994 resultados para Fast neutrons.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The resistivity of two types of lithium fast-ion conductors, Li16-2xZnx(GeO4)4 (x=1,2) and Li3+xGexV1-xO4 (x=0.25,0.6,0.72), showed pronounced maxima as a function of pressure. For the first type, ln(ρ / ρ0) peaked at values of 0.12 (x=1) and 0.35 (x=2) near 20 kbar and decreased thereafter up to 80 kbar. Thermal activation energies and prefactors also showed corresponding maxima. For the second type, ln(ρ / ρ0) increased to 3-4 between 20 and 32 kbar. Near 80 kbar, ρ decreased (for x=0.25) by a factor of 250. The results are interpreted in terms of negative activation volumes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There’s a polyester mullet skirt gracing a derrière near you. It’s short at the front, long at the back, and it’s also known as the hi-lo skirt. Like fads that preceded it, the mullet skirt has a short fashion life, and although it will remain potentially wearable for years, it’s likely to soon be heading to the charity shop or to landfill...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method of sensing the abnormal output voltage conditions of a single phase UPS system is presented, which provides the information almost instantaneously, so that a fast load transfer can be initiated. A continuous monitoring of the UPS output instantaneous voltage is used so that any under/over voltage, transients, or waveform distortion present can be detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper describes a Simultaneous Implicit (SI) approach for transient stability simulations based on an iterative technique using traingularised admittance matrix [1]. The reduced saliency of generator in the subtransient state is taken advantage of to speed up the algorithm. Accordingly, generator differential equations, except rotor swing, contain voltage proportional to fluxes in the main field, dampers and a hypothetical winding representing deep flowing eddy currents, as state variables. The simulation results are validated by comparison with two independent methods viz. Runge-Kutta simulation for a simplified system and a method based on modelling damper windings using conventional induction motor theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Review of Stuart Coupe's biography of Australian music legend Michael Gudinski.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of erroneous genotypes having passed standard quality control (QC) can be severe in genome-wide association studies, genotype imputation, and estimation of heritability and prediction of genetic risk based on single nucleotide polymorphisms (SNP). To detect such genotyping errors, a simple two-locus QC method, based on the difference in test statistic of association between single SNPs and pairs of SNPs, was developed and applied. The proposed approach could detect many problematic SNPs with statistical significance even when standard single SNP QC analyses fail to detect them in real data. Depending on the data set used, the number of erroneous SNPs that were not filtered out by standard single SNP QC but detected by the proposed approach varied from a few hundred to thousands. Using simulated data, it was shown that the proposed method was powerful and performed better than other tested existing methods. The power of the proposed approach to detect erroneous genotypes was approximately 80% for a 3% error rate per SNP. This novel QC approach is easy to implement and computationally efficient, and can lead to a better quality of genotypes for subsequent genotype-phenotype investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New algorithms for the continuous wavelet transform are developed that are easy to apply, each consisting of a single-pass finite impulse response (FIR) filter, and several times faster than the fastest existing algorithms. The single-pass filter, named WT-FIR-1, is made possible by applying constraint equations to least-squares estimation of filter coefficients, which removes the need for separate low-pass and high-pass filters. Non-dyadic two-scale relations are developed and it is shown that filters based on them can work more efficiently than dyadic ones. Example applications to the Mexican hat wavelet are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Web data can often be represented in free tree form; however, free tree mining methods seldom exist. In this paper, a computationally fast algorithm FreeS is presented to discover all frequently occurring free subtrees in a database of labelled free trees. FreeS is designed using an optimal canonical form, BOCF that can uniquely represent free trees even during the presence of isomorphism. To avoid enumeration of false positive candidates, it utilises the enumeration approach based on a tree-structure guided scheme. This paper presents lemmas that introduce conditions to conform the generation of free tree candidates during enumeration. Empirical study using both real and synthetic datasets shows that FreeS is scalable and significantly outperforms (i.e. few orders of magnitude faster than) the state-of-the-art frequent free tree mining algorithms, HybridTreeMiner and FreeTreeMiner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative studies on protein structures form an integral part of protein crystallography. Here, a fast method of comparing protein structures is presented. Protein structures are represented as a set of secondary structural elements. The method also provides information regarding preferred packing arrangements and evolutionary dynamics of secondary structural elements. This information is not easily obtained from previous methods. In contrast to those methods, the present one can be used only for proteins with some secondary structure. The method is illustrated with globin folds, cytochromes and dehydrogenases as examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transforms dealt with in this paper are defined in terms of the transform kernels which are Kroneeker products of the two or more component kernels. The signal flow-graph for the computation of such a transform is obtained with the flow-graphs for the component transforms