893 resultados para Head neck


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction . Compared to most equine horse breeds which are able to walk, trot and canter /gallop, the gait repertoire of the Icelandic horses additionally includes the lateral gait tölt and frequently also the pace. With respect to the tölt gait, special shoeing, saddling and riding techniques have been developed for Icelandic horses in order to enhance its expressiveness and regularity. Toes are left unnaturally long and heavy shoes and paddings, as well as weighted boots are used to enforce the individual gait predisposition. For the same reason, the rider is placed more caudally to the horse's centre of mass as compared to other riding techniques. The biomechanical impact of these methods on the health of the locomotor system has so far never been subject of systematic research. Objectives . The aims of the presented study are (1) to describe the kinetic and kinematic characteristics of the tölt performed on a treadmill, (2) to understand the mechanical consequences of shoeing manipulation (long hooves, weighted boots) on the loading and protraction movement of the limbs, as well as (3) to study the pressure distribution and effects on the gait pattern of 3 different saddle types used for riding Icelandic horses. Materials and methods . Gait analysis was carried out in 13 Icelandic horses at walk and at slow and medium tölting and trotting speeds on a high-speed treadmill instrumented for measuring vertical ground reaction forces as well as temporal and spatial gait variables. Kinematic data of horse, rider and saddle were measured simultaneously. Gait analysis was first carried out with high, long hooves (SH) without and in combination with weighted boots (ad aim (2)). Afterwards, horses were re-shod according to current horseshoeing standards (SN) and gait analysis was repeated (ad aims (1) and (2)). In a second trial, horses were additionally equipped with a pressure sensitive saddle mat and were ridden with a dressage-like saddle (SDres), an Icelandic saddle (Slcel) and a saddle cushion (SCush) in the standard saddle position (ad aim 3). Results and conclusions . Compared to trot at the same speed, tölting horses had a higher stride rate and lower stride impulses. At the tölt loading of the forelimbs was increased in form of higher peak vertical forces (Fzpeak) due to shorter relative stance durations (StDrel). Conversely, in the hindlimbs, longer StDrel resulted in lower Fzpeak. Despite the higher head-neck position at tölt, there was no measurable shift in weight to the hindlimbs. Footfall rhythm was in most horses laterally coupled at the tölt and frequently had a slight fourbeat and a very short suspension phase at trot; underlining the fact that performance of correct gaits in Icelandic horses needs special training. Gait performance as it is currently judged in competition could be improved using a shoeing with SH, resulting in a 21 ± 5 mm longer dorsal hoof wall, but also a weight gain of 273 ± 50 g at the distal limb due to heavier shoeing material. Compared to SN, SH led to a lower stride rate, a longer stride length and a higher, but not wider, forelimb protraction arc, which were also positively associated with speed. At the tölt, the footfall rhythm showed less tendency to lateral couplets and at the trot, the suspension phase was longer. However, on the long term, SH may have negative implications for the health of the palmar structures of the distal foot by increased limb impulses, higher torques at breakover (up to 20%); as well as peak vertical forces at faster speeds. Compared to the shoeing style, the saddle type had less influence on limb forces or movements. The slight weight shift to the rear with SCush and Slcel may be explained by the more caudal position of the rider relative to the horse's back. With SCush, pressure was highest under the cranial part of the saddle, whereas the saddles with trees had more pressure under the caudal area.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The association between combination antiretroviral therapy (cART) and cancer risk, especially regimens containing protease inhibitors (PIs) or nonnucleoside reverse transcriptase inhibitors (NNRTIs), is unclear. METHODS Participants were followed from the latest of D:A:D study entry or January 1, 2004, until the earliest of a first cancer diagnosis, February 1, 2012, death, or 6 months after the last visit. Multivariable Poisson regression models assessed associations between cumulative (per year) use of either any cART or PI/NNRTI, and the incidence of any cancer, non-AIDS-defining cancers (NADC), AIDS-defining cancers (ADC), and the most frequently occurring ADC (Kaposi sarcoma, non-Hodgkin lymphoma) and NADC (lung, invasive anal, head/neck cancers, and