995 resultados para Fracture Injuries.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to clarify the relationship between the mechanical environment at the fracture site and endogenous fibroblast growth factor-2 (FGF-2). We compared two types of fracture healing with different callus formations and cellular events using MouseFix(TM) plate fixation systems for murine fracture models. Left femoral fractures were induced in 72 ten-week-old mice and then fixed with a flexible (Group F) or rigid (Group R) Mouse Fix(TM) plate. Mice were sacrificed on days 3, 5, 7, 10, 14, and 21. The callus volumes were measured by 3D micro-CT and tissues were histologically stained with hematoxylin & eosin or safranin-O. Sections from days 3, 5, and 7 were immunostained for FGF-2 and Proliferating Cell Nuclear Antigen (PCNA). The callus in Group F was significantly larger than that in Group R. The rigid plate allowed bone union without a marked external callus or chondrogenesis. The flexible plate formed a large external callus as a result of endochondral ossification. Fibroblastic cells in the granulation tissue on days 5 and 7 in Group F showed marked FGF-2 expression compared with Group R. Fibroblastic cells showed ongoing proliferation in granulation tissue in group F, as indicated by PCNA expression, which explained the relative granulation tissue increase in group F. There were major differences in early phase endogenous FGF-2 expression between these two fracture healing processes, due to different mechanical environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Virtual methods to assess the fitting of a fracture fixation plate were proposed recently, however with limitations such as simplified fit criteria or manual data processing. This study aims to automate a fit analysis procedure using clinical-based criteria, and then to analyse the results further for borderline fit cases. Three dimensional (3D) models of 45 bones and of a precontoured distal tibial plate were utilized to assess the fitting of the plate automatically. A Matlab program was developed to automatically measure the shortest distance between the bone and the plate at three regions of interest and a plate-bone angle. The measured values including the fit assessment results were recorded in a spreadsheet as part of the batch-process routine. An automated fit analysis procedure will enable the processing of larger bone datasets in a significantly shorter time, which will provide more representative data of the target population for plate shape design and validation. As a result, better fitting plates can be manufactured and made available to surgeons, thereby reducing the risk and cost associated with complications or corrective procedures. This in turn, is expected to translate into improving patients' quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: Parliamentary committees established in Westminster parliaments, such as Queensland, provide a cross-party structure that enables them to recommend policy and legislative changes that may otherwise be difficult for one party to recommend. The overall parliamentary committee process tends to be more cooperative and less adversarial than the main chamber of parliament and, as a result, this process permits parliamentary committees to make recommendations more on the available research evidence and less on political or party considerations. Objectives: This paper considers the contributions that parliamentary committees in Queensland have made in the past in the areas of road safety, drug use as well as organ and tissue donation. The paper also discusses the importance of researchers actively engaging with parliamentary committees to ensure the best evidence based policy outcomes. Key messages: In the past, parliamentary committees have successfully facilitated important safety changes with many committee recommendations based on research results. In order to maximise the benefits of the parliamentary committee process it is essential that researchers inform committees about their work and become key stakeholders in the inquiry process. Researchers can keep committees informed by making submissions to their inquiries, responding to requests for information and appearing as witnesses at public hearings. Researchers should emphasise the key findings and implications of their research as well as considering the jurisdictional implications and political consequences. It is important that researchers understand the differences between lobbying and providing informed recommendations when interacting with committees. Discussion and conclusions: Parliamentary committees in Queensland have successfully assisted in the introduction of evidence based policy and legislation. In order to present best practice recommendations, committees rely on the evidence presented to them including the results of researchers. Actively engaging with parliamentary committees will help researchers to turn their results into practice with a corresponding decrease in injuries and fatalities. Developing an understanding of parliamentary committees, and the typical inquiry process used by these committees, will help researchers to present their research results in a manner that will encourage the adoption of their ideas by parliamentary committees, the presentation of these results as recommendations within the report and the subsequent enactment of the committee’s recommendations by the government.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hamstring strain injuries (HSIs) are common in a number of sports and incidence rates have not declined in recent times. Additionally, the high rate of recurrent injuries suggests that our current understanding of HSI and re-injury risk is incomplete. Whilst the multifactoral nature of HSIs is agreed upon by many, often individual risk factors and/or causes of injury are examined in isolation. This review aims to bring together the causes, risk factors and interventions associated with HSIs to better understand why HSIs are so prevalent. Running is often identified as the primary activity type for HSIs and given the high eccentric forces and moderate muscle strain placed on the hamstrings during running these factors are considered to be part of the aetiology of HSIs. However, the exact causes of HSIs remain unknown and whilst eccentric contraction and muscle strain purportedly play a role, accumulated muscle damage and/or a single injurious event may also contribute. Potentially, all