987 resultados para Hplc Method
Resumo:
A reversed-phase HPLC method was developed and validated to separate and simultaneously quantify the association of betamethasone sodium phosphate (BP) and betamethasone dipropionate (BD) in injectable suspensions. Chromatographic conditions were ternary gradient elution at 1.6 mL/min on a C18 column with 254 nm. The linearity of the method was established in the range 120 to 280 mg/mL BD, and 48 to 112 mg/mL BP. The RSD of intermediate precision of the method was <1% and recoveries were 99-101% for both drugs. The method proved selective, linear, precise, accurate and robust for quantifying BP and BD in commercial injectable suspensions.
Resumo:
A simple and sensitive method has been proposed for the determination of sibutramine-HCl in energy drinks, green tea and pharmaceutical formulations using differential pulse voltammetry performed on a hanging mercury drop electrode. In the chosen experimental condition (Mcllvaine pH 4.0 buffer, 50 mV pulse amplitude and 40 mV s-1 scan velocity), sibutramine-HCl presented a reversible behavior and a peak maximum at -80 mV. Detection limit was 0.4 mg L-1 and the working linear range extended up to 33.3 mg L-1 (r = 0.99). Analysis of real and fortified samples enabled recoveries between 91 and 102%. The electroanalytical method was compared with a HPLC method which indicated it accuracy.
Resumo:
In this work, theospheres (innovative lipid nanoparticles) were prepared by the high pressure homogenization technique using different surfactants for dapsone encapsulation. Mean particle size ranged from 105 to 153 nm and negative zeta potentials were obtained for all theosphere formulations. Atomic force microscopy images confirmed the spherical shape of theospheres. The HPLC method used to determine dapsone-loaded theospheres was selective, linear, exact and precise. The entrapment efficiency of dapsone was 91.4%. Theospheres provided controlled release of idebenone (52.7 ± 1.6%) in comparison to the free drug (103.1 ± 1.9%).
Resumo:
An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).
Resumo:
This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.
Resumo:
The application of automated correlation optimized warping (ACOW) to the correction of retention time shift in the chromatographic fingerprints of Radix Puerariae thomsonii (RPT) was investigated. Twenty-seven samples were extracted from 9 batches of RPT products. The fingerprints of the 27 samples were established by the HPLC method. Because there is a retention time shift in the established fingerprints, the quality of these samples cannot be correctly evaluated by using similarity estimation and principal component analysis (PCA). Thus, the ACOW method was used to align these fingerprints. In the ACOW procedure, the warping parameters, which have a significant influence on the alignment result, were optimized by an automated algorithm. After correcting the retention time shift, the quality of these RPT samples was correctly evaluated by similarity estimation and PCA. It is demonstrated that ACOW is a practical method for aligning the chromatographic fingerprints of RPT. The combination of ACOW, similarity estimation, and PCA is shown to be a promising method for evaluating the quality of Traditional Chinese Medicine.
Resumo:
Changes in urinary porphyrin excretion may be the result of hereditary causes and/or from environmental or occupational exposure. The objective of this study was to measure the amount of some porphyrins in spot urine samples obtained from volunteers randomly selected from a healthy adult population of São Paulo with a sensitive HPLC method and to estimate normal ranges for a non-exposed population. Spot urine samples were collected from 126 subjects (both genders, 18 to 65 years old) not occupationally exposed to porphyrinogenic agents. Porphyrin fractions were separated on RP-18 HPLC column eluted with a methanol/ammonium acetate buffer gradient, pH 4.0, and measured fluorometrically (excitation 405 nm/emission 620 nm). The amount of porphyrins was corrected for urinary creatinine excretion. Only 8-carboxyl (uro) and 4-carboxyl (copro) porphyrins were quantified as µg/g creatinine. Data regarding age, gender, occupational activities, smoking and drinking habits were analyzed by Mann-Whitney and Kruskal-Wallis tests. Uroporphyrin results did not differ significantly between the subgroups studied. Copro and uro + copro porphyrins were significantly different for smokers (P = 0.008) and occupational activities (P = 0.004). With respect to alcohol consumption, only men drinking >20 g/week showed significant differences in the levels of copro (P = 0.022) and uro + copro porphyrins (P = 0.012). The 2.5-97.5th percentile limit values, excluding those for subjects with an alcohol drinking habit >20 g/week, were 0-20.8, 11.7-93.1, and 15.9-102.9 µg/g creatinine for uro, copro and uro + copro porphyrins, respectively. These percentile limit values can be proposed as a first attempt to provide urinary porphyrin reference values for our population, serving for an early diagnosis of porphyrinopathies or as biomarkers of exposure to porphyrinogenic agents.