as building blocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although they made up a significant share of the retail music market from the 60s to the 90s, and were often used as promotional and marketing tools, cassettes became re-configured in the 80s as an integral component of cassette magazines. Binding sound, music, talk, text, visual art and design, they were a truly innovative interdisciplinary form. This paper explores the history of these artefacts with particular emphasis on the Brisbane underground music scene of the late 70s and 80s, and discusses their significance in as a bridge between the music scene and art scenes of this period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual tracking has been a challenging problem in computer vision over the decades. The applications of Visual Tracking are far-reaching, ranging from surveillance and monitoring to smart rooms. Mean-shift (MS) tracker, which gained more attention recently, is known for tracking objects in a cluttered environment and its low computational complexity. The major problem encountered in histogram-based MS is its inability to track rapidly moving objects. In order to track fast moving objects, we propose a new robust mean-shift tracker that uses both spatial similarity measure and color histogram-based similarity measure. The inability of MS tracker to handle large displacements is circumvented by the spatial similarity-based tracking module, which lacks robustness to object's appearance change. The performance of the proposed tracker is better than the individual trackers for tracking fast-moving objects with better accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By detecting leading protons produced in the Central Exclusive Diffractive process, p+p → p+X+p, one can measure the missing mass, and scan for possible new particle states such as the Higgs boson. This process augments - in a model independent way - the standard methods for new particle searches at the Large Hadron Collider (LHC) and will allow detailed analyses of the produced central system, such as the spin-parity properties of the Higgs boson. The exclusive central diffractive process makes possible precision studies of gluons at the LHC and complements the physics scenarios foreseen at the next e+e− linear collider. This thesis first presents the conclusions of the first systematic analysis of the expected precision measurement of the leading proton momentum and the accuracy of the reconstructed missing mass. In this initial analysis, the scattered protons are tracked along the LHC beam line and the uncertainties expected in beam transport and detection of the scattered leading protons are accounted for. The main focus of the thesis is in developing the necessary radiation hard precision detector technology for coping with the extremely demanding experimental environment of the LHC. This will be achieved by using a 3D silicon detector design, which in addition to the radiation hardness of up to 5×10^15 neutrons/cm2, offers properties such as a high signal-to- noise ratio, fast signal response to radiation and sensitivity close to the very edge of the detector. This work reports on the development of a novel semi-3D detector design that simplifies the 3D fabrication process, but conserves the necessary properties of the 3D detector design required in the LHC and in other imaging applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose different components. Dosimetry is important as the effect of the radiation on the tissue is correlated with the radiation dose. Consistent and reliable radiation dose delivery and dosimetry are thus basic requirements for radiotherapy. The international recommendations for are not directly applicable to BNCT dosimetry. The existing dosimetry guidance for BNCT provides recommendations but also calls for investigating for complementary methods for comparison and improved accuracy. In this thesis the quality assurance and stability measurements of the neutron beam monitors used in dose delivery are presented. The beam monitors were found not to be affected by the presence of a phantom in the beam and that the effect of the reactor core power distribution was less than 1%. The weekly stability test with activation detectors has been generally reproducible within the recommended tolerance value of 2%. An established toolkit for epithermal neutron beams for determination of the dose components is presented and applied in an international dosimetric intercomparison. The measured quantities (neutron flux, fast neutron and photon dose) by the groups in the intercomparison were generally in agreement within the stated uncertainties. However, the uncertainties were large, ranging from 3-30% (1 standard deviation), emphasising the importance of dosimetric intercomparisons if clinical data is to be compared between different centers. Measurements with the Exradin type 2M ionisation chamber have been repeated in the epithermal neutron beam in the same measurement configuration over the course of 10 years. The presented results exclude severe sensitivity changes to thermal neutrons that have been reported for this type of chamber. Microdosimetry and polymer gel dosimetry as complementary methods for epithermal neutron beam dosimetry are studied. For microdosimetry the comparison of results with ionisation chambers and computer simulation showed that the photon dose measured with microdosimetry was lower than with the two other methods. The disagreement was within the uncertainties. For neutron dose the simulation and microdosimetry results agreed within 10% while the ionisation chamber technique gave 10-30% lower neutron dose rates than the two other methods. The response of the BANG-3 gel was found to be linear for both photon and epithermal neutron beam irradiation. The dose distribution normalised to dose maximum measured by MAGIC polymer gel was found to agree well with the simulated result near the dose maximum while the spatial difference between measured and simulated 30% isodose line was more than 1 cm. In both the BANG-3 and MAGIC gel studies, the interpretation of the results was complicated by the presence of high-LET radiation.