970 resultados para Heart valve


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To propose standardized consensus definitions for important clinical endpoints in transcatheter aortic valve implantation (TAVI), investigations in an effort to improve the quality of clinical research and to enable meaningful comparisons between clinical trials. To make these consensus definitions accessible to all stakeholders in TAVI clinical research through a peer reviewed publication, on behalf of the public health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims This study aimed to assess functional course in elderly patients undergoing transcatheter aortic valve implantation (TAVI) and to find predictors of functional decline. Methods and results In this prospective cohort, functional course was assessed in patients ≥70 years using basic activities of daily living (BADL) before and 6 months after TAVI. Baseline EuroSCORE, STS score, and a frailty index (based on assessment of cognition, mobility, nutrition, instrumental and basic activities of daily living) were evaluated to predict functional decline (deterioration in BADL) using logistic regression models. Functional decline was observed in 22 (20.8%) of 106 surviving patients. EuroSCORE (OR per 10% increase 1.18, 95% CI: 0.83-1.68, P = 0.35) and STS score (OR per 5% increase 1.64, 95% CI: 0.87-3.09, P = 0.13) weakly predicted functional decline. In contrast, the frailty index strongly predicted functional decline in univariable (OR per 1 point increase 1.57, 95% CI: 1.20-2.05, P = 0.001) and bivariable analyses (OR: 1.56, 95% CI: 1.20-2.04, P = 0.001 controlled for EuroSCORE; OR: 1.53, 95% CI: 1.17-2.02, P = 0.002 controlled for STS score). Overall predictive performance was best for the frailty index [Nagelkerke's R(2) (NR(2)) 0.135] and low for the EuroSCORE (NR(2) 0.015) and STS score (NR(2) 0.034). In univariable analyses, all components of the frailty index contributed to the prediction of functional decline. Conclusion Over a 6-month period, functional status worsened only in a minority of patients surviving TAVI. The frailty index, but not established risk scores, was predictive of functional decline. Refinement of this index might help to identify patients who potentially benefit from additional geriatric interventions after TAVI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims Cardiac grafts from non-heartbeating donors (NHBDs) could significantly increase organ availability and reduce waiting-list mortality. Reluctance to exploit hearts from NHBDs arises from obligatory delays in procurement leading to periods of warm ischemia and possible subsequent contractile dysfunction. Means for early prediction of graft suitability prior to transplantation are thus required for development of heart transplantation programs with NHBDs. Methods and Results Hearts (n = 31) isolated from male Wistar rats were perfused with modified Krebs-Henseleit buffer aerobically for 20 min, followed by global, no-flow ischemia (32°C) for 30, 50, 55 or 60 min. Reperfusion was unloaded for 20 min, and then loaded, in working-mode, for 40 min. Left ventricular (LV) pressure was monitored using a micro-tip pressure catheter introduced via the mitral valve. Several hemodynamic parameters measured during early, unloaded reperfusion correlated significantly with LV work after 60 min reperfusion (p<0.001). Coronary flow and the production of lactate and lactate dehydrogenase (LDH) also correlated significantly with outcomes after 60 min reperfusion (p<0.05). Based on early reperfusion hemodynamic measures, a composite, weighted predictive parameter, incorporating heart rate (HR), developed pressure (DP) and end-diastolic pressure, was generated and evaluated against the HR-DP product after 60 min of reperfusion. Effective discriminating ability for this novel parameter was observed for four HR*DP cut-off values, particularly for ≥20 *103 mmHg*beats*min−1 (p<0.01). Conclusion Upon reperfusion of a NHBD heart, early evaluation, at the time of organ procurement, of cardiac hemodynamic parameters, as well as easily accessible markers of metabolism and necrosis seem to accurately predict subsequent contractile recovery and could thus potentially be of use in guiding the decision of accepting the ischemic heart for transplantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To compare health-related quality of life (QoL) in patients undergoing transcatheter aortic valve implantation via transapical access (TA TAVI) with patients undergoing surgical aortic valve replacement (SAVR). METHODS One hundred and forty-four