Resumo:
Buildings are one of the major consumers of energy in Europe. This makes them an important target when aiming to reduce the energy consumptions and carbon emissions. The majority of the European building stock has already some decades and so it needs renovation in order to keep its functionality. Taking advantage of these interventions, the energy performance of the buildings may also be improved. In Portugal the renovation techniques, both regarding energy efficiency measures as well as measures for the use of renewable energy sources, are normally planned at the building scale. It is important to explore the possibility of having large scale interventions, has it has been done in other countries, namely at neighbourhood scale with district energy system in order to optimize the results in terms of costs and environmental impact.
Resumo:
Recently, environmental architecture and sustainable construction has been ranked on top of the worldâ s interests. Making use of natural resources helps in reducing energy consumption and costs associated with the operation of buildings. The current architectural approaches and designs in Palestine are far away from environmental concepts, copying and simulating abroad approaches, without taking into account the culture, climate, and inhabitant's needs. On the contrast, vernacular architecture has achieved environmental concepts and has given suitable approaches and samples - without any need to simulate or copy - which come from people and land. This paper discusses how the Palestinian socio-cultural context shaped the residential vernacular architecture in Palestine, taking the old city of Nablus as a case-study. The research concept depends on analysing and trying to understand the effect of the socio-cultural context on vernacular architecture and trying to reach some rules or understandings of how it works in order to reach a modern environmental dwelling that is suitable to this concept. The research method goes through analysing study cases from the traditional architecture models and the Nablus city is selected as a case study. This analytical and qualitative method can lead to deep understanding for how to benefit from vernacular architecture in Palestine in finding the future environmental residential construction. One of the main findings of this research is to set general and special rules for building sustainable buildings in Palestine from the socio-cultural point view, in order to be a reference for designers, stakeholders, ministry of planning, and municipalities.
Resumo:
Dissertação de International Master in Sustainable Built Environment
Resumo:
The evolution of the construction caused a need to use more effective equipments, capable of meeting the increasingly demanding deadlines for the completion of works. In this context, the safety and efficiency of equipment have become key aspects in order to optimize the execution time of the works, as well as reducing labor costs and loss of materials. With the evolution of construction and construction processes, cranes have come to represent a signal of the construction of buildings, revealing to be, in most of the cases, the main equipment of construction sites. Currently, some engineers revels some apprehension regarding the use and handling of cranes which is natural and acceptable, since an equipment failure can lead to serious or fatal accidents. The factors affecting safety management of the cranes in construction sites were investigated, identified, classified and evaluated according to their degree of importance, through interviews with representatives of the general contractors of a set of selected construction sites.
Resumo:
BACKGROUND: Environmental conditions play a crucial role in mite growth, and optimal environmental control is key in the prevention of airway inflammation in chronic allergic rhinoconjunctivitis or asthma. OBJECTIVE: To evaluate the relationship between building energy performance and indoor mite allergen concentration in a cross-sectional study. METHODS: Major allergen concentration (Der f 1, Der p 1, mite group 2, Fel d 1 and Bla g 2) was determined by quantitative dot blot analysis from mattress and carpet dust samples in five buildings designed for low energy use (LEB) and in six control buildings (CB). Inhabitants had received 4 weeks prior to mite measurement a personal validated questionnaire related to the perceived state of health and comfort of living. RESULTS: Cumulative mite allergen concentration (with Der f 1 as the major contributor) was significantly lower in LEB as compared with CB both in mattresses and in carpets. In contrast, the two categories of buildings did not differ in Bla g 2 and Fel d 1 concentration, in the amount of dust and airborne mould collected. Whereas temperature was higher in LEB, relative humidity was significantly lower than in CB. Perceived overall comfort was better in LEB. CONCLUSIONS: Major mite allergen Der f 1 preferentially accumulates in buildings not specifically designed for low energy use, reaching levels at risk for sensitization. We hypothesize that controlled mechanical ventilation present in all audited LEB may favour lower air humidity and hence lower mite growth and allergen concentration, while preserving optimal perceived comfort.
