986 resultados para Graded index (GI)


Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To compare the periodontal conditions of Swiss Army recruits in 2006 with those of previous surveys in 1996 and 1985. MATERIAL AND METHODS: A total of six hundred and twenty-six Swiss Army recruits were examined for their periodontal conditions, caries prevalence, stomatological and functional aspects of the masticatory system and halitosis. In particular, this report deals with demographic data, the assessment of plaque index (PlI), gingival index (GI) and pocket probing depth (PPD). RESULTS: Two per cent of all teeth were missing, resulting in a mean of 27.44 teeth per subject, and 77% of the missing teeth were the result of pre-molar extractions due to orthodontic indications. The mean PlI and GI were 1.33 and 1.23, respectively. On average, 27% of the gingival units bled on probing. The mean PPD was 2.16 mm (SD 0.64). Only 3.8% of the recruits showed at least one site of PPD > or = 5 mm, and 1.4% yielded more than one site with PPD > or = 5 mm. In comparison with previous, this survey yielded lower bleeding on probing (BOP) percentages than in 1985, but slightly higher scores than in 1996. This may be attributed to increased PlI scores in 2006. However, PPD remained essentially unaltered from 1996 to 2006 after having improved significantly from 1985. CONCLUSION: A significant improvement of the periodontal conditions of young Swiss males was demonstrated to have taken place between 1985 and 1996, but no further changes during the last decade were noticed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Periodontal therapy using the combination of platelet-rich plasma (PRP) and different grafting materials has been suggested as a modality to enhance the outcome of regenerative surgery. In most clinical studies, a barrier membrane was used to cover the defects, and thus, the effects of PRP may have been masked by the effects of the barrier. The data from controlled clinical studies evaluating the effect of regenerative therapy using various grafting materials with or without PRP are still limited. The purpose of this study was to clinically compare the healing of intrabony defects treated with either a combination of an anorganic bovine bone mineral (ABBM) and PRP to those obtained with ABBM alone. METHODS: Thirty patients with advanced chronic periodontal disease and displaying one intrabony defect were randomly treated with PRP + ABBM or ABBM alone. The following clinical parameters were evaluated at baseline and 1 year after treatment: plaque index (PI), gingival index (GI), bleeding on probing (BOP), probing depth (PD), gingival recession (GR), and clinical attachment level (CAL). The primary outcome variable was CAL. RESULTS: No statistical significant differences in any of the investigated parameters between the two groups were observed at baseline. Healing was uneventful in all patients. In the PRP + ABBM group, mean PD decreased from 8.6 +/- 1.8 mm to 3.4 +/- 1.4 mm (P <0.001) and mean CAL changed from 9.9 +/- 1.7 mm to 5.3 +/- 1.8 mm (P <0.001). In the ABBM group, mean PD decreased from 8.5 +/- 2.0 mm to 3.2 +/- 1.3 mm (P <0.001) and mean CAL changed from 9.6 +/- 1.9 mm to 4.9 +/- 1.5 mm (P <0.001). CAL gains >or=3 mm were measured in 80% (12 of 15 defects) of cases treated with PRP + ABBM and in 87% (13 of 15 defects) of cases treated with ABBM alone. No statistically significant differences in any of the investigated parameters were observed between the two groups at the 1-year reevaluation. CONCLUSIONS: Within the limits of the present study, it can be concluded that 1) at 1 year after regenerative surgery with PRP + ABBM and ABBM alone, significant PD reductions and CAL gains were found, and 2) the use of PRP failed to improve the results obtained with ABBM alone.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM To assess the long-term success of maxillary fixed retainers, investigate their effect on gingival health, and analyse the survival rate after a mean period of 7 years (minimum 5 years) in retention. SUBJECTS AND METHODS Forty one subjects were included in the study A clinical examination of the upper canine to canine region including gingival index (GI), plaque index, probing depth, and bleeding on probing (BOP) was performed. Intraoral photographs and dental impressions were taken and irregularity index was determined and compared to the values of the immediate post-therapeutic values; failures of retainers were also recorded and analysed. RESULTS The mean observed retention time was 7 years and 5 months. Irregularity index: Changes occurring during retention were statistically