Hodgkin lymphoma). RESULTS A total of 41,762 persons contributed 241,556 person-years (PY). A total of 1832 cancers were diagnosed [incidence rate: 0.76/100 PY (95% confidence interval: 0.72 to 0.79)], 718 ADC [0.30/100 PY (0.28-0.32)], and 1114 NADC [0.46/100 PY (0.43-0.49)]. Longer exposure to cART was associated with a lower ADC risk [adjusted rate ratio: 0.88/year (0.85-0.92)] but a higher NADC risk [1.02/year (1.00-1.03)]. Both PI and NNRTI use were associated with a lower ADC risk [PI: 0.96/year (0.92-1.00); NNRTI: 0.86/year (0.81-0.91)]. PI use was associated with a higher NADC risk [1.03/year (1.01-1.05)]. Although this was largely driven by an association with anal cancer [1.08/year (1.04-1.13)], the association remained after excluding anal cancers from the end point [1.02/year (1.01-1.04)]. No association was seen between NNRTI use and NADC [1.00/year (0.98-1.02)]. CONCLUSIONS Cumulative use of PIs may be associated with a higher risk of anal cancer and possibly other NADC. Further investigation of biological mechanisms is warranted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Between 2005 and 2012, annual sales of E-bikes in Switzerland increased from 1,792 to 52,941. This continuous and rapid transition from human-powered bicycles to an electric bicycle technology may indicate the increasing demand for low-cost transportation technology in combination with a healthy lifestyle. Material and Methods. In the present study, from April 2012 to September 2013, we retrospectively analysed E-bike accidents treated in the Emergency Department of our hospital by focusing on the following parameters: age, gender, time, period, and cause of the accident, as well as injury and outcome. Results. Patients were predominantly male. The mean age of injured E-cyclists was 47.5 years. The main causes of injury were self-accident. Most injuries were to the head/neck. The mean ISS was 8.48. The outcome showed that 9 patients were treated as outpatients, 9 were inpatients, and 5 patients were kept in the Intensive Care Unit (ICU). Only six patients underwent surgery (S). Discussion. This is the first attempt to evaluate E-bike injuries in Switzerland in an acute hospital setting. Since there is increasing popular preference for E-bikes as means of transportation and injuries to the head or neck are prevalent among E-cyclists, the hazard should not to be underestimated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND We previously reported the 5-year followup of hips with femoroacetabular impingement (FAI) that underwent surgical hip dislocation with trimming of the head-neck junction and/or acetabulum including reattachment of the labrum. The goal of this study was to report a concise followup of these patients at a minimum 10 years. QUESTIONS/PURPOSES We asked if these patients had (1) improved hip pain and function; we then determined (2) the 10-year survival rate and (3) calculated factors predicting failure. METHODS Between July 2001 and March 2003, we performed surgical hip dislocation and femoral neck osteoplasty and/or acetabular rim trimming with labral reattachment in 75 patients (97 hips). Of those, 72 patients (93 hips [96%]) were available for followup at a minimum of 10 years (mean, 11 years; range, 10-13 years). We used the anterior impingement test to assess pain and the Merle d'Aubigné-Postel score to assess function. Survivorship calculation was performed using the method of Kaplan and Meier and any of the following factors as a definition of failure: conversion to total hip arthroplasty (THA), radiographic evidence of worsening osteoarthritis (OA), or a Merle d'Aubigné-Postel score less than 15. Predictive factors for any of these failures were calculated using the Cox regression analysis. RESULTS At 10-year followup, the prevalence of a positive impingement test decreased from preoperative 95% to 38% (p < 0.001) and the Merle d'Aubigné-Postel score increased from preoperative 15.3 ± 1.4 (range, 9-17) to 16.9 ± 1.3 (12-18; p < 0.001). Survivorship of these procedures for any of the defined failures was 80% (95% confidence interval, 72%-88%). The strongest predictors of failure were age > 40 years (hazard ratio with 95% confidence interval, 5.9 [4.8-7.1], p = 0.002), body mass index > 30 kg/m(2) (5.5 [3.9-7.2], p = 0.041), a lateral center-edge angle < 22° or > 32° (5.4 [4.2-6.6], p = 0.006), and a posterior acetabular coverage < 34% (4.8 [3.7-5.6], p = 0.006). CONCLUSIONS At 10-year followup, 80% of patients with FAI treated with surgical hip dislocation, osteoplasty, and labral reattachment had not progressed to THA, developed worsening OA, or had a Merle d'Aubigné-Postel score of less than 15. Radiographic predictors for failure were related to over- and undertreatment of acetabular rim trimming.