Resumo:
The purpose of this master’s thesis was to develop a method to be used in the selection of an optimal energy system for buildings and districts. The term optimal energy system was defined as the energy system which best fulfils the requirements of the stakeholder on whose preferences the energy systems are evaluated. The most influential stakeholder in the process of selecting an energy system was considered to be the district developer. The selection method consisted of several steps: Definition of the district, calculating the energy consumption of the district and buildings within the district, defining suitable energy system alternatives for the district, definition of the comparing criteria, calculating the parameters of the comparing criteria for each energy system alternative and finally using a multi-criteria decision method to rank the alternatives. For the purposes of the selection method, the factors affecting the energy consumption of buildings and districts and technologies enabling the use of renewable energy were reviewed. The key element of the selection method was a multi-criteria decision making method, PROMETHEE II. In order to compare the energy system alternatives with the developed method, the comparing criteria were defined in the study. The criteria included costs, environmental impacts and technological and technical characteristics of the energy systems. Each criterion was given an importance, based on a questionnaire which was sent for the steering groups of two district development projects. The selection method was applied in two case study analyses. The results indicate that the selection method provides a viable and easy way to provide the decision makers alternatives and recommendations regarding the selection of an energy system. Since the comparison is carried out by changing the alternatives into numeric form, the presented selection method was found to exclude any unjustified preferences over certain energy systems alternatives which would affect the selection.
Resumo:
This thesis introduces heat demand forecasting models which are generated by using data mining algorithms. The forecast spans one full day and this forecast can be used in regulating heat consumption of buildings. For training the data mining models, two years of heat consumption data from a case building and weather measurement data from Finnish Meteorological Institute are used. The thesis utilizes Microsoft SQL Server Analysis Services data mining tools in generating the data mining models and CRISP-DM process framework to implement the research. Results show that the built models can predict heat demand at best with mean average percentage errors of 3.8% for 24-h profile and 5.9% for full day. A deployment model for integrating the generated data mining models into an existing building energy management system is also discussed.
Resumo:
Eurocode 8 representing a new generation of structural design codes in Europe defines requirements for the design of buildings against earthquake action. In Central and Western Europe, the newly defined earthquake zones and corresponding design ground acceleration values, will lead in many cases to earthquake actions which are remarkably higher than those defined so far by the design codes used until now in Central Europe. In many cases, the weak points of masonry structures during an earthquake are the corner regions of the walls. Loading of masonry walls by earthquake action leads in most cases to high shear forces. The corresponding bending moment in such a wall typically causes a significant increase of the eccentricity of the normal force in the critical wall cross section. This in turn leads ultimately to a reduction of the size of the compression zone in unreinforced walls and a high concentration of normal stresses and shear stresses in the corner regions. Corner-Gap-Elements, consisting of a bearing beam located underneath the wall and made of a sufficiently strong material (such as reinforced concrete), reduce the effect of the eccentricity of the normal force and thus restricts the pinching effect of the compression zone. In fact, the deformation can be concentrated in the joint below the bearing beam. According to the principles of the Capacity Design philosophy, the masonry itself is protected from high stresses as a potential cause of brittle failure. Shaking table tests at the NTU Athens Earthquake Engineering Laboratory have proven the effectiveness of the Corner-Gap-Element. The following presentation will cover the evaluation of various experimental results as well as a numerical modeling of the observed phenomena.
Resumo:
Esta dissertação é muito mais do que um trabalho sobre ajardinamento de edifícios, pois pretende-se que seja uma ferramenta de ajuda em benefício da transformação de milhares de metros quadrados, das coberturas e das fachadas, muitas vezes negligenciados, em espaços verdes públicos beneficiando, não somente, os promotores imobiliários mas, acima de tudo os seus ocupantes e usufrutuários, que desta forma podem tirar partido de novos espaços de estar, ao ar livre. Enquanto a cidade, ao nível térreo, apresenta um aumento de tráfego rodoviário, com inegável poluição e confusão, é possível, desta forma, usufruir de um espaço aberto. Esta dissertação procura estudar os edifícios que já integram o elemento vegetal no seu conceito e que sejam um sucesso na forma como usam o elemento vegetal, de modo a divulgar as técnicas de construção, entender as decisões dos projectistas e o impacto nos utilizadores que habitam e usufruem dos espaços – Análise-Pós-Ocupação. Esta dissertação pretende demonstrar o quanto é importante que as cidades apresentem espaços verdes para uso da população. As zonas verdes existentes nas cidades são inequivocamente um importante indicador da qualidade ambiental existente nessas mesmas cidades. As coberturas e fachadas verdes arrefecem os edifícios, capturam e filtram as águas da chuva, proporcionam habitat à vida selvagem, reduzem o efeito de estufa das cidades, proporcionam uma preciosidade estética, uma experiência recreativa e por vezes comida, para os habitantes das cidades. Pretende-se assim, focar os benefícios humanos, sociais e naturais que se obtêm ao introduzir vegetação nas paredes, terraços, pátios e coberturas dos edifícios. Assim foi considerado útil usar uma metodologia para também analisar o tipo de espécies usadas nos estudos de caso, e determinar a necessidade de uma ferramenta para que a selecção vegetal respeite critérios de biodiversidade e melhor adaptabilidade aos ecossistemas locais, sabendo de antemão que não podem nem pretendem substituir os habitats naturais, que as cidades também podem e devem apresentar.
