1000 resultados para FÍSICA MÉDICA


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research presents a study of structural complexes formed between the bothropstoxin BthTX-I and PrTX-I and phospholipase A2 (PLA2s) inhibitor 12- methoxy-4-methyl-voachalotine (MMV) of Tabernamontana catharinensis and rosmarinic acid (Cv-RA) of Rosmarinus officinalis. For both were used cocrystallization experiments with the toxins and inhibitors. In the future, the experimental three-dimensional structures of these complexes will be obtained through the technique of crystallography. Simultaneously, construction occurred in silico of inhibitors Cv-RA and MMV and attempts of docking between these binders and protein structures. These theoretical data provide important information regarding the nature of interactions between inhibitors, toxins and structural changes induced by the protein molecule inhibitors. Therefore, the acquisition of this information has great value to identification, characterization and development (drug design) of compounds with great potential for biotechnology and drug use. Considering further and more relevant aplications, these compounds could be used to control symptoms in many cases of ophidic poisoning and also in combating of pathological processes (degenerative inflammatory diseases and auto-immune diseases, Alzheimer's disease, schizophrenia, among others) whose causes are related to molecules belonging to the same groups of proteins which are classified bothropstoxin that were studied in this project

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the increase of stakeholders and consequently increase of amount of nancial transaction the study of news investment strategies in the stock market with data mining techniques has been the target of important researches. It allows that great historical data base to be processed and analysed looking for pattern that can be used to take a decision in investments. With the idea of getting pro t more than the real indexs' gain, we propose a strategy method of transactions using rules built by algorithm classi cation. For that, diary historical data of Ibovespa index and Petrobras stocks are organized and processed to nding the most important attribute that act decisively when taking a investment decision.To test the accuracy of proposed rules, a non real portfolio management is created, showing the decisions' performance over the real index and stocks' performance. Following the proposed rules, the results show that the strategy of investment give me back a high return that Stock market's return. The exclusive characteristics of algorithms maximize the gain inside the analysed time allowing to determine the techniques' return and the number of the days necessary to double the initial investment. The best classi er applied on the time series and its use on the propose investments strategy will demand 104 days to double the initial capital

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a computational analysis, using a cellular automata model, has been developed to analyze post-feeding dispersal behavior of blow y larvae. This model aimed to: simulate the exponential decline of pupal number in relation to the feed source and spatial oscillation due to larval interaction during dispersal; study whether the prior pupal presence in uences distribution patterns of larval frequency; and compare obtained unidirectional dispersal patterns to the cross-dimensional ones. The cellular automata (CA) model was able to successfully reproduce the essential features of the larval dispersal process and, thus, show the importance of local interaction in the studied dispersal process dynamics. Oscillations could be explained by the interaction among dispersing larvae and intrinsic pupation time. The box size and the initial larval density were important factors for the experiment because they in uenced the results. Results showed that the unidirectional dispersal could be used to simulate the larval dispersion that occurs in the natural environment, because both models had a similar result. These results are important to understand how di erent factors can in uence the dynamics of blow y larval dispersal, bringing important results for behavioral ecology and forensic entomology

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work consists of a case study, a qualitative methodology, which aims to show the effects of TIVALLEC, a supplement in vitamins, as an alternative treatment of cancer. This study had also the objective of evaluating one patient’s quality of life thirteen years after being diagnosed with an advanced prostate cancer, and having decided for an alternative treatment using TIVALLEC instead of conventional treatments, having obtained excellent results. An open interview was conducted with patient, evaluating various aspects of his life after the initial diagnosis and the chosen treatment. The answers were transcribed after being limitedly edited for readability. At the end of the study, with the support of recent literature, the interview allowed the conclusion that TIVALLEC was greatly effective, creating good quality of life and wellness for the patient during all the period of thirteen year after the diagnosis up to now. These alternative treatment results may be seen as demanding new studies to help cancer patients who embrace or not the conventional treatments

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chitosan is a natural biodegradable polymer with great potential for pharmaceutical applications due to its biocompatibility, high charge density , nontoxicity and mucoadhesion. Gel formation can be obtained by the interactions of chitosans with low molecular counterions such as polyphosphates, sulphates and crosslinking with glutaraldehyde. This gelling property of chitosan allows a wide range of applications such as coating of pharmaceuticals and food products, gel entrapment of biochemicals, whole cells, microorganisms and algae. One of its main applications is the synthesis of microspheres for coating of pharmaceuticals , magnetic particles an other substances. In such a way, we can build targeted drug delivery systems. In the present work, we applied the method of spraying and coagulation. The resulting microspheres, then, were characterized by optical microscopy

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho consiste em desenvolver um programa que seja capaz de descrever a trajetória da bola durante o saque de vôlei. Para isso, foram analisadas todas as forças que atuam sobre a bola e com isso montar um sistema de equações. Para que este possa descreva a trajetória percorrida e assim fornecer melhoria para o fundamento prático para a equipe de Vôlei Medley/Campinas

