971 resultados para FORCED SWIMMING TEST
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Previous studies show that chronic hemiparetic patients after stroke, presents inabilities to perform movements in paretic hemibody. This inability is induced by positive reinforcement of unsuccessful attempts, a concept called learned non-use. Forced use therapy (FUT) and constraint induced movement therapy (CIMT) were developed with the goal of reversing the learned non-use. These approaches have been proposed for the rehabilitation of the paretic upper limb (PUL). It is unknown what would be the possible effects of these approaches in the rehabilitation of gait and balance. Objectives: To evaluate the effect of Modified FUT (mFUT) and Modified CIMT (mCIMT) on the gait and balance during four weeks of treatment and 3 months follow-up. Methods: This study included thirty-seven hemiparetic post-stroke subjects that were randomly allocated into two groups based on the treatment protocol. The non-paretic UL was immobilized for a period of 23 hours per day, five days a week. Participants were evaluated at Baseline, 1st, 2nd, 3rd and 4th weeks, and three months after randomization. For the evaluation we used: The Stroke Impact Scale (SIS), Berg Balance Scale (BBS) and Fugl-Meyer Motor Assessment (FM). Gait was analyzed by the 10-meter walk test (T10) and Timed Up & Go test (TUG). Results: Both groups revealed a better health status (SIS), better balance, better use of lower limb (BBS and FM) and greater speed in gait (T10 and TUG), during the weeks of treatment and months of follow-up, compared to the baseline. Conclusion: The results show mFUT and mCIMT are effective in the rehabilitation of balance and gait. Trial Registration ACTRN12611000411943.
Resumo:
Background: The six-minute-walk-test (6MWT) has been increasingly used in cystic fibrosis (CF) patients. However, few studies in children have correlated 6MWT with current parameters used to evaluate CF severity. Moreover, no study transformed the values of distance walked from meters into Z scores to avoid bias like age and gender, which are sources of 6MWT variability. Methods: A cross-sectional descriptive study was performed to analyze the correlations (Spearman) among forced expiratory volume in one second (FEV1), body mass index (BMI), chest radiography (CXR), chest tomography (CT), and 6MWT Z score (Z-6MWT). Clinically stable CF patients, aged 6-21 years, were included. Results: 34 patients, 14F/20M, mean age 12.1 +/- 4.0 years were studied. The mean Z-6MWT was -1.1 +/- 1.106. The following correlations versus Z-6MWT were found: FEV1 (r=0.59, r(2)=0.32, p=0.0002), BMI Z score (r=0.42, r(2)=0.17, p=0.013), CXR (r=0.34, r(2)=0.15, p=0.0472) and CT (r=-0.45, r(2)=0.23, p=0.0073). Conclusions: In conclusion there was a significant, but poor, correlation between the six minute walk test Z score and the cystic fibrosis severity markers currently in use. (C) 2011 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Resumo:
The last decade has witnessed very fast development in microfabrication technologies. The increasing industrial applications of microfluidic systems call for more intensive and systematic knowledge on this newly emerging field. Especially for gaseous flow and heat transfer at microscale, the applicability of conventional theories developed at macro scale is not yet completely validated; this is mainly due to scarce experimental data available in literature for gas flows. The objective of this thesis is to investigate these unclear elements by analyzing forced convection for gaseous flows through microtubes and micro heat exchangers. Experimental tests have been performed with microtubes having various inner diameters, namely 750 m, 510 m and 170 m, over a wide range of Reynolds number covering the laminar region, the transitional zone and also the onset region of the turbulent regime. The results show that conventional theory is able to predict the flow friction factor when flow compressibility does not appear and the effect of fluid temperature-dependent properties is insignificant. A double-layered microchannel heat exchanger has been designed in order to study experimentally the efficiency of a gas-to-gas micro heat exchanger. This microdevice contains 133 parallel microchannels machined into polished PEEK plates for both the hot side and the cold side. The microchannels are 200 µm high, 200 µm wide and 39.8 mm long. The design of the micro device has been made in order to be able to test different materials as partition foil with flexible thickness. Experimental tests have been carried out for five different partition foils, with various mass flow rates and flow configurations. The experimental results indicate that the thermal performance of the countercurrent and cross flow micro heat exchanger can be strongly influenced by axial conduction in the partition foil separating the hot gas flow and cold gas flow.
Resumo:
The aim was to test the feasibility of protocol-driven fluid removal with continuous renal replacement therapy (CRRT) in patients in whom standard fluid balance prescription did not result in substantial negative fluid balances.
