957 resultados para Human eye


Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the progress of computer technology, computers are expected to be more intelligent in the interaction with humans, presenting information according to the user's psychological and physiological characteristics. However, computer users with visual problems may encounter difficulties on the perception of icons, menus, and other graphical information displayed on the screen, limiting the efficiency of their interaction with computers. In this dissertation, a personalized and dynamic image precompensation method was developed to improve the visual performance of the computer users with ocular aberrations. The precompensation was applied on the graphical targets before presenting them on the screen, aiming to counteract the visual blurring caused by the ocular aberration of the user's eye. A complete and systematic modeling approach to describe the retinal image formation of the computer user was presented, taking advantage of modeling tools, such as Zernike polynomials, wavefront aberration, Point Spread Function and Modulation Transfer Function. The ocular aberration of the computer user was originally measured by a wavefront aberrometer, as a reference for the precompensation model. The dynamic precompensation was generated based on the resized aberration, with the real-time pupil diameter monitored. The potential visual benefit of the dynamic precompensation method was explored through software simulation, with the aberration data from a real human subject. An "artificial eye'' experiment was conducted by simulating the human eye with a high-definition camera, providing objective evaluation to the image quality after precompensation. In addition, an empirical evaluation with 20 human participants was also designed and implemented, involving image recognition tests performed under a more realistic viewing environment of computer use. The statistical analysis results of the empirical experiment confirmed the effectiveness of the dynamic precompensation method, by showing significant improvement on the recognition accuracy. The merit and necessity of the dynamic precompensation were also substantiated by comparing it with the static precompensation. The visual benefit of the dynamic precompensation was further confirmed by the subjective assessments collected from the evaluation participants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The goal of my Ph.D. thesis is to enhance the visualization of the peripheral retina using wide-field optical coherence tomography (OCT) in a clinical setting.

OCT has gain widespread adoption in clinical ophthalmology due to its ability to visualize the diseases of the macula and central retina in three-dimensions, however, clinical OCT has a limited field-of-view of 300. There has been increasing interest to obtain high-resolution images outside of this narrow field-of-view, because three-dimensional imaging of the peripheral retina may prove to be important in the early detection of neurodegenerative diseases, such as Alzheimer's and dementia, and the monitoring of known ocular diseases, such as diabetic retinopathy, retinal vein occlusions, and choroid masses.

Before attempting to build a wide-field OCT system, we need to better understand the peripheral optics of the human eye. Shack-Hartmann wavefront sensors are commonly used tools for measuring the optical imperfections of the eye, but their acquisition speed is limited by their underlying camera hardware. The first aim of my thesis research is to create a fast method of ocular wavefront sensing such that we can measure the wavefront aberrations at numerous points across a wide visual field. In order to address aim one, we will develop a sparse Zernike reconstruction technique (SPARZER) that will enable Shack-Hartmann wavefront sensors to use as little as 1/10th of the data that would normally be required for an accurate wavefront reading. If less data needs to be acquired, then we can increase the speed at which wavefronts can be recorded.

For my second aim, we will create a sophisticated optical model that reproduces the measured aberrations of the human eye. If we know how the average eye's optics distort light, then we can engineer ophthalmic imaging systems that preemptively cancel inherent ocular aberrations. This invention will help the retinal imaging community to design systems that are capable of acquiring high resolution images across a wide visual field. The proposed model eye is also of interest to the field of vision science as it aids in the study of how anatomy affects visual performance in the peripheral retina.

Using the optical model from aim two, we will design and reduce to practice a clinical OCT system that is capable of imaging a large (800) field-of-view with enhanced visualization of the peripheral retina. A key aspect of this third and final aim is to make the imaging system compatible with standard clinical practices. To this end, we will incorporate sensorless adaptive optics in order to correct the inter- and intra- patient variability in ophthalmic aberrations. Sensorless adaptive optics will improve both the brightness (signal) and clarity (resolution) of features in the peripheral retina without affecting the size of the imaging system.

