424 resultados para FIBRILLATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is associated with an increased risk of thromboembolism, and is the most prevalent factor for cardioembolic stroke. Vitamin K antagonists (VKAs) have been the standard of care for stroke prevention in patients with AF since the early 1990s. They are very effective for the prevention of cardioembolic stroke, but are limited by factors such as drug-drug interactions, food interactions, slow onset and offset of action, haemorrhage and need for routine anticoagulation monitoring to maintain a therapeutic international normalised ratio (INR). Multiple new oral anticoagulants have been developed as potential replacements for VKAs for stroke prevention in AF. Most are small synthetic molecules that target thrombin (e.g. dabigatran etexilate) or factor Xa (e.g. rivaroxaban, apixaban, edoxaban, betrixaban, YM150). These drugs have predictable pharmacokinetics that allow fixed dosing without routine laboratory monitoring. Dabigatran etexilate, the first of these new oral anticoagulants to be approved by the United States Food and Drug Administration and the European Medicines Agency for stroke prevention in patients with non-valvular AF, represents an effective and safe alternative to VKAs. Under the auspices of the Regional Anticoagulation Working Group, a multidisciplinary group of experts in thrombosis and haemostasis from Central and Eastern Europe, an expert panel with expertise in AF convened to discuss practical, clinically important issues related to the long-term use of dabigatran for stroke prevention in non-valvular AF. The practical information reviewed in this article will help clinicians make appropriate use of this new therapeutic option in daily clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Atrial fibrillation (AF) is common and may have severe consequences. Continuous long-term electrocardiogram (ECG) is widely used for AF screening. Recently, commercial ECG analysis software was launched, which automatically detects AF in long-term ECGs. It has been claimed that such tools offer reliable AF screening and save time for ECG analysis. However, this has not been investigated in a real-life patient cohort. Objective To investigate the performance of automatic software-based screening for AF in long-term ECGs. Methods Two independent physicians manually screened 22,601 hours of continuous long-term ECGs from 150 patients for AF. Presence, number, and duration of AF episodes were registered. Subsequently, the recordings were screened for AF by an established ECG analysis software (Pathfinder SL), and its performance was validated against the thorough manual analysis (gold standard). Results Sensitivity and specificity for AF detection was 98.5% (95% confidence interval 91.72%–99.96%) and 80.21% (95% confidence interval 70.83%–87.64%), respectively. Software-based AF detection was inferior to manual analysis by physicians (P < .0001). Median AF duration was underestimated (19.4 hours vs 22.1 hours; P < .001) and median number of AF episodes was overestimated (32 episodes vs 2 episodes; P < .001) by the software. In comparison to extensive quantitative manual ECG analysis, software-based analysis saved time (2 minutes vs 19 minutes; P < .001). Conclusion Owing to its high sensitivity and ability to save time, software-based ECG analysis may be used as a screening tool for AF. An additional manual confirmatory analysis may be required to reduce the number of false-positive findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES This study sought to identify nonredundant atrial fibrillation (AF) genetic susceptibility signals and examine their cumulative relations with AF risk. BACKGROUND AF-associated loci span broad genomic regions that may contain multiple susceptibility signals. Whether multiple signals exist at AF loci has not been systematically explored. METHODS We performed association testing conditioned on the most significant, independently associated genetic markers at 9 established AF loci using 2 complementary techniques in 64,683 individuals of European ancestry (3,869 incident and 3,302 prevalent AF cases). Genetic risk scores were created and tested for association with AF in Europeans and an independent sample of 11,309 individuals of Japanese ancestry (7,916 prevalent AF cases). RESULTS We observed at least 4 distinct AF susceptibility signals on chromosome 4q25 upstream of PITX2, but not at the remaining 8 AF loci. A multilocus score comprised 12 genetic markers demonstrated an estimated 5-fold gradient in AF risk. We observed a similar spectrum of risk associated with these markers in Japanese. Regions containing AF signals on chromosome 4q25 displayed a greater degree of evolutionary conservation than the remainder of the locus, suggesting that they may tag regulatory elements. CONCLUSIONS The chromosome 4q25 AF locus is architecturally complex and harbors at least 4 AF susceptibility signals in individuals of European ancestry. Similar polygenic AF susceptibility exists between Europeans and Japanese. Future work is necessary to identify causal variants, determine mechanisms by which associated loci predispose to AF, and explore whether AF susceptibility signals classify individuals at risk for AF and related morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM To assess the prevalence of vascular dementia, mixed dementia and Alzheimer's disease in patients with atrial fibrillation, and to evaluate the accuracy of the Hachinski ischemic score for these subtypes of dementia. METHODS A nested case-control study was carried out. A total of 103 of 784 consecutive patients evaluated for cognitive status at the Ambulatory Geriatric Clinic had a diagnosis of atrial