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND In some hips with cam-type femoroacetabular impingement (FAI), we observed a morphology resembling a more subtle form of slipped capital femoral epiphysis (SCFE). Theoretically, the morphology in these hips should differ from hips with a primary cam-type deformity. QUESTIONS/PURPOSES We asked if (1) head-neck offset; (2) epiphyseal angle; and (3) tilt angle differ among hips with a slip-like morphology, idiopathic cam, hips after in situ pinning of SCFE, and normal hips; and (4) what is the prevalence of a slip-like morphology among cam-type hips? METHODS We retrospectively compared the three-dimensional anatomy of hips with a slip-like morphology (29 hips), in situ pinning for SCFE (eight hips), idiopathic cam deformity (171 hips), and 30 normal hips using radial MRI arthrography. Normal hips were derived from 17 asymptomatic volunteers. All other hips were recruited from a series of 277 hips (243 patients) seen at a specialized academic hip center between 2006 and 2010. Forty-one hips with isolated pincer deformity were excluded. Thirty-six of 236 hips had a known cause of cam impingement (secondary cam), including eight hips after in situ pinning of SCFE (postslip group). The 200 hips with a primary cam were separated in hips with a slip-like morphology (combination of positive fovea sign [if the neck axis did not intersect with the fovea capitis] and a tilt angle [between the neck axis and perpendicular to the basis of the epiphysis] exceeding 4°) and hips with an idiopathic cam. We evaluated offset ratio, epiphyseal angle (angle between the neck axis and line connecting the center of the femoral head and the point where the physis meets the articular surface), and tilt angle circumferentially around the femoral head-neck axis. Prevalence of slip-like morphology was determined based on the total of 236 hips with cam deformities. RESULTS Offset ratio was decreased anterosuperiorly in idiopathic cam, slip-like, and postslip (eg, 1 o'clock position with a mean offset ranging from 0.00 to 0.14; p < 0.001 for all groups) compared with normal hips (0.25 ± 0.06 [95% confidence interval, 0.13-0.37]) and increased posteroinferiorly in slip-like (eg, 8 o'clock position, 0.5 ± 0.09 [0.32-0.68]; p < 0.001) and postslip groups (0.55 ± 0.12 [0.32-0.78]; p < 0.001) and did not differ in idiopathic cam (0.32 ± 0.09 [0.15-0.49]; p = 0.323) compared with normal (0.31 ± 0.07 [0.18-0.44]) groups. Epiphyseal angle was increased anterosuperiorly in the slip-like (eg, 1 o'clock position, 70° ± 9° [51°-88°]; p < 0.001) and postslip groups (75° ± 13° [49°-100°]; p = 0.008) and decreased in idiopathic cam (50° ± 8° [35°-65°]; p < 0.001) compared with normal hips (58° ± 8° [43°-74°]). Posteroinferiorly, epiphyseal angle was decreased in slip-like (eg, 8 o'clock position, 54° ± 10° [34°-74°]; p < 0.001) and postslip (44° ± 11° [23°-65°]; p < 0.001) groups and did not differ in idiopathic cam (76° ± 8° [61°-91°]; p = 0.099) compared with normal (73° ± 7° [59°-88°]) groups. Tilt angle increased in slip-like (eg, 2/8 o'clock position, 14° ± 8° [-1° to 30°]; p < 0.001) and postslip hips (29° ± 10° [9°-48°]; p < 0.001) and decreased in hips with idiopathic cam (-7° ± 5° [-17° to 4°]; p < 0.001) compared with normal (-1° ± 5° [-10° to 8°]) hips. The prevalence of a slip-like morphology was 12%. CONCLUSIONS The slip-like morphology is the second most frequent pathomorphology in hips with primary cam deformity. MRI arthrography of the hip allows identifying a slip-like morphology, which resembles hips after in situ pinning of SCFE and distinctly differs from hips with idiopathic cam. These results support previous studies reporting that SCFE might be a risk factor for cam-type FAI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Severe pincer impingement (acetabular protrusio) is an established cause of hip pain and osteoarthritis. The proposed underlying pathomechanism is a dynamic pathological contact of the prominent acetabular rim with the femoral head-neck junction. However, this cannot explain the classically described medial osteoarthritis in these hips. We therefore asked: (1) Does an overload exist in the medial aspect of the protrusio joint? and (2) What is the influence of three contemporary joint-preserving procedures on load distribution in protrusio hips? In vivo force and motion data for walking and standing to sitting were applied to six 3D finite element models (normal, dysplasia, protrusio, acetabular rim trimming, acetabular reorientation, and combined reorientation/rim trimming). Compared with dysplasia, the protrusio joint resulted in opposite patterns of von Mises stress and contact pressure during walking. In protrusio hips, we found an overload at the medial margin of the lunate surface (54% higher than normal). Isolated rim trimming further increased the medial overload (up to 28% higher than protrusio), whereas acetabular reorientation with/without rim trimming reduced stresses by up to 25%. Our results can be used as an adjunct for surgical decision making in the treatment of acetabular protrusio.