983 resultados para Gibraltar flux
Resumo:
Gene flow (defined as allele exchange between populations) and gene flux (defined as allele exchange during meiosis in heterokaryotypic females) are important factors decreasing genetic differentiation between populations and inversions. Many chromosomal inversions are under strong selection and their role in recombination reduction enhances the maintenance of their genetic distinctness. Here we analyze levels and patterns of nucleotide diversity, selection and demographic history, using 37 individuals of Drosophila subobscura from Mount Parnes (Greece) and Barcelona (Spain). Our sampling focused on two frequent O-chromosome arrangements that differ by two overlapping inversions (OST and O3+4), which are differentially adapted to the environment as observed by their opposing latitudinal clines in inversion frequencies. The six analyzed genes (Pif1A, Abi, Sqd, Yrt, Atpa and Fmr1) were selected for their location across the O-chromosome and their implication in thermal adaptation. Despite the extensive gene flux detected outside the inverted region, significant genetic differentiation between both arrangements was found inside it. However, high levels of gene flow were detected for all six genes when comparing the same arrangement among populations. These results suggest that the adaptive value of inversions is maintained, regardless of the lack of genetic differentiation within arrangements from different populations, and thus favors the Local Adaptation hypothesis over the Coadapted Genome hypothesis as the basis of the selection acting on inversions in these populations.
Resumo:
Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.
Resumo:
BACKGROUND: The heart relies on continuous energy production and imbalances herein impair cardiac function directly. The tricarboxylic acid (TCA) cycle is the primary means of energy generation in the healthy myocardium, but direct noninvasive quantification of metabolic fluxes is challenging due to the low concentration of most metabolites. Hyperpolarized (13)C magnetic resonance spectroscopy (MRS) provides the opportunity to measure cellular metabolism in real time in vivo. The aim of this work was to noninvasively measure myocardial TCA cycle flux (VTCA) in vivo within a single minute. METHODS AND RESULTS: Hyperpolarized [1-(13)C]acetate was administered at different concentrations in healthy rats. (13)C incorporation into [1-(13)C]acetylcarnitine and the TCA cycle intermediate [5-(13)C]citrate was dynamically detected in vivo with a time resolution of 3s. Different kinetic models were established and evaluated to determine the metabolic fluxes by simultaneously fitting the evolution of the (13)C labeling in acetate, acetylcarnitine, and citrate. VTCA was estimated to be 6.7±1.7μmol·g(-1)·min(-1) (dry weight), and was best estimated with a model using only the labeling in citrate and acetylcarnitine, independent of the precursor. The TCA cycle rate was not linear with the citrate-to-acetate metabolite ratio, and could thus not be quantified using a ratiometric approach. The (13)C signal evolution of citrate, i.e. citrate formation was independent of the amount of injected acetate, while the (13)C signal evolution of acetylcarnitine revealed a dose dependency with the injected acetate. The (13)C labeling of citrate did not correlate to that of acetylcarnitine, leading to the hypothesis that acetylcarnitine formation is not an indication of mitochondrial TCA cycle activity in the heart. CONCLUSIONS: Hyperpolarized [1-(13)C]acetate is a metabolic probe independent of pyruvate dehydrogenase (PDH) activity. It allows the direct estimation of VTCA in vivo, which was shown to be neither dependent on the administered acetate dose nor on the (13)C labeling of acetylcarnitine. Dynamic (13)C MRS coupled to the injection of hyperpolarized [1-(13)C]acetate can enable the measurement of metabolic changes during impaired heart function.
Resumo:
Les membranes de dialyse à haut flux et à faible flux pourraient être liées à différents profils hemodynamiques pendant les séances de dialyse. Cette étude visait à comparer le profil hémodynamique des certains filtres de dialyse polysulfone couramment utilisés en Suisse. Nous avons réalisé une étude ouverte, cross-over, avec 25 pazients en hémodialyse On a comparés entre eux 4 filtres de polysulfone de la surface de 1 8 m2 A (Revaclear HF, Gambro), B (Helixone HF, Fresenius), C (Xevonta HF, BBraun) et D (Helixone LF Fresenius). Le profil hémodynamique a été mesuré en utilisant une technique non invasive et au patient a été demandé de fournir une opinion sur la tolérance à la seance de dialyse. La même membrane était utilisée pour 3 séances de suites Chaque semaine la membrane de dialyse était modifiée conformément à la séquence de randomisation. Pour chaque patient on a recueillie les données de 12 séances de dialyse. L'étude a été réalisé sur trois mois à compter de novembre 2012. Les analyses ont encore une fois montré la supériorité des filtres à haut débit comparés aux filtres à faible débit, et ne tendance à la supériorité du filtre Helixone (haut debit) comparé aux deux autres membranes. Les filtres à faible débit par rapport a ceux a haut debit sont associés ä une pression systolique et diastolique plus élevées a des résistances périphériques plus hautes et à un débit cardiaque plus faible L incidence d'épisodes d'hypotension en dialyse était la suivante: Revaclear HF (A) 70 Helixone HF (B) 87 Xevonta HF 73 (C), Helixone LF (D) 75. Le nombre d'épisodes d hypotension associée au filtre B était supérieure, de manière significative. La membrane à faible flux était associée à une pression artérielle supérieure à celles des membranes de haut flux. La membrane à haut flux Helixone garantie la meilleure efficacité de dialyse. Malheureusement, la même membrane est associée à une augmentation de l'incidence des épisodes d'hypotension, probablement due à un déséquilibré hé à l'efficacité de la dialyse. Malgré ces résultats, la tolérance subjective pour les différents filtres était comparable.
Resumo:
We examined the genetic population structure of the european hake (Merluccius merluccius) using electrophoretically detectable population markers in 35 protein loci. Samples were collected from 7 locations in the Atlantic Ocean and Mediterranean Sea. Six loci were polymorphic using the 0.05 criterion of polymorphism. Sample heterozigosities ranged from 0.052 to 0.072 and averaged 0.0625. In this study, significant allele frequency differences were detected between Atlantic and Mediterranean populations in three polymorphic loci: GAPDH-1*, GPI-2* and SOD-1*. Two major genetic groups were considered: a North-Atlantic stock and the Mediterranean stock. The Nei genetic distance, D, (based on 33 loci) between samples from these two groups ranged from 0.002 to 0.006. Genetic differenciation between these areas appears to reflect the barrier effect of Strait of Gibraltar. On average over loci, 96.92 % of the total gene diversity was contained within samples, 0.23 % expressed differences among locations within areas, and 2.64 % differences between regions. A review of morphological variation together with the genetic data presented here suggest that the populations of hake from these areas are subdivided into two different stocks: the North-Atlantic stock and the Mediterranean stock. The most conservative approach to the management of these stocks is to consider the Atlantic and Mediterranean stocks independently from oneanother
Resumo:
En collectant plus de deux millions de tweets reliés au centenaire de la Grande Guerre, de nombreuses questions méthodologiques se sont posées, interrogeant par exemple la notion de corpus, les relations entre historien.ne.s et archivistes, le traitement du passé à une ère de données massives. Cette intervention se penche sur l'une de ces questions: comment fonder une recherche sur des sources primaires en flux? Comment résoudre la contradiction inhérente entre l'archive, réputée figée, et les données nées numériques qui sont émises en flux?
Resumo:
Synchronous machines with an AC converter are used mainly in large drives, for example in ship propulsion drives as well as in rolling mill drives in steel industry. These motors are used because of their high efficiency, high overload capacity and good performance in the field weakening area. Present day drives for electrically excited synchronous motors are equipped with position sensors. Most drives for electrically excited synchronous motors will be equipped with position sensors also in future. This kind of drives with good dynamics are mainly used in metal industry. Drives without a position sensor can be used e.g. in ship propulsion and in large pump and blower drives. Nowadays, these drives are equipped with a position sensor, too. The tendency is to avoid a position sensor if possible, since a sensor reduces the reliability of the drive and increases costs (latter is not very significant for large drives). A new control technique for a synchronous motor drive is a combination of the Direct Flux Linkage Control (DFLC) based on a voltage model and a supervising method (e.g. current model). This combination is called Direct Torque Control method (DTC). In the case of the position sensorless drive, the DTC can be implemented by using other supervising methods that keep the stator flux linkage origin centered. In this thesis, a method for the observation of the drift of the real stator flux linkage in the DTC drive is introduced. It is also shown how this method can be used as a supervising method that keeps the stator flux linkage origin centered in the case of the DTC. In the position sensorless case, a synchronous motor can be started up with the DTC control, when a method for the determination of the initial rotor position presented in this thesis is used. The load characteristics of such a drive are not very good at low rotational speeds. Furthermore, continuous operation at a zero speed and at a low rotational speed is not possible, which is partly due to the problems related to the flux linkage estimate. For operation in a low speed area, a stator current control method based on the DFLC modulator (DMCQ is presented. With the DMCC, it is possible to start up and operate a synchronous motor at a zero speed and at low rotational speeds in general. The DMCC is necessary in situations where high torque (e.g. nominal torque) is required at the starting moment, or if the motor runs several seconds at a zero speed or at a low speed range (up to 2 Hz). The behaviour of the described methods is shown with test results. The test results are presented for the direct flux linkage and torque controlled test drive system with a 14.5 kVA, four pole salient pole synchronous motor with a damper winding and electric excitation. The static accuracy of the drive is verified by measuring the torque in a static load operation, and the dynamics of the drive is proven in load transient tests. The performance of the drive concept presented in this work is sufficient e.g. for ship propulsion and for large pump drives. Furthermore, the developed methods are almost independent of the machine parameters.
Resumo:
Concentrated winding permanent magnet machines and their electromagnetic properties are studied in this doctoral thesis. The thesis includes a number of main tasks related to the application of permanent magnets in concentrated winding open slot machines. Suitable analytical methods are required for the first design calculations of a new machine. Concentrated winding machines differ from conventional integral slot winding machines in such a way that adapted analytical calculation methods are needed. A simple analytical model for calculating the concentrated winding axial flux machines is provided. The next three main design tasks are discussed in more detail in the thesis. The magnetic length of the rotor surface magnet machines is studied, and it is shown that the traditional methods have to be modified also in this respect. An important topic in this study has been to evaluate and minimize the rotor permanent magnet Joule losses by using segmented magnets in the calculations and experiments. Determination of the magnetizing and leakage inductances for a concentrated winding machine and the torque production capability of concentrated winding machines with different pole pair numbers are studied, and the results are compared with the corresponding properties of integral slot winding machines. The thesis introduces a new practical permanent magnet motor type for industrial use. The special features of the machine are based on the option of using concentrated winding open slot constructions of permanent magnet synchronous machines in the normal speed ranges of industrial motors, for instance up to 3000 min-1, without excessive rotor losses. By applying the analytical equations and methods introduced in the thesis, a 37 kW 2400 min-1 12-slot 10-pole axial flux machine with rotor-surfacemounted magnets is designed. The performance of the designed motor is determined by experimental measurements and finite element calculations.
Resumo:
The Switched Reluctance technology is probably best suited for industrial low-speed or zerospeed applications where the power can be small but the torque or the force in linear movement cases might be relatively high. Because of its simple structure the SR-motor is an interesting alternative for low power applications where pneumatic or hydraulic linear drives are to be avoided. This study analyses the basic parts of an LSR-motor which are the two mover poles and one stator pole and which form the “basic pole pair” in linear-movement transversal-flux switchedreluctance motors. The static properties of the basic pole pair are modelled and the basic design rules are derived. The models developed are validated with experiments. A one-sided one-polepair transversal-flux switched-reluctance-linear-motor prototype is demonstrated and its static properties are measured. The modelling of the static properties is performed with FEM-calculations. Two-dimensional models are accurate enough to model the static key features for the basic dimensioning of LSRmotors. Three-dimensional models must be used in order to get the most accurate calculation results of the static traction force production. The developed dimensioning and modelling methods, which could be systematically validated by laboratory measurements, are the most significant contributions of this thesis.
Resumo:
The recent digitization, fragmentation of the media landscape and consumers’ changing media behavior are all changes that have had drastic effects on creating marketing communications. In order to create effective marketing communications large advertisers are now co-operating with a variety of marketing communications companies. The purpose of the study is to understand how advertisers perceive these different companies and more importantly how do advertisers expect their roles to change in the future as the media landscape continues to evolve. Especially the changing roles of advertising agencies and media agencies are examined as they are at the moment the most relevant partners of the advertisers. However, the research is conducted from a network perspective rather than focusing on single actors of the marketing communications industry network. The research was conducted using a qualitative theme interview method. The empirical data was gathered by interviewing representatives from nine of the 50 largest Finnish advertisers measured by media spending. Thus, the research was conducted solely from large B2C advertisers’ perspective while the views of their other relevant actors of the network were left unexplored. The interviewees were chosen with a focus on variety of points of view. The analytical framework that was used to analyze the gathered data was built the IMP group’s industrial network model that consists of actors, their resources and activities. As technology driven media landscape fragmentation and consumers’ changing media behavior continue to increase the complexity of creating marketing communications, advertisers are going to need to rely on a growing number of partnerships as they see that the current actors of the network will not be able to widen their expertise to answer to these new needs. The advertisers expect to form new partnerships with actors that are more specialized and able to react and produce activities more quickly than at the moment. Thus, new smaller and more agile actors with looser structures are going to appear to fill these new needs. Therefore, the need of co-operation between the actors is going to become more important. These changes pose the biggest threat for traditional advertising agencies as they were seen as being most unable to cope with the ongoing change. Media agencies are in a more favorable position for remaining relevant for the advertisers as they will be able to justify their activities and provided value by leveraging their data handling abilities. In general the advertisers expect to be working with a limited number of close actors and in addition having a network of smaller actors, which are used on a more ad hoc basis.