high-risk patients referred for aortic valve replacement underwent TAVI screening and were assigned to either TA TAVI (n = 51, age 79.7 ± 9.2 years, logistic EuroSCORE 26.5 ± 16.1%, 51% males) or SAVR (n = 93, age 81.1 ± 5.3 years, logistic EuroSCORE 12.1 ± 9.3%, 42% males) by the interdisciplinary heart team. QoL was assessed using the Short Form 36 (SF-36) Health Survey Questionnaire and the Hospital Anxiety and Depression Scale. Furthermore, current living conditions and the degree of independence at home were evaluated. RESULTS Patients undergoing TA TAVI were at higher risk as assessed by EuroSCORE (26.5 ± 16 vs. 12.1 ± 9, P < 0.001) and STS score (6.7 ± 4 vs. 4.4 ± 3, P < 0.001) compared with SAVR patients. At the 30-day follow-up, the rate of mortality was similar and amounted to 7.8% for TA TAVI and 7.5% for SAVR patients and raised to 25.5% in TA TAVI and 18.3% in SAVR patients after a follow-up period of 15 ± 10 months. Assessment of QoL revealed no differences in terms of anxiety and depression between TA TAVI and SAVR patients. The SF-36 mental health metascore was similar in both groups (65.6 ± 19 vs. 68.8 ± 22, P = 0.29), while a significant difference was observed in the physical health metascore (49.7 ± 21 vs. 62.0 ± 21, P = 0.015). After adjustment for baseline characteristics, this difference disappeared. However, every added point in the preoperative risk assessment with the STS score decreased the SF-36 physical health dimension by two raw points at the follow-up assessment. CONCLUSIONS Selected high-risk patients undergoing TAVI by using a transapical access achieve similar clinical outcomes and QoL compared with patients undergoing SAVR. Increased STS scores predict worse QoL outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AimsTranscatheter aortic valve implantation (TAVI) is an established treatment alternative to surgical aortic valve replacement in high-risk and inoperable patients and outcomes among patients with estimated low or intermediate risk remain to be determined. The aim of this study was to assess clinical outcomes among patients with estimated low or intermediate surgical risk undergoing TAVI.Methods and resultsBetween August 2007 and October 2011, 389 consecutive patients underwent TAVI and were categorized according to the Society of Thoracic Surgeons (STS) score into low (STS < 3%; n = 41, 10.5%), intermediate (STS ≥3% and ≤8%, n = 254, 65.3%), and high-risk (STS > 8%; n = 94, 24.2%) groups for the purpose of this study. Significant differences were found between the groups (low risk vs. intermediate risk vs. high risk) for age (78.2 ± 6.7 vs. 82.7 ± 5.7 vs. 83.7 ± 4.9, P < 0.001), body mass index (28.1 ± 6.1 vs. 26.5 ± 4.9 vs. 24.4 ± 4.6, P < 0.001), chronic renal failure (34 vs. 67 vs. 90%, P < 0.001), all-cause mortality at 30 days (2.4 vs. 3.9 vs. 14.9%, P = 0.001), and all-cause mortality at 1 year (10.1 vs. 16.1 vs. 34.5%, P = 0.0003). No differences were observed with regards to cerebrovascular accidents and myocardial infarction during 1-year follow-up.ConclusionIn contemporary practice, TAVI is not limited to inoperable or STS-defined high-risk patients and should be guided by the decision of an interdisciplinary Heart Team. Compared with patients at calculated high risk, well-selected patients with STS-defined intermediate or low risk appear to have favourable clinical outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessment of elderly patients with severe aortic stenosis and decisions in terms of management strategy (conservative with or without balloon aortic valvuloplasty, transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement) are complex and warrant a multidisciplinary approach involving collaboration between experienced cardiac surgeons, interventional cardiologists, cardiac imaging specialists, anaesthesiologists, geriatricians and a specialised nursing staff. Patient history, comorbid conditions, perioperative risk stratification as well as anatomical and procedural considerations require careful review on an individual, case-by-case basis and have a major impact on treatment allocation. The aims of this article are to provide insights into the fundamental role of appropriate patient screening and selection, and to review the nature, management and prevention of the most important procedural complications associated with the TAVI procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the current Valve Academic Research Consortium (VARC)-2 initiative was to revisit the selection and definitions of transcatheter aortic valve implantation (TAVI)clinical endpoints to make