969 resultados para Graft copolymers.
Resumo:
By expressing an array of pattern recognition receptors (PRRs), fibroblasts play an important role in stimulating and modulating the response of the innate immune system. The TLR3 ligand polyriboinosinic acid-polyribocytidylic acid, poly(I:C), a mimic of viral dsRNA, is a vaccine adjuvant candidate to activate professional antigen presenting cells (APCs). However, owing to its ligation with extracellular TLR3 on fibroblasts, subcutaneously administered poly(I:C) bears danger towards autoimmunity. It is thus in the interest of its clinical safety to deliver poly(I:C) in such a way that its activation of professional APCs is as efficacious as possible, whereas its interference with non-immune cells such as fibroblasts is controlled or even avoided. Complementary to our previous work with monocyte-derived dendritic cells (MoDCs), here we sought to control the delivery of poly(I:C) surface-assembled on microspheres to human foreskin fibroblasts (HFFs). Negatively charged polystyrene (PS) microspheres were equipped with a poly(ethylene glycol) (PEG) corona through electrostatically driven coatings with a series of polycationic poly(L-lysine)-graft-poly(ethylene glycol) copolymers, PLL-g-PEG, of varying grafting ratios g from 2.2 up to 22.7. Stable surface assembly of poly(I:C) was achieved by incubation of polymer-coated microspheres with aqueous poly(I:C) solutions. Notably, recognition of both surface-assembled and free poly(I:C) by extracellular TLR3 on HFFs halted their phagocytic activity. Ligation of surface-assembled poly(I:C) with extracellular TLR3 on HFFs could be controlled by tuning the grafting ratio g and thus the chain density of the PEG corona. When assembled on PLL-5.7-PEG-coated microspheres, poly(I:C) was blocked from triggering class I MHC molecule expression on HFFs. Secretion of interleukin (IL)-6 by HFFs after exposure to surface-assembled poly(I:C) was distinctly lower as compared to free poly(I:C). Overall, surface assembly of poly(I:C) may have potential to contribute to the clinical safety of this vaccine adjuvant candidate.
Resumo:
BACKGROUND & AIMS: Recent studies have described a major impact of genetic variations near the IL28B gene on the natural course and outcome of antiviral therapy in chronic hepatitis C. We therefore, aimed to explore the impact of donor and recipient genotypes of these polymorphisms on hepatitis C virus (HCV) liver graft reinfection. METHODS: Donor and recipient genotypes of IL28B rs12979860C>T single nucleotide polymorphism were determined in 91 patients with HCV liver graft reinfection, 47 of whom were treated with pegylated interferon-α (PEG-IFN-α) and ribavirin. IL28B genetic polymorphisms were correlated with the natural course and treatment outcome of recurrent hepatitis C. RESULTS: Patients requiring liver transplantation due to end-stage chronic hepatitis C appeared to be selected toward the adverse genotypes rs12979860 CT/TT compared to non-transplanted HCV-infected patients (p=0.046). Patients with the donor genotype rs12979860 CC had higher peak ALT and HCV RNA serum concentrations than those with CT/TT (p=0.04 and 0.06, respectively). No association was observed between ALT/HCV RNA serum concentrations and recipient genotypes (p>0.3). More important, donor IL28B rs12979860 CC vs. CT/TT genotypes were associated with rapid, complete early, and sustained virologic response (RVR, cEVR, SVR) to treatment with PEG-IFN-α and ribavirin (p=0.003, 0.0012, 0.008, respectively), but weaker associations of recipient genotypes with RVR, cEVR, and SVR were observed as well (p=0.0046, 0.115, 0.118, respectively). CONCLUSIONS: We provide evidence for a dominant, but not exclusive impact of the donor rather than the recipient IL28B genetic background on the natural course and treatment outcome of HCV liver graft reinfection.
Resumo:
Extracranial carotid aneurysm is a rare vascular manifestation of Behçet disease. To our knowledge, only 32 cases have been reported. This article presents a complex case of a 28-year-old man who was first treated by vein graft reconstruction. At 12 months of follow-up, a nonanastomotic false aneurysm of the vein graft occurred and was treated by interposition of prosthetic graft. Two months later, an anastomotic pseudoaneurysm between the two grafts was excluded by two stent grafts. Based on our experience and a review of the literature, we compared the outcomes of prosthetic and autologous vein reconstructions and discussed the role of carotid ligation and immunosuppressive treatment.