Resumo:
The 10-HDA content in Brazilian samples (São Paulo State) of royal jelly (RJ) was analyzed using an HPLC method based on the work by BLOODWORTH et al. [2]. The chromatographic conditions were: isocratic system, reversed phase C18-H column, auto sampler, diode array UV-VIS detector adjusted to 225nm, mobile phase composed by methanol/water (45:55) at pH= 2.5 adjusted with phosphoric acid; a-naphtol was used as internal standard, and the running time was 30min. By statistical analysis of the results, the 10-HDA contents of the samples analyzed seem to have two ranges: 1.8% and 3% (w/w), that would be useful to qualify the RJ. This is the first data regarding 10-HDA content of Brazilian RJ.
Resumo:
Decaffeinated coffee accounts for 10 percent of coffee sales in the world; it is preferred by consumers that do not wish or are sensitive to caffeine effects. This article presents an analytical comparison of capillary electrophoresis (CE) and high performance liquid chromatography (HPLC) methods for residual caffeine quantification in decaffeinated coffee in terms of validation parameters, costs, analysis time, composition and treatment of the residues generated, and caffeine quantification in 20 commercial samples. Both methods showed suitable validation parameters. Caffeine content did not differ statistically in the two different methods of analysis. The main advantage of the high performance liquid chromatography (HPLC) method was the 42-fold lower detection limit. Nevertheless, the capillary electrophoresis (CE) detection limit was 115-fold lower than the allowable limit by the Brazilian law. The capillary electrophoresis (CE) analyses were 30% faster, the reagent costs were 76.5-fold, and the volume of the residues generated was 33-fold lower. Therefore, the capillary electrophoresis (CE) method proved to be a valuable analytical tool for this type of analysis.
Resumo:
The goal of this thesis was to study factors related to the development of Brassica juncea as a sustainable nematicide. Brassica juncea is characterized by the glycoside (glucosinolate) sinigrin. Various methods were developed for the determination of sinigrin in Brassica juncea tissue extracts. Sinigrin concentrations in plant tissues at various stages of growth were monitored. Sinigrin enzymatically breaks down into allylisothiocyanate (AITC). AITC is unstable in aqueous solution and degradation was studied in water and in soil. Finally, the toxicity of AITC against the root-lesion nematode (Pratylenchus penetrans) was determined. A method was developed to extract sinigrin from whole Brassica j uncea tissues. The optimal time of extraction wi th boiling phosphate buffer (0.7mM, pH=6.38) and methanol/water (70:30 v/v) solutions were both 25 minutes. Methanol/water extracted 13% greater amount of sinigrin than phosphate buffer solution. Degradation of sinigrin in boiling phosphate buffer solution (0.13%/minute) was similar to the loss of sinigrin during the extraction procedure. The loss of sinigrin from boiling methanol/water was estimated to be O.Ol%/minute. Brassica juncea extract clean up was accomplished by an ion-pair solid phase extraction (SPE) method. The recovery of sinigrin was 92.6% and coextractive impurities were not detected in the cleaned up extract. Several high performance liquid chromatography (HPLC) methods were developed for the