different between the lateral incisors bonded to retainers and the canines not bonded to retainers. Only six patients showed changes in irregularity index of the lateral incisors in spite of a retainer in place. Periodontal health: The median value of the GI for all teeth bonded to upper retainers was 1.10 and the median value of the plaque index (PI) was 1.14. PI was not a significant predictor of GI. The overall BOP of the bonded teeth to the retainer for each participant was 22.3 per cent. Failure rate: Twenty-eight out of 41 patients experienced no failure of the upper bonded retainer (68.3 per cent). Detachments were the most frequent incidents. CONCLUSION Although plaque accumulation might be increased in patients with already poor oral hygiene, maxillary bonded retainers caused no significant negative effects on the periodontal health.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM To assess the periodontal conditions of two randomly selected Swiss cohorts 25 years apart. MATERIAL AND METHODS Standardized examinations were performed to assess the periodontal conditions of two randomly selected populations of the Canton of Bern; oral cleanliness was evaluated using the plaque index (PlI) and the retention index (RI). Gingival health was scored according to the gingival index (GI). Periodontal conditions were evaluated by pocket probing depth (PPD) and loss of attachment (LA). RESULTS At the first examination in 1985, 206 out of 350 subjects were evaluated, while in the second examination in 2010, 134 out of 490 subjects attended the examinations. In 1985, subjects showed a mean PlI of 1.16, and 0.77 in 2010. RI was 0.81 and 0.36 in 1985 and 2010 respectively. Mean GI was 1.34 and 0.6. The mean proportion of PPD ≤3 mm was 72% in 1985 and 97.3% in 2010. PPD ≥ 6 mm affected 2.0% in 1985 and 0.3% in 2010. In 1985, subjects had an average of 20.7 teeth, while in 2010, the average was 24.6. In 1985, 7.3% of the subjects were edentulous, while in 2010, 4.5% had no teeth. CONCLUSIONS Trends to improvements resulting in more teeth in function and better periodontal conditions were recognized.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A high-resolution multiproxy geochemical approach was applied to the sediments of Laguna Potrok Aike in an attempt to reconstruct moist and dry periods during the past 16 000 years in southeastern Patagonia. The age-depth model is inferred from AMS 14C dates and tephrochronology, and suggests moist conditions during the Lateglacial and early Holocene (16 000-8700 cal. BP) interrupted by drier conditions before the beginning of the Holocene (13 200-11 400 cal. BP). Data also imply that this period was a major warm phase in southeastern Patagonia and was approximately contemporaneous with the Younger Dryas chronozone in the Northern Hemisphere (12 700-11 500 cal. BP). After 8650 cal. BP a major drought may have caused the lowest lake level of the record. Since 7300 cal. BP, the lake level rose and was variable until the 'Little Ice Age', which was the dominant humid period after 8650 cal. BP.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Differential Phase Shift Keying (DPSK) modulation format has been shown as a robust solution for next-generation optical transmission systems. One key device enabling such systems is a delay interferometer, converting the phase modulation signal into the intensity modulation signal to be detected by the photodiodes. Usually, a standard Mach-Zehnder interferometer (MZI) is used for demodulating a DPSK signal. In this paper, we develop an MZI which is based on all-fiber Multimode Interference (MI) structure: a multimode fiber (MMF) with a central dip, located between two single-mode fibers (SMFs) without any transition zones. The MI based MZI (MI-MZI) is more stable than the standard MZI as the two arms share the same MMF, reducing the impact of the external effects, such as temperature and others. Performance of this MI-MZI is analyzed theoretically and experimentally from transmission spectrum. Experimental results shows that high interference extinction ratio is obtained, which is far higher than that obtained from a normal graded-index based MI-MZI. Finally, by software simulation, we demonstrate that our proposed MI-MZI can be used for demodulating a 40 Gbps DPSK signal. The performance of the MI-MZI based DPSK receiver is analyzed from the sensitivity. Simulation results show that sensitivity of the proposed receiver is about -22.3 dBm for a BER of 10-15 and about -23.8 dBm for a BER of 10-9.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