fibrillation. Controls without atrial fibrillation were randomly selected from the remaining 681 patients using a 1:2 matching for sex, age and education. RESULTS The prevalence of vascular dementia was twofold in patients with atrial fibrillation compared with controls (21.4% vs 10.7%, P = 0.024). Alzheimer's disease was also more frequent in the group with atrial fibrillation (12.6% vs 7.3%, P = 0.046), whereas mixed dementia had a similar distribution. The Hachinski ischemic score poorly discriminated between dementia subtypes, with misclassification rates between 46% (95% CI 28-66) and 70% (95% CI 55-83). In patients with atrial fibrillation, these rates ranged from 55% (95% CI 32-77) to 69% (95% CI 39-91%). In patients in whom the diagnosis of dementia was excluded, the Hachinski ischemic score suggested the presence of vascular dementia in 11% and mixed dementia in 30%. CONCLUSIONS Vascular dementia and Alzheimer's disease, but not mixed dementia, are more prevalent in patients with atrial fibrillation. The discriminative accuracy of the Hachinski ischemic score for dementia subtypes in atrial fibrillation is poor, with a significant proportion of misclassifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes. Objective We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation. Methods A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients were randomized to either cardioversion (PVI-alone group; n = 33) or additional CFAE ablation (PVI+CFAE group; n = 35) and followed up every 1–3 months and serial Holter recordings were also obtained. The primary end point was the recurrence of AF/atrial tachycardia (AT) after a blanking period of 3 months. Results Procedure duration (127 ± 6 minutes vs 174 ± 10 minutes), radiofrequency application time (44 ± 3 minutes vs 74 ± 5 minutes), and fluoroscopy time (26 ± 2 minutes vs 41 ± 3 minutes) were longer in the PVI+CFAE group (all P < .001). In 30 of 35 patients (86%) in the PVI+CFAE group, ablation terminated AF. There was no significant group difference with respect to freedom from AF/AT (22 of 33 [67%] vs 22 of 35 [63%]; P = .66). Subsequently, 10 of 11 patients in the PVI-alone group (91%) and 11 of 13 patients in PVI+CFAE group (85%) underwent repeat ablation (P = 1.00). Overall, 29 of 33 [88%] vs 30 of 35 [86%] patients (P = 1.00) were free from AF/AT after 1.4 ± 0.1 vs 1.4 ± 0.2 (P = .87) procedures. Conclusion Patients with sustained AF after PVI in a PAF cohort are rare. Regarding AF/AT recurrence, these patients did not benefit from further CFAE ablation compared to PVI alone, but are exposed to longer procedure duration, fluoroscopy time, and radiofrequency application time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Rapid pulmonary vein (PV) activity has been shown to maintain paroxysmal atrial fibrillation (AF). We evaluated in persistent AF the cycle length (CL) gradient between PVs and the left atrium (LA) in an attempt to identify the subset of patients where PVs play an important role. METHODS AND RESULTS Ninety-seven consecutive patients undergoing first ablation for persistent AF were studied. For each PV, the CL of the fastest activation was assessed over 1 minute (PVfast) using Lasso recordings. The PV to LA CL gradient was quantified by the ratio of PVfast to LA appendage (LAA) AF CL. Stepwise ablation terminated AF in 73 patients (75%). In the AF termination group, the PVfast CL was much shorter than the LAA CL resulting in lower PVfast/LAA ratios compared with the nontermination group (71±10% versus 92±7%; P<0.001). Within the termination group, PVfast/LAA ratios were notably lower if AF terminated after PV isolation or limited adjunctive substrate ablation compared with patients who required moderate or extensive ablation (63±6% versus 75±8%; P<0.001). PVfast/LAA ratio <69% predicted AF termination after PV isolation or limited substrate ablation with 74% positive predictive value and 95% negative predictive value. After a mean follow-up of 29±17 months, freedom from arrhythmia recurrence off-antiarrhythmic drugs was achieved in most patients with PVfast/LAA ratios <69% as opposed to the remaining population (80% versus 43%; P<0.001). CONCLUSIONS The PV to LA CL gradient may identify the subset of patients in whom persistent AF is likely to terminate after PV isolation or limited substrate ablation and better long-term outcomes are achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND -This study aimed to determine five-year efficacy of catheter ablation for persistent atrial fibrillation (PsAF) using AF termination as a procedural endpoint. METHODS AND RESULTS -150 patients (57±10 years) underwent PsAF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided and linear ablation) with the desired procedural endpoint being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia (AT). AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3±3.9%, 28.0±3.7%, and 16.8±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7±2.5%, 79.8±3.4%, and 62.9±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (IQR 43-73) months following the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs (AADs). Another 14 (9.3%) patients maintained sinus rhythm after re-initiation of AADs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (HR 3.831; 95%CI: 2.070-7.143; p<0.001), left atrial diameter ≥50mm (HR 2.083; 95%CI: 1.078-4.016; p=0.03), continuous AF duration ≥18 months (HR 1.984; 95%CI: 1.024-3.846; p<0.04) and structural heart disease (HR 1.874; 95% CI: 1.037-3.388; p=0.04) predicted arrhythmia recurrence. CONCLUSIONS -In patients with PsAF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow up period.Procedural AF non-termination and specific baseline factors predict long-term outcome after ablation.