950 resultados para Hearing tests
Resumo:
This paper examines the hysteresis hypothesis in the Brazilian industrialized exports using a time series analysis. This hypothesis finds an empirical representation into the nonlinear adjustments of the exported quantity to relative price changes. Thus, the threshold cointegration analysis proposed by Balke and Fomby [Balke, N.S. and Fomby, T.B. Threshold Cointegration. International Economic Review, 1997; 38; 627-645.] was used for estimating models with asymmetric adjustment of the error correction term. Amongst sixteen industrial sectors selected, there was evidence of nonlinearities in the residuals of long-run relationships of supply or demand for exports in nine of them. These nonlinearities represent asymmetric and/or discontinuous responses of exports to different representative measures of real exchange rates, in addition to other components of long-run demand or supply equations. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Smell identification tests may be of routine clinical value in the differential diagnosis of PD but are subject to cultural variation and have not been systematically evaluated in the Brazilian population. We have applied culturally adapted translations of the University of Pennsylvania 40-item smell identification test (UPSIT-40) and the 16-item identification test from Sniffin` Sticks (SS-16) to nondemented Brazilian PD patients and controls. Pearson`s correlation coefficient between the test scores was 0.76 (95% CI 0.70-0.81, n = 204, P < 0.001). To calculate reliability measures for each test we used the diagnosis (either PD or control) as outcome variable for separate logistic regression analyses using the score in the UPSIT-40 or the SS-16 as a covariate. The SS-16 specificity was 89.0% with a sensitivity of 81.1% (106 PD and 118 controls). The UPSIT-40 specificity was 83.5% and its sensitivity 82.1% (95 PD and 109 controls). Regression curves were used to associate an individual`s smell test score with the probability of belonging to the PD, as opposed to the control group. Our data provide support for the use of the UPSIT-40 and SS-16 to help distinguish early PD from controls. (c) 2008 Movement Disorder Society
Resumo:
Measures of vocal intensity, frequency and harshness were compared for 19 hearing-impaired and 21 normal-hearing people over 60 years of age. Significantly greater comfortable intensity levels were found in the hearing-impaired group, but the other measures of frequency and harshness were not significantly different. A large proportion of the subjects in both groups reported a history of gastro-oesophageal reflux (GER), a condition associated with vocal fold pathology and hoarseness. Comparison of the GER and non-GER subjects on the measures of vocal function showed that the female GER speaker exhibited lower frequency on the vowel /u/ than the non-GER subjects. Clinicians need to be aware of the effect of highly prevalent disorders such as hearing impairment and GER on the voices of elderly speakers.
Resumo:
Drug provocation tests (DPTs) are considered the gold standard for identifying adverse drug reactions (ADRs). The aim of this study was to analyze DPT results and discuss severe systemic reactions associated with them. This was a retrospective analysis of 500 patients with ADRs who sought treatment and were submitted to DPTs when indicated between 2006 and 2010. We performed DPTs according to the European Network for Drug Allergy recommendations. Single-blind, placebo-controlled DPTs were performed with antibiotics, local anesthetics, and nonsteroidal anti-inflammatory drugs, as well as with other drugs. Patient characteristics, DPT results, and reactions were analyzed. The sample comprised 198 patients (80.8% of whom were female patients) submitted to 243 DPTs. Ages ranged from 9 to 84 years (mean, 39.9 years). The 243 DPTs were performed with local anesthetics (n = 93), antibiotics (n = 19), acetaminophen (n = 44), benzydamine (n = 33), COX-2 inhibitors (n = 26), dipyrone (n = 7), aspirin (n = 4), or other drugs (n = 17). The results of 4 tests (1.6%) were inconclusive, whereas those of 10 (4.1%) revealed positive reactions to antibiotics (2/19), COX-2 inhibitors (2/26), acetaminophen (3/44), and local anesthetics (3/93). Two severe reactions were observed: cephalexin-induced anaphylactic shock and bupivacaine-induced anaphylaxis without shock. Four patients (2.0%) reacted to the placebo before administration of the drug. Drug provocation tests are safe for use in clinical practice but they should be placebo-controlled and should be performed under the supervision of an allergist. To confirm a presumptive diagnosis and to manage allergies appropriately, it is crucial to perform DPTs. (Allergy Asthma Proc 32:301-306, 2011; doi: 10.2500/aap.2011.32.3450)
Resumo:
Background and purpose: Tinnitus is a frequent disorder which is very difficult to treat and there is compelling evidence that tinnitus is associated with functional alterations in the central nervous system. Targeted modulation of tinnitus-related cortical activity has been proposed as a promising new treatment approach. We aimed to investigate both immediate and long-term effects of low frequency (1 Hz) repetitive transcranial magnetic stimulation (rTMS) in patients with tinnitus and normal hearing. Methods: Using a parallel design, 20 patients were randomized to receive either active or placebo stimulation over the left temporoparietal cortex for five consecutive days. Treatment results were assessed by using the Tinnitus Handicap Inventory. Ethyl cysteinate dimmer-single photon emission computed tomography (SPECT) imaging was performed before and 14 days after rTMS. Results: After active rTMS there was significant improvement of the tinnitus score as compared to sham rTMS for up to 6 months after stimulation. SPECT measurements demonstrated a reduction of metabolic activity in the inferior left temporal lobe after active rTMS. Conclusion: These results support the potential of rTMS as a new therapeutic tool for the treatment of chronic tinnitus, by demonstrating a significant reduction of tinnitus complaints over a period of at least 6 months and significant reduction of neural activity in the inferior temporal cortex, despite the stimulation applied on the superior temporal cortex.