El objetivo principal de esta tesis ha sido el diseño y la optimización de receptores implementados con fibra óptica, para ser usados en redes ópticas de alta velocidad que empleen formatos de modulación de fase. En los últimos años, los formatos de modulación de fase (Phase Shift keying, PSK) han captado gran atención debido a la mejora de sus prestaciones respecto a los formatos de modulación convencionales. Principalmente, presentan una mejora de la eficiencia espectral y una mayor tolerancia a la degradación de la señal causada por la dispersión cromática, la dispersión por modo de polarización y los efectos no-lineales en la fibra óptica. En este trabajo, se analizan en detalle los formatos PSK, incluyendo sus variantes de modulación de fase diferencial (Differential Phase Shift Keying, DPSK), en cuadratura (Differential Quadrature Phase Shift Keying, DQPSK) y multiplexación en polarización (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), con la finalidad de diseñar y optimizar los receptores que permita su demodulación. Para ello, se han analizado y desarrollado nuevas estructuras que ofrecen una mejora en las prestaciones del receptor y una reducción de coste comparadas con las actualmente disponibles. Para la demodulación de señales DPSK, en esta tesis, se proponen dos nuevos receptores basados en un interferómetro en línea Mach-Zehnder (MZI) implementado con tecnología todo-fibra. El principio de funcionamiento de los MZI todo-fibra propuestos se asienta en la interferencia modal que se produce en una fibra multimodo (MMF) cuando se situada entre dos monomodo (SMF). Este tipo de configuración (monomodo-multimodo-monomodo, SMS) presenta un buen ratio de extinción interferente si la potencia acoplada en la fibra multimodo se reparte, principal y equitativamente, entre dos modos dominantes. Con este objetivo, se han estudiado y demostrado tanto teórica como experimentalmente dos nuevas estructuras SMS que mejoran el ratio de extinción. Una de las propuestas se basa en emplear una fibra multimodo de índice gradual cuyo perfil del índice de refracción presenta un hundimiento en su zona central. La otra consiste en una estructura SMS con las fibras desalineadas y donde la fibra multimodo es una fibra de índice gradual convencional. Para las dos estructuras, mediante el análisis teórico desarrollado, se ha demostrado que el 80 – 90% de la potencia de entrada se acopla a los dos modos dominantes de la fibra multimodo y se consigue una diferencia inferior al 10% entre ellos. También se ha demostrado experimentalmente que se puede obtener un ratio de extinción de al menos 12 dB. Con el objeto de demostrar la capacidad de estas estructuras para ser empleadas como demoduladores de señales DPSK, se han realizado numerosas simulaciones de un sistema de transmisión óptico completo y se ha analizado la calidad del receptor bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo o la tolerancia a las dispersiones cromática y por modo de polarización. En todos los casos se ha concluido que los receptores propuestos presentan rendimientos comparables a los obtenidos con receptores convencionales. En esta tesis, también se presenta un diseño alternativo para la implementación de un receptor DQPSK, basado en el uso de una fibra mantenedora de la polarización (PMF). A través del análisi teórico y del desarrollo de simulaciones numéricas, se ha demostrado que el receptor DQPSK propuesto presenta prestaciones similares a los convencionales. Para complementar el trabajo realizado sobre el receptor DQPSK basado en PMF, se ha extendido el estudio de su principio de demodulación con el objeto de demodular señales PM-DQPSK, obteniendo como resultado la propuesta de una nueva estructura de demodulación. El receptor PM-DQPSK propuesto se basa en la estructura conjunta de una única línea de retardo junto con un rotador de polarización. Se ha analizado la calidad de los receptores DQPSK y PM-DQPSK bajo diferentes perspectivas, tales como la sensibilidad, la tolerancia a un filtrado óptico severo, la tolerancia a las dispersiones cromática y por modo de polarización o su comportamiento bajo condiciones no-ideales. En comparación con los receptores convencionales, nuestra propuesta exhibe prestaciones similares y además permite un diseño más simple que redunda en un coste potencialmente menor. En las redes de comunicaciones ópticas actuales se utiliza la tecnología de multimplexación en longitud de onda (WDM) que obliga al uso de filtros ópticos con bandas de paso lo más estrechas posibles y a emplear una serie de dispositivos que incorporan filtros en su arquitectura, tales como los multiplexores, demultiplexores, ROADMs, conmutadores y OXCs. Todos estos dispositivos conectados