determination of sinigrin. All the developed methods employed an isocratic mobile phase system wi th a low concentration of phosphate buffer solution, ammonium acetate solution or an ion-pair reagent solution. A step gradient system was also developed. The method involved preconditioning the analytical column with phosphate buffer solution and then switching the mobile phase to 100% water after sample injection.Sinigrin and benzyl-glucosinolate were both studied by HPLC particle beam negative chemical ionization mass spectrometry (HPLCPB- NCI-MS). Comparison of the mass spectra revealed the presence of fragments arising from the ~hioglucose moiety and glucosinolate side-chain. Variation in the slnlgrin concentration within Brassica juncea plants was studied (Domo and Cutlass cuItivars). The sinigrin concentration in the top three leaves was studied during growth of each cultivar. For Cutlass, the minimum (200~100~g/g) and maximum (1300~200~g/g) concentrations were observed at the third and seventh week after planting, respectively. For Domo, the minimum (190~70~g/g) and maximum (1100~400~g/g) concentrations were observed at the fourth and eighth week after planting, respectively. The highest sinigrin concentration was observed in flower tissues 2050±90~g/g and 2300±100~g/g for Cutlass and Domo cultivars, respectively. Physical properties of AITC were studied. The solubility of AITC in water was determined to be approximately 1290~g/ml at 24°C. An HPLC method was developed for the separation of degradation compounds from aqueous AITC sample solutions. Some of the degradation compounds identified have not been reported in the literature: allyl-thiourea, allyl-thiocyanate and diallyl-sulfide. In water, AITC degradation to' diallyl-thiourea was favored at basic pH (9.07) and degradation to diallyl-sulfide was favored at acidic pH (4 . 97). It wap necessary to amend the aqueous AITC sample solution with acetonitrile ?efore injection into the HPLC system. The acetonitrile amendment considerably improved AITC recovery and the reproducibility of the results. The half-life of aqueous AITC degradation at room temperature did not follow first-order kinetics. Beginning with a 1084~g/ml solution, the half-life was 633 hours. Wi th an ini tial AITC concentration of 335~g/ml the half-life was 865 hours. At 35°C the half-life AITC was 76+4 hours essentially independent of the iiisolution pH over the range of pH=4.97 to 9.07 (1000~g/ml). AITC degradation was also studied in soil at 35°C; after 24 hours approximately 75% of the initial AITC addition was unrecoverable by water extraction. The ECso of aqueous AITC against the root-lesion nematode (Pratylenchus penetrans) was determined to be approximately 20~g/ml at one hour exposure of the nematode to the test solution. The toxicological study was also performed with a myrosinase treated Brassica juncea extract. Myrosinase treatment of the Brassica juncea extract gave nearly quantitative conversion of sinigrin into AITC. The myrosinase treated extract was of the same efficacy as an aqueous AITC solution of equivalent concentration. The work of this thesis was focused upon understanding parameters relevant to the development of Brassica juncea as a sustainable nematicide. The broad range of experiments were undertaken in support of a research priority at Agriculture and Agri-Food Canada.
