981 resultados para Greenhouse gas fluxes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Personal greenhouse gas calculators (PGGC) are important tools to raise awareness of the impact of personal behaviour on carbon dioxide emissions. Per capita, Australians are the highest emitters of greenhouse gases in the world and the task for them to reduce emissions to sustainable levels will be particularly challenging. This paper reviews six PGGC promoted in Australia and evaluates them for their consistency. The emissions for an individual currently practicing a modest green lifestyle are calculated and compared. Emission calculations were found to differ by an order of magnitude in some cases. It was also found that users of PGGC are not adequately informed about the limitations of the calculators. The adoption of modest and radical green lifestyles reduced greenhouse gas emissions to 83% and 53% of the average Australian, indicating that behavioural changes by consumers alone will be insufficient to reduce emissions to sustainable levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC), the construction sector has the greatest potential for climate change mitigation. This work investigates the potential for climate change mitigation in naturally ventilated and mixed mode office buildings, by evaluating the range of influence of building design and occupants on greenhouse gas emissions as well as thermal and visual comfort.

Thermal comfort is evaluated according to the EN 15251 adaptive thermal comfort model, visual comfort is based on daylight autonomy and view. Parametric studies have been conducted based on building simulation for the climate of Athens, Greece. Input data are based on a literature review, and on results from a field study conducted among office occupants and architects in Athens.

The results show that the influence of occupants on greenhouse gas emissions is larger than the influence of building design. Energy saving office equipment, as well as active use of building controls for shading and lighting by occupants are crucial parameters regarding the reduction of CO2 emissions. In mixed mode buildings, the coefficient of performance of the cooling system is an important parameter as well. Regarding thermal and visual comfort, the influence of building design is predominant. A green building, well protected against heat from the sun and able to balance solar and internal heat gains, provides higher comfort levels and is less affected by the influence of occupants. In mixed mode buildings, building design is the predominant influence on the magnitude of cooling loads. A hot summer including heat waves can significantly reduce thermal comfort and increase the resulting greenhouse gas emissions. Green buildings are least affected by these influences.

The EN 15251 adaptive thermal comfort model provides a thermal comfort evaluation method valid throughout Europe. However, for the Mediterranean climate of Athens, Greece, most of the configurations investigated within this study do not meet the requirements according to this model. EN 15251 refers to an adaptive thermal comfort model for naturally ventilated and to a static model for mechanically ventilated buildings. For mixed mode buildings, the static model is recommended, but literature indicates that occupants in those buildings might be more tolerant towards higher temperatures. The hypothetical application of the EN 15251 adaptive thermal comfort model in mixed mode offices, as investigated in this study, shows potential for greenhouse gas emission savings. However, this influence is small compared to that of building design and occupants. Conclusions are drawn regarding the categorisation and exceeding criteria according to EN 15251 adaptive thermal comfort model for offices in a Mediterranean climate.

The results of this work show, that not only green buildings, but also green occupants can significantly contribute to the mitigation of the climate change. Mechanisms of the real estate market as well as the lifestyle of occupants are important influences in this context. Sustainability therefore refers to finding the right balance between occupant’s comfort expectations and resulting greenhouse gas emissions for a specific building, rather than optimisation of single parameters

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a holistic approach to comfort and greenhouse gas emissions in mixed mode offices. It is based on parametric studies for a typical cellular office in the Mediterranean climate of Athens, Greece, using building simulation.

Considered parameters are the influence of different building design, varying occupant behaviour and internal heat loads, as well as of an exceptionally hot summer. Additionally, the performance of a cooling strategy following the comfort limits according to the EN 15251 adaptive model is compared with the common fixed cooling set point 22°C.

The performance of mixed mode offices is evaluated regarding thermal comfort, daylight autonomy and related greenhouse gas emissions. Results indicate strategies to improve sustainability in mixed mode offices in Athens, by balancing the influencing parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

According to the Intergovernmental Panel on Climate Change the buildings sector has the largest mitigation potential for CO2 emissions. Especially in office buildings, where internal heat loads and a relatively high occupant density occur at the same time with solar heat gains, overheating has become a common problem. In Europe the adaptive thermal comfort model according to EN 15251 provides a method to evaluate thermal comfort in naturally ventilated buildings. However, especially in the context of the climate change and the occurrence of heat waves within the last decade, the question arises, how thermal comfort can be maintained without additional cooling, especially in warm climates. In this paper a parametric study for a typical cellular naturally ventilated office room has been conducted, using the building simulation software EnergyPlus. It is based on the Mediterranean climate of Athens, Greece. Adaptive thermal comfort is evaluated according to EN 15251. Variations refer to different building design priorities, and they consider the variability of occupant behaviour and internal heat loads by using an ideal and worst case scenario. The influence of heat waves is considered by comparing measured temperatures for an average and an exceptionally hot year within the last decade. Since the use of building controls for shading affects thermal as well as visual comfort, daylighting and view are evaluated as well. Conclusions are drawn regarding the influence and interaction of building design, occupants and heat waves on comfort and greenhouse gas emissions in naturally ventilated offices, and related optimisation potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many cities around the world are looking for ways to reduce their per capita greenhouse gas emissions. The outward growth of cities from a central business district, typical of many cities around the world, is often seen as working against this goal and as unsustainable. This is especially the case in circumstances where this growth is not supported by the necessary infrastructure, often resulting in an increase in the use of private transport. However, alternative scenarios to contain the outward growth are being proposed. This paper provides a comparison of the energy demand and greenhouse gas emissions between typical detached outer-suburban housing currently being built in Australia's major cities and inner-city and -suburban apartments, which are increasingly seen as a legitimate alternative to the housing that is currently being built on our outer city fringes. By analysing the energy demand associated with the construction and operation of each housing type and for occupant travel it was found that the location of the housing and its size are the dominant factors determining energy use and greenhouse gas emissions. The findings from this analysis provide useful information for policy-makers in planning the development of our cities into the future, when faced with a growing population and an increasing need to minimise greenhouse gas emissions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Borough of Queenscliffe has identified the importance of reducing its greenhouse gas emissions and aims to become a carbon zero municipality by 2020. For a house, suburb or town to become carbon neutral ideally it produces an equivalent amount of energy from renewable resources to that which it consumes. By increasing the number of solar systems, both photovoltaic (PV) and hot water, in the residential sector, greenhouse gas emissions will be reduced. The number of solar systems located in the Borough of Queenscliffe has been estimated and a database of these systems has been created, including the size and panel orientation. The energy generated by each solar system, in addition to the reductions in greenhouse gas emissions, has been calculated for an average year.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to investigate the factors driving greenhouse gas reporting by Chinese companies.
Design/methodology/approach – Content analysis of annual reports and corporate social responsibility (CSR) reports for the year 2010 of the top 100 A-share companies listed on Shanghai Stock Exchange was conducted to investigate the extent of greenhouse gas reporting. Multiple regression analysis was performed to determine the factors driving these companies’ greenhouse gas reporting.
Findings – It was found that most Chinese companies reported neutral and good news. The results also indicate larger companies operating in an industry which has higher level of carbon dioxide emissions tend to have higher levels of greenhouse gas disclosures, consistent with the expectation of legitimacy theory. However, profitability and overseas listing were not significantly related to greenhouse gas reporting. This is consistent with the findings of previous literature. Finally, contrary to expectations, state-owned companies report less greenhouse gas information than private companies.
Originality/value – The paper contributes towards theory development by testing legitimacy theory in the context of greenhouse gas reporting by Chinese companies and contributes to existing literature on greenhouse gas reporting by focussing on the large emerging economy of China. The practical contribution of the paper rests in the area of accounting practice. The results outline the dearth in greenhouse gas reporting by Chinese companies, suggesting there needs to be future development of accounting standards in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most of water distribution systems (WDS) need rehabilitation due to aging infrastructure leading to decreasing capacity, increasing leakage and consequently low performance of the WDS. However an appropriate strategy including location and time of pipeline rehabilitation in a WDS with respect to a limited budget is the main challenge which has been addressed frequently by researchers and practitioners. On the other hand, selection of appropriate rehabilitation technique and material types is another main issue which has yet to address properly. The latter can affect the environmental impacts of a rehabilitation strategy meeting the challenges of global warming mitigation and consequent climate change. This paper presents a multi-objective optimization model for rehabilitation strategy in WDS addressing the abovementioned criteria mainly focused on greenhouse gas (GHG) emissions either directly from fossil fuel and electricity or indirectly from embodied energy of materials. Thus, the objective functions are to minimise: (1) the total cost of rehabilitation including capital and operational costs; (2) the leakage amount; (3) GHG emissions. The Pareto optimal front containing optimal solutions is determined using Non-dominated Sorting Genetic Algorithm NSGA-II. Decision variables in this optimisation problem are classified into a number of groups as: (1) percentage proportion of each rehabilitation technique each year; (2) material types of new pipeline for rehabilitation each year. Rehabilitation techniques used here includes replacement, rehabilitation and lining, cleaning, pipe duplication. The developed model is demonstrated through its application to a Mahalat WDS located in central part of Iran. The rehabilitation strategy is analysed for a 40 year planning horizon. A number of conventional techniques for selecting pipes for rehabilitation are analysed in this study. The results show that the optimal rehabilitation strategy considering GHG emissions is able to successfully save the total expenses, efficiently decrease the leakage amount from the WDS whilst meeting environmental criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Video feito pela WWV