them more suitable to the present and future needs of clinical trials. In addition, this document is intended to expand the understanding of patient risk stratification and case selection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: The goal of this study was to assess the prevalence of left ventricular (LV) hypertrophy in patients with aortic stenosis late (>6 months) after aortic valve replacement and its impact on cardiac-related morbidity and mortality. METHODS AND RESULTS: In a single tertiary centre, echocardiographic data of LV muscle mass were collected. Detailed information of medical history and angiographic data were gathered. Ninety-nine of 213 patients (46%) had LV hypertrophy late (mean 5.8 +/- 5.4 years) after aortic valve replacement. LV hypertrophy was associated with impaired exercise capacity, higher New York Heart Association dyspnoea class, a tendency for more frequent chest pain expressed as higher Canadian Cardiovascular Society class, and more rehospitalizations. 24% of patients with normal LV mass vs. 39% of patients with LV hypertrophy reported cardiac-related morbidity (p = 0.04). In a multivariate logistic regression model, LV hypertrophy was an independent predictor of cardiac-related morbidity (odds ratio 2.31, 95% CI 1.08 to 5.41), after correction for gender, baseline ejection fraction, and coronary artery disease and its risk factors. Thirty seven deaths occurred during a total of 1959 patient years of follow-up (mean follow-up 9.6 years). Age at aortic valve replacement (hazard ratio 1.85, 95% CI 1.39 to 2.47, for every 5 years increase in age), coexisting coronary artery disease at the time of surgery (hazard ratio 3.36, 95% CI 1.31 to 8.62), and smoking (hazard ratio 4.82, 95% CI 1.72 to 13.45) were independent predictors of overall mortality late after surgery, but not LV hypertrophy. CONCLUSIONS: In patients with aortic valve replacement for isolated aortic stenosis, LV hypertrophy late after surgery is associated with increased morbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The chest X-ray of a 61-year-old man with severe aortic and mitral stenosis revealed extensive, circularly arranged calcifications in the wall of the left atrial appendage. He died soon after admission to hospital and autopsy confirmed the atrial calcifications in association with severe mitral stenosis. Although such calcification of the left atrial wall is rare, it can be of importance because it may make the usual surgical approach to mitral valve replacement impossible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peri-procedural bleeding complications are feared adverse events in patients undergoing transcatheter aortic valve implantation (TAVI). Little is known about the implications of peri-procedural bleeding on clinical outcome. In a prospective single-center registry of consecutive patients undergoing TAVI, we investigated incidence, predictors and clinical consequences of life-threatening and major bleeding as defined by the Valve Academic Research Consortium. Among 389 consecutive patients undergoing TAVI by a transfemoral (79.2%), transapical (19.6%) or trans-subclavian (1.3%) approach between July 2007 and October 2011, life-threatening or major peri-procedural bleeding events occurred in 64 (16.4%) and 125 patients (32.1%), respectively. Patients with peri-procedural bleeding events had a higher logistic EuroSCORE, more advanced renal disease, and were more symptomatic as assessed by New York Heart Association functional class at baseline as compared to patients with no bleeding. Life-threatening bleeding was associated with a higher all-cause (17.2 vs. 5.6 vs. 3.0%, p < 0.001) and cardiovascular mortality (10.9 vs. 5.6 vs. 2.5%, p = 0.02) at 30 days compared to patients with major bleeding or no bleeding. Multivariate analysis identified transapical access (OR 2.6, 95% CI 1.4-4.8; p = 0.002), glomerular filtration rate <30 ml/min (OR 2.3, 95% CI 1.1-4.7, p = 0.031), and diabetes (OR 1.8, 95% CI 1.001-3.2, p = 0.049) as independent predictors of life-threatening, peri-procedural bleeding. Life-threatening bleeding complications in patients undergoing TAVI are associated with increased mortality. Renal impairment, diabetes, and transapical approach were identified as independent risk factors for life-threatening bleeding events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG 2006 ± 586 vs. LEF-LG 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG 6.9 ± 1.9 vs. LEF-LG 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG 71.7% vs. LEF-LG 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.