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. MATERIALS AND METHODS Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. RESULTS A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. CONCLUSIONS The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Femoroacetabular impingement (FAI) is a dynamic conflict of the hip defined by a pathological, early abutment of the proximal femur onto the acetabulum or pelvis. In the past two decades, FAI has received increasing focus in both research and clinical practice as a cause of hip pain and prearthrotic deformity. Anatomical abnormalities such as an aspherical femoral head (cam-type FAI), a focal or general overgrowth of the acetabulum (pincer-type FAI), a high riding greater or lesser trochanter (extra-articular FAI), or abnormal torsion of the femur have been identified as underlying pathomorphologies. Open and arthroscopic treatment options are available to correct the deformity and to allow impingement-free range of motion. In routine practice, diagnosis and treatment planning of FAI is based on clinical examination and conventional imaging modalities such as standard radiography, magnetic resonance arthrography (MRA), and computed tomography (CT). Modern software tools allow three-dimensional analysis of the hip joint by extracting pelvic landmarks from two-dimensional antero-posterior pelvic radiographs. An object-oriented cross-platform program (Hip2Norm) has been developed and validated to standardize pelvic rotation and tilt on conventional AP pelvis radiographs. It has been shown that Hip2Norm is an accurate, consistent, reliable and reproducible tool for the correction of selected hip parameters on conventional radiographs. In contrast to conventional imaging modalities, which provide only static visualization, novel computer assisted tools have been developed to allow the dynamic analysis of FAI pathomechanics. In this context, a validated, CT-based software package (HipMotion) has been introduced. HipMotion is based on polygonal three-dimensional models of the patient’s pelvis and femur. The software includes simulation methods for range of motion, collision detection and accurate mapping of impingement areas. A preoperative treatment plan can be created by performing a virtual resection of any mapped impingement zones both on the femoral head-neck junction, as well as the acetabular rim using the same three-dimensional models. The following book chapter provides a summarized description of current computer-assisted tools for the diagnosis and treatment planning of FAI highlighting the possibility for both static and dynamic evaluation, reliability and reproducibility, and its applicability to routine clinical use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acetabular retroversion is the result of an externally rotated hemipelvis rather than a focal overgrowth of the anterior wall and/or hypoplasia of the posterior wall. Acetabular retroversion is a cause of pincer impingement which, if left untreated, can lead to hip pain and osteoarthritis. The causal surgical treatment in hips with acetabular retroversion is acetabular reorientation with a reverse periacetabular osteotomy (PAO). Indication is based on a positive correlation among symptoms (typically groin pain), physical findings on examination (positive anterior impingement test and decreased flexion and internal rotation), and radiographic signs for acetabular retroversion. These include a positive crossover, posterior wall, and ischial spine sign. A reverse PAO is performed with four osteotomies and a controlled fracture. Unlike reorientation of the acetabular fragment in dysplastic hips, correction for acetabular retroversion is achieved by a combined extension and internal rotation of the acetabular fragment. Typically, a small supra-acetabular wedge resection is required to allow sufficient extension of the fragment. The quality of acetabular reorientation is evaluated by intraoperative AP pelvic radiographs. In addition, intraoperative testing of range of motion following acetabular reorientation is mandatory. An arthrotomy and offset correction of the femoral head-neck area is indicated in hips with decreased internal rotation following acetabular reorientation. In a 10-year follow-up study of reverse PAO, a favorable outcome with preservation of all native joints was found. Correct acetabular orientation and, if necessary, a concomitant offset correction were the keys of successful outcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El