Uma das principais limitações relacionadas ao processo de retificação de cerâmica é a confiabilidade do material devido aos defeitos introduzidos no processamento. A compreensão dos mecanismos envolvidos na remoção de material durante a retificação e a interação com os parâmetros de processo e microestrutura é fundamental para minimizar estes defeitos. A proposta desta revisão é apresentar os modelos de remoção de material e a forma como afetam as propriedades mecânicas da peça final.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: This study evaluated the efficacy of the union between two new self-etching self-adhesive resin cements and enamel using the microtensile bond strength test.Materials and Methods: Buccal enamel of 80 bovine teeth was submitted to finishing and polishing with metallographic paper to a refinement of #600, in order to obtain a 5-mm(2) flat area. Blocks (2 x 4 x 4 mm) of laboratory composite resin were cemented to enamel according to different protocols: (1) untreated enamel + RelyX Unicem cement (RX group); (2) untreated enamel + Bifix SE cement (BF group); (3) enamel acid etching and application of resin adhesive Single Bond + RelyX Unicem (RXA group); (4) enamel acid etching and application of resin adhesive Solobond M + Bifix SE (BFA group). After 7 days of storage in distillated water at 37 degrees C, the blocks were sectioned for obtaining microbar specimens with an adhesive area of 1 mm(2) (n = 120). Specimens were submitted to the microtensile bond strength test at a crosshead speed of 0.5 mm/min. The results (in MPa) were analyzed statistically by ANOVA and Tu key's test.Results: Enamel pre-treatment with phosphoric acid and resin adhesive (27.9 and 30.3 for RXA and BFA groups) significantly improved (p <= 0.05) the adhesion of both cements to enamel compared to the union achieved with as-polished enamel (9.9 and 6.0 for RX and BF).Conclusion: Enamel pre-treatment with acid etching and the application of resin adhesive significantly improved the bond efficacy of both luting agents compared to the union achieved with as-polished enamel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14 mol L-1 HNO3, 0.1% (v/v) Triton X-100 and 0.1% (v/v) water soluble tertiary amines (CFA-C, pH 8). The limits of detection (LOD), limits of quantification (LOQ), and characteristic masses obtained were 0.28, 0.95 mu g L-1 and 35 pg (LHGA) and 0.34, 1.13 mu g L-1 and 78 pg (THGA), respectively. The accuracy of the analytical results obtained by the proposed procedure in both equipments was confirmed by a paired t-test at the 95% confidence level and compared with a conventional procedure based on acid digestion. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since the use of air abrasion has grown in pediatric dentistry, the aim of this study was to evaluate, by means of shear bond strength testing, the need to use the total etching technique or self-etching primers on dentin of primary teeth after air abrasion. Twenty-five exfoliated primary molars had their occlusal dentin exposed by trimming and polishing. Specimens were treated by: Air abrasion + Scotchbond MultiPurpose adhesive (G1); 37% phosphoric acid + Scotchbond MP adhesive (G2); Clearfil SE (G3); Air abrasion ( 37% phosphoric acid + Scotchbond MP adhesive (G4); Air abrasion + Clearfil SE (G5). On the treated surface, a cylinder of 2 mm by 6 mm was made using a composite resin (Z100). Duncan's test showed that: (G2 = G3 = G5) > (G1 = G4). The use of a selfetching primer on air abraded dentin is recommended to obtain higher bond strengths.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of surface glazing and polishing of yttrium-stabilized tetragonal zirconia polycrystal ceramic on early dental biofilm formation, as well as the effect of brushing on the removal of adhered bacteria. Two subjects used oral appliances with polished and glazed samples fixed to the right and left sides. After 20 minutes, 1 hour, and 6 hours, the subjects manually brushed the samples on the right side. The samples were analyzed using scanning electron microscopy. Granular material was verified on the samples, especially on irregular surfaces. After 1 hour, there was no significant difference between glazed and polished surfaces in terms of bacterial presence. However, glazed surfaces tended to accumulate more biofilm, and brushing did not completely remove the biofilm. Polished surfaces seem to present a lower tendency for biofilm formation. Int J Prosthodont 2007;20:419-422.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper discusses the investigation of an abrasive process for finishing flat workpieces, based on the combination of important grinding and lapping characteristics. Instead of loose abrasive grains between the workpiece and the lapping plate, a resinoid grinding wheel of hot-pressed silicon carbide is placed on the plate of a device resembling a lapping machine. The resin bond grinding wheel is dressed with a single-point diamond. In addition to keeping the plate flat, dressing also plays the role of interfering in the behavior of the process by varying the overlap factor (Ud). It was found that the studied process simplify the set-up and can be controlled more easily than in lapping, whose is a painstaking process. The surface roughness and flatness deviation proved comparable to those of lapping, or even finer than it, with the additional advantage of a less contaminated workpiece surface with a shiny appearance. The process was also monitored by acoustic emission (AE), which indicates to be a promissing and suitable technique for use in this process. Copyright © 2008 by ASME.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To study the influence of color opacity and light-curing systems (halogen light vs blue LED) on the microhardness of a composite resin. Methods: Esthet-X composite resin (Dentsply), shades A2 and A2-O, was inserted in a stainless steel matrix (5 mm diameter and 2 mm deep) and was light cured for 40 seconds with a halogen light source (XL 3000; 3M/ESPE) or a blue LED (Optilight LD II; Gnatus). Eight groups of 15 specimens each were formed, and were further divided according to the light-curing systems, the exposed area (base and surface), and the opacity of the composite resin, producing 120 specimens. The specimens were next stored in distilled water for 24 hours, embedded in a chemically activated acrylic resin, then subjected to finishing and polishing with sandpaper and felt discs. Microhardness was measured with a Vickers Digital Microhardness meter, with a 50 g load for 30 seconds. The obtained microhardness means were analyzed by ANOVA and Tukey's multiple-comparison test at 5% significance level. Results: The surface microhardness was always greater than the base microhardness, regardless of the light-curing source. The halogen light lamp produced significantly higher composite resin microhardness means than the blue LED (57.61 vs. 42.53 HV) (p<0.05). Statistically significant differences (p<0.05) were obtained between the microhardness means for the different composite opacities; lowest microhardness in depth was produced by the A2-O shade. Conclusion: Composite resin opacity as well as the light-curing system influenced the microhardness of the material.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: An appropriate selection of instruments is essential to perform a correct debonding technique, by properly removing orthodontic brackets and the remaining resin. Objective: The aim of this study was to evaluate three methods of remaining resin removal on enamel surface after bracket debonding, by means of Scanning Electron Microscopy (SEM). Methods: Eighteen bovine incisors were selected and divided into three groups (A, B and C) of six teeth each. Before bracket bonding, epoxy resin casts were obtained by impression of the teeth with addition silicon, in order to register baseline enamel characteristics and representing the control group. The methods for remaining resin removal were: Group A - gross and medium granulation Soflex discs; Group B - carbide bur in low-speed; Group C - carbide bur in high-speed. Soflex polishing system fine and ultrafine granulation discs were used for Group A, rubber tips for Groups B and C, and polishing paste for all groups. After polishing, impression of teeth were taken and casts were analyzed by means of SEM. The baseline enamel characteristics (Control Group) were compared to the final aspect of enamel to determine the method that generated less enamel abrasion. Results and Conclusion: The remaining resin removal by carbide bur in low-rotation, and enamel polished with rubber tips followed by polishing paste produced the smaller damage to the enamel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Payload and high-tech are important characteristics when the goals are aerospace applications. The development of the technologies associated to these applications has interests that transcend national boundaries and are of strategic importance to the nations. Ultra lightweight mirrors, supports and structures for optical systems are important part of this subject. This paper reports the development of SiC substrates, obtained by pressing, to be applied on embedded precision reflective optics. Different SiC granulometries, having YAG as sintering additive, were processed by: ball milling, drying and deagglomeration, sift, uniaxial and isostatic pressing, and, finally, argon atmosphere sintering at 1900°C. Different porosities were obtained according to the amount of organic material added. Into one side of the samples pellets of organic material were introduced to generate voids to reduce the weight of samples as a whole. The substrates were grinding and polished, looking for a SiC surface having low porosity, as porosity is directly related to light scattering that should be avoided on optical surfaces. Laser surface treatments were applied (using or not SiC barbotine) as a method to improve the surface quality. The samples were characterized by optical and laser confocal microscopy, roughness measurements and mechanical tests. The results are very promissory for future applications. © 2012 Materials Research Society.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)