES: This multicenter, randomized trial evaluated safety and efficacy of a novel ICD system specially designed for full-body MRI without restrictions on heart rate or pacing dependency. The primary safety objective was >90% freedom from MRI-related events composite endpoint within 30 days post-MRI. The primary efficacy endpoints were ventricular pacing capture threshold and ventricular sensing amplitude. METHODS: Subjects received either a single- or dual-chamber ICD. In a 2:1 randomization, subjects either underwent MRI at 1.5-T of the chest, cervical, and head regions to maximize radiofrequency exposure up to 2 W/kg specific absorption rate and gradient field exposure to 200 T/m/s per axis (MRI group, n = 175), or they underwent a 1-h waiting period without MRI (control group, n = 88). A subset of MRI patients underwent ventricular fibrillation induction testing post-MRI to characterize defibrillation function. RESULTS: In 42 centers, 275 patients were enrolled (76% male, age 60.4 ± 13.8 years). The safety endpoint was met with 100% freedom from the composite endpoint (p < 0.0001). Both efficacy endpoints were met with minimal differences in the proportion of MRI and control patients who demonstrated a ≤0.5 V increase in ventricular pacing capture threshold (100% MRI vs. 98.8% control, noninferiority p < 0.0001) or a ≤50% decrease in R-wave amplitude (99.3% MRI vs. 98.8% control, noninferiority p = 0.0001). A total of 34 ventricular tachyarrhythmia/ventricular fibrillation episodes (20 induced; 14 spontaneous) occurred in 24 subjects post-MRI, with no observed effect on sensing, detection, or treatment. CONCLUSIONS: This is the first randomized clinical study of an ICD system designed for full-body MRI at 1.5-T. These data support that the system is safe and the MRI scan does not adversely affect electrical performance or efficacy. (Confirmatory Clinical Trial of the Evera MRI System for Conditionally-Safe MRI Access; NCT02117414).
Resumo:
In machine design we always want to save space, save energy and produce as much power as possible. We can often reduce accelerations, inertial loads and energy consumption by changing construction. In this study the old cardan gear mechanism (hypocycloid mechanism) has been compared with the conventional slider-crank mechanism in air pumps and four-stroke engines. Comprehensive Newtonian dynamics has been derived for the both mechanisms. First the slidercrank and the cardan gear machines have been studied as lossless systems. Then the friction losses have been added to the calculations. The calculation results show that the cardan gear machines can be more efficient than the slider-crank machines. The smooth running, low mass inertia, high pressures and small frictional power losses make the cardan gear machines clearly better than the slider-crank machines. The dynamic tooth loads of the original cardan gear construction do not rise very high when the tooth clearances are kept tight. On the other hand the half-size crank length causes high bearing forces in the cardan gear machines. The friction losses of the cardan gear machines are generally quite small. The mechanical efficiencies are much higher in the cardan gear machines than in the slider-crank machines in normal use. Crankshaft torques and power needs are smaller in the cardan gear air pumps than in the equal slider-crank air pumps. The mean crankshaft torque and the mean output power are higher in the cardan gear four-stroke engines than in the slider-crank four-stroke engines in normal use. The cardan gear mechanism is at its best, when we want to build a pump or an engine with a long connecting rod (≈ 5⋅crank length) and a thin piston (≈ 1.5⋅crank length) rotating at high angular velocity and intermittently high angular acceleration. The cardan gear machines can be designed also as slide constructions without gears. Suitable applications of the cardan gear machines are three-cylinder half-radial engines for motorcycles, sixcylinder radial engines for airplanes and six-cylinder double half-radial engines for sport cars. The applied equations of Newtonian dynamics, comparative calculations, calculation results (tables, curves and surface plots) and recommendations presented in this study hold novelty value and are unpublished before. They have been made and written by the author first time in this study.
Resumo:
Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.
Resumo:
Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.
Resumo:
PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.