992 resultados para Framework Programmes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of framework design on the fracture resistance of metal-ceramic implant-supported crowns. Screw-retained molar crowns with a screw access hole composed of metal or porcelain were compared to a cement-retained crown (control). For each group (n = 10), five crowns were subjected to dynamic loading (1,200,000 x 100 N x 2 Hz at 37 degrees C). Afterward, all specimens were loaded to failure using a universal testing machine. Significant differences could be established between the cement-and screw-retained groups (P <= .05), but no difference was found between the screw-retained groups and the specimens subjected to dynamic loading. Occlusal discontinuity of screw-retained crowns affects their resistance, and the metallic support on the screw access hole did not reinforce the crowns. Int J Prosthodont 2010;23:350-352.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of core-design modification on the characteristic strength and failure modes of glass-infiltrated alumina (In-Ceram) (ICA) compared with porcelain fused to metal (PFM). Premolar crowns of a standard design (PFMs and ICAs) or with a modified framework design (PFMm and ICAm) were fabricated, cemented on dies, and loaded until failure. The crowns were loaded at 0.5 mm min(-1) using a 6.25 mm tungsten-carbide ball at the central fossa. Fracture load values were recorded and fracture analysis of representative samples were evaluated using scanning electron microscopy. Probability Weibull curves with two-sided 90% confidence limits were calculated for each group and a contour plot of the characteristic strength was obtained. Design modification showed an increase in the characteristic strength of the PFMm and ICAm groups, with PFM groups showing higher characteristic strength than ICA groups. The PFMm group showed the highest characteristic strength among all groups. Fracture modes of PFMs and of PFMm frequently reached the core interface at the lingual cusp, whereas ICA exhibited bulk fracture through the alumina core. Core-design modification significantly improved the characteristic strength for PFM and for ICA. The PFM groups demonstrated higher characteristic strength than both ICA groups combined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper develops a general framework for valuing a wide range of derivative securities. Rather than focusing on the stochastic process of the underlying security and developing an instantaneously-riskless hedge portfolio, we focus on the terminal distribution of the underlying security. This enables the derivative security to be valued as the weighted sum of a number of component pieces. The component pieces are simply the different payoffs that the security generates in different states of the world, and they are weighted by the probability of the particular state of the world occurring. A full set of derivations is provided. To illustrate its use, the valuation framework is applied to plain-vanilla call and put options, as well as a range of derivatives including caps, floors, collars, supershares, and digital options.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent reviews of the desistance literature have advocated studying desistance as a process, yet current empirical methods continue to measure desistance as a discrete state. In this paper, we propose a framework for empirical research that recognizes desistance as a developmental process. This approach focuses on changes in the offending rare rather than on offending itself We describe a statistical model to implement this approach and provide an empirical example. We conclude with several suggestions for future research endeavors that arise from our conceptualization of desistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the effectiveness of two generalized visual training programmes in enhancing visual and motor performance for racquet sports. Forty young participants were assigned equally to groups undertaking visual training using Revien and Gabor's Sports Vision programme (Group 1), visual training using Revien's Eyerobics (Group 2), a placebo condition involving reading (Group 3) and a control condition involving physical practice only (Group 4). Measures of basic visual function and of sport-specific motor performance were obtained from all participants before and immediately after a 4-week training period. Significant pre- to post-training differences were evident on some of the measures; however, these were not group-dependent. Contrary to the claims made by proponents of generalized visual training, we found no evidence that the visual training programmes led to improvements in either vision or motor performance above and beyond those resulting simply from test familiarity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tobacco cessation after acute myocardial infarction (AMI) substantially improves outcome but how effective individual programmes are needs to be established. To date, few studies have examined this factor. Aims: To assess the outcome of two smoking cessation programmes after AMI. Methods: One hundred and ninety-eight current smokers admitted to coronary care with an AMI participated in a randomized controlled study comparing two outpatient tobacco interventions, the Stanford Heart Attack Staying Free (SF) programme and a Usual Care (UC) programme. Results: Log-rank analyses revealed that patients in the SF programme were retained longer (P < 0.001) and had higher cotinine validated abstinence rates (P < 0.001) compared with patients in the UC programme. Twelve months after intervention, 39% of the SF programme compared with 2% of the UC programme demonstrated cotinine validated tobacco cessation, representing a significant reduced relapse rate in the SF programme (chi (2), P < 0.001). Conclusions: The SF smoking cessation programme initiated in hospital can significantly reduce smoking rates at 12 months after myocardial infarction. Although superior to the UC quit programme, Australian outcomes were lower than the American programme originators' published outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A national survey of mental health telemedicine programmes was conducted and data collected on their catchment areas, organizational structure, equipment, clinical and non-clinical activity, and use by populations who traditionally have been poorly served by mental health services in Australia. Of 25 programmes surveyed, information was obtained for 23. Sixteen programmes had dealt with a total of 526 clients during the preceding three months. Of these, 397 (75%) were resident in rural or remote locations at the time of consultation. Thirty-seven (7%) were Aboriginals or Torres Strait Islanders. Only 19 (4%) were migrants from non-English-speaking backgrounds. The programmes provided both direct clinical and secondary support services. Overall, the number of videoconferencing sessions devoted to clinical activity was low, the average being 123 sessions of direct clinical care per programme per year. Videoconferencing was also used for professional education, peer support., professional supervision, administration and linking families. The results of the study suggest that telehealth can increase access to mental health services for people in rural and remote areas, particularly those who have hitherto been poorly served by mental health services in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Australian academics and practitioners in the human services are particularly susceptible to social, political and economic influences in respect of their relevance, viability and operations. In fact, it can be argued that the impact of these influences has placed human service practitioners and academics in a perpetual state of vulnerability. Australian universities have been challenged to make their programmes more relevant and viable to the community at large, and practitioners face increasing workloads with limited resources based on restricted fiscal allocation, and the changing relationship between government and service providers. Drawing on interview data from twenty-one (n = 21) practitioners, this article highlights their identified problems regarding the notion of professionalism in the human services with a particular focus on ethical dilemmas in human service practice. Gleaning these details will be a basis for recommending necessary professionalethics curricula content in human services programmes offered in Australian universities. Moreover, while the research data is Australian based, the authors contend that the universal theories and principles underpinning human service practice justify the significance and value of the data as an important source for international consideration in curriculum development of human service academic programmes.