actual proyecto consiste en la creación de una interfaz gráfica de usuario (GUI) en entorno de MATLAB que realice una representación gráfica de la base de datos de HRTF (Head-Related Transfer Function). La función de transferencia de la cabeza es una herramienta muy útil en el estudio de la capacidad del ser humano para percibir su entorno sonoro, además de la habilidad de éste en la localización de fuentes sonoras en el espacio que le rodea. La HRTF biaural (terminología para referirse al conjunto de HRTF del oído izquierdo y del oído derecho) en sí misma, posee información de especial interés ya que las diferencias entre las HRTF de cada oído, conceden la información que nuestro sistema de audición utiliza en la percepción del campo sonoro. Por ello, la funcionalidad de la interfaz gráfica creada presenta gran provecho dentro del estudio de este campo. Las diferencias interaurales se caracterizan en amplitud y en tiempo, variando en función de la frecuencia. Mediante la transformada inversa de Fourier de la señal HRTF, se obtiene la repuesta al impulso de la cabeza, es decir, la HRIR (Head-Related Impulse Response). La cual, además de tener una gran utilidad en la creación de software o dispositivos de generación de sonido envolvente, se utiliza para obtener las diferencias ITD (Interaural Time Difference) e ILD (Interaural Time Difference), comúnmente denominados “parámetros de localización espacial”. La base de datos de HRTF contiene la información biaural de diferentes puntos de ubicación de la fuente sonora, formando una red de coordenadas esféricas que envuelve la cabeza del sujeto. Dicha red, según las medidas realizadas en la cámara anecoica de la EUITT (Escuela Universitaria de Ingeniería Técnica de Telecomunicación), presenta una precisión en elevación de 10º y en azimut de 5º. Los receptores son dos micrófonos alojados en el maniquí acústico llamado HATS (Hats and Torso Simulator) modelo 4100D de Brüel&Kjaer. Éste posee las características físicas que influyen en la percepción del entorno como son las formas del pabellón auditivo (pinna), de la cabeza, del cuello y del torso humano. Será necesario realizar los cálculos de interpolación para todos aquellos puntos no contenidos en la base de datos HRTF, este proceso es sumamente importante no solo para potenciar la capacidad de la misma sino por su utilidad para la comparación entre otras bases de datos existentes en el estudio de este ámbito. La interfaz gráfica de usuario está concebida para un manejo sencillo, claro y predecible, a la vez que interactivo. Desde el primer boceto del programa se ha tenido clara su filosofía, impuesta por las necesidades de un usuario que busca una herramienta práctica y de manejo intuitivo. Su diseño de una sola ventana reúne tanto los componentes de obtención de datos como los que hacen posible la representación gráfica de las HRTF, las HRIR y los parámetros de localización espacial, ITD e ILD. El usuario podrá ir alternando las representaciones gráficas a la vez que introduce las coordenadas de los puntos que desea visualizar, definidas por phi (elevación) y theta (azimut). Esta faceta de la interfaz es la que le otorga una gran facilidad de acceso y lectura de la información representada en ella. Además, el usuario puede introducir valores incluidos en la base de datos o valores intermedios a estos, de esta manera, se indica a la interfaz la necesidad de realizar la interpolación de los mismos. El método de interpolación escogido es el de la ponderación de la distancia inversa entre puntos. Dependiendo de los valores introducidos por el usuario se realizará una interpolación de dos o cuatro puntos, siendo éstos limítrofes al valor introducido, ya sea de phi o theta. Para añadir versatilidad a la interfaz gráfica de usuario, se ha añadido la opción de generar archivos de salida en forma de imagen de las gráficas representadas, de tal forma que el usuario pueda extraer los datos que le interese para cualquier valor de phi y theta. Se completa el presente proyecto fin de carrera con un trabajo de investigación y estudio comparativo de la función y la aplicación de las bases de datos de HRTF dentro del marco científico y de investigación. Esto ha hecho posible concentrar información relacionada a través de revistas científicas de investigación como la JAES (Journal of the Audio Engineering Society) o la ASA (Acoustical Society of America), además, del IEEE ( Institute of Electrical and Electronics Engineers) o la “Web of knowledge” entre otras. Además de realizar la búsqueda en estas fuentes, se ha optado por vías de información más comunes como Google Académico o el portal de acceso “Ingenio” a los todos los recursos electrónicos contenidos en la base de datos de la universidad. El estudio genera una ampliación en el conocimiento de la labor práctica de las HRTF. La mayoría de los estudios enfocan sus esfuerzos en mejorar la percepción del evento sonoro mediante su simulación en la escucha estéreo o multicanal. A partir de las HRTF, esto es posible mediante el análisis y el cálculo de datos como pueden ser las regresiones, siendo éstas muy útiles en la predicción de una medida basándose en la información de la actual. Otro campo de especial interés es el de la generación de sonido 3D. Mediante la base de datos HRTF es posible la simulación de una señal biaural. Se han diseñado algoritmos que son implementados en dispositivos DSP, de tal manera que por medio de retardos interaurales y de diferencias espectrales es posible llegar a un resultado óptimo de sonido envolvente, sin olvidar la importancia de los efectos de reverberación para conseguir un efecto creíble de sonido envolvente. Debido a la complejidad computacional que esto requiere, gran parte de los estudios coinciden en desarrollar sistemas más eficientes, llegando a objetivos tales como la generación de sonido 3D en tiempo real. ABSTRACT. This project involves the creation of a Graphic User Interface (GUI) in the Matlab environment which creates a graphic representation of the HRTF (Head-Related Transfer Function) database. The head transfer function is a very useful tool in the study of the capacity of human beings to perceive their sound environment, as well as their ability to localise sound sources in the area surrounding them. The binaural HRTF (terminology which refers to the HRTF group of the left and right ear) in itself possesses information of special interest seeing that the differences between the HRTF of each ear admits the information that our system of hearing uses in the perception of each sound field. For this reason, the functionality of the graphic interface created presents great benefits within the study of this field. The interaural differences are characterised in space and in time, varying depending on the frequency. By means of Fourier's transformed inverse of the HRTF signal, the response to the head impulse is obtained, in other words, the HRIR (Head-Related Impulse Response). This, as well as having a great use in the creation of software or surround sound generating devices, is used to obtain ITD differences (Interaural Time Difference) and ILD (Interaural Time Difference), commonly named “spatial localisation parameters”. The HRTF database contains the binaural information of different points of sound source location, forming a network of spherical coordinates which surround the subject's head. This network, according to the measures carried out in the anechoic chamber at the EUITT (School of Telecommunications Engineering) gives a precision in elevation of 10º and in azimuth of 5º. The receivers are two microphones placed on the acoustic mannequin called HATS (Hats and Torso Simulator) Brüel&Kjaer model 4100D. This has the physical characteristics which affect the perception of the surroundings which are the forms of the auricle (pinna), the head, neck and human torso. It will be necessary to make interpolation calculations for all those points which are not contained the HRTF database. This process is extremely important not only to strengthen the database's capacity but also for its usefulness in making comparisons with other databases that exist in the study of this field. The graphic user interface is conceived for a simple, clear and predictable use which is also interactive. Since the first outline of the program, its philosophy has been clear, based on the needs of a user who requires a practical tool with an intuitive use. Its design with only one window unites not only the components which obtain data but also those which make the graphic representation of the HRTFs possible, the hrir and the ITD and ILD spatial location parameters. The user will be able to alternate the graphic representations at the same time as entering the point coordinates that they wish to display, defined by phi (elevation) and theta (azimuth). The facet of the interface is what provides the great ease of access and reading of the information displayed on it. In addition, the user can enter values included in the database or values which are intermediate to these. It is, likewise, indicated to the interface the need to carry out the interpolation of these values. The interpolation method is the deliberation of the inverse distance between points. Depending on the values entered by the user, an interpolation of two or four points will be carried out, with these being adjacent to the entered value, whether that is phi or theta. To add versatility to the graphic user interface, the option of generating output files in the form of an image of the graphics displayed has been added. This is so that the user may extract the