837 resultados para Head tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The specific status of the head and body lice of humans has been debated for more than 200 yr. To clarify the specific status of head and body lice, we sequenced 524 base pairs (bp) of the cytochrome oxidase I (COI) gene of 28 head and 28 body lice from nine countries. Ten haplotypes that differed by 1-5 bp at II nucleotide positions were identified. A phylogeny of these sequences indicates that these head and body lice are not from reciprocally monophyletic lineages. Indeed, head and body lice share three of the 10 haplotypes we found. F-ST values and exact tests of haplotype frequencies showed significant differences between head and body lice. However, the same tests also showed significant differences among lice from different countries. Indeed, more of the variation in haplotype frequencies was explained by differences among lice from different countries than by differences between head and body lice. Our results indicate the following: (1) bead and body lice do not represent reciprocally monophyletic lineages and are conspecific; (2) gene flow among populations of lice from different countries is limited; and (3) frequencies of COI haplotypes can be used to study maternal gene flow among populations of head and body lice and thus transmission of lice among their human hosts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine the pharmacokinetics of [C-14]diclofenac, [C-14]salicylate and [H-3]clonidine using a single pass rat head perfusion preparation. The head was perfused with 3-[N-morpholino] propane-sulfonic acid-buffered Ringer's solution. Tc-99m-red blood cells and a drug were injected in a bolus into the internal carotid artery and collected from the posterior facial vein over 28 min. A two-barrier stochastic organ model was used to estimate the statistical moments of the solutes. Plasma, interstitial and cellular distribution volumes for the solutes ranged from 1.0 mL (diclofenac) to 1.6 mL (salicylate), 2.0 mL (diclofenac) to 4.2 mL (water) and 3.9 mL (salicylate) to 20.9 mL (diclofenac), respectively. A comparison of these volumes to water indicated some exclusion of the drugs from the interstitial space and salicylate from the cellular space. Permeability-surface area (PS) products calculated from plasma to interstitial fluid permeation clearances (CLPI) (range 0.02-0.40 mL s(-1)) and fractions of solute unbound in the perfusate were in the order: diclofenac>salicylate >clonidine>sucrose (from 41.8 to 0.10 mL s(-1)). The slow efflux of diclofenac, compared with clonidine and salicylate, may be related to its low average unbound fraction in the cells. This work accounts for the tail of disposition curves in describing pharmacokinetics in the head.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim of this study was to examine minor physical anomalies and quantitative measures of the head and face in patients with psychosis vs healthy controls. Methods: Based on a comprehensive prevalence study of psychosis, we recruited 310 individuals with psychosis and 303 controls. From this sample, we matched 180 case-control pairs for age and sex. Individual minor physical anomalies and quantitative measures related to head size and facial height and depth were compared within the matched pairs. Based on all subjects, we examined the specificity of the findings by comparing craniofacial summary scores in patients with nonaffective or affective psychosis and controls. Results: The odds of having a psychotic disorder were increased in those with wider skull bases (odds ratio [OR], 1.40; 95% confidence interval [CI], 1.02-1.17), smaller lower-facial heights (glabella to subnasal) (OR, 0.57; 95% CI, 0.44-0.75), protruding ears (OR, 1.72; 95% CI, 1.05-2.82), and shorter (OR, 2.29; 95% CI, 1.37-3.82) and wider (OR, 2.28; 95% CI, 1.43-3.65) palates. Compared with controls, those with psychotic disorder had skulls that were more brachycephalic. These differences were found to distinguish patients with nonaffective and affective psychoses from controls. Conclusions: Several of the features that differentiate patients from controls relate to the development of the neuro-basicranial complex and the adjacent temporal and frontal lobes. Future research should examine both the temporal lobe and the middle cranial fossa to reconcile our anthropomorphic findings and the literature showing smaller temporal lobes in patients with schizophrenia. Closer attention to the skull base may provide clues to the nature and timing of altered brain development in patients with psychosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several anomalies occur in the developing neural and visceral head skeleton of young specimens of Neoceratodus forsteri that have been reared under laboratory conditions. These include anomalies of the basicranium and its derivatives, aberrations of the anterior mandible and hyoid apparatus, and abnormalities in the articulation of the jaws and the elements that produce them. Apart from the occasional absence of the basihyal, and failure of the quadrate processes to form, the anomalies are not deficiencies. Most involve malformations of parts of the neurocranium and visceral skeleton, inappropriate articulations or fusions between elements, disunity in structures that are normally fused and the appearance of supernumerary elements. The incidence of chondral anomalies, generally higher than aberrations that occur in the dermal skeleton in juvenile lungfish, ranges from 1-10% in laboratory reared individuals that have not been subjected to experimental interference. The anomalies differ from those found in many amphibian populations, in the field and in the laboratory, because they involve the cranium, and not the limbs, and the lungfish have not been exposed to the factors that cause anomalies in the amphibians. It is unlikely that the existence of those anomalies, if it is reflected in the wild population, places a selective pressure on the lungfish, because, in a normal season, less than 1% of the total number of eggs produced survive to be recruited into the adult population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infestation with head lice, Pediculus humanus capitis, is a worldwide problem, especially among primary (elementary) school children. Although studies in many different countries indicate lower levels of susceptibility to certain insecticides than expected ('resistance'), there is no empirical data from Australia. Data on the susceptibility of head lice to malathion, pyrethrums and permethrin were collected from four schools in Brisbane and one school in northern Queensland. Since no completely susceptible strain of head lice was available and head lice are difficult to keep in culture, a completely susceptible strain of body lice, Pediculus humanus humanus, was used for reference. All five groups of head lice were less susceptible to malathion, pyrethrums and permethrin than were lice from the reference strain. Moreover, the degree of susceptibility to these insecticides varied substantially among schools. Thus, a pediculicide that controlled lice at one school in Brisbane would not necessarily control head lice at another school in the same city. These preliminary