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The huge demand for procedures involving ionizing radiation promotes the need for safe methods of experimentation considering the danger of their biological e ects with consequent risk to humans. Brazilian's legislation prohibits experiments involving this type of radiation in humans through Decree 453 of Ministry of Health with determines that such procedures comply with the principles of justi cation, optimization and dose limitation. In this line, concurrently with the advancement of available computer processing power, computing simulations have become relevant in those situations where experimental procedures are too cost or impractical. The Monte Carlo method, created along the Manhattan Project duringWorldWar II, is a powerful strategy to simulations in computational physics. In medical physics, this technique has been extensively used with applications in diagnostics and cancer treatment. The objective of this work is to simulate the production and detection of X-rays for the energy range of diagnostic radiology, for molybdenum target, using the Geant4 toolkit. X-ray tubes with this kind of target material are used in diagnostic radiology, speci cally in mammography, one of the most used techniques for screening of breast cancer in women. During the simulations, we used di erent models for bremsstrahlung available in physical models for low energy, in situations already covered by the literature in earlier versions of Geant4. Our results show that although the physical situations seems qualitatively adequate, quantitative comparisons to available analytical data shows aws in the code of Geant4 Low Energy source

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effect of phloretin in the structure and hydration of dimiristoyl phosphatidylcholine vesicles (DMPC) was investigated by electron paramagnetic resonance technique (EPR) at the bilayer core of membrane, using 14-PCSL spin label derivative of phosphatidylcoline. The spectra obtained by pure DMPC vesicles and with addition of phloretin were simulated using the Nonlinear Least-Square program, at the tempearature between 15 oC to 50 oC. Through these simulations it was possible to analyse the membrane hydration and bilayer order, to understand the interaction between DMPC aggregates and phloretin. The results show that the phloretin decreases the membrane hydration in both gel and fluid phases. This reduction of water molecules is accompanied by increasing of the bilayer order at this micro-region

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The quality assurance control program (QACP) in clinical radiology is very important to acquire, image quality, patient dose reduction and cost for the institution. The verification of the real tension on the x ray tube, it is one of many parameters that may be determined on a QACP. This act on image quality as absorbed dose in patient. Once proved the importance of this fact, this study come up with the determination of tension to any X ray tube used on medical routine, on quick, safe and low cost manner. To reach the aim of this study, the methodology consisted on measuring expose rates (ER) using different thicknesses of copper (Cu) plates like filters and relating these results with Half Layer Value (HLV). Afterwards, the HLV was associated to real tension that was acquired with kilo voltage of peak (kVp) measurers used on clinical routine. So walking in this path, when performed the ER, on any X ray tube, it’s possible acquire the HLV and consequently the real kVp, considering measures obtained before, on the methodology of kVp estimative development

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A compreensão da epidemia do HIV e da AIDS em suas diferentes dimensões socioeconômica, cultural, biológica e política entre outras, representa um grande desafio para a Saúde Pública no Brasil e no mundo, desde o seu surgimento a cerca de duas décadas. Tanto na magnitude da propagação do HIV quanto na mortalidade por AIDS, reflete-se a crescente desigualdade entre países desenvolvidos e em desenvolvimento. Na medida em que se acentuam as diferenças de acesso ao tratamento, diminui a mortalidade por AIDS nos países mais ricos e aumenta nos países mais pobres, exceção feita ao Brasil, um dos poucos países que adotaram a política de distribuição gratuita de anti-retrovirais. Segue, no desenvolvimento deste trabalho, a análise do perfil epidemiológico da doença no município de Campinas-SP de acordo com a evolução do tratamento disponibilizado pelo Sistema Único de Saúde (SUS), utilizando o método de Regressão Logística segundo variáveis consideradas relevantes para o estudo e com base em parâmetros estimados a partir dessas variáveis

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Radiography is currently an important method of diagnosis, both medical, dental and veterinary. The image in this type of survey is obtained using an X-ray beam, where the radiologist can possibly view structures of interest. It isn't always possible to get the desired images due to various factors, such as equipment limitations. The Administrative Law 453/98, the State Resolution SS 625/94, and other standards require testing and quality control acceptance limits that guarantee a good performance of the equipment for the security and quality of care, giving service users greater effectiveness in exams. This study were performed in the accompaniment of testing procedures for quality control established by Administrative Law 453/98 in several X-ray equipment to make a comparison and optimization in the descriptions of the procedures used by the Institute for Electrical Energy and the University of São Paulo (IEE / USP / SP).The optimization of the procedures were performed with the aid of a current literature, the Resolution 453/98, State Resolution SS 625/94 and other international standards. On this basis it was possible to observe the importance of regular monitoring of tests for an update, following the technological development of instruments used in the service

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service