of these factors interact to varying degrees depending on the injurious activity type (i.e. running, kicking). Furthermore, anatomical factors, such as the biarticular organization, the dual innervations of biceps femoris (BF), fibre type distribution, muscle architecture and the degree of anterior pelvic tilt, have all been implicated. Each of these variables impact upon HSI risk via a number of different mechanisms that include increasing hamstring muscle strain and altering the susceptibility of the hamstrings to muscle damage. Reported risk factors for HSIs include age, previous injury, ethnicity, strength imbalances, flexibility and fatigue. Of these, little is known, definitively, about why previous injury increases the risk of future HSIs. Nevertheless, interventions put in place to reduce the incidence of HSIs by addressing modifiable risk factors have focused primarily on increasing eccentric strength, correcting strength imbalances and improving flexibility. The response to these intervention programmes has been mixed with varied levels of success reported. A conceptual framework is presented suggesting that neuromuscular inhibition following HSIs may impede the rehabilitation process and subsequently lead to maladaptation of hamstring muscle structure and function, including preferentially eccentric weakness, atrophy of the previously injured muscles and alterations in the angle of peak knee flexor torque. This remains an area for future research and practitioners need to remain aware of the multifactoral nature of HSIs if injury rates are to decline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report is an update of an earlier one produced in January 2010 (see Carrington et al. 2010) which remains as an ePrint through the project’s home page. This report focuses on our examination of extant data which have been sourced with respect to unintentional serious and violent harm, including injuries, to males living in regional and remote Australia . and which were available in public data bases at production. Such harm typically might be caused by, for example, transport accidents, occupational exposures and hazards, burns and so on. Thus unintentional violent harm can cause physical trauma the consequences of which can lead to chronic conditions including psychological harm or substance abuse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Newson v Aust Scan Pty Ltd t/a Ikea Springwood [2010] QSC 223 the Supreme Court examined the discretion under s 32(2) of the Personal Injuries Proceedings Act 2002 (Qld), to permit a document which has not been disclosed as required by the pre-court procedures under the PIPA to be used in a subsequent court proceeding. This appears to be the first time that the nature and parameters of the discretion have been judicially considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of governments on increasing active travel has motivated renewed interest in cycling safety. Bicyclists are up to 20 times more likely to be involved in serious injury crashes than drivers so understanding the relationship among factors in bicyclist crash risk is critically important for identifying effective policy tools, for informing bicycle infrastructure investments, and for identifying high risk bicycling contexts. This study aims to better understand the complex relationships between bicyclist self reported injuries resulting from crashes (e.g. hitting a car) and non-crashes (e.g. spraining an ankle) and perceived risk of cycling as a function of cyclist exposure, rider conspicuity, riding environment, rider risk aversion, and rider ability. Self reported data from 2,500 Queensland cyclists are used to estimate a series of seemingly unrelated regressions to examine the relationships among factors. The major findings suggest that perceived risk does not appear to influence injury rates, nor do injury rates influence perceived risks of cycling. Riders who perceive cycling as risky tend not to be commuters, do not engage in group riding, tend to always wear mandatory helmets and front lights, and lower their perception of risk by increasing days per week of riding and by increasing riding proportion on bicycle paths. Riders who always wear helmets have lower crash injury risk. Increasing the number of days per week riding tends to decrease both crash injury and non crash injury risk (e.g. a sprain). Further work is needed to replicate some of the findings in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Government promotion of active transport has renewed interest in cycling safety. Research has shown that bicyclists are up to 20 times more likely to be involved in serious injury crashes than drivers. On-road cycling injuries are under-reported in police data, and many non-serious injuries are not recorded in any official database. This study aims to explore the relationships between rider characteristics and environmental factors that influence per kilometre risk of bicycle-related crash and non-crash injuries. Method A survey of 2,532 Queensland adults who had ridden at least once in the past year was conducted from October 2009 to March 2010, with most responses received online (99.3%). Riders were asked where they rode (footpath, bike path, road etc.), average travel speed, purpose of riding, type of bike ridden, how far and how often they rode in. Measures of rider experience, skill, safety perceptions, safety behaviours, crash involvement and demographic characteristics were also collected. RESULTS Increasing exposure and having more expensive bicycles were shown to reduce the risk per km of crash and non-crash injury rates, and to reduce perceived risk. Never wearing bright coloured clothing related to increased crash risk, use of fluorescent and reflective clothing had no effect on crash risk. Riding in low-speed environments, never using a front light, and riding in low-speed environments were associated with reduced non-crash injury risk. Perceived risk was influenced by exposure, use of conspicuity aids and helmets, riding for utilitarian reasons, and group-riding behaviours. DISCUSSION Perceived risk does not appear to influence injury rates and injury rates do not appear to influence the perceived risk of cycling. Riders who perceive cycling to be risky tend not to be commuters, do not engage in group riding and always wear helmets. Not all measures of conspicuity were associated with risk, with rear lights found to have no relationship to