The proposed work should not only be a noteworthy contribution to the ophthalmic and engineering communities, but it should strengthen our existing collaborations with the Duke Eye Center by advancing their capability to diagnose pathologies of the peripheral retinal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Le stress oxydatif peut provenir de sources exogènes comme les UVA ou de sources endogènes comme la chaîne respiratoire (OXPHOS). L’oxydation des composants cellulaires a été associée avec la dégénération, des phénotypes de vieillissement et des pertes de fonctionnalités des tissus. Les UVA sont les plus efficaces des rayons UV à induire de l’oxydation, tel que démontré par la formation de dommages oxydatifs à l’ADN et par l’apparition de délétions mitochondriales qui en résultent. La délétion mitochondriale de 4977 pb (ADNmtCD4977), la plus commune, et celle de 3895 pb (ADNmt3895) sont deux délétions reliées au photovieillissement cutané et à l’exposition au stress oxydant. Le phénomène de vieillissement dans la peau est bien documenté et se traduit par une dégradation de la matrice extracellulaire, une perte d’élasticité et la formation de rides. Toutefois, peu d’études portent sur la cornée humaine alors qu’elle est un tissu exposé directement aux rayonnements UV au même titre que la peau. Nous avons donc tenté mieux comprendre l’effet de l’oxydation exogène et endogène sur cette structure. L’analyse de la localisation des délétions ADNmtCD4977 et ADNmtCD4977 dans l’oeil humain a permis de révéler qu’elles se concentrent principalement dans le stroma cornéen et s’accumule avec l’âge. Le stroma cornéen est la couche cellulaire qui confère la transparence et la rigidité à la cornée humaine. Ces résultats nous ont suggéré une implication des UVA dans le photovieillissement de la cornée. Nous avons donc entrepris de vérifier les changements liés à l’exposition aux UVA dans le stroma cornéen puisque les UVA sont connus pour causer des altérations à la matrice extracellulaire (ECM) au niveau cutané. Nous avons donc créé un modèle de photovieillisement par une exposition chronique aux UVA sur des kératocytes avec lesquels nous avons fait sécréter une ECM. Nos résultats nous ont démontré qu’une exposition chronique aux UVA cause des altérations à l’ECM cornéen semblable à des phénotypes de photvieillissement. En effet, nous avons dénoté des changements transcriptomiques et protéomiques pour certains collagènes et protéoglycans. Une atteinte aux collagènes par le vieillissement cornéen se traduit entre autres par une rigidification, une opacification et un changement dans son pouvoir réfractif qui mène à une perte de la vision. Par ailleurs, notre avons également investigué l’implication du stress oxydatif dans la dystrophie cornéenne endothéliale de Fuchs (FECD), une maladie dégénérative de l’endothélium cornéen, qui mène à une perte de vision et est une cause principale de greffe cornéenne. L’étiologie de la maladie est encore inconnue, mais le stress oxydatif est soupçonné de jouer un rôle important dans la pathogenèse. Nos résultats ont amené de nouvelles évidences de l’implication de l’oxydation dans la maladie par l’augmentation de la quantité d’ADN mitochondrial et un raccourcissement des télomères dans des explants de cornées pathologiques. Nos résultats nous ont également démontré que la mise en culture de cellules FECD permettait la sélection de cellules fonctionnelles et comparables à des cellules saines en termes de quantité d’ADN mitochondrial et de son intégrité, de sensibilité à l’oxydation et de longueur télomérique. Les résultats obtenus soutiennent ainsi la possibilité d’employer les cellules FECD fonctionnelles sélectionnées pour utilisation en génie tissulaire afin de créer des cornées autologues pour pallier aux manques de greffes cornéennes. Enfin, nos résultats apportent de nouvelles évidences quant à l’implication du stress oxydatif dans le photovieillissement cornéen et dans l’étiologie de la FECD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the progress of computer technology, computers are expected to be more intelligent in the interaction with humans, presenting information according to the user's psychological and physiological characteristics. However, computer users with visual problems may encounter difficulties on the perception of icons, menus, and other graphical information displayed on the screen, limiting the efficiency of their interaction with computers. In this dissertation, a personalized and dynamic image precompensation method was developed to improve the visual performance of the computer users with ocular aberrations. The precompensation was applied on the graphical targets before presenting them on the screen, aiming to counteract the visual blurring caused by the ocular aberration of the user's eye. A complete and systematic modeling approach to describe the retinal image formation of the computer user was presented, taking advantage of modeling tools, such as Zernike polynomials, wavefront aberration, Point Spread Function and Modulation Transfer Function. The ocular aberration of the computer user was originally measured by a wavefront aberrometer, as a reference for the precompensation model. The dynamic precompensation was generated based on the resized aberration, with the real-time pupil diameter monitored. The potential visual benefit of the dynamic precompensation method was explored through software simulation, with the aberration data from a real human subject. An "artificial eye'' experiment was conducted by simulating the human eye with a high-definition camera, providing objective evaluation to the image quality after precompensation. In addition, an empirical evaluation with 20 human participants was also designed and implemented, involving image recognition tests performed under a more realistic viewing environment of computer use. The statistical analysis results of the empirical experiment confirmed the effectiveness of the dynamic precompensation method, by showing significant