897 resultados para Home monitoring system


Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this abstract is presented an energy management system included in a SCADA system existent in a intelligent home. The system control the home energy resources according to the players definitions (electricity consumption and comfort levels), the electricity prices variation in real time mode and the DR events proposed by the aggregators.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present paper results of an ongoing research project were it is expected to develop an information system to monitoring a cultural-touristic route. The route to monitor is the Romanesque Route of Tâmega. This Route is composed of 58 monuments located in the region of Tâmega in the North of Portugal. Due to the particular location of this region, that is between coastal zone, but not yet in the inland, it has a weak political influence, and it is reflected in the low levels of development at several levels, observed. The Romanesque Route was implemented in a part of this region in 1998, and enlarged to the all-region in 2010. In order to evaluate the socio-ecomonic impact of this route in the region a research project is being developed. The main goal of this paper is to open a discussion on the elements that must be taken into consideration to evaluate the economic and social impact of a touristic cultural route within a region and this one in particular.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Monitoring is a very important aspect to consider when developing real-time systems. However, it is also important to consider the impact of the monitoring mechanisms in the actual application. The use of Reflection can provide a clear separation between the real-time application and the implemented monitoring mechanisms, which can be introduced (reflected) into the underlying system without changing the actual application part of the code. Nevertheless, controlling the monitoring system itself is still a topic of research. The monitoring mechanisms must contain knowledge about “how to get the information out”. Therefore, this paper presents the ongoing work to define a suitable strategy for monitoring real-time systems through the use of Reflection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Operational Modal Analysis is currently applied in structural dynamic monitoring studies using conventional wired based sensors and data acquisition platforms. This approach, however, becomes inadequate in cases where the tests are performed in ancient structures with esthetic concerns or in others, where the use of wires greatly impacts the monitoring system cost and creates difficulties in the maintenance and deployment of data acquisition platforms. In these cases, the use of sensor platforms based on wireless and MEMS would clearly benefit these applications. This work presents a first attempt to apply this wireless technology to the structural monitoring of historical masonry constructions in the context of operational modal analysis. Commercial WSN platforms were used to study one laboratory specimen and one of the structural elements of a XV century building in Portugal. Results showed that in comparison to the conventional wired sensors, wireless platforms have poor performance in respect to the acceleration time series recorded and the detection of modal shapes. However, for frequency detection issues, reliable results were obtained, especially when random excitation was used as noise source.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O presente projeto enquadra-se na área das redes de sensores sem fios, onde o seu crescente desenvolvimento permite aplicar esta tecnologia em diversas áreas, como por exemplo, na monitorização ambiental, utilização militar, domótica, saúde, entre outras. Uma rede de sensores sem fios consiste em diversos nós dispersos num campo de aplicação onde procedem à recolha de dados do ambiente em que estão inseridos, como o valor de uma temperatura, humidade ou outra grandeza física, e os transmitem para uma estação base onde podem ser monitorizados. Tendo a área da saúde uma importância significativa, este projeto focalizou-se na mesma. O projeto apresentado nesta dissertação teve como principal objetivo o desenvolvimento de uma rede de sensores sem fios, em que dois nós procedam à aquisição da temperatura corporal de uma pessoa em dois locais distintos, para posterior envio da mesma para os restantes nós da rede, onde será apresentada em estações de monitorização. Este projeto foi desenvolvido baseado num recente protocolo de redes sem fios, nomeadamente o protocolo ANTTM. Assim sendo, em primeiro lugar, serão abordados neste relatório os objetivos e a contextualização deste projeto. Em seguida, será apresentada uma comparação sobre alguns aspetos de algumas tecnologias de comunicações sem fios, nomeadamente o ZigBee, Bluetooth e ANT. Devido ao fato da tecnologia ANT ser a escolhida para o desenvolvimento deste projeto, será também apresentado um estudo mais detalhado sobre o mesmo. Depois, será apresentado o desenvolvimento e implementações efetuadas, e por último serão apresentadas as conclusões técnicas e pessoais que este projeto permitiu obter.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP 2015). 7 to 9, Apr, 2015. Singapure, Singapore.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

90.00% 90.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aquest treball s’enfoca cap l’anàlisi de les emissions de gasos amb un potencial impacte negatiu sobre l’entorn que es poden emetre a l’atmosfera durant el compostatge casolà com són el metà i l’òxid nitrós pel seu paper de gasos d’efecte hivernacle i l’amoníac, però sense oblidar el seguiment dels paràmetres del procés en si i la determinació de la qualitat del compost produït. Durant poc més de 6 mesos s’ha simulat un sistema de compostatge casolà tal i com podria donar‐se en un domicili particular i s’ha confirmat la seva eficàcia en la reducció en pes del residu tractat així com l’obtenció d’un producte final altament estable i d’una qualitat més que acceptable. Pel que fa a les emissions de gasos, les quantitats determinades no són menyspreables. L’experiment s’ha realitzat per triplicat. Les emissions són molt erràtiques i no s’han trobat patrons clars en la seva evolució durant el procés de compostatge més enllà d’una certa correlació entre les emissions d’amoníac i la diferència de temperatures entre l’ambient i l’interior dels compostadors. Cal destacat un elevat grau de biaix en la determinació d’emissions gasoses a petita escala, com és el cas del compostatge casolà. Finalment constatar que la generació de lixiviats en el compostatge domèstic pot ser important donat el contingut en aigua de la matèria orgànica tractada a nivell casolà i el limitat accés a material estructurant sec que es té per a compensar‐les.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Poor medication adherence is a frequent cause of treatment failure but is difficult to diagnose. In this study we have evaluated the impact of measuring adherence to cinacalcet-HCl and phosphate binders in dialysis patients with uncontrolled secondary hyperparathyroidism. METHODS: 7 chronic dialysis patients with iPTH-levels >= 300 pg/ml despite treatment with >= 60 mg cinacalcet-HCl were included. Medication adherence was measured using the "Medication Events Monitoring System" during 3 months, followed by another 3-month period without monitoring. The adherence results were monthly discussed with the patients, as well as strategies to improve them. RESULTS: During monitoring, the percentage of prescribed doses taken was higher for cinacalcet-HCl (87.4%) and sevelamer (86.3%) than for calcium acetate (76.1%), as was the taking adherence (81.9% vs. 57.3% vs. 49.1%) but not the percentage of drug holidays (12.3% vs. 4.5% vs. 3.6%). Mean PO4 levels (from 2.24 +/- 0.6 mmol/l to 1.73 +/- 0.41 mmol/l; p = 0.14) and Ca++ x PO4 product (4.73 +/- 1.43 to 3.41 +/- 1.04 mmol2/l2; p = 0.12) improved and iPTH-level improved significantly from 916 +/- 618 pg/ml to 442 +/- 326 pg/ml (p = 0.04), without any change in medication. However, as drug monitoring was interrupted, all laboratory parameters worsened again. CONCLUSIONS: Assessment of drug adherence helped to document episodes of non-compliance and helped to avoid seemingly necessary dose increases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work proposes an original contribution to the understanding of shermen spatial behavior, based on the behavioral ecology and movement ecology paradigms. Through the analysis of Vessel Monitoring System (VMS) data, we characterized the spatial behavior of Peruvian anchovy shermen at di erent scales: (1) the behavioral modes within shing trips (i.e., searching, shing and cruising); (2) the behavioral patterns among shing trips; (3) the behavioral patterns by shing season conditioned by ecosystem scenarios; and (4) the computation of maps of anchovy presence proxy from the spatial patterns of behavioral mode positions. At the rst scale considered, we compared several Markovian (hidden Markov and semi-Markov models) and discriminative models (random forests, support vector machines and arti cial neural networks) for inferring the behavioral modes associated with VMS tracks. The models were trained under a supervised setting and validated using tracks for which behavioral modes were known (from on-board observers records). Hidden semi-Markov models performed better, and were retained for inferring the behavioral modes on the entire VMS dataset. At the second scale considered, each shing trip was characterized by several features, including the time spent within each behavioral mode. Using a clustering analysis, shing trip patterns were classi ed into groups associated to management zones, eet segments and skippers' personalities. At the third scale considered, we analyzed how ecological conditions shaped shermen behavior. By means of co-inertia analyses, we found signi cant associations between shermen, anchovy and environmental spatial dynamics, and shermen behavioral responses were characterized according to contrasted environmental scenarios. At the fourth scale considered, we investigated whether the spatial behavior of shermen re ected to some extent the spatial distribution of anchovy. Finally, this work provides a wider view of shermen behavior: shermen are not only economic agents, but they are also foragers, constrained by ecosystem variability. To conclude, we discuss how these ndings may be of importance for sheries management, collective behavior analyses and end-to-end models.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: As part of EUROCAT's surveillance of congenital anomalies in Europe, a statistical monitoring system has been developed to detect recent clusters or long-term (10 year) time trends. The purpose of this article is to describe the system for the identification and investigation of 10-year time trends, conceived as a "screening" tool ultimately leading to the identification of trends which may be due to changing teratogenic factors.METHODS: The EUROCAT database consists of all cases of congenital anomalies including livebirths, fetal deaths from 20 weeks gestational age, and terminations of pregnancy for fetal anomaly. Monitoring of 10-year trends is performed for each registry for each of 96 non-independent EUROCAT congenital anomaly subgroups, while Pan-Europe analysis combines data from all registries. The monitoring results are reviewed, prioritized according to a prioritization strategy, and communicated to registries for investigation. Twenty-one registries covering over 4 million births, from 1999 to 2008, were included in monitoring in 2010.CONCLUSIONS: Significant increasing trends were detected for abdominal wall anomalies, gastroschisis, hypospadias, Trisomy 18 and renal dysplasia in the Pan-Europe analysis while 68 increasing trends were identified in individual registries. A decreasing trend was detected in over one-third of anomaly subgroups in the Pan-Europe analysis, and 16.9% of individual registry tests. Registry preliminary investigations indicated that many trends are due to changes in data quality, ascertainment, screening, or diagnostic methods. Some trends are inevitably chance phenomena related to multiple testing, while others seem to represent real and continuing change needing further investigation and response by regional/national public health authorities.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This Phase II project follows a previous project titled Strategies to Address Nighttime Crashes at Rural, Unsignalized Intersections. Based on the results of the previous study, the Iowa Highway Research Board (IHRB) indicated interest in pursuing further research to address the quality of lighting, rather than just the presence of light, with respect to safety. The research team supplemented the literature review from the previous study, specifically addressing lighting level in terms of measurement, the relationship between light levels and safety, and lamp durability and efficiency. The Center for Transportation Research and Education (CTRE) teamed with a national research leader in roadway lighting, Virginia Tech Transportation Institute (VTTI) to collect the data. An integral instrument to the data collection efforts was the creation of the Roadway Monitoring System (RMS). The RMS allowed the research team to collect lighting data and approach information for each rural intersection identified in the previous phase. After data cleanup, the final data set contained illuminance data for 101 lighted intersections (of 137 lighted intersections in the first study). Data analysis included a robust statistical analysis based on Bayesian techniques. Average illuminance, average glare, and average uniformity ratio values were used to classify quality of lighting at the intersections.