Resumo:
OBJECTIVE: An operative technique is described as a salvage treatment for severe subglottic and supraglottic laryngeal stenosis. In addition to expansion of the laryngeal framework with an anterior cartilage graft, as used in a classical laryngotracheal reconstruction, the scar tissue obliterating the airway lumen is excised and a mucosal graft is placed to reconstruct the inner lining of the airway. The graft is harvested from buccal mucosa. METHODS: The operative technique is outlined. Three cases, 2 paediatric and one adult, with complete or near complete laryngeal stenosis are presented where this operative technique was employed. In all patients several surgeries had been performed previously which were unsuccessful. RESULTS: In all 3 patients a patent airway was achieved with decannulation of the tracheostomy in the 2 paediatric patients. CONCLUSIONS: In patients with severe subglottic or supraglottic airway stenosis where other surgeries have failed, excision of endoluminal scar tissue and placement of a buccal mucosal graft, in addition to conventional laryngotracheal reconstruction, is a promising technique. In revision cases of subglottic stenosis cricotracheal resection might not be an option because of scarring from previous surgeries. This operation is an alternative, which allows an increase in the airway lumen by excising the scar tissue then re-lining the exposed internal lumen. The buccal mucosa reduces granulation formation and re-stenosis.
Resumo:
BACKGROUND: Recurrent hepatitis C virus infection after liver transplantation is associated with reduced graft and patient survival. Re-transplantation for graft failure due to recurrent hepatitis C is controversial and not performed in all centers. CASE PRESENTATION: We describe a 54-year-old patient with hepatitis C virus genotype 1b infection and a null response to pegylated interferon-α and ribavirin who developed decompensated graft cirrhosis 6 years after a first liver transplantation. Treatment with sofosbuvir and ribavirin allowed for rapid negativation of serum HCV RNA and was well tolerated despite advanced liver and moderate renal dysfunction. Therapeutic drug monitoring did not reveal any clinically significant drug-drug interactions. Despite virological response, the patient remained severely decompensated and re-transplantation was performed after 46 days of undetectable serum HCV RNA. The patient is doing well 12 months after his second liver transplantation and remains free of hepatitis C virus. CONCLUSIONS: The use of directly acting antivirals may allow for successful liver re-transplantation for recipients who remain decompensated despite virological response and is likely to improve the outcome of liver re-transplantation for end-stage recurrent hepatitis C.
Resumo:
OBJECTIVE: The primary end points of this study were safety and efficacy of early cannulation of the Flixene graft (Maquet-Atrium Medical, Hudson, NH). Secondary end points were complications and patency. METHODS: This is a prospective single-center nonrandomized study. Study data included patient characteristics; history of vascular access; operative technique; interval between implantation and initial cannulation; complications; and patency at 1 month, 3 months, and every 6 months. Patency rates were estimated by the Kaplan-Meier method. RESULTS: Between January 2011 and September 2013, a total of 46 Flixene grafts were implanted in 44 patients (27 men) with a mean age of 63 years. The implantation site was the upper arm in 67% of cases, the forearm in 11%, and the thigh in 22%. Seven grafts were never cannulated during the study period. Of the remaining 39 grafts, 32 (82%) were successfully cannulated within the first week after implantation, including 16 (41%) on the first day. The median interval from implantation to initial cannulation was 2 days (interquartile range, 1-3 days). The median follow-up was 223.5 days (interquartile range, 97-600 days). Five hematomas occurred, but only one required surgical revision. Primary assisted and secondary patency rates were 65% and 86%, respectively, at 6 months and 56% and 86%, respectively, at 1 year. CONCLUSIONS: This study suggests that cannulation of the Flixene graft within 1 week after implantation is safe and effective. Early cannulation avoids or shortens the need for a temporary catheter. One-year patency rates appeared to be comparable to those achieved with conventional grafts, but long-term follow-up and randomized controlled studies will be needed to confirm this finding.
Improving coronary artery bypass graft durability: use of the external saphenous vein graft support.
Resumo:
Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.
Resumo:
Chronic graft-versus-host disease (cGvHD) is the leading cause of late nonrelapse mortality (transplant-related mortality) after hematopoietic stem cell transplant. Given that there are a wide range of treatment options for cGvHD, assessment of the associated costs and efficacy can help clinicians and health care providers allocate health care resources more efficiently. OBJECTIVE: The purpose of this study was to assess the cost-effectiveness of extracorporeal photopheresis (ECP) compared with rituximab (Rmb) and with imatinib (Imt) in patients with cGvHD at 5 years from the perspective of the Spanish National Health System. METHODS: The model assessed the incremental cost-effectiveness/utility ratio of ECP versus Rmb or Imt for 1000 hypothetical patients by using microsimulation cost-effectiveness techniques. Model probabilities were obtained from the literature. Treatment pathways and adverse events were evaluated taking clinical opinion and published reports into consideration. Local data on costs (2010 Euros) and health care resources utilization were validated by the clinical authors. Probabilistic sensitivity analyses were used to assess the robustness of the model. RESULTS: The greater efficacy of ECP resulted in a gain of 0.011 to 0.024 quality-adjusted life-year in the first year and 0.062 to 0.094 at year 5 compared with Rmb or Imt. The results showed that the higher acquisition cost of ECP versus Imt was compensated for at 9 months by greater efficacy; this higher cost was partially compensated for ( 517) by year 5 versus Rmb. After 9 months, ECP was dominant (cheaper and more effective) compared with Imt. The incremental cost-effectiveness ratio of ECP versus Rmb was 29,646 per life-year gained and 24,442 per quality-adjusted life-year gained at year 2.5. Probabilistic sensitivity analysis confirmed the results. The main study limitation was that to assess relative treatment effects, only small studies were available for indirect comparison. CONCLUSION: ECP as a third-line therapy for cGvHD is a more cost-effective strategy than Rmb or Imt.
Resumo:
Oral implantology is a common procedure in dentistry, especially for fully or partially edentulous patients. The implants must be placed in the best location from both the aesthetic and functional point of view. Because of this it is increasingly more frequent to resort to regeneration techniques that use substitutes of the bone itself, in order to be able to insert the implants in the most appropriate location. Material and Methodology: A review was performed on the literature from the last ten years based on the following search limitations: "graft materials', 'allograft', 'xenograft', 'autologous graft" and 'dentistry". Results: 241 works were obtained that after reading their respective summaries, they were reduced to 38, and 9 previous works were included in order to summarize the concepts. Discussion: Autologous grafts are the 'gold standard' of the bone regeneration. They have obvious advantages, but they also have drawbacks. This is why allogeneic and xenogeneic tissues are used. The former because of their clear similarity with the recipient's tissue and the latter due to their wide availability. Given that these grafts also have drawbacks, the industry has developed synthetic materials that have properties similar to those of human bone tissue. However, as of today, the ideal material to substitute human bone has not yet been found. In recent years the tendency has been to combine these synthetic materials with the patient's own bone, which is extracted during drilling in implant placement, with bone marrow aspiration, or with bone morphogenetic proteins. Thus the intention is to equip these substances with the osteogenic capacity. Conclusions: There is currently no ideal graft material, with the exception of those materials that come directly from the patient. We hope that in the coming years we will have products that will allow us to perform rehabilitations with better results and provide a better quality of life for our patients, especially those who have more complex situations to resolve, like the patients that are operated on for head and neck cancer
Resumo:
Ring Opening Metathesis Polymerization (ROMP) of cyclic olefins is a powerful transition metal-catalyzed reaction for syntheses of polymers and copolymers. The key feature of this reaction is the [2+2]-cycloaddition mechanism, with retention of the olefinic unsaturation in the polymer chain and occurrence of living polymerization. With the development of metal-carbene type catalysts for this process, many addressed polymeric materials have been successfully prepared to be employed in several fields of the science and technology. This review summarizes recent examples of syntheses of polymers with amphiphilic features such as block, graft, brush or star copolymers; as well syntheses of biomaterials, dendronized architectures, photoactive polymers, cross-linked or self-healing materials, and polymers from renewed supplies.
Resumo:
We report the single-step derivatization reaction of a biopolymer based onL -lysine with D -biotin analogs:Co -poly(L -lysine)-graft-(ε-N -[X-D-biotinyl]-L -lysine) (PLL-X-Biotin). The valeric acid carboxylate of D -biotin is activated to an NHS ester for direct modification of amine groups in proteins and other macromolecules. NHS esters react by nucleophilic attack of an amine in the carbonyl group, releasing the NHS group, and forming a stable amide linkage. NHS-X-Biotin is the simplest biotinylation reagent commercially available. In contrast withD -biotin, it has a longer spacer arm off the valeric acid side chain allowing better binding potential for avidin or streptavidin probes. Derivatization of poly(L -lysine) (PLL) with NHS-X-Biotin led to a copolymer PLL-X-Biotin. UV-Visible, IR-FT and 1H NMR characteristics derived from synthesis are briefly discussed.
Resumo:
Copolymers of methyl methacrylate (MMA) and triethyleneglycol dimethacrylate (TEGDMA) obtained by photoinitiated polymerization using Fe(III) complexes were submitted to thermogravimetry (TGA) under dynamic air atmosphere and N2, and differential scanning calorimetric analysis (DSC). Thermal events were observed only between 90 - 110 ºC. Glass transitions were observed at ca. 100 ºC, followed by an exothermic peak at 170 ºC. The exothermic peak was assigned to a thermal curing process due to the presence of unreacted vinyl groups of the monomers. DSC revealed to be a useful tool to evaluate the curing completeness in this kind of material, using small amounts of sample in relatively short time.
Resumo:
Resection of the confluence of the superior mesenteric and portal veins has been performed most frequently in the treatment of adenocarcinoma of the pancreas, in view of the reported positive results, but it can also be used in cases of benign pancreatic neolpasias when they are strongly adhered to the mesenteric-portal trunk. Nevertheless, there is no study on the best type of venous grafts for reconstruction of the mesenteric-portal trunk when required. The choice of graft depends on the preference of the surgeon or the institution. This technical note critically discusses the use of the splenic vein as an option for mesenteric-portal trunk reconstruction after gastroduodenopancreatectomy.
Resumo:
OBJECTIVE: to verify the effectiveness of coconut water in preserving tissues for transplant. METHODS: Fifty male Wistar rats were randomly distributed in five groups, according to the following preservation solutions for tissue grafts: Group 1: Lactated Ringer; Group 2: Belzer solution; Group 3: mature coconut water; Group 4: green coconut water; Group 5: modified coconut water. In Group 5, the green coconut water has been modified like the Belzer solution. From each animal we harvasted the spleen, ovaries and skin of the back segment. These tissues were preserved for six hours in one of the solutions. Then, the grafts were reimplanted. The recovery of the function of the implanted tissues was assessed 90 days after surgery, by splenic scintigraphy and blood exame. The implanted tissues were collected for histopathological examination. RESULTS: The serum levels did not differ among groups, except for the animals in Group 5, which showed higher levels of IgG than Group 1, and differences in relation to FSH between groups 1 and 2 (p <0.001), 4 and 2 (p = 0.03) and 5 and 2 (p = 0.01). The splenic scintigraphy was not different between groups. The ovarian tissue was better preserved in mature coconut water (p <0.007). CONCLUSION: the coconut water-based solutions preserves spleen, ovary, and rat skin for six hours, maintaining their normal function.
Resumo:
The use of autologous platelet concentrates, represent a promising and innovator tools in the medicine and dentistry today. The goal is to accelerate hard and soft tissue healing. Among them, the platelet-rich plasma (PRP) is the main alternative for use in liquid form (injectable). These injectable form ofplatelet concentrates are often used in regenerative procedures and demonstrate good results. The aim of this study is to present an alternative to these platelet concentrates using the platelet-rich fibrin in liquid form (injectable) and its use with particulated bone graft materials in the polymerized form.