entre sí son equivalentes a una cadena de filtros cuyo ancho de banda se va haciendo cada vez más estrecho, llegando a distorsionar la forma de onda de las señales. Por esto, además de analizar el impacto del filtrado óptico en las señales de 40 Gbps DQPSK y 100 Gbps PM-DQPSK, este trabajo de tesis se completa estudiando qué tipo de filtro óptico minimiza las degradaciones causadas en la señal y analizando el número máximo de filtros concatenados que permiten mantener la calidad requerida al sistema. Se han estudiado y simulado cuatro tipos de filtros ópticos;Butterworth, Bessel, FBG y F-P. ABSTRACT The objective of this thesis is the design and optimization of optical fiber-based phase shift keying (PSK) demodulators for high-bit-rate optical networks. PSK modulation formats have attracted significant attention in recent years, because of the better performance with respect to conventional modulation formats. Principally, PSK signals can improve spectrum efficiency and tolerate more signal degradation caused by chromatic dispersion, polarization mode dispersion and nonlinearities in the fiber. In this work, many PSK formats were analyzed in detail, including the variants of differential phase modulation (Differential Phase Shift Keying, DPSK), in quadrature (Differential Quadrature Phase Shift Keying, DQPSK) and polarization multiplexing (Polarization Multiplexing Differential Quadrature Phase Shift Keying, PM-DQPSK), in order to design and optimize receivers enabling demodulations. Therefore, novel structures, which offer good receiver performances and a reduction in cost compared to the current structures, have been analyzed and developed. Two novel receivers based on an all-fiber in-line Mach-Zehnder interferometer (MZI) were proposed for DPSK signal demodulation in this thesis. The operating principle of the all-fiber MZI is based on the modal interference that occurs in a multimode fiber (MMF) when it is located between two single-mode fibers (SMFs). This type of configuration (Single-mode-multimode-single-mode, SMS) can provide a good extinction ratio if the incoming power from the SMF could be coupled equally into two dominant modes excited in the MMF. In order to improve the interference extinction ratio, two novel SMS structures have been studied and demonstrated, theoretically and experimentally. One of the two proposed MZIs is based on a graded-index multimode fiber (MMF) with a central dip in the index profile, located between two single-mode fibers (SMFs). The other one is based on a conventional graded-index MMF mismatch spliced between two SMFs. Theoretical analysis has shown that, in these two schemes, 80 – 90% of the incoming power can be coupled into the two dominant modes exited in the MMF, and the power difference between them is only ~10%. Experimental results show that interference extinction ratio of 12 dB could be obtained. In order to demonstrate the capacity of these two structures for use as DPSK signal demodulators, numerical simulations in a completed optical transmission system have been carried out, and the receiver quality has been analyzed under different perspectives, such as sensitivity, tolerance to severe optical filtering or tolerance to chromatic and polarization mode dispersion. In all cases, from the simulation results we can conclude that the two proposed receivers can provide performances comparable to conventional ones. In this thesis, an alternative design for the implementation of a DQPSK receiver, which is based on a polarization maintaining fiber (PMF), was also presented. To complement the work made for the PMF-based DQPSK receiver, the study of the demodulation principle has been extended to demodulate PM-DQPSK signals, resulting in the proposal of a novel demodulation structure. The proposed PM-DQPSK receiver is based on only one delay line and a polarization rotator. The quality of the proposed DQPSK and PM-DQPSK receivers under different perspectives, such as sensitivity, tolerance to severe optical filtering, tolerance to chromatic dispersion and polarization mode dispersion, or behavior under non-ideal conditions. Compared with the conventional receivers, our proposals exhibit similar performances but allow a simpler design which can potentially reduce the cost. The wavelength division multiplexing (WDM) technology used in current optical communications networks requires the use of optical filters with a passband as narrow as possible, and the use of a series of devices that incorporate filters in their architecture, such as multiplexers, demultiplexers, switches, reconfigurable add-drop multiplexers (ROADMs) and optical cross-connects (OXCs). All these devices connected together are equivalent to a chain of filters whose bandwidth becomes increasingly narrow, resulting in distortion to the waveform of the signals. Therefore, in addition to analyzing the impact of optical filtering on signal of 40 Gbps DQPSK and 100 Gbps PM-DQPSK, we study which kind of optical filter minimizes the signal degradation and analyze the maximum number of concatenated filters for maintaining the required quality of the system. Four types of optical filters, including Butterworth, Bessel, FBG and FP, have studied and simulated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We develop an analytical theory which allows us to identify the information spectral density limits of multimode optical fiber transmission systems. Our approach takes into account the Kerr-effect induced interactions of the propagating spatial modes and derives closed-form expressions for the spectral density of the corresponding nonlinear distortion. Experimental characterization results have confirmed the accuracy of the proposed models. Application of our theory in different FMF transmission scenarios has predicted a ~10% variation in total system throughput due to changes associated with inter-mode nonlinear interactions, in agreement with an observed 3dB increase in nonlinear noise power spectral density for a graded index four LP mode fiber. © 2013 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded-index perfluorinated polymer optical fiber. © 2014 SPIE.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To perform a long-term clinical evaluation of the periodontium of removable parti al denture (RPD) wearers, comparing the direct pillar teeth of tooth-supported and toothtissue supported RPDs. Method: Fifty patients with mean age of 45 years were enrolled in the study. The individuals were examined by a single examiner at the moment of denture installation and after 3, 6, 9 and 12 months. In each exam, the following parameters were verified: gingival recession (GR), probing depth (PD), plaque index (PI), gingival index (GI) e amount kerati nized mucosa (KM). All patients received oral hygiene instructions and prophylaxis and, when necessary, scaling and root planing. An analysis from the confidence interval was done to evaluate the endpoints regarding the type of denture in the direct pillar group. Results: The tooth-tissue supported dentures showed significantly higher GR, GI and PI values, and significantly lower KM values. Over time, neither of the types of denture presented statistically significant difference from the initial to the final examination for the parameters GR, PD, KM and GI, while the PI was significant only for the tooth-supported dentures. Conclusion: Pillar teeth adjacent to free ends presented a less favorable periodontal conditi on than the pillar teeth adjacent to intercalated spaces. However, the use of RPD did not aggravate the initial condition, after a follow-up period of 12 months. The findings of the study indicate that, within 1 year, there were no significant differences between the direct pillars of the toothsupported and tooth-ti ssue supported dentures, and suggest the need of professional follow up for a longer period.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymer Optical Fibers have occupied historically a place for large core flexible fibers operating in short distances. In addition to their practical passive application in short-haul communication they constitute a potential research field as active devices with organic dopants. Organic dyes are preferred as dopants over organic semiconductors due to their higher optical cross section. Thus organic dyes as gain media in a polymer fiber is used to develop efficient and narrow laser sources with a tunability throughout the visible region or optical amplifier with high gain. Dyes incorporated in fiber form has added advantage over other solid state forms such as films since the pump power required to excite the molecules in the core of the fiber is less thereby utilising the pump power effectively. In 1987, Muto et.al investigated a dye doped step index polymer fiber laser. Afterwards, numerous researches have been carried out in this area demonstrating laser emission from step index, graded index and hollow optical fibers incorporating various dyes. Among various dyes, Rhodamine6G is the most widely and commonly used laser dye for the last four decades. Rhodamine6G has many desirable optical properties which make it preferable over other organic dyes such as Coumarin, Nile Blue, Curcumin etc. The research focus on the implementation of efficient fiber lasers and amplifiers