Resumo:
Flow and turbulence above urban terrain is more complex than above rural terrain, due to the different momentum and heat transfer characteristics that are affected by the presence of buildings (e.g. pressure variations around buildings). The applicability of similarity theory (as developed over rural terrain) is tested using observations of flow from a sonic anemometer located at 190.3 m height in London, U.K. using about 6500 h of data. Turbulence statistics—dimensionless wind speed and temperature, standard deviations and correlation coefficients for momentum and heat transfer—were analysed in three ways. First, turbulence statistics were plotted as a function only of a local stability parameter z/Λ (where Λ is the local Obukhov length and z is the height above ground); the σ_i/u_* values (i = u, v, w) for neutral conditions are 2.3, 1.85 and 1.35 respectively, similar to canonical values. Second, analysis of urban mixed-layer formulations during daytime convective conditions over London was undertaken, showing that atmospheric turbulence at high altitude over large cities might not behave dissimilarly from that over rural terrain. Third, correlation coefficients for heat and momentum were analyzed with respect to local stability. The results give confidence in using the framework of local similarity for turbulence measured over London, and perhaps other cities. However, the following caveats for our data are worth noting: (i) the terrain is reasonably flat, (ii) building heights vary little over a large area, and (iii) the sensor height is above the mean roughness sublayer depth.
Resumo:
An article challenging the frequent assumption that Roman public libraries consisted of architecturally separated spaces divided by language (Latin and Greek). While the evidence for such a division is reasonably strong in some cases, in others it is convention rather than evidence that prompts the labelling of buildings as 'Latin' and 'Greek' libraries. The article is based on a paper given at a major international conference in Paris
Resumo:
Purpose – To evaluate the control strategy for a hybrid natural ventilation wind catchers and air-conditioning system and to assess the contribution of wind catchers to indoor air environments and energy savings if any. Design/methodology/approach – Most of the modeling techniques for assessing wind catchers performance are theoretical. Post-occupancy evaluation studies of buildings will provide an insight into the operation of these building components and help to inform facilities managers. A case study for POE was presented in this paper. Findings – The monitoring of the summer and winter month operations showed that the indoor air quality parameters were kept within the design target range. The design control strategy failed to record data regarding the operation, opening time and position of wind catchers system. Though the implemented control strategy was working effectively in monitoring the operation of mechanical ventilation systems, i.e. AHU, did not integrate the wind catchers with the mechanical ventilation system. Research limitations/implications – Owing to short-falls in the control strategy implemented in this project, it was found difficult to quantify and verify the contribution of the wind catchers to the internal conditions and, hence, energy savings. Practical implications – Controlling the operation of the wind catchers via the AHU will lead to isolation of the wind catchers in the event of malfunctioning of the AHU. Wind catchers will contribute to the ventilation of space, particularly in the summer months. Originality/value – This paper demonstrates the value of POE as indispensable tool for FM professionals. It further provides insight into the application of natural ventilation systems in building for healthier indoor environments at lower energy cost. The design of the control strategy for natural ventilation and air-conditioning should be considered at the design stage involving the FM personnel.
Resumo:
We examined how far, and at what cost, the housing stock could be modified to accommodate the assistive technology (AT) necessary to enable older people to remain in their own homes. A multidisciplinary team devised seven hypothetical user profiles for 10 case study areas, with five local authorities and five housing associations in England and Wales. Each profile was considered at two times, five years apart, with the users' functional abilities deteriorating in between. In addition, in-depth interviews were carried out with a sample of 67 older people in the case study areas about their use and experience of a wide range of AT. The interviews showed the need to listen to older people and that they welcomed AT when it addressed a perceived need. The results showed that the extent of adaptation required of buildings to accommodate a user's needs varied greatly. It was also found that there was confusion about the terminology of AT, including the idea of the 'smart house'. The study shows that the adaptability of the housing depends on a range of factors and costs.