Resumo:
The aim of this study was to establish parameters for the gaps-in-noise test in normal-hearing young adults. One hundred subjects (50 males and 50 females) received an audiological evaluation to rule out hearing loss and auditory processing disorder. The gaps-in-noise test was then conducted on all subjects. The mean gap detection threshold was 4.19 ms. A psychometric function by gap duration was constructed, revealing that the percentage of correct responses was less than or equal to 5% for a gap duration of 2 ms, 10-30% for a gap duration of 3 ms, 60-70% for a gap duration of 4 ms, and over 96% for gap durations of 5 ms or longer. The results suggest that the data obtained can be applied as reference values for future testing. In the subjects evaluated, the gaps-in-noise test proved to be consistent with low variability.
Resumo:
This study was designed to investigate the feasibility of applying tone-ABRs in the nursery and neonatal intensive care unit (NICU), and to provide normative tone-ABR data from neonates. Normative tone-ABR latency data were determined. The study obtained intensity series of tone-ABRs from thirty preterm neonates and twenty fullterm neonates who had confirmed normal peripheral auditory function after passing both an OAE and ABR screening examination. ABRs were collected in response to 500, 1500, and 4000 Hz tone bursts at 70, 50, 30, and 20 dB nHL. Mean wave V latencies were compared between groups, ears, and by gender. Responses to tone bursts of 20 and 30 dB nHL were detected in 97% and 100% of all ears respectively, in addition to responses to the higher-intensity stimuli. Preterm neonates` ABRs showed significantly longer latencies than those of the full-term infants. Tone-ABR evaluation was found to be both feasible and reliable as a measure of auditory function in neonates.
Resumo:
Background. The formation and measurement of self-concept were the foci of this research. Aims. The study aimed to investigate the influence of achievement on academic self-concept and to compare the Perception of Ability Scale for Students (PASS, Boersma & Chapman, 1992) with the Self-Description Questionnaire-1 (SDQ-1, Marsh, 1988). Sample. The participants were 479 grade 5 (mean age 126.6 months) coeducational Australian students, located in 18 schools. Method. An intra-class research design was used to investigate the influence of frame-of-reference on self-concept development. Results. As students' academic scores rose above their class mean their self-concepts increased and as students' academic scores fell below their class mean their self-concepts decreased. Students' difference from class mean predicted their self-concept scores. This finding was consistently shown across the reading, spelling, and mathematics domains using test and teaching rating data. A comparison between the PASS and the SDQ-1 demonstrated concurrent validity across self-concept domains. Conclusion. The findings support the notions that the social environment is a significant agent that influences self-concept, and that teacher ratings and standardised tests of achievement and the PASS and the SDQ-1 are valid measures for self-concept research.
Resumo:
Aims: To compare the performance of schizophrenia, mania and well control groups on tests sensitive to impaired executive ability, and to assess the within-group stability of these measures across the acute and subacute phases of psychoses. Method: Recently admitted patients with schizophrenia (n=36), mania (n=18) and a well control group (n=20) were assessed on two occasions separated by 4 weeks. Tests included: the Controlled Oral Word Association Test, the Stroop Test, the Wisconsin Card Sort Test, and the Trail Making Test. Results: The two patient groups were significantly impaired on the Stroop Test at both time points compared to the control group. Significant group differences were also found for the Trail Making Test at Time 1 and for the Wisconsin Card Sort Test at Time 2. When controlled for practice effect, significant improvements over time were found on the Stroop and Trail Making tests in the schizophrenia group and on WCST Categories Achieved in the mania group. Discussion: Compared to controls, the patient groups were impaired on measures related to executive ability. The pattern of improvement on test scores between the acute and subacute phases differed between patients with schizophrenia versus patients with mania. (C) 1997 Elsevier Science B.V.
Resumo:
The objective was to determine the reliability of isokinetic strength and endurance testing in the ankle joints of patients with intermittent claudication. Twenty-three patients with peripheral artery disease (PAD) and symptoms of intermittent claudication participated in the study. Isokinetic strength and endurance testing of the ankle joint were performed in symptomatic and asymptomatic legs on 3 separate days. Intraclass coefficient correlation of peak torque (PT) and total work (TW) ranged from 0.77 to 0.92 and 0.89 to 0.96, respectively. PT and TW increased significantly and similarly in both legs from day 1 to day 2 (PT: +42 +/- 84% in the symptomatic leg and +33 +/- 51% in the asymptomatic leg, p < 0.05;TW: +38 +/- 26% in the symptomatic leg and +26 +/- 50% in the asymptomatic leg, p < 0.05). In conclusion, isokinetic strength and endurance testing in the ankle joints of patients with PAD presents reliability coefficients ranging from 0.77 to 0.96. However, strength and endurance increased between the first and the other test sessions performed on separate days, suggesting that two test sessions are necessary for the accurate evaluation of strength and endurance in patients with PAD.
Resumo:
The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).
Resumo:
Tinnitus is a symptom present in approximately 15% of the world population. Most patients are between 40 and 80 years of age; the prevalence above 60 reaches 33%. About 20% have moderate to severe impact in the quality of life but the factors associated with the tinnitus annoyance are not completely known. Aim: The objective of this study is to evaluate the relationship between age, gender and hearing loss on tinnitus annoyance. Materials and methods: 68 patients were evaluated at the tinnitus center at our hospital, from March 2007 to march 2008, with a detailed interview, complete otolaryngological examination, the Portuguese version of the Tinnitus Handicap Inventory and pure tone audiometry. Results: Age varied from 24 to 83 (mean=59); the mean THI value was 39 (females: 36; males: 44). THI grades were: slight: 32.3%; mild: 19.1%; moderate: 20.6%; severe: 13.2% and catastrophic: 14.7%. No significant correlation was found between gender (p=0.30), age (p=0.77) hearing loss (p>0.05 for all averages analyzed) and tinnitus severity. Conclusion: Gender, age and hearing loss do not influence tinnitus annoyance, using the THI.
Resumo:
Purpose of review This review discusses ovarian reserve tests for ovulation induction and their application in determining fertility capacity, and their current applications to assess risk of natural ovarian failure and to estimate ovarian function after cancer treatment. Recent findings The current arsenal of ovarian reserve tests comprises hormonal markers [basal follicle stimulating hormone, estradiol, inhibin-B, antimullerian hormone (AMH)] and ultrasonographic markers [ovarian volume, antral follicle counts (AFCs)]. These markers have limitations in terms of which test(s) should be used to reliably predict ovarian reserve with regard to accuracy, invasiveness, cost, convenience, and utility. Several studies have correlated sonographic AFCs with serum AMH levels for predicting the ovarian response to ovulation induction protocols during assisted reproduction treatments. Summary Serum AMH levels and AFC are reliable tests for predicting the ovarian response to ovulation induction. However, none of the currently employed tests of ovarian reserve can reliably predict pregnancy after assisted conception. Further, ovarian reserve tests cannot predict the onset of reproductive and hormonal menopause; thus, they should be used with caution for reproductive life-programming counseling. Moreover, there is no evidence to support the use of ovarian reserve tests to estimate the risk of ovarian sufficiency after cancer treatments.
Resumo:
Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. Aim: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. Materials and Methods: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. Results: The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p=0.044), discomfort with the sound intensity in the work place (p=0.009) and intolerance to loud sound (p=0.029). Conclusions: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.