improvement on the recognition accuracy. The merit and necessity of the dynamic precompensation were also substantiated by comparing it with the static precompensation. The visual benefit of the dynamic precompensation was further confirmed by the subjective assessments collected from the evaluation participants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abstract Purpose – To study the possibility of using a NIR hardware solution to photograph individuals in a private vehicle as well as an analysis of its images. Method – A study of existing theories around the NIR-method’s performance in selected conditions and individual tests were performed to examine if the literature statements were valid for this study. Two empirical tests have been carried out, the first was carried out at Kapsch test track and the other outside the test track in a single stationary test. An interview which formed the basis for the assessment on the quality of empirical data with a focus on computer-based detection of the number of individuals in the vehicle. Findings – The results have demonstrated the potential of the NIR method’s performance in a fully automated detection system for the number of individuals inside the vehicle. Empirical data indicates that the method can depict individuals inside vehicles of sufficiently high quality, but it is greatly affected by reflections, weather and light conditions. Implications – Result supports the assumption that the NIR method using an external light source can be used to image the interior through a varying number of weather and lightning conditions. The study originated until the results suggested that a NIR-based hardware setup can create images with high enough quality for the human eye to be able to detect the number of individuals inside the vehicle.If the overall performance into account, it suggests that the main problem with the use of the hardware set is to maintain the quality of the whole sample and that the crucial variables for the method’s performance is the influence of light and reflection conditions. Limitations – The major limitations have been that we limited ourselves to a subjective analysis of the selection and assessment on the image features for computer-based detection of the number of individuals in the vehicle. We were limited to two tests, one in tough conditions where only the driver was in the vehicle and the second stationary test, where the focus was on the number of people in vehicles and light sources impact on the result.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Our ability to regulate behavior based on past experience has thus far been examined using single movements. However, natural behavior typically involves a sequence of movements. Here, we examined the effect of previous trial type on the concurrent planning of sequential saccades using a unique paradigm. The task consisted of two trial types: no-shift trials, which implicitly encouraged the concurrent preparation of the second saccade in a subsequent trial; and target-shift trials, which implicitly discouraged the same in the next trial. Using the intersaccadic interval as an index of concurrent planning, we found evidence for context-based preparation of sequential saccades. We also used functional MRI-guided, single-pulse, transcranial magnetic stimulation on human subjects to test the role of the supplementary eye field (SEF) in the proactive control of sequential eye movements. Results showed that (i) stimulating the SEF in the previous trial disrupted the previous trial type-based preparation of the second saccade in the nonstimulated current trial, (ii) stimulating the SEF in the current trial rectified the disruptive effect caused by stimulation in the previous trial, and (iii) stimulating the SEF facilitated the preparation of second saccades based on previous trial type even when the previous trial was not stimulated. Taken together, we show how the human SEF is causally involved in proactive preparation of sequential saccades.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Il est mondialement reconnu que les institutions judiciaires jouent un rôle central dans le processus de prise de décisions politiques, à la fois au niveau national et international. C’est d’ailleurs le cas à la Haute Cour de justice d’Israël. L’étendue de son succès (ou de son échec) dans la tentative de trouver une solution aux violations des droits humains dans les territoires occupés est un problème qui continue de faire l’objet de bien des débats et de recherches académiques. À cet égard, il a été suggéré que, malgré l’absence de constitution écrite et l’existence d’un état d’urgence prolongé en Israël, la Haute Cour de justice a réussi à adopter une approche « judiciairement active » quant à la protection et la promotion des droits de l’homme de manière générale, y compris ceux des Palestiniens dans les territoires occupés. Dans cette perspective, le débat sur le processus d’examen judiciaire de la Haute Cour de Justice tient pour acquise la notion qu’Israël est une démocratie. Ainsi, cet article cherche à examiner cette hypothèse. Premièrement, en adoptant la position que le processus de révision judiciaire est compatible avec la démocratie et la règle de loi. Deuxièmement, il examine l’approche « judiciairement active » de la Cour et soumet un bref aperçu du processus, des outils et des principes légaux que la Cour adopte pour examiner les actions des autorités israéliennes, y compris l’armée, et imposer une loi commune de protection des droits de la personne, donc ceux des Palestiniens dans les territoires occupés. L’article argumente également que le contrôle prolongé des territoires occupés par Israël a eu des conséquences significatives, car tout effort fourni par la Cour pour garantir le respect des droits humains de la population civile palestinienne doit se faire sans compromettre la sécurité du pouvoir israélien. La conclusion à laquelle on arrive ici dépend de la façon dont on qualifie ce contrôle: une occupation à long terme ou une annexion (ce qui n’est pas réglementaire par rapport à loi internationale), ce qui n’est pas sans conséquence sur le rôle que la Haute Cour de justice peut effectivement jouer pour faire respecter les droits de la personne dans les territoires occupés.