458 resultados para I2


Relevância:

10.00% 10.00%

Publicador:

Resumo:

碳硅钙石—Ca_7[Si_6O_(18)] [CO_3]·2H_2O是钙的碳酸盐硅酸盐矿物的第三个成员(Pluth and Smith, 1973)。前人曾做过某些碳硅钙石的一般矿物学研究(McConnell, 1955; Murdoch, 1955和曹正民等,1987)。Pluth和Smith (1973)利用X射线四园衍射仪进行结构测定,但未能确定其空间群,给出的结果是I2/m或Im。与此相关,他们未能确定该矿物结构中CO_3的有序或无序;对Ca的配位亦不明了。另外,前人对Ca的碳酸盐硅酸盐矿物未作系统比较。1972年在安徽省濉溪县邹楼铁矿床的钻钆岩芯中也发现了碳硅钙石。作者对该地碳硅钙石样品进行了矿物学、晶体结构和晶体化学研究。作者对采自安徽的碳硅钙品进行了一系列矿物学研究后发现,本文碳硅钙石的一般矿物学特征和前人研究结果基本相同。这说明:(1)本文样品确为碳硅钙石;(2)不同产地和产状的碳硅钙石的矿物学特征相同,由此进一步反映该矿物具有极苛刻的生成条件。作者发现前人对碳硅钙石X射线粉晶衍射线条的指标化有不少错误或不足,并予以纠正。通过晶体结构测定与修正,作用确认碳硅钙石的空间群应为Cm。结构中CO_3有序。它属于等腰三角形几何构型;并呈“受压”迹象。该结构中SiO_4四面体连成稳定的Si_6O_(18)六元环。碳硅钙石结构中水以结晶小的形式存在。该结构中存在氢键。该结构中共有四种Ca的配位多面体;Cal的配位数为8,Ca2, Ca3和Ca4配位数为6。Ca-0多面体相互以复杂的共棱方式连接成层。层间夹有CO_3, Si_6O_(18)和H_2O。Ca-0多面体畸变程度不同。碳硅钙石的晶体化学式应表示为Ca~([8])Ca~([6])_6[Si~([4])_6O_(18)] [C~([3])O_3]·2H_2O。作者发现,可以用配位中心原子(或离子)的键价和讨论配位多面体的结构畸变;并证明对于中心原子(或离子)、配位原子(或离子)、配位数及R(平均键长)均相同的几个配位多面体,畸变程度越强,中心原子(或离子)的键价和越大。此外,作者认识到,离子键和共价键的判别在键价和上也有所体现。根据晶体结构信息,作者对碳硅钙石的某些矿物学特征进行了满意的解释,从而使两者得到相互印证。通过认真全面的比较,作者发现碳硅钙石及其类似古物——Ca的碳酸盐硅酸盐矿物是复杂多样的。除去具有相同或相近的元素组成和地质产状外,它们几乎不再有共同点。碳硅钙石均产自火成岩和沉积岩的接触带。它的结晶温压范围是非常狭窄的。这也正是碳硅钙石等矿物在自然界比较罕见的重要原因。本文碳硅钙石结晶于较晚期的低温热液阶段;并且直接结晶于溶液环境。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The propagation of surface plasmon polaritons (SPP's) is studied using a photon scanning tunneling microscope (PSTM) and conventional attenuated total reflection (ATR). The PSTM experiment uses localized (focused beam) launching or SPP's at a wavelength of 632.8 nm. Propagation of the SPP is observed as an exponentially decaying tail beyond the launch site acid the 1/e propagation length is measured directly for a series of Ag films of different thicknesses. The ATR measurements are used to characterize the thin film optical and thickness parameters, revealing, notably, the presence of a contaminating adlayer of Ag2S of typical dielectric function, 8.7 + i2.7, and thickness 1-2 nm. Values of the SPP propagation length, based on the ATR- derived film parameters used in the four-media implicit SPP dispersion relation, show very good agreement with those based on the PSTM images for the case of undercoupled or optimally coupled SPP modes. The observed propagation lengths are quantitatively analyzed taking explicit account of additional intrinsic damping due to the growth of the Ag2S layer and of reradiation of the SPP back into the prism outside the launch site. Finally, the PSTM images show excellent SPP beam confinement in the original propagation direction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Greater dietary intakes of n–3 long-chain polyunsaturated fatty acids (n–3 PUFAs) may be beneficial for depressed mood. Objective: This study aimed to systematically review all published randomized controlled trials investigating the effects of n–3 PUFAs on depressed mood. Design: Eight medical and health databases were searched over all years of records until June 2006 for trials that exposed participants to n–3 PUFAs or fish, measured depressed mood, were conducted on human participants, and included a comparison group. Results: Eighteen randomized controlled trials were identified; 12 were included in a meta-analysis. The pooled standardized difference in mean outcome (fixed-effects model) was 0.13 SDs (95% CI: 0.01, 0.25) in those receiving n–3 PUFAs compared with placebo, with strong evidence of heterogeneity (I2 = 79%, P <0.001). The presence of funnel plot asymmetry suggested that publication bias was the likely source of heterogeneity. Sensitivity analyses that excluded one large trial increased the effect size estimates but did not reduce heterogeneity. Metaregression provided some evidence that the effect was stronger in trials involving populations with major depression—the difference in the effect size estimates was 0.73 (95% CI: 0.05, 1.41; P = 0.04), but there was still considerable heterogeneity when trials that involved populations with major depression were pooled separately (I2 = 72%, P <0.001). Conclusions: Trial evidence that examines the effects of n–3 PUFAs on depressed mood is limited and is difficult to summarize and evaluate because of considerable heterogeneity. The evidence available provides little support for the use of n–3 PUFAs to improve depressed mood. Larger trials with adequate power to detect clinically important benefits are required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Children born by Caesarean section have modified intestinal bacterial colonization and consequently may have an increased risk of developing asthma under the hygiene hypothesis. The results of previous studies that have investigated the association between Caesarean section and asthma have been conflicting.

