922 resultados para Eye Drops


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eye tracking as an interface to operate a computer is under research for a while and new systems are still being developed nowadays that provide some encouragement to those bound to illnesses that incapacitates them to use any other form of interaction with a computer. Although using computer vision processing and a camera, these systems are usually based on head mount technology being considered a contact type system. This paper describes the implementation of a human-computer interface based on a fully non-contact eye tracking vision system in order to allow people with tetraplegia to interface with a computer. As an assistive technology, a graphical user interface with special features was developed including a virtual keyboard to allow user communication, fast access to pre-stored phrases and multimedia and even internet browsing. This system was developed with the focus on low cost, user friendly functionality and user independency and autonomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To analyze dry eye disease (DED) tests and their consistency in similar nonsymptomatic population samples living in two geographic locations with different climates (Continental vs. Atlantic). Methods. This is a pilot study including 14 nonsymptomatic residents from Valladolid (Continental climate, Spain) and 14 sex-matched and similarly aged residents from Braga (Atlantic climate, Portugal); they were assessed during the same season (spring) of two consecutive years. Phