970 resultados para Generalized failure rate


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction The most commonly used method in neonatal hearing screening programs is transient evoked otoacoustic emissions in the first stage of the process. There are few studies comparing transient evoked otoacoustic emissions with distortion product, but some authors have investigated the issue. Objective To correlate the results of transient evoked and distortion product otoacoustic emissions in a Brazilian maternity hospital. Methods This is a cross-sectional, comparative, and prospective study. The study included 579 newborns, ranging from 6 to 54 days of age, born in a low-risk maternity hospital and assessed for hearing loss. All neonates underwent hearing screening by transient evoked and distortion product otoacoustic emissions. The results were analyzed using the Spearman correlation test to relate the two procedures. Results The pass index on transient evoked otoacoustic emissions was 95% and on distortion product otoacoustic emissions was 91%. The comparison of the two procedures showed that 91% of neonates passed on both procedures, 4.5% passed only on transient evoked otoacoustic emissions, 0.5% passed only on distortion product otoacoustic emissions, and 4% failed on both procedures. The inferential analysis showed a significant strong positive relationship between the two procedures. Conclusion The failure rate was higher in distortion product otoacoustic emissions when compared with transient evoked; however, there was correlation between the results of the procedures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper we introduce an extension of the Lindley distribution which offers a more flexible model for lifetime data. Several statistical properties of the distribution are explored, such as the density, (reversed) failure rate, (reversed) mean residual lifetime, moments, order statistics, Bonferroni and Lorenz curves. Estimation using the maximum likelihood and inference of a random sample from the distribution are investigated. A real data application illustrates the performance of the distribution. (C) 2011 The Korean Statistical Society. Published by Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Conway-Maxwell Poisson (COMP) distribution as an extension of the Poisson distribution is a popular model for analyzing counting data. For the first time, we introduce a new three parameter distribution, so-called the exponential-Conway-Maxwell Poisson (ECOMP) distribution, that contains as sub-models the exponential-geometric and exponential-Poisson distributions proposed by Adamidis and Loukas (Stat Probab Lett 39:35-42, 1998) and KuAY (Comput Stat Data Anal 51:4497-4509, 2007), respectively. The new density function can be expressed as a mixture of exponential density functions. Expansions for moments, moment generating function and some statistical measures are provided. The density function of the order statistics can also be expressed as a mixture of exponential densities. We derive two formulae for the moments of order statistics. The elements of the observed information matrix are provided. Two applications illustrate the usefulness of the new distribution to analyze positive data.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To describe noninvasive positive-pressure ventilation use in intensive care unit clinical practice, factors associated with NPPV failure and the associated prognosis. METHODS: A prospective cohort study. RESULTS: Medical disorders (59%) and elective surgery (21%) were the main causes for admission to the intensive care unit. The main indications for the initiation of noninvasive positive-pressure ventilation were the following: post-extubation, acute respiratory failure and use as an adjunctive technique to chest physiotherapy. The noninvasive positive-pressure ventilation failure group was older and had a higher Simplified Acute Physiology Score II score. The noninvasive positive-pressure ventilation failure rate was 35%. The main reasons for intubation were acute respiratory failure (55%) and a decreased level of consciousness (20%). The noninvasive positive-pressure ventilation failure group presented a shorter period of noninvasive positive-pressure ventilation use than the successful group [three (2-5) versus four (3-7) days]; they had lower levels of pH, HCO3 and base excess, and the FiO(2) level was higher. These patients also presented lower PaO2:FiO2 ratios; on the last day of support, the inspiratory positive airway pressure and expiratory positive airway pressure were higher. The failure group also had a longer average duration of stay in the intensive care unit [17 (10-26) days vs. 8 (5-14) days], as well as a higher mortality rate (9 vs. 51%). There was an association between failure and mortality, which had an odds ratio (95% CI) of 10.6 (5.93 - 19.07). The multiple logistic regression analysis using noninvasive positive pressure ventilation failure as a dependent variable found that treatment tended to fail in patients with a Simplified Acute Physiology Score II >= 34, an inspiratory positive airway pressure level >= 15 cmH2O and pH<7.40. CONCLUSION: The indications for noninvasive positive-pressure ventilation were quite varied. The failure group had a longer intensive care unit stay and higher mortality. Simplified Acute Physiology Score II >= 34, pH<7.40 and higher inspiratory positive airway pressure levels were associated with failure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: This study evaluated the 56-month clinical performance of Class I and II resin composite restorations. Filtek P60 was compared with Filtek Z250, which are both indicated for posterior restorations but differ in terms of handling characteristics. The null hypothesis tested was that there is no difference in the clinical performance of the two resin composites in posterior teeth. Material and Methods: Thirty-three patients were treated by the same operator, who prepared 48 Class I and 42 Class II cavities, which were restored with Single Bond/Filtek Z250 or Single Bond/Filtek P60 restorative systems. Restorations were evaluated by two independent examiners at baseline and after 56 months, using the modified USPHS criteria. Data were analyzed statistically using Chi-square and Fisher's Exact tests (alpha=0.05). Results: After 56 months, 25 patients (31 Class I and 36 Class II) were analyzed. A 3% failure rate occurred due to secondary caries and excessive loss of anatomic form for P60. For both restorative systems, there were no significant differences in secondary caries and postoperative sensitivity. However, significant changes were observed with respect to anatomic form, marginal discoloration, and marginal adaptation. Significant decreases in surface texture were observed exclusively for the Z250 restorations. Conclusions: Both restorative systems can be used for posterior restorations and can be expected to perform well in the oral environment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a new family of survival distributions is presented. It is derived by considering that the latent number of failure causes follows a Poisson distribution and the time for these causes to be activated follows an exponential distribution. Three different activation schemes are also considered. Moreover, we propose the inclusion of covariates in the model formulation in order to study their effect on the expected value of the number of causes and on the failure rate function. Inferential procedure based on the maximum likelihood method is discussed and evaluated via simulation. The developed methodology is illustrated on a real data set on ovarian cancer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of sex, implant characteristics, and bone grafting on the survival rate of dual acid-etched (DAE) implants. Materials and Methods: Patients treated with internal-hex DAE implants for single-tooth replacement in a military dental clinic between January 2005 and December 2010 were included in this study. Clinical data related to implant characteristics, implant location, presence of grafted bone, and implant failures were collected. The primary outcome was implant loss. The survival rate was analyzed using the Kaplan-Meier method. Cox regression modeling was used to determine which factors would predict implant failure. Results: DAE implants were evaluated in a total of 988 patients (80.3% men). Twenty-four (2.4%) implants failed, most were cylindric (54.2%) with regular platforms (70.8%) and were 10 mm long (58.3%). The failure rate was 2.4% for the anterior maxilla, 3.3% for the posterior maxilla, 1.6% for the anterior mandible, and 2.0% for posterior mandible. The cumulative survival rate was 97.6%. The failure rate was 8.8% in implants placed after sinus augmentation, 7.3% in bone block-grafted areas, and 1.6% in native bone. Based on multivariable analysis (Cox regression), sinus augmentation and bone block grafting had a statistically significant effect on implant failure; the hazard ratios were 5.5 and 4.6, respectively. Conclusion: The results revealed that DAE implants had high survival rates, and no influence of sex, location, shape, diameter, or length on failure rates could be observed. However, a significant association was observed between failure and presence of bone graft in the implant area. Int J Oral Maxillofac Implants 2012;27:1243-1248

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article evaluates the long-term clinical performance of porcelain laminate veneers bonded to teeth prepared with the use of an additive mock-up and aesthetic pre-evaluative temporary (APT) technique over a 12-year period. Sixty-six patients were restored with 580 porcelain laminate veneers. The technique, used for diagnosis, esthetic design, tooth preparation, and provisional restoration fabrication, was based on the APT protocol. The influence of several factors on the durability of veneers was analyzed according to pre- and postoperative parameters. With utilization of the APT restoration, over 80% of tooth preparations were confined to the dental enamel. Over 12 years, 42 laminate veneers failed, but when the preparations were limited to the enamel, the failure rate resulting from debonding and microleakage decreased to 0%. Porcelain laminate veneers presented a successful clinical performance in terms of marginal adaptation, discoloration, gingival recession, secondary caries, postoperative sensitivity, and satisfaction with restoration shade at the end of 12 years. The APT technique facilitated diagnosis, communication, and preparation, providing predictability for the restorative treatment. Limiting the preparation depth to the enamel surface significantly increases the performance of porcelain laminate veneers. (Int J Periodontics Restorative Dent 2012;32:625-635.)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

IceCube, ein Neutrinoteleskop, welches zur Zeit am Südpol aufgebaut und voraussichtlich 2011 fertiggestellt sein wird, kann galaktische Kernkollaps-Supernovae mit hoher Signifikanz und unübertroffener statistischer Genauigkeit der Neutrinolichtkurve detektieren. Derartige Supernovae werden begleitet von einem massiven Ausbruch niederenergetischer Neutrinos aller Flavour. Beim Durchfliegen des Detektormediums Eis entstehen Positronen und Elektronen, welche wiederum lokale Tscherenkowlichtschauer produzieren, die in ihrer Summe das gesamte Eis erleuchten. Ein Nachweis ist somit, trotz der Optimierung IceCubes auf hochenergetische Teilchenspuren, über eine kollektive Rauschratenerhöhung aller optischen Module möglich. Die vorwiegende Reaktion ist der inverse Betazerfall der Antielektronneutrinos, welcher über 90,% des gesamten Signals ausmacht.rnrnDiese Arbeit beschreibt die Implementierung und Funktionsweise der Supernova-Datennahme-Software sowie der Echtzeitanalyse, mit welcher die oben genannte Nachweismethode seit August 2007 realisiert ist. Die Messdaten der ersten zwei Jahre wurden ausgewertet und belegen ein extrem stabiles Verhalten des Detektors insgesamt sowie fast aller Lichtsensoren, die eine gemittelte Ausfallquote von lediglich 0,3,% aufweisen. Eine Simulation der Detektorantwort nach zwei unterschiedlichen Supernova-Modellen ergibt eine Sichtweite IceCubes, die im besten Falle bis zur 51,kpc entfernten Großen Magellanschen Wolke reicht. Leider ist der Detektor nicht in der Lage, die Deleptonisierungsspitze aufzulösen, denn Oszillationen der Neutrinoflavour innerhalb des Sterns modifizieren die Neutrinospektren ungünstig. Jedoch können modellunabhängig anhand des frühesten Signalanstiegs die inverse Massenhierarchie sowie $sin^2 2theta_{13} > 10^{-3}$ etabliert werden, falls die Entfernung zur Supernova $leq$,6,kpc beträgt. Gleiches kann durch Auswertung eines möglichen Einflusses der Erdmaterie auf die Neutrinooszillation mit Hilfe der Messung eines zweiten Neutrinodetektors erreicht werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Im Rahmen der vorliegenden Dissertation wurden 106 Minipins bei 62 Patienten (29 Männer und 33 Frauen)untersucht.rnÜberlebensrate betrug 76,4%. Misserfolge, die zum Verlust der Minipins führten wie Mukositis, Lockerung oder Wurzelperforation, stellten sich in 23,7 % (n=25) der Fälle ein. Dabei gingen beim Auftreten von Mukositis 9 von 14 (8,5 %), bei der Lockerung der Minischrauben 8 von 10 (7,5 %) der Minischrauben verloren. Eine Wurzelperforation trat in einem Fall auf. rnDie einzige lingual im Unterkiefer implantierte Schraube ging verloren. Implantation palatinal im Oberkiefer führte in zwei von vier Fällen zum Verlust. rnDie Sofortbelastung der kieferorthopädischen Kortikalisschrauben erscheint ein praktikables Belastungskonzept zu sein.rnDie Verlustraten bei der vestibulären Implantation betrugen 3,8 % (n=4) für den Oberkiefer und 15,1 % (n=16) für den Unterkiefer.rnBei der Implantation in befestigte bzw. unbefestigte Mukosa betrug die Überlebensrate entsprechend 83,3 % (n=72) und 62,3 % (n=22). rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

L’approccio chirurgico agli adenomi ipofisari ACTH secernenti è la terapia d’elezione nell’uomo. L’ipofisectomia transfenoidale è invece una tecnica poco diffusa in ambito veterinario. La terapia più diffusa nel cane con ipercortisolismo ipofisi dipendente (PDH) è di tipo medico e prevede la somministrazione di farmaci inibitori della sintesi del cortisolo. Gli adenomi ipofisari possono aumentare di volume e determinare una conseguente sintomatologia neurologica; in questi casi le uniche opzioni terapeutiche sono rappresentate dall’asportazione chirurgica della neoplasia e dalla radioterapia. Nella presente tesi vengono descritti 8 interventi di ipofisectomia transfenoidale effettuati su 7 cani con macroadenoma ipofisario presso il Dipartimento di Scienze Mediche Veterinarie dell’Università di Bologna. La difficoltà maggiore per il chirurgo è rappresentata dalla localizzazione della fossa ipofisaria rispetto ai punti di repere visibile in tomografia computerizzata o in risonanza magnetica nucleare, oltre ai problemi di sanguinamento durante la rimozione della neoplasia. Nel periodo post-operatorio maggiori complicazioni si riscontrano in soggetti con adenomi ipofisari di maggiori dimensioni. Al contrario, in presenza di adenomi di dimensioni più contenute, la ripresa post-operatoria risulta più rapida e il tasso di successo maggiore. Al fine di poter eseguire nel cane l’exeresi mirata della sola neoplasia ipofisaria, al pari di quanto avviene nell’uomo, è stato condotto uno studio sulla tomografia computerizzata (TC) in 86 cani con PDH. Il protocollo TC non ha tuttavia permesso di individuare con precisione la posizione della neoplasia per guidare il chirurgo nella sua rimozione. In due casi riportati nel presente lavoro si è verificata una recidiva della neoplasia ipofisaria. In un soggetto si è optato per il reintervento, mentre nell’altro caso per la radioterapia. Entrambe le opzioni hanno garantito una buona qualità di vita per più di un anno dall’intervento terapeutico. Questi casi clinici dimostrano come il reintervento e la radioterapia possano essere considerate valide opzioni in caso di recidiva.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The spinal column performs important functions in the body, including the support of the entire weight of the human body, the ability to orientate the head in space, bending, flexing and rotating the body. Diseases affecting the spine are manifold: the most frequent is scoliosis, which often affects the female population. It is often treated surgically with a very high percentage of failures. The aim of the thesis is to study the role of instrumentation in mechanical failures encountered 12 months after surgery in the treatment of scoliosis. For the purposes of the study, we analyzed specific biomechanical parameters. The pelvic angles determine the position of the pelvis, while the imbalance parameters the structure of the body. We infer other parameters by analyzing the characteristics of the implanted instrumentation. Initially, the anatomy is described of the spine and vertebrae, the equipment used and the possible failures that may occur after surgery. Subsequently, the materials and methods used for the analysis of the above-mentioned parameters for the 61 patients are reported. All data are obtained by the observation of pre and post-operative x-rays with a special program, by reading reports from operators and by medical records. In the fourth chapter, we report the results: the overall failure rate is 60.9%; the types of failures that occurred are rupture of bars and rupture of bars simultaneously to PJK. The most influential parameters on results of the progress of the surgery are the type of material used and the BMI. It is estimated a high percentage of failures in patients treated with implants of cobalt chromium alloys (90.0%). According to the results obtained, it is possible to understand the aspects that in the future should be studied, in order to find a solution to the most frequent surgical failures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to compare the long-term outcomes of implants placed in patients treated for periodontitis periodontally compromised patients (PCP) and in periodontally healthy patients (PHP) in relation to adhesion to supportive periodontal therapy (SPT). MATERIAL AND METHODS: One hundred and twelve partially edentulous patients were consecutively enrolled in private specialist practice and divided into three groups according to their initial periodontal condition: PHP, moderate PCP and severe PCP. Perio and implant treatment was carried out as needed. Solid screws (S), hollow screws (HS) and hollow cylinders (HC) were installed to support fixed prostheses, after successful completion of initial periodontal therapy (full-mouth plaque score <25% and full-mouth bleeding score <25%). At the end of treatment, patients were asked to follow an individualized SPT program. At 10 years, clinical measures and radiographic bone changes were recorded by two calibrated operators, blinded to the initial patient classification. RESULTS: Eleven patients were lost to follow-up. During the period of observation, 18 implants were removed because of biological complications. The implant survival rate was 96.6%, 92.8% and 90% for all implants and 98%, 94.2% and 90% for S-implants only, respectively, for PHP, moderate PCP and severe PCP. The mean bone loss was 0.75 (+/- 0.88) mm in PHP, 1.14 (+/- 1.11) mm in moderate PCP and 0.98 (+/- 1.22) mm in severe PCP, without any statistically significant difference. The percentage of sites, with bone loss > or =3 mm, was, respectively, 4.7% for PHP, 11.2% for moderate PCP and 15.1% for severe PCP, with a statistically significant difference between PHP and severe PCP (P<0.05). Lack of adhesion to SPT was correlated with a higher incidence of bone loss and implant loss. CONCLUSION: Patients with a history of periodontitis presented a lower survival rate and a statistically significantly higher number of sites with peri-implant bone loss. Furthermore, PCP, who did not completely adhere to the SPT, were found to present a higher implant failure rate. This underlines the value of the SPT in enhancing the long-term outcomes of implant therapy, particularly in subjects affected by periodontitis, in order to control reinfection and limit biological complications.