Resumo:
Measurement is a tool for researching. Therefore, it is important that the measuring process is carried out correctly, without distorting the signal or the measured event. Researches of thermoelectric phenomena have been focused more on transverse thermoelectric phenomena during recent decades. Transverse Seebeck effect enables to produce thinner and faster heat flux sensor than before. Studies about transverse Seebeck effect have so far focused on materials, so in this Master’s Thesis instrumentation of transverse Seebeck effect based heat flux sensor is studied, This Master’s Thesis examines an equivalent circuit of transverse Seebeck effect heat flux sensors, their connectivity to electronics and choosing and design a right type amplifier. The research is carried out with a case study which is Gradient Heat Flux Sensors and an electrical motor. In this work, a general equivalent circuit was presented for the transverse Seebeck effect-based heat flux sensor. An amplifier was designed for the sensor of the case study, and the solution was produced for the measurement of the local heat flux of the electric motor to improve the electromagnetic compatibility.
Resumo:
This master’s thesis is devoted to study different heat flux measurement techniques such as differential temperature sensors, semi-infinite surface temperature methods, calorimetric sensors and gradient heat flux sensors. The possibility to use Gradient Heat Flux Sensors (GHFS) to measure heat flux in the combustion chamber of compression ignited reciprocating internal combustion engines was considered in more detail. A. Mityakov conducted an experiment, where Gradient Heat Flux Sensor was placed in four stroke diesel engine Indenor XL4D to measure heat flux in the combustion chamber. The results which were obtained from the experiment were compared with model’s numerical output. This model (a one – dimensional single zone model) was implemented with help of MathCAD and the result of this implementation is graph of heat flux in combustion chamber in relation to the crank angle. The values of heat flux throughout the cycle obtained with aid of heat flux sensor and theoretically were sufficiently similar, but not identical. Such deviation is rather common for this type of experiment.
Resumo:
In nuclear reactors, the occurrence of critical heat flux leads to fuel rod overheating with clad fusion and radioactive products leakage. To predict the effects of such phenomenon, experiments are performed using electrically heated rods to simulate operational and accidental conditions of nuclear fuel rods. In the present work, it is performed a theoretical analysis of the drying and rewetting front propagation during a critical heat flux experiment, starting with the application of an electrical power step from steady state condition. After the occurrence of critical heat flux, the drying front propagation is predicted. After a few seconds, a power cut is considered and the rewetting front behavior is analytically observed. Studies performed with various values of coolant mass flow rate show that this variable has more influence on the drying front velocity than on the rewetting one.
Resumo:
The application of flux cored arc welding (FCAW) has increased in manufacturing and fabrication. Even though FCAW is well known for its good capability in producing quality welds, few reports have been published on the cause of the relatively high diffusible hydrogen content in the weld metal and its relation with the ingredients used in the wire production and with the welding parameters (mainly welding current). This paper describes experiments where data obtained from weld metal diffusible hydrogen analysis, metal droplet collection, and high-speed recording of metal droplet transfer were used to evaluate the effect of welding current on diffusible hydrogen content in the weld metal. The results from gas chromatography analysis showed that weld metal hydrogen content indeed increased with welding current. A polynomial regressional analysis concluded that hydrogen increase with current was better described by a linear function with proportional constant of approximately 0.7 or 70%. Different from the GMA welding transfer behavior, statistical analysis showed only a small increase in metal droplet size with increasing current. The metal transfer mode remained in the globular range for currents between 100 and 150 A. The most surprising findings were with the high-speed cinematography recording. Observing the high speed movies, it was possible to see that at low current, "unmelted" flux sporadically touched the weld pool but at higher current, the flux remained touching the weld pool during the whole time of droplet formation and transfer. It is believed that since the flux has ingredients that contain hydrogen, hydrogen passes through the arc undisturbed, going to the weld bead intact and increasing the hydrogen content in the weld metal. Another important observation is regarding to droplet size. Droplet size increased with increasing current because forces from decomposed gases from the flux could sustain the droplets, retarding their transfer and allowing them to grow.