843 resultados para Feature evaluation and selection
Resumo:
Ozone due to having low half-life and devoid of environmental harmful effects is recognized as one of the most effective disinfectant and fungicide in aquaculture. The objective of this study is to consider the effects of periodicay ozonation, hydrogen peroxide treatment, and physical treatment capability in hatching rate enhancement. Three concentrations of 0.05, 0.1 and 0.15 ppm ozone (10 min) and peroxide hydrogen with dose of 500 and 1000 ppm in two procedures accompanied with physical treatment and without physical treatment were examined on hatching rate. In the first year, Egg ozonation (0.1 ppm) with physical treatment have been resulted the greatest hatching rate (81.4%). In the second year, egg treatment with 1000 ppm hydrogen peroxide with physical treatment have been showed the greatest hatching rate (78%). Average hatching rate for the blank control treatment (without disinfectin and physical treatment) was 32.7%. From the economic viewpoint, 0.05 ppm ozone with physical treatment, due to considerable minimizing at consumption energy and ozonation system retention costs, indicated as the best treatment than other ozone treatments for fungal control. Very low correlation (r=-0.14) have been observed between hatchery water temperature and fungal infection percentage in control treatment.
Resumo:
The Statistics Anxiety Rating Scale (STARS) was adapted into German to examine its psychometric properties (n = 400). Two validation studies (n = 66, n = 96) were conducted to examine its criterion-related validity. The psychometric properties of the questionnaire were very similar to those previously reported for the original English version in various countries and other language versions. Confirmatory factor analysis indicated 2 second-order factors: One was more closely related to anxiety and the other was more closely related to negative attitudes toward statistics. Predictive validity of the STARS was shown both in an experimental exam-like situation in the laboratory and during a real examination situation. Taken together, the findings indicate that statistics anxiety as assessed by the STARS is a useful construct that is more than just an expression of a more general disposition to anxiety.
Resumo:
In this study, TiN/La 2O 3/HfSiON/SiO 2/Si gate stacks with thick high-k (HK) and thick pedestal oxide were used. Samples were annealed at different temperatures and times in order to characterize in detail the interaction mechanisms between La and the gate stack layers. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) measurements performed on these samples show a time diffusion saturation of La in the high-k insulator, indicating an La front immobilization due to LaSiO formation at the high-k/interfacial layer. Based on the SIMS data, a technology computer aided design (TCAD) diffusion model including La time diffusion saturation effect was developed. © 2012 American Institute of Physics.
Resumo:
The past decade has seen a rise of interest in Laplacian eigenmaps (LEMs) for nonlinear dimensionality reduction. LEMs have been used in spectral clustering, in semisupervised learning, and for providing efficient state representations for reinforcement learning. Here, we show that LEMs are closely related to slow feature analysis (SFA), a biologically inspired, unsupervised learning algorithm originally designed for learning invariant visual representations. We show that SFA can be interpreted as a function approximation of LEMs, where the topological neighborhoods required for LEMs are implicitly defined by the temporal structure of the data. Based on this relation, we propose a generalization of SFA to arbitrary neighborhood relations and demonstrate its applicability for spectral clustering. Finally, we review previous work with the goal of providing a unifying view on SFA and LEMs. © 2011 Massachusetts Institute of Technology.
Resumo:
In recent years, the healthcare sector has adopted the use of operational risk assessment tools to help understand the systems issues that lead to patient safety incidents. But although these problem-focused tools have improved the ability of healthcare organizations to identify hazards, they have not translated into measurable improvements in patient safety. One possible reason for this is a lack of support for the solution-focused process of risk control. This article describes a content analysis of the risk management strategies, policies, and procedures at all acute (i.e., hospital), mental health, and ambulance trusts (health service organizations) in the East of England area of the British National Health Service. The primary goal was to determine what organizational-level guidance exists to support risk control practice. A secondary goal was to examine the risk evaluation guidance provided by these trusts. With regard to risk control, we found an almost complete lack of useful guidance to promote good practice. With regard to risk evaluation, the trusts relied exclusively on risk matrices. A number of weaknesses were found in the use of this tool, especially related to the guidance for scoring an event's likelihood. We make a number of recommendations to address these concerns. The guidance assessed provides insufficient support for risk control and risk evaluation. This may present a significant barrier to the success of risk management approaches in improving patient safety. © 2013 Society for Risk Analysis.
Evaluation and application of micro-sampling system for inductively coupled plasma mass spectrometry
Resumo:
Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.
Resumo:
The article considers the arguments that have been made in defence of social media screening as well as issues that arise and may effectively erode the reliability and utility of such data for employers. First, the authors consider existing legal frameworks and guidelines that exist in the UK and the USA, as well as the subsequent ethical concerns that arise when employers access and use social networking content for employment purposes. Second, several arguments in favour of the use of social networking content are made, each of which is considered from several angles, including concerns about impression management, bias and discrimination, data protection and security. Ultimately, the current state of knowledge does not provide a definite answer as to whether information from social networks is helpful in recruitment and selection.
Resumo:
Yeoman, A. J., Cooper, J. M., Urquhart, C. J. & Tyler, A. (2003). The management of health library outreach services: evaluation and reflection on lessons learned on the VIVOS project. Journal of the Medical Library Association, 91(4), 426-433. Sponsorship: Resource
Resumo:
T.Boongoen and Q. Shen. Semi-Supervised OWA Aggregation for Link-Based Similarity Evaluation and Alias Detection. Proceedings of the 18th International Conference on Fuzzy Systems (FUZZ-IEEE'09), pp. 288-293, 2009. Sponsorship: EPSRC
Resumo:
Facial features play an important role in expressing grammatical information in signed languages, including American Sign Language(ASL). Gestures such as raising or furrowing the eyebrows are key indicators of constructions such as yes-no questions. Periodic head movements (nods and shakes) are also an essential part of the expression of syntactic information, such as negation (associated with a side-to-side headshake). Therefore, identification of these facial gestures is essential to sign language recognition. One problem with detection of such grammatical indicators is occlusion recovery. If the signer's hand blocks his/her eyebrows during production of a sign, it becomes difficult to track the eyebrows. We have developed a system to detect such grammatical markers in ASL that recovers promptly from occlusion. Our system detects and tracks evolving templates of facial features, which are based on an anthropometric face model, and interprets the geometric relationships of these templates to identify grammatical markers. It was tested on a variety of ASL sentences signed by various Deaf native signers and detected facial gestures used to express grammatical information, such as raised and furrowed eyebrows as well as headshakes.