for short fiber distances. Developing efficient plastic lasers with electrical pumping can be a new proposal in this field which demands lowest possible threshold pump energy of the gain medium in the cavity as an important parameter. One way of improving the efficiency of the lasers, through low threshold pump energy, is by modifying the gain of the amplifiers in the resonator/cavity. Success in the field of Radiative Decay Engineering can pave way to this problem. Laser gain media consisting of dye-nanoparticle composites can improve the efficiency by lowering the lasing threshold and enhancing the photostability. The electric field confined near the surface of metal nanoparticles due to Localized Surface Plasmon Resonance can be very effective for the excitation of active centers to impart high optical gain for lasing. Since the Surface Plasmon Resonance of nanoparticles of gold and silver lies in the visible range, it can affect the spectral emission characteristics of organic dyes such as Rhodamine6G through plasmon field generated by the particles. The change in emission of the dye placed near metal nanoparticles depend on plasmon field strength which in turn depends on the type of metal, size of nanoparticle, surface modification of the particle and the wavelength of incident light. Progress in fabrication of different types of nanostructures lead to the advent of nanospheres, nanoalloys, core-shell and nanowires to name a few. The thesis deals with the fabrication and characterisation of polymer optical fibers with various metallic and bimetallic nanostructures incorporated in the gain media for efficient fiber lasers with low threshold and improved photostability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Heart rate asymmetry (HRA) is considered as a physiological phenomenon in healthy subjects. In this article, we propose a novel HRA index, Slope Index (SI), to quantify phase asymmetry of heart rate variability (HRV) system. We assessed the performance of proposed index in comparison with conventional (Guzik's Index (GI) and Porta's Index (PI)) HRA indices. As illustrative examples, we used two case studies: (i) differentiate physiologic RR series from synthetic RR series; and (ii) discriminate arrhythmia subjects from Healthy using beat-to-beat heart rate time series. The results showed that SI is a superior parameter than GI and PI for both case studies with maximum ROC area of 0.84 and 0.82 respectively. In contrast, GI and PI had ROC areas {0.78, 0.61} and {0.50, 0.56} in two case studies respectively. We also performed surrogate analysis to show that phase asymmetry is caused by a physiologic phenomena rather than a random nature of the signal. In conclusion, quantification of phase asymmetry of HRV provides additional information on HRA, which might have a potential clinical use to discriminate pathological HRV in future.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The heart rate asymmetry (HRA) is a disproportionate distribution of heart rate signal. The current study was designed to assess the changes in HRA in experimental conditions using Poincaré plot during parasympathetic blockade (atropine infusion) and parasympathetic enhancement (scopolamine administration). After atropine infusion, the heart rate variability in 5 out of 8 subjects was found asymmetric. In contrast, all 8 subjects were found to be asymmetric during scopolamine administration. The physiological relevance of HRA was demonstrated by showing correlation with standard frequency domain parameters during all phases of the experiment. The deviation of asymmetry index (GI ( p )) from symmetric range was further analyzed, which was maximum during scopolamine administration and minimum during atropine infusion. These findings suggest that parasympathetic block reduces the prevalence of HRA, and has significant correlation of GI ( p ) with frequency domain features of HRV analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the effective coupling coefficient k(eff) and the self-coupling coefficient zeta(1) are introduced to describe the characteristic of gratings in a resonant situation when the effects of radiation and other partial waves coupling are considered. The dependence of these two coupling coefficients on grating tooth shapes and depths and the dimensions of graded refractive index (GRIN) waveguides is numerically analysed. The results show that the gratings with linear GRIN waveguides have the largest \k(eff)\. The possibility of realizing a complex-coupled DFB laser, even a pure gain or loss coupled DFB laser, employing only a real refractive index coupled grating is also discussed.