Objective: To review published literature and perform a meta-analysis summarizing the evidence in support of an association between children born by Caesarean section and asthma.

Methods: MEDLINE, Web Science, Google Scholar and PubMed were searched to identify relevant studies. Odds ratio (OR) and 95% confidence interval (CI) were calculated for each study from the reported prevalence of asthma in children born by Caesarean section and in control children. Meta-analysis was then used to derive a combined OR and test for heterogeneity in the findings between studies.

Results: Twenty-three studies were identified. The overall meta-analysis revealed an increase in the risk of asthma in children delivered by Caesarean section (OR=1.22, 95% CI 1.14, 1.29). However, in this analysis, there was evidence of heterogeneity (I2=46%) that was statistically significant (P<0.001). Restricting the analysis to childhood studies, this heterogeneity was markedly decreased (I2=32%) and no longer attained statistical significance (P=0.08). In these studies, there was also evidence of an increase (P<0.001) in the risk of asthma after Caesarean section (OR=1.20, 95% CI 1.14, 12.6).

Conclusion: In this meta-analysis, we found a 20% increase in the subsequent risk of asthma in children who had been delivered by Caesarean section.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the role of plasma total homocysteine (tHcy) concentrations and homozygosity for the thermolabile variant of the methylenetetrahydrofolate reductase (MTHFR) C677T gene as risk factors for retinal vascular occlusive disease.

Design: Retinal vein occlusion (RVO) is an important cause of vision loss. Early meta-analyses showed that tHcy was associated with an increased risk of RVO, but a significant number of new studies have been published. Participants and/or Controls: RVO patients and controls.

Methods: Data sources included MEDLINE, Web of Science, and PubMed searches and searching reference lists of relevant articles and reviews. Reviewers searched the databases, selected the studies, and then extracted data. Results were pooled quantitatively using meta-analytic methods.

Main Outcome Measures: tHcy concentrations and MTHFR genotype.

Results: There were 25 case-control studies for tHcy (1533 cases and 1708 controls) and 18 case-control studies for MTHFR (1082 cases and 4706 controls). The mean tHcy was on average 2.8 mol/L (95% confidence
interval [CI], 1.8 –3.7) greater in the RVO cases compared with controls, but there was evidence of between-study heterogeneity (P0.001, I2 93%). There was funnel plot asymmetry suggesting publication bias. There was no evidence of association between homozygosity for the MTHFR C677T genotype and RVO (odds ratio [OR] 1.20; 95% CI, 0.84–1.71), but again marked heterogeneity (P 0.004, I2 53%) was observed.

Conclusions: There was some evidence that elevated tHcy was associated with RVO, but not homozygosity for the MTHFR C677T genotype. Both analyses should be interpreted cautiously because of marked heterogeneity between the study estimates and possible effect of publication bias on the tHcy findings.

Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract
Background: Automated closed loop systems may improve adaptation of the mechanical support to a patient's ventilatory needs and
facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of
ventilation.

Objectives: To compare the duration of weaning from mechanical ventilation for critically ill ventilated adults and children when managed
with automated closed loop systems versus non-automated strategies. Secondary objectives were to determine differences
in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.

Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 2); MEDLINE (OvidSP) (1948 to August 2011); EMBASE (OvidSP) (1980 to August 2011); CINAHL (EBSCOhost) (1982 to August 2011); and the Latin American and Caribbean Health Sciences Literature (LILACS). In addition we received and reviewed auto-alerts for our search strategy in MEDLINE, EMBASE, and CINAHL up to August 2012. Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles.

Selection criteria: We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning
strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an intensive care unit (ICU).

Data collection and analysis: Two authors independently extracted study data and assessed risk of bias. We combined data into forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria.

Main results: Pooled data from 15 eligible trials (14 adult, one paediatric) totalling 1173 participants (1143 adults, 30 children) indicated that automated closed loop systems reduced the geometric mean duration of weaning by 32% (95% CI 19% to 46%, P =0.002), however heterogeneity was substantial (I2 = 89%, P < 0.00001). Reduced weaning duration was found with mixed or
medical ICU populations (43%, 95% CI 8% to 65%, P = 0.02) and Smartcare/PS™ (31%, 95% CI 7% to 49%, P = 0.02) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (17%, 95% CI 8% to 26%) and ICU length of stay (LOS) (11%, 95% CI 0% to 21%). There was no difference in mortality rates or hospital LOS. Overall the quality of evidence was high with the majority of trials rated as low risk.

Authors' conclusions: Automated closed loop systems may result in reduced duration of weaning, ventilation, and ICU stay. Reductions are more
likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized
controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several short-term studies have investigated the effects of a vegetable oil emulsion on subsequent food intake, although findings have been inconsistent. This work aimed to review all studies, and investigate differences in study outcomes based on methodology. All known studies were identified. Data were abstracted from published studies (n = 7). Details of unpublished studies were gained from investigators/sponsors (n = 5), or were unavailable for reasons of confidentiality (n = 4). Available data were combined using meta-analyses. A combined appetite suppressant effect of the emulsion compared with control was found for test meal intake at approximately 4, 12 and 36 h post-treatment: smallest combined mean difference (random effects model) = 0.53 MJ (95% confidence interval 0.20, 0.86), P < 0.01. However, considerable heterogeneity (variability) between study results was also found (smallest I2 = 94%, P < 0.01), questioning the predictive validity of the above findings. Meta-regression suggested this heterogeneity to be related to differences in the processed nature of the product, treatment dose and in particular year of study (smallest B = 0.54, 95% confidence interval 0.06, 1.03, P = 0.04), although again heterogeneity was found. The only consistent finding was a lack of effect on food intake 4 h post-preload in studies conducted after 2003. These results suggest a small but inconsistent appetite suppressant effect of the vegetable oil emulsion. However, due to the large heterogeneity, no definitive conclusions can be drawn.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The diffusion-controlled response and recovery behaviour of a naked optical film sensor (i.e., with no protective membrane) with a hyperbolic-type response [i.e., S0/S = (1 + Kc), where S is the measured value of the absorbance or luminescence intensity of one form of the sensor dye in the presence of the analyte, S0 is the observed value of S in the absence of analyte and K is a constant] to changes in analyte concentration, c, in a system under test is approximated using a simple model, and described more accurately using a numerical model; in both models it is assumed that the system under test represents an infinite reservoir. Each model predicts the variations in the response and recovery times of such an optical sensor, as a function of the final external analyte concentration, the film thickness (I) and the analyte diffusion coefficient (D). From an observed signal versus time profile for a naked optical film sensor it is shown how values for K and D/I2 can be extracted using the numerical model. Both models provide a qualitative description of the often cited asymmetric nature of the response and recovery for hyperbolic-type response naked optical film sensors. It is envisaged that the models will help in the interpretation of the response and recovery behaviour exhibited by many naked optical film sensors and might be especially apposite when the analyte is a gas.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Despite differences in how it is defined, there is a general consensus amongst clinicians and researchers that the sexual abuse of children and adolescents (’child sexual abuse’) is a substantial social problem worldwide. The effects of sexual abuse manifest in a wide range of symptoms, including fear, anxiety, post-traumatic stress disorder and various externalising and internalising behaviour problems, such as inappropriate sexual behaviours. Child sexual abuse is associated with increased risk of psychological problems in adulthood. Cognitive-behavioural approaches are used to help children and their non-offending or ’safe’ parent tomanage the sequelae of childhood sexual abuse. This review updates the first Cochrane review of cognitive-behavioural approaches interventions for children who have been sexually abused, which was first published in 2006.

Objectives: To assess the efficacy of cognitive-behavioural approaches (CBT) in addressing the immediate and longer-term sequelae of sexual abuse on children and young people up to 18 years of age.

Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2011 Issue 4); MEDLINE (1950 to November Week
3 2011); EMBASE (1980 to Week 47 2011); CINAHL (1937 to 2 December 2011); PsycINFO (1887 to November Week 5 2011); LILACS (1982 to 2 December 2011) and OpenGrey, previously OpenSIGLE (1980 to 2 December 2011). For this update we also searched ClinicalTrials.gov and the International Clinical Trials Registry Platform (ICTRP).

Selection criteria: We included randomised or quasi-randomised controlled trials of CBT used with children and adolescents up to age 18 years who had experienced being sexually abused, compared with treatment as usual, with or without placebo control.

Data collection and analysis: At least two review authors independently assessed the eligibility of titles and abstracts identified in the search. Two review authors independently extracted data from included studies and entered these into Review Manager 5 software. We synthesised and presented data in both written and graphical form (forest plots).

Main results: We included 10 trials, involving 847 participants. All studies examined CBT programmes provided to children or children and a nonoffending parent. Control groups included wait list controls (n = 1) or treatment as usual (n = 9). Treatment as usual was, for the most part, supportive, unstructured psychotherapy. Generally the reporting of studies was poor. Only four studies were judged ’low risk of bias’ with regards to sequence generation and only one study was judged ’low risk of bias’ in relation to allocation concealment. All studies were judged ’high risk of bias’ in relation to the blinding of outcome assessors or personnel; most studies did not report on these, or other issues of bias. Most studies reported results for study completers rather than for those recruited.

Depression, post-traumatic stress disorder (PTSD), anxiety and child behaviour problems were the primary outcomes. Data suggest that CBT may have a positive impact on the sequelae of child sexual abuse, but most results were not statistically significant. Strongest evidence for positive effects of CBT appears to be in reducing PTSD and anxiety symptoms, but even in these areas effects tend to be 'moderate’ at best. Meta-analysis of data from five studies suggested an average decrease of 1.9 points on the Child Depression Inventory immediately after intervention (95% confidence interval (CI) decrease of 4.0 to increase of 0.4; I2 = 53%; P value for heterogeneity = 0.08), representing a small to moderate effect size. Data from six studies yielded an average decrease of 0.44 standard deviations on a variety of child post-traumatic stress disorder scales (95% CI 0.16 to 0.73; I2 = 46%; P value for heterogeneity = 0.10). Combined data from five studies yielded an average decrease of 0.23 standard deviations on various child anxiety scales (95% CI 0.3 to 0.4; I2=0%; P value for heterogeneity = 0.84). No study reported adverse effects.

Authors’ conclusions: The conclusions of this updated review remain the same as those when it was first published. The review confirms the potential of CBT to address the adverse consequences of child sexual abuse, but highlights the limitations of the evidence base and the need for more carefully conducted and better reported trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several studies have assessed changes in frequency of -174 interleukin (IL)-6 single nucleotide polymorphism (SNP) with age. If IL-6 tracks with disability and age-related diseases, then there should be reduction, in the oldest old, of the frequency of homozygous GG subjects, who produce higher IL-6 levels. However, discordant results have been obtained. To explore the relationship between this polymorphism and longevity, we analyzed individual data on long-living subjects and controls from eight case-control studies conducted in Europeans, using meta-analysis. There was no significant difference in the IL-6 genotype between the oldest old and controls (Odds Ratio [OR]=0.96; 95% C.I.: 0.77-1.20; p=0.71), but there was significant between-study heterogeneity (I2=55.5%). In a subgroup analyses when male centenarians from the three Italian studies were included, the frequency of the IL-6 -174 GG genotype was significantly lower than the other genotypes (OR=0.49; 95% C.I.: 0.31-0.80; p=0.004), with no evidence of heterogeneity (I2=0%). Our data supports a negative association between the GG genotype of IL-6 SNP and longevity in Italian centenarians, with males who carry the genotype being two times less likely to reach extreme old age compared with subjects carrying CC or CG genotypes. These findings were not replicated in other European groups suggesting a possible interaction between genetics, sex and environment in reaching longevity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An exceptional gold-hilted sword, presumably from the province of Guadalajara, which today is kept in Madrid at the National Museum of Archaeology, has usually been treated as an isolated find. However, early references to this piece, when it was kept in the Rodriguez Bauza collection, would seem to indicate that it may have formed part of a hoard together with two other swords, one of which apparently can be associated with fragments of a second hilt-cover of gold sheet, acquired originally with the complete sword. Furthermore, during re-restoration of the first sword, traces left on its surface from at least two different hilts, demonstrated that the current gold-covered design has to be considered a secondary modification. While some Mycenean influence in the design of these weapons and their ornaments cannot be ruled out, for technical reasons a production on the Meseta at least of the gold sheets seems more likely than in the Southeast, where the ElArgarculture is usually more readily associated with the diffusion of Aegean elements.