Resumo:
Introduction : Les modèles murins sont grandement utilisés dans l’étude des maladies rénales et des pathologies associées. La concentration de la créatinine sérique est un bon indicateur de la filtration glomérulaire et en présence d’insuffisance rénale chronique (IRC), les concentrations de créatinine sérique (et la clairance) reflètent la sévérité de l’IRC. De plus, il a été démontré que l’IRC modifie le métabolisme des médicaments en diminuant l’activité et l’expression des enzymes hépatiques du cytochrome P450 (CYP450). Afin d’étudier la modulation du P450 par l’IRC avec un modèle murin et de confirmer nos résultats chez le rat, nous devons 1) développer un modèle d’IRC chez la souris, 2) mettre au point une technique de dosage des marqueurs de l’IRC et, 3) évaluer l’expression protéique du CYP450 en présence IRC. Matériel et Méthode : Trois modèles chirurgicaux d’IRC chez la souris ont été développés. Une méthode du dosage de la créatinine par chromatographie liquide à haute performance (CLHP) a été mise au point chez la souris et l’expression protéique du P450 a été mesurée par immunobuvardage de type Western. Résultats : Plusieurs paramètres de CLHP comme le pH, la concentration et le débit de la phase mobile modifient le pic d’élution et le temps de rétention de la créatinine. Concernant le modèle expérimental, on observe une perte de poids et une augmentation de la concentration plasmatique de la créatinine chez les souris avec une IRC. De plus, l’expression protéique de plusieurs isoformes du cytochrome P450 est modulée par l’IRC. Nous observons une diminution du CYP 2D de 42% (p < 0,01), du CYP 3A11 de 60% et du CYP 1A de 37% (p <0,01) par rapport aux souris témoins. On ne dénote aucun changement significatif au niveau de l’isoforme 2E1. Conclusion : Il est possible d’induire une insuffisance rénale chronique chez la souris suite à une néphrectomie. La technique de dosage de la créatinine par CLHP est précise et exacte et permet de caractériser la sévérité de l’IRC chez la souris. L’expression protéique du CYP450 est régulée à la baisse dans le foie des souris atteintes d’IRC.
Resumo:
Dans cette étude, la stabilité de préparations intraveineuses de cyclosporine (0.2 et 2.5 mg/mL dans NaCl 0.9% ou dextrose 5%) entreposées dans des seringues de polypropylène, des sacs de polypropylène-polyoléfine et des sacs de vinyle acétate d’éthylène a été évaluée. Une méthode HPLC indicatrice de la stabilité à base de méthanol a été développée et validée suite a des études de dégradation forcée. Les solutions évaluées ont été préparées de façon aseptique, puis entreposées à 25°C. La stabilité chimique a été évaluée par HPLC et la stabilité physique a été évaluée par inspection visuelle et aussi par diffusion dynamique de la lumière (DLS). Tous les échantillons sont demeurés stables chimiquement et physiquement dans des sacs de polypropylène-polyoléfine (>98% de cyclosporine récupérée après 14 jours). Lorsqu’entreposés dans des seringues de polypropylène, des contaminants ont été extraits des composantes de la seringue. Toutefois, aucune contamination n’a été observée après 10 min de contact entre la préparation de cyclosporine non-diluée et ces mêmes seringues. Les préparations de 2.5 mg/mL entreposées dans des sacs de vinyle acétate d’éthylène sont demeurés stables chimiquement et physiquement (>98% de cyclosporine récupérée après 14 jours). Toutefois, une adsorption significative a été observée avec les échantillons 0.2 mg/mL entreposés dans des sacs de vinyle acétate d’éthylène (<90% de cyclosporine récupéré après 14 jours). Une étude cinétique a démontré une bonne corrélation linéaire entre la quantité adsorbée et la racine carrée du temps de contact (r2 > 0.97). Un nouveou modèle de diffusion a été établi. En conclusion, les sacs de polypropylène-polyoléfine sont le meilleur choix; les seringues de polypropylène présentent un risque de contamination, mais sont acceptables pour un transfert rapide. Les sacs de vinyle acétate d’éthylène ne peuvent être recommandés à cause d’un problème d’adsorption.
Resumo:
Introducción: La melatonina, una sustancia cronobiótica endógena, es cada vez más empleada para el manejo de los problemas del sueño en adultos mayores por su aparente eficacia y buen perfil de eventos adversos. En este sentido, se intentó evaluar la eficacia de la melatonina en el tratamiento del insomnio primario en el adulto mayor (≥55 años) comparado con benzodiacepinas, zopiclona y placebo a la luz de la evidencia disponible en los últimos cinco años. Métodos: Revisión sistemática de la literatura. Resultados: En comparación con placebo, al parecer la melatonina mejora la calidad y los hábitos de sueño, no así la latencia de inicio de sueño en mediciones subjetivas ni objetivas (polisomnografía); a diferencia de otros medicamentos hipnóticos, no altera la arquitectura del sueño ni genera síntomas diurnos. Conclusiones: No se encontró evidencia que soporte el uso de melatonina en adultos mayores de 55 años para la reducción de la latencia de sueño, aumento del tiempo total de sueño, mejoría de la eficiencia del sueño, disminución de despertares nocturnos o mejoría de la calidad de sueño. Es necesario adelantar más estudios en comparación con placebo y otros medicamentos.