Resumo:
Background Whole-body water immersion leads to a significant shift of blood from the periphery into the intra-thoracic circulation, followed by an increase in central venous pressure and heart volume. In patients with severely reduced left ventricular function, this hydrostatically in-duced volume shift might overstrain the cardiovascular adaptive mechanisms and lead to cardiac decompensation. The aim of this study is to assess the hemodynamic response to water immer-sion, gymnastics and swimming in patients with heart failure (CHF). Methods We examined 10 patients with compensated CHF (62.9 +/- 6.3 years, EF 31.5 +/- 4.1%, peak VO2 19.4 +/- 2.8 ml/kg/min.), 10 patients with coronary artery disease (CAD) but preserved left ventricular function (57.2 +/- 5.6 years, EF 63.9 +/- 5.5%, peak VO2 28.0 +/- 6.3 ml/kg/min.) and 10 healthy subjects (32.8 +/- 7.2 years, peak VO2 45.6 +/- 6.0 ml/kg/min.). Hemodynamic response to thermo-neutral (32 degrees C) water immersion and exercise was measured using a non-invasive foreign gas rebreathing method during stepwise water immersion, water gymnastics and swimming. Results Water immersion up to the chest increased cardiac index by 19% in healthy subjects, by 21% in CAD patients and 16% in CHF patients. While some CHF patients showed a decrease of stroke volume during immersion, all subjects were able to increase cardiac index (by 87% in healthy subjects, 77% in CAD patients and 53% in CHF patients). Oxygen uptake during swim-ming was 9.7 +/- 3.3 ml/kg/min. in CHF patients, 12.4 +/- 3.5 ml/kg/min. in CAD patients and 13.9 +/- 4.0 ml/kg/min. in healthy subjects. Conclusions Patients with severely reduced left ventricular function but stable clinical conditions and a minimal peak VO2 of at least 15 ml/kg/min. during a symptom-limited exercise stress test tolerate water immersion and swimming in thermo-neutral water well. Although cardiac in-dex and oxygen uptake are lower compared with CAD patients with preserved left ventricular function and healthy controls, these patients are able to increase cardiac index adequately during water immersion and swimming.
Resumo:
Traditionally, critical swimming speed has been defined as the speed when a fish can no longer propel itself forward, and is exhausted. To gain a better understanding of the metabolic processes at work during a U(crit) swim test, and that lead to fatigue, we developed a method using in vivo (31)P-NMR spectroscopy in combination with a Brett-type swim tunnel. Our data showed that a metabolic transition point is reached when the fish change from using steady state aerobic metabolism to non-steady state anaerobic metabolism, as indicated by a significant increase in inorganic phosphate levels from 0.3+/-0.3 to 9.5+/-3.4 mol g(-1), and a drop in intracellular pH from 7.48+/-0.03 to 6.81+/-0.05 in muscle. This coincides with the point when the fish change gait from subcarangiform swimming to kick-and-glide bursts. As the number of kicks increased, so too did the Pi concentration, and the pH(i) dropped. Both changes were maximal at U(crit). A significant drop in Gibbs free energy change of ATP hydrolysis from -55.6+/-1.4 to -49.8+/-0.7 kJ mol(-1) is argued to have been involved in fatigue. This confirms earlier findings that the traditional definition of U(crit), unlike other critical points that are typically marked by a transition from aerobic to anaerobic metabolism, is the point of complete exhaustion of both aerobic and anaerobic resources.
Resumo:
Recently, swimming-style colour synaesthesia was introduced as a new form of synaesthesia. A synaesthetic Stroop test was used to establish its genuineness. Since Stroop interference can occur for any type of overlearned association, in the present study we used a modified Stroop test and psychophysiological synaesthetic conditioning to further establish the genuineness of this form of synaesthesia. We compared the performance of a swimming-style colour synaesthete and a control who was trained on swimming-style colour associations. Our results showed that behavioural aspects of swimming-style colour synaesthesia can be mimicked in a trained control. Importantly, however, our results showed a psychophysiological conditioning effect for the synaesthete only. We discuss the theoretical relevance of swimming-style colour synaesthesia according to different models of synaesthesia. We conclude that swimming-style colour synaesthesia is a genuine form of synaesthesia, can be mimicked behaviourally in non-synaesthetes, and is best explained by a re-entrant feedback model.