data indicate that detailed information on the susceptibility of the different populations of head lice in Queensland to the different insecticides available is needed to maximize the chance of effective control of these increasingly common parasites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the pioneering work of Charles Nicolle in 1909 [see Gross (1996) Proc Natl Acad Sci USA 93:10539-10540] most medical officers and scientists have assumed that body lice are the sole vectors of Rickettsia prowazekii, the aetiological agent of louse-borne epidemic typhus (LBET). Here we review the evidence for the axiom that head lice are not involved in epidemics of LBET. Laboratory experiments demonstrate the ability of head lice to transmit R. prowazekii, but evidence for this in the field has not been reported. However, the assumption that head lice do not transmit R. prowazekii has meant that head lice have not been examined for R. prowazekii during epidemics of LBET. The strong association between obvious (high) infestations of body lice and LBET has contributed to this perception, but this association does not preclude head lice as vectors of R. prowazekii. Indeed, where the prevalence and intensity of body louse infections may be high (e.g. during epidemics of LBET), the prevalence and intensity of head louse infestations is generally high as well. This review of the epidemiology of head louse and body louse infestations, and of LBET, indicates that head lice are potential vectors of R. prowazekii in the field. Simple observations in the field would reveal whether or not head lice are natural vectors of this major human pathogen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a method for real-time detection and tracking of people in video captured by a depth camera. For each object to be assessed, an ordered sequence of values that represents the distances between its center of mass to the boundary points is calculated. The recognition is based on the analysis of the total distance value between the above sequence and some pre-defined human poses, after apply the Dynamic Time Warping. This similarity approach showed robust results in people detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Precise needle puncture of the renal collecting system is an essential but challenging step for successful percutaneous nephrolithotomy. We evaluated the efficiency of a new real-time electromagnetic tracking system for in vivo kidney puncture. Materials and Methods: Six anesthetized female pigs underwent ureterorenoscopy to place a catheter with an electromagnetic tracking sensor into the desired puncture site and ascertain puncture success. A tracked needle with a similar electromagnetic tracking sensor was subsequently navigated into the sensor in the catheter. Four punctures were performed by each of 2 surgeons in each pig, including 1 each in the kidney, middle ureter, and right and left sides. Outcome measurements were the number of attempts and the time needed to evaluate the virtual trajectory and perform percutaneous puncture. Results: A total of 24 punctures were easily performed without complication. Surgeons required more time to evaluate the trajectory during ureteral than kidney puncture (median 15 seconds, range 14 to 18 vs 13, range 11 to 16, p ¼ 0.1). Median renal and ureteral puncture time was 19 (range 14 to 45) and 51 seconds (range 45 to 67), respectively (p ¼ 0.003). Two attempts were needed to achieve a successful ureteral puncture. The technique requires the presence of a renal stone for testing. Conclusions: The proposed electromagnetic tracking solution for renal collecting system puncture proved to be highly accurate, simple and quick. This method might represent a paradigm shift in percutaneous kidney access techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hand and finger tracking has a major importance in healthcare, for rehabilitation of hand function required due to a neurological disorder, and in virtual environment applications, like characters animation for on-line games or movies. Current solutions consist mostly of motion tracking gloves with embedded resistive bend sensors that most often suffer from signal drift, sensor saturation, sensor displacement and complex calibration procedures. More advanced solutions provide better tracking stability, but at the expense of a higher cost. The proposed solution aims to provide the required precision, stability and feasibility through the combination of eleven inertial measurements units (IMUs). Each unit captures the spatial orientation of the attached body. To fully capture the hand movement, each finger encompasses two units (at the proximal and distal phalanges), plus one unit at the back of the hand. The proposed glove was validated in two distinct steps: a) evaluation of the sensors’ accuracy and stability over time; b) evaluation of the bending trajectories during usual finger flexion tasks based on the intra-class correlation coefficient (ICC). Results revealed that the glove was sensitive mainly to magnetic field distortions and sensors tuning. The inclusion of a hard and soft iron correction algorithm and accelerometer and gyro drift and temperature compensation methods provided increased stability and precision. Finger trajectories evaluation yielded high ICC values with an overall reliability within application’s satisfying limits. The developed low cost system provides a straightforward calibration and usability, qualifying the device for hand and finger tracking in healthcare and animation industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In daily cardiology practice, assessment of left ventricular (LV) global function using non-invasive imaging remains central for the diagnosis and follow-up of patients with cardiovascular diseases. Despite the different methodologies currently accessible for LV segmentation in cardiac magnetic resonance (CMR) images, a fast and complete LV delineation is still limitedly available for routine use. In this study, a localized anatomically constrained affine optical flow method is proposed for fast and automatic LV tracking throughout the full cardiac cycle in short-axis CMR images. Starting from an automatically delineated LV in the end-diastolic frame, the endocardial and epicardial boundaries are propagated by estimating the motion between adjacent cardiac phases using optical flow. In order to reduce the computational burden, the motion is only estimated in an anatomical region of interest around the tracked boundaries and subsequently integrated into a local affine motion model. Such localized estimation enables to capture complex motion patterns, while still being spatially consistent. The method was validated on 45 CMR datasets taken from the 2009 MICCAI LV segmentation challenge. The proposed approach proved to be robust and efficient, with an average distance error of 2.1 mm and a correlation with reference ejection fraction of 0.98 (1.9 ± 4.5%). Moreover, it showed to be fast, taking 5 seconds for the tracking of a full 4D dataset (30 ms per image). Overall, a novel fast, robust and accurate LV tracking methodology was proposed, enabling accurate assessment of relevant global function cardiac indices, such as volumes and ejection fraction.