information that interests them for any phi and theta value. This final project is completed with a research and comparative study essay on the function and application of HRTF databases within the scientific and research framework. It has been possible to collate related information by means of scientific research magazines such as the JAES (Journal of the Audio Engineering Society), the ASA (Acoustical Society of America) as well as the IEEE (Institute of Electrical and Electronics Engineers) and the “Web of knowledge” amongst others. In addition to carrying out research with these sources, I also opted to use more common sources of information such as Academic Google and the “Ingenio” point of entry to all the electronic resources contained on the university databases. The study generates an expansion in the knowledge of the practical work of the HRTF. The majority of studies focus their efforts on improving the perception of the sound event by means of its simulation in stereo or multichannel listening. With the HRTFs, this is possible by means of analysis and calculation of data as can be the regressions. These are very useful in the prediction of a measure being based on the current information. Another field of special interest is that of the generation of 3D sound. Through HRTF databases it is possible to simulate the binaural signal. Algorithms have been designed which are implemented in DSP devices, in such a way that by means of interaural delays and wavelength differences it is possible to achieve an excellent result of surround sound, without forgetting the importance of the effects of reverberation to achieve a believable effect of surround sound. Due to the computational complexity that this requires, a great many studies agree on the development of more efficient systems which achieve objectives such as the generation of 3D sound in real time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La cámara Kinect está desarrollada por Prime Sense en colaboración con Microsoft para la consola XBox, ofrece imágenes de profundidad gracias a un sensor infrarrojo. Este dispositivo también incluye una cámara RGB que ofrece imágenes a color además de una serie de micrófonos colocados de tal manera que son capaces de saber de qué ángulo proviene el sonido. En un principio Kinect se creó para el ocio doméstico pero su bajo precio (en comparación con otras cámaras de iguales características) y la aceptación por parte de desarrolladores han explotado sus posibilidades. El objetivo de este proyecto es, partiendo de estos datos, la obtención de variables cinemáticas tales como posición, velocidad y aceleración de determinados puntos de control del cuerpo de un individuo como pueden ser el cabeza, cuello, hombros, codos, muñecas, caderas, rodillas y tobillos a partir de los cuales poder extraer patrones de movimiento. Para ello se necesita un middleware mediante el entorno de libre distribución (GNU) multiplataforma. Como IDE se ha utilizado Processing, un entorno open source creado para proyectos de diseño. Además se ha utilizado el contenedor SimpleOpenNI, desarrollado por estudiantes e investigadores que trabajan con Kinect. Esto ofrece la posibilidad de prescindir del SDK de Microsoft, el cual es propietario y obliga a utilizar su sistema operativo, Windows. Usando estas herramientas se consigue una solución viable para varios sistemas operativos. Se han utilizado métodos y facilidades que ofrece el lenguaje orientado a objetos Java (Proccesing hereda de este), y se ha planteado una solución basada en un modelo cliente servidor que dota de escalabilidad al proyecto. El resultado del proyecto es útil en aplicaciones para poblaciones con riesgo de exclusión (como es el espectro autista), en telediagnóstico, y en general entornos donde se necesite estudiar hábitos y comportamientos a partir del movimiento humano. Con este proyecto se busca tener una continuidad mediante otras aplicaciones que analicen los datos ofrecidos. ABSTRACT. The Kinect camera is developed by PrimeSense in collaboration with Microsoft for the xBox console provides depth images thanks to an infrared sensor. This device also includes an RGB camera that provides color images in addition to a number of microphones placed such that they are able to know what angle the sound comes. Kinect initially created for domestic leisure but its low prices (compared to other cameras with the same characteristics) and acceptance by developers have exploited its possibilities. The objective of this project is based on this data to obtain kinematic variables such as position, velocity and acceleration of certain control points of the body of an individual from which to extract movement patterns. These points can be the head, neck, shoulders, elbows, wrists, hips, knees and ankles. This requires a middleware using freely distributed environment (GNU) platform. Processing has been used as a development environment, and open source environment created for design projects. Besides the container SimpleOpenNi has been used, it developed by students and researchers working with Kinect. This offers the possibility to dispense with the Microsoft SDK which owns and agrees to use its operating system, Windows. Using these tools will get a viable solution for multiple operating systems. We used methods and facilities of the Java object-oriented language (Processing inherits from this) and has proposed a solution based on a client-server model which provides scalability to the project. The result of the project is useful in applications to populations at risk of exclusion (such as autistic spectrum), in remote diagnostic, and in general environments that need study habits and behaviors from human motion. This project aims to have continuity using other applications to analyze the data provided.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

"The first six volumes of this work recorded the progress of Surgery down to 1913. Then came the Great War ... Hence, immediately after the Armistice ... I began to assemble a full staff of experts, whose work appears in Volumes VII and VIII."--Preface, v.7, 1921.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Solar keratoses (SKs) are among the strongest determinants of skin cancer, but little is known about the success of measures to control these common skin tumors. Objective: To determine whether daily sunscreen application and/or beta carotene supplementation retards the rate of occurrence of SKs in adults in the medium term. Design: Randomized controlled trial conducted between February 1992 and August 1996. Setting: General community of the subtropical township of Nambour, Australia (latitude, 26degrees south). Participants: A total of 1621 adults aged 25 to 74 years. Interventions: Participants were randomized to daily use of sunscreen (application of a high-protection sunscreen to their head, neck, arms, and hands every morning) or application of sunscreen at their usual discretionary rate. They were also randomly assigned to take either one 30-mg tablet of beta carotene or one placebo tablet each day. Main Outcome Measure: Change in the prevalent number of SKs in the intervention group relative to change in the control group. Results: The ratio of SK counts in 1994 relative to 1992 was lower in people randomized to daily sunscreen use (1.20; 95% confidence interval, 1.04-1.39) than in those randomized to discretionary sunscreen use (1.57; 95% confidence interval, 1.35-1.84). This 24% reduction is equivalent to the prevention of an average of I additional SK per person over that time. A reduction in the rate of change of SK prevalence was also seen in the sunscreen intervention group relative to the discretionary sunscreen group between 1994 and 1996, but it was not significant. No effect on the rate of change of prevalent SK counts was seen among those taking beta carotene supplements relative. to those taking placebo tablets. Conclusions: Daily application of sunscreen retarded the rate of SK acquisition among adults in a subtropical environment, while a beta carotene supplementation of 30 mg/d had no influence on the occurrence of SKs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aims: The aim of this study was to quantify the relationship between acute alcohol consumption and injury type (nature of injury, body region injured), while adjusting for the effect of known confounders (i.e. demographic and situational variables, usual drinking patterns, substance use and risk-taking behaviour). Methods: A cross-sectional study was conducted between October, 2000 and October, 2001 of patients aged >= 15 years presenting to a Queensland Emergency Department for treatment of an injury sustained in the preceding 24 h. There were three measures of acute alcohol consumption: drinking setting, quantity, and beverage type consumed in the 6 h prior to injury. Two variables were used to quantify injury type: nature of injury (fracture/dislocation, superficial, internal, and CNS injury) and body part injured (head/neck, facial, chest, abdominal, external, and extremities). Both were derived from patient medical records. Results: Five hundred and ninety three patients were interviewed. Logistic regression analyses indicated that, after controlling for relevant confounding variables, there was no significant association between any of the three measures of acute alcohol consumption and injury type. Conclusions: The effects of acute alcohol consumption are not specific to injury type. Interventions aimed at reducing the incidence of alcohol-related injury should not be targeted at specific injury types.