Resumo:
This contribution describes the optimization of chlorine extraction from silicate samples by pyrohydrolysis prior to the precise determination of Cl stable-isotope compositions (637 Cl) by gas source, dual inlet Isotope Ratio Mass Spectrometry (IRMS) on CH(3)Clg. The complete method was checked on three international reference materials for Cl-content and two laboratory glass standards. Whole procedure blanks are lower than 0. 5 mu mol, corresponding to less than 10 wt.% of most of the sample chloride analysed. In the absence of international chlorine isotope rock, we report here Cl extracted compared to accepted Cl contents and reproducibilities on Cl and delta Cl-37 measurements for the standard rocks. After extraction, the Cl contents of the three international references compared within error with the accepted values (mean yield = 94 +/-10%) with reproducibilities better than 12% (10). The laboratory glass standards - andesite SO100DS92 and phonolite S9(2) - were used specifically to test the effect of chloride amount on the measurements. They gave Cl extraction yields of 100 +/-6% (1 sigma-; n = 15) and 105 +/- 8% (1 sigma-; n = 7), respectively, with delta Cl-37 values of -0.51 0.14%o and -0.39 0.17%o (1g). In summary, for silicate samples with Cl contents between 39 and 9042 ppm, the Pyrohydrolysis/HPLC method leads to overall CI extraction yields of 100 8%, reproducibilities on Cl contents of 7% and on delta Cl-37 measurements of 0.12%o (all 1 sigma). The method was further applied to ten silicate rocks of various mineralogy and chemistry (meteorite, fresh MORB glasses, altered basalts and setpentinized peridotites) chosen for their large range of Cl contents (70-2156 ppm) and their geological significance. delta Cl-37 values range between -2.33 and -0.50%o. These strictly negative values contrast with the large range and mainly positive values previously reported for comparable silicate samples and shown here to be affected by analytical problems. Thus we propose a preliminary, revised terrestrial CI cycle, mainly dominated by negative and zero delta Cl-37 values. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Background and Objective: Dispensing medicines into compliance aids is a common practice in pharmacy contrary to manufacturers’ advice and studies have shown the appearance of light-sensitive tablets is compromised by such storage; we previously found evidence of reduced bioavailability at elevated temperature and humidity. Our objective was to examine the physicochemical stability of two generic atenolol tablets in different compliance aids and with aspirin co-storage at room temperature and at 40 °C/75% relative humidity. Methods: The physicochemical stability of atenolol tablets was evaluated after 28 days of storage and compared with controls by examining visual appearance, weight, disintegration, dissolution, friability and hardness to accepted standards and using a previously validated HPLC method for chemical assay. Results and Discussion: The response to storage was brand-dependent and not straightforward. With one make of atenolol (Alpharma), storage in compliance aids even at room temperature impacted on physical stability, reducing tablet hardness, with storage in Dosett® exerting a greater impact than storage in Medidos® (t-test P < 0·001). Co-storage at elevated temperature and humidity also impacted on the appearance of non-coated aspirin tablets (Angette™). The chemical stability of atenolol was not affected and we did not find evidence of changes to bioavailability with either make. Certainly data for one atenolol make (CP Pharmaceuticals) co-stored with aspirin (Angette™ and Nu-Seals) in both compliance aids at room temperature provided evidence of short-term stability. But medicines are dispensed into compliance aids in multi-factorial ways so our study highlights not only the lack of evidence but also a realization that evidence to support real practice may not be accomplished through research. Conclusion: Reassuring practitioners of the continued stability of medicines in compliance aids under the countless condition in which they are dispensed in practice may requires a different approach involving medical device regulators and more definitive professional guidance.