Resumo:
The aim of this thesis is the subjective and objective evaluation of angledependent absorption coefficients. As the assumption of a constant absorption coefficient over the angle of incidence is not always held, a new model acknowledging an angle-dependent reflection must be considered, to get a more accurate prediction in the sound field. The study provides information about the behavior of different materials in several rooms, depending on the reflection modeling of incident sound waves. An objective evaluation was run for an implementation of angle-dependent reflection factors in the image source and ray tracing simulation models. Results obtained were analysed after comparison to diffuse-field averaged data. However, changes in acoustic characteristics of a room do not always mean a variation in the listener’s perception. Thus, additional subjective evaluation allowed a comparison between the different results obtained with the computer simulation and the response from the individuals who participated in the listening test. The listening test was designed following a three-alternative forced-choice (3AFC) paradigm. In each interaction asked to the subjects a sequence of either three pink noise bursts or three natural signals was alternated. These results were supposed to show the influence and perception of the two different ways to implement surface reflection –either with diffuse or angle-dependent absorption properties. Results show slightly audible effects when material properties were exaggerated. El objetivo de este trabajo es la evaluación objetiva y subjetiva del coeficiente de absorción en función del ángulo de incidencia de la onda de sonido. La suposición de un coeficiente de absorción constante con respecto al ángulo de incidencia no siempre se sostiene. Por ello, un nuevo modelo considerando la reflexión dependiente del ángulo se debe tener en cuenta para obtener predicciones más certeras en el campo del sonido. El estudio proporciona información sobre el comportamiento de diferentes materiales en distintos recintos, dependientes del modelo de reflexión de las ondas de sonido incidentes. Debido a las dificultades a la hora de realizar las medidas y, por lo tanto, a la falta de datos, los coeficientes de absorción dependientes del ángulo a menudo no se tienen en cuenta a la hora de realizar las simulaciones. Hoy en día, aún no hay una tendencia de aplicar el coeficiente de absorción dependiente del ángulo para mejorar los modelos de reflexión. Por otra parte, para una medición satisfactoria de la absorción dependiente del ángulo, sólo hay unos pocos métodos. Las técnicas de medición actuales llevan mucho tiempo y hay algunos materiales, condiciones y ángulos que no pueden ser reproducidos y, por lo tanto, no es posible su medición. Sin embargo, en el presente estudio, los ángulos de incidencia de las ondas de sonido son conocidos y almacenados en una de base de datos para cada uno de los materiales, de modo que los coeficientes de absorción para el ángulo dado pueden ser devueltos siempre que sean requeridos por el usuario. Para realizar el estudio se llevó a cabo una evaluación objetiva, por medio de la implementación del factor de reflexión dependiente del ángulo en los modelos de fuentes imagen y trazado de rayos. Los resultados fueron analizados después de ser comparados con el promedio de los datos obtenidos en medidas en el campo difuso. La simulación se hizo una vez se configuraron un número de materiales creados por el autor, a partir de los datos existentes en la literatura y los catálogos de fabricantes. Los modelos de Komatsu y Mechel sirvieron como referencia para los materiales porosos, configurando la resistividad al aire o el grosor, y para los paneles perforados, introduciendo el radio de los orificios y la distancia entre centros, respectivamente. Estos materiales se situaban en la pared opuesta a la que se consideraba que debía alojar a la fuente sonora. El resto de superficies se modelaban con el mismo material, variando su coeficiente de absorción y/o de dispersión. Al mismo tiempo, una serie de recintos fueron modelados para poder reproducir distintos escenarios de los que obtener los resultados. Sin embargo, los cambios en las características acústicas de un recinto no significan variaciones en la percepción por parte del oyente. Por ello, una evaluación subjetiva adicional permitió una comparación entre los diferentes resultados obtenidos mediante la simulación informática y la respuesta de los individuos que participaron en la prueba de escucha. Ésta fue diseñada bajo las pautas del modelo de test three-alternative forced-choice (3AFC), con treinta y dos preguntas diferentes. En cada iteración los sujetos fueron preguntados por una secuencia alterna entre tres señales, siendo dos de ellas iguales. Éstas podían ser tanto ráfagas de ruido rosa como señales naturales, en este test se utilizó un fragmento de una obra clásica interpretada por un piano. Antes de contestar al cuestionario, los bloques de preguntas eran ordenados al azar. Para cada ensayo, la mezcla era diferente, así los sujetos no repetían la misma prueba, evitando un sesgo por efectos de aprendizaje. Los bloques se barajaban recordando siempre el orden inicial, para después almacenar los resultados reordenados. La prueba de escucha fue realizada por veintitrés personas, toda ellas con conocimientos dentro del campo de la acústica. Antes de llevar a cabo la prueba de escucha en un entorno adecuado, una hoja con las instrucciones fue facilitada a cada persona. Los resultados muestran la influencia y percepción de las dos maneras distintas de implementar las reflexiones de una superficie –ya sea con respecto a la propiedad de difusión o de absorción dependiente del ángulo de los materiales. Los resultados objetivos, después de ejecutar las simulaciones, muestran los datos medios obtenidos para comprender el comportamiento de distintos materiales de acuerdo con el modelo de reflexión utilizado en el caso de estudio. En las tablas proporcionadas en la memoria se muestran los valores del tiempo de