990 resultados para FRP-concrete bond
Resumo:
An experimental research addressing the effects of concrete composition and strength on anchorage bond behavior of prestressing reinforcement is presented to clarify the effect of material properties that have appeared contradictory in previous literature. Bond stresses and anchorage lengths have been obtained in twelve concrete mixes made up of different cement contents (C) – 350 to 500 kg/m3 – and water/cement (w/c) ratios – 0.3 to 0.5 – with compressive strength at 24 h ranging from 24 to 55 MPa. A testing technique based on measuring the prestressing force in specimens with different embedment lengths has been used. The results show that anchorage length increases when w/c increases, more significantly when C is higher; the effect of C reveals different trends based on w/c. The obtained anchorage bond stresses are greater for higher concrete compressive strength, and their average ratio of 1.45 with respect to transmission bond stresses implies a potential bond capacity.
Resumo:
In this study, 21 small beam specimens with a pre-set through-crack were tested with FRP strips bonded to the sides to study the bond behavior between shear-strengthening FRP and concrete (referred to as "the interface" for simplicity hereafter). The test parameters included the bond length, width, thickness of FRP strip and the angle between fiber orientation and crack opening direction (referred to as "fiber tensile angle" θ hereafter) on the bond behavior of the interface. Test results showed that: 1) the small beam test setup with a pre-set crack is suitable for studying the bond behavior between FRP and concrete; 2) the bond length, width, and thickness of the FRP as well as the fiber angle have significant effects on the bond strength; 3) the distribution of FRP strains along the direction perpendicular to the fiber orientation (FRP width direction) is non-uniform; this is mainly attributed to the progressive debonding of the FRP strips in the width direction, with the FRP at the location of larger crack width debonding earlier.
Resumo:
Existing studies have shown conclusively that the measured fibre reinforced polymer (FRP) rupture strain in FRP wrapped concrete columns is usually significantly smaller than the rupture strain obtained from flat coupon tests. One of the main causes for this phenomenon is the existence of geometrical discontinuities at both ends of the FRP sheets. This study proposes a new strengthening method in which continuous FRP spiral wrapping is used to eliminate strain concentrations due to the geometrical discontinuities and thus increase the FRP rupture strain at column failure. The effect of the spiral angle of FRP on the FRP rupture strain in FRP wrapped specimens was experimentally investigated. The test results indicate that the spiral wrapping with a small angle with respect to the column circumference can significantly increase the strain efficiency of FRP and thus enhance the axial compression capacity of the strengthened cylinders.
Resumo:
Concrete cover separation is a common failure mode of reinforced concrete (RC) beams strengthened with a fibre-reinforced polymer (FRP) plate bonded to the tension face (FRP-plated RC beams). Plate-end FRP U-jackets have previously been explored as a mitigation measure to delay or suppress concrete cover separation, although its effectiveness needs further clarification. The paper presents the first systemic experimental study on the use of FRP U-jackets of different forms for mitigating the concrete cover separation failure. A total of ten full-scale FRP-plated RC beams were tested. The test results show that both the ultimate load and the ductility of the beams were enhanced by the U-jackets. Among the forms of U-jackets explored, those inclined at 45o are the most effective.