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the main challenges for developers of new human-computer interfaces is to provide a more natural way of interacting with computer systems, avoiding excessive use of hand and finger movements. In this way, also a valuable alternative communication pathway is provided to people suffering from motor disabilities. This paper describes the construction of a low cost eye tracker using a fixed head setup. Therefore a webcam, laptop and an infrared lighting source were used together with a simple frame to fix the head of the user. Furthermore, detailed information on the various image processing techniques used for filtering the centre of the pupil and different methods to calculate the point of gaze are discussed. An overall accuracy of 1.5 degrees was obtained while keeping the hardware cost of the device below 100 euros.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The amygdala was more responsive to fearful (larger) eye whites than to happy (smaller) eye whites presented in a masking paradigm that mitigated subjects' awareness of their presence and aberrant nature. These data demonstrate that the amygdala is responsive to elements of.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Automatically extracting interesting objects from videos is a very challenging task and is applicable to many research areas such robotics, medical imaging, content based indexing and visual surveillance. Automated visual surveillance is a major research area in computational vision and a commonly applied technique in an attempt to extract objects of interest is that of motion segmentation. Motion segmentation relies on the temporal changes that occur in video sequences to detect objects, but as a technique it presents many challenges that researchers have yet to surmount. Changes in real-time video sequences not only include interesting objects, environmental conditions such as wind, cloud cover, rain and snow may be present, in addition to rapid lighting changes, poor footage quality, moving shadows and reflections. The list provides only a sample of the challenges present. This thesis explores the use of motion segmentation as part of a computational vision system and provides solutions for a practical, generic approach with robust performance, using current neuro-biological, physiological and psychological research in primate vision as inspiration.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the possible models of the human visual system (HVS) in the computer vision literature has a high resolution fovea and exponentially decreasing resolution periphery. The high resolution fovea is used to extract necessary information in order to solve a vision task and the periphery may be used to detect motion. To obtain the desired information, the fovea is guided by the contents of the scene and other knowledge to position the fovea over areas of interest. These eye movements are called saccades and corrective saccades. A two stage process has been implemented as a mechanism for changing foveation in log polar space. Initially, the open loop stage roughly foveates on the best interest feature and then the closed loop stage is invoked to accurately iteratively converge onto the foveation point. The open loop stage developed for the foveation algorithm is applied to saccadic eye movements and a tracking system. Log polar space is preferred over Cartesian space as: (1) it simultaneously provides high resolution and a wide viewing angle; and (2) feature invariance occurs in the fovea which simplifies the foveation process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aniridia (AN) is a congenital, panocular disorder of the eye characterized by the complete or partial absence of the iris. The disease can occur in both the sporadic and familial forms which, in the latter case, is inherited as an autosomal dominant trait with high penetrance. The objective of this study was to isolate and characterize the genes involved in AN and Sey, and thereby to gain a better understanding of the molecular basis of the two disorders.^ Using a positional cloning strategy, I have approached and cloned from the AN locus in human chromosomal band 11p13 a cDNA that is deleted in two patients with AN. The deletions in these patients overlap by about 70 kb and encompass the 3$\sp\prime$ end of the cDNA. This cDNA detects a 2.7 kb mRNA encoded by a transcription unit estimated to span approximately 50 kb of genomic DNA. The message is specifically expressed in all tissues affected in all forms of AN, namely within the presumptive iris, lens, neuroretina, the superficial layers of the cornea, the olfactory bulbs, and the cerebellum. Sequence analysis of the AN cDNA revealed a number of motifs characteristic of certain transcription factors. Chief among these are the presence of the paired domain, the homeodomain, and a carboxy-terminal domain rich in serine, threonine and proline residues. The overall structure shows high homology to the Drosophila segmentation gene paired and members of the murine Pax family of developmental control genes.^ Utilizing a conserved human genomic DNA sequence as probe, I was able to isolate an embryonic murine cDNA which is over 92% homologous in nucleotide sequence and virtually identical at the amino acid level to the human AN cDNA. The expression pattern of the murine gene is the same as that in man, supporting the conclusion that it probably corresponds to the Sey gene. Its specific expression in the neuroectodermal component of the eye, in glioblastomas, but not in the neural crest-derived PC12 pheochromocytoma cell line, suggests that a defect in neuroectodermal rather mesodermal development might be the common etiological factor underlying AN and Sey. ^