reverberación, la claridad y el tiempo de caída temprana. Los datos de las características del recinto obtenidos en este análisis tienen una fuerte dependencia respecto al coeficiente de absorción de los diferentes materiales que recubren las superficies del cuarto. En los resultados subjetivos, la media de percepción, a la hora de distinguir las distintas señales, por parte de los sujetos, se situó significativamente por debajo del umbral marcado por el punto de inflexión de la función psicométrica. Sin embargo, es posible concluir que la mayoría de los individuos tienden a ser capaces de detectar alguna diferencia entre los estímulos presentados en el 3AFC test. En conclusión, la hipótesis de que los valores del coeficiente de absorción dependiente del ángulo difieren es contrastada. Pero la respuesta subjetiva de los individuos muestra que únicamente hay ligeras variaciones en la percepción si el coeficiente varía en intervalos pequeños entre los valores manejados en la simulación. Además, si los parámetros de los materiales acústicos no son exagerados, los sujetos no perciben ninguna variación. Los primeros resultados obtenidos, proporcionando información respecto a la dependencia del ángulo, llevan a una nueva consideración en el campo de la acústica, y en la realización de nuevos proyectos en el futuro. Para futuras líneas de investigación, las simulaciones se deberían realizar con distintos tipos de recintos, buscando escenarios con geometrías irregulares. También, la implementación de distintos materiales para obtener resultados más certeros. Otra de las fases de los futuros proyectos puede realizarse teniendo en cuenta el coeficiente de dispersión dependiente del ángulo de incidencia de la onda de sonido. En la parte de la evaluación subjetiva, realizar una serie de pruebas de escucha con distintos individuos, incluyendo personas sin una formación relacionada con la ingeniería acústica.
Resumo:
Mode of access: Internet.
Resumo:
Although the functional consequences of temperature variation have been examined for a wide range of whole-animal performance traits, the implications of thermal variation for reproductive behaviour or performance are poorly known. I examined the acute effects of temperature on the mating behaviour and swimming performance of male eastern mosquitofish, Gambusia holbrooki, which rely on a coercive strategy to obtain matings and are routinely exposed to wide daily temperature fluctuations. Males showed reproductive behaviours across the entire test temperature range of 14-38 degrees C, representing one of the widest reproductively active temperature ranges for any ectotherm. Both the time spent in pursuit of females and the total number of mating attempts increased with temperature to a plateau that started at approximately 22-26 degrees C. However, males maintained a constant level of copulations at 18-34 degrees C, the temperature range they routinely experience in southeast Queensland. In contrast, maximum swimming performance and approach speeds during copulations were highly thermally dependent across this temperature range. Thus, acute temperature variation has important fitness implications for male G. holbrooki, but mating performance was significantly limited only at extreme temperatures. (c) 2005 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.
Resumo:
All copulations in the eastern mosquitofish, Gambusia holbrooki, are coercive-and-achieved by force. Female G. holbrooki never appear to cooperate with males, but vigorously resist matings at all times. We examined the role of females within a sexually coercive mating system by investigating the ability of female G. holbrooki to resist forced copulations after acclimation to 16 degrees C and 32 degrees C for 4-5 weeks. We also examined burst swimming performance of female G. holbrooki after acclimation, as this trait is likely to underlie a female's ability to resist forced matings. We predicted that if female G. holbrooki indiscriminately resist matings from all males, acclimation would enhance female resistance at their acclimation temperature. However, we found that it did not. We also predicted that if females are able to influence the outcome of mating interactions, acclimation to an optimal thermal environment may induce females to reduce resistance. In support of this prediction, females acclimated at 32 degrees C were able to modify their resistance behaviour between exposure to 16 degrees C and 32 degrees C. The rate of copulations experienced by 32 inverted perpendicular C-acclimated females was 2.5 times greater at 32 degrees C than at 16 degrees C. In addition, acclimation at 32 degrees C significantly enhanced burst swimming performance at 32 degrees C but no effect of acclimation was observed at 16 degrees C. Our results suggest that female G. holbrooki are able to play a greater role in determining the outcome of sexual coercive mating interactions than previously thought. (c) 2006 The Association for the Shidy of Animal Behavioor. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background: The Melbourne Edge Test (MET) is a portable forced-choice edge detection contrast sensitivity (CS) test. The original externally illuminated paper test has been superseded by a backlit version. The aim of this study was to establish normative values for age and to assess change with visual impairment. Method: The MET was administered to 168 people with normal vision (18-93 years old) and 93 patients with visual impairment (39-97 years old). Distance visual acuity (VA) was measured with a log MAR chart. Results: In those eyes without disease, MET CS was stable until the age of 50 years (23.8 ± .7 dB) after which it decreased at a rate of ≈1.5 dB per decade. Compared with normative values, people with low vision were found to have significantly reduced CS, which could not be totally accounted for by reduced VA. Conclusions: The MET provides a quick and easy measure of CS, which highlights a reduction in visual function that may not be detectable using VA measurements. © 2004 The College of Optometrists.