injury. The risks of experiencing a crash or non-crash injury were similar, therefore injury prevention strategies should expand their scope to include other factors such as the importance of bicycle set-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compound pelvic fractures are deemed to be one of the most severe orthopaedic injuries with an extremely high morbidity and mortality. After the initial resuscitation phase the prevention of pelvic sepsis is one of the main treatment goals for patients with an open pelvic fracture. If there is a suspicion of a rectal injury or if the wounds are in the perineal area, The Princess Alexandra Hospital's management plan includes early faecal diversion combined with vigorous soft tissue debridement, VAC(®) therapy and (if indicated) external fixation of the pelvic fracture. We present our flowchart for the treatment of trauma patients with compound pelvic fractures illustrated by a case report describing a 32 year old patient who sustained an open pelvic ring injury in a workplace accident. The aim of this paper is to underline the importance of a safe, straightforward approach to compound pelvic fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone’s capacity to repair following trauma is both unique and astounding. However, fractures sometimes fail to heal. Hence, the goal of fracture treatment is the restoration of bone’s structure, composition and function. Fracture fixation devices should provide a favourable mechanical and biological environment for healing to occur. The use of internal fixation is increasing as these devices may be applied with less invasive techniques. Recent studies suggest however that, internal fixation devices may be overly stiff and suppresses callus formation. The degree of mechanical stability influences the healing outcome. This is determined by the stiffness of the fixation device and the degree of limb loading. This project aims to characterise the fixation stability of an internal plate fixation device and the influence of modifications to its configuration on implant stability. As there are no standardised methods for the determination of fixation stiffness, the first part of this project aims to compares different methodologies and determines the most appropriate method to characterise the stiffness of internal plate fixators. The stiffness of a fixation device also influences the physiological loads experienced by the healing bone. Since bone adapts to this applied load by undergoing changes through a remodelling process, undesirable changes could occur during the period of treatment with an implant. The second part of this project aims to develop a methodology to quantify remodelling changes. This quantification is expected to aid our understanding of the changes in pattern due to implant related remodelling and on the factors driving the remodelling process. Knowledge gained in this project is useful to understand how the configuration of internal fixation devices can promote timely healing and prevent undesirable bone loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanically well-defined stabilization systems have only recently become available, providing standardized conditions for studying the role of the mechanical environment on mouse bone fracture healing. The aim of this study was to characterize the time course of strength recovery and callus development of mouse femoral osteotomies stabilized with either low or high flexibility (in bending and torsion) internal fixation plates. Animals were euthanized and femora excised at 14, 21, and 28 days post-osteotomy for microCT analysis and torsional strength testing. While a larger mineralized callus was observed in osteotomies under more flexible conditions at all time points, the earlier bridging of the mineralized callus under less flexible conditions by 1 week resulted in an earlier recovery of torsional strength in mice stabilized with low flexibility fixation. Ultimate torque values for these bones were significantly higher at 14 and 21 days post-osteotomy compared to bones with the more flexible stabilization. Our study confirms the high reproducibility of the results that are achieved with this new implant system, therefore making it ideal for studying the influence of the mechanical environment on murine fracture healing under highly standardized conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Woolworths Ltd v Graham [2007] QDC 301 Searles DCJ struck out a pre-proceedings application under the Personal Injuries Proceedings Act 2002 (Qld)on the basis that the material before the Court was not sufficient to attract the jurisdiction of the District Court.The decision serves more broadly as a reminder that the District Court is an inferior court of defined and limited jurisdiction and that any proceedings brought in it must be demonstrably within the jurisdiction conferred on that court by legislation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The finite element (FE) analysis is an effective method to study the strength and predict the fracture risk of endodontically-treated teeth. This paper presents a rapid method developed to generate a comprehensive tooth FE model using data retrieved from micro-computed tomography (μCT). With this method, the inhomogeneity of material properties of teeth was included into the model without dividing the tooth model into different regions. The material properties of the tooth were assumed to be related to the mineral density. The fracture risk at different tooth portions was assessed for root canal treatments. The micro-CT images of a tooth were processed by a Matlab software programme and the CT numbers were retrieved. The tooth contours were obtained with thresholding segmentation using Amira. The inner and outer surfaces of the tooth were imported into Solidworks and a three-dimensional (3D) tooth model was constructed. An assembly of the tooth model with the periodontal ligament (PDL) layer and surrounding bone was imported into ABAQUS. The material properties of the tooth were calculated from the retrieved CT numbers via ABAQUS user's subroutines. Three root canal geometries (original and two enlargements) were investigated. The proposed method in this study can generate detailed 3D finite element models of a tooth with different root canal enlargements and filling materials, and would be very useful for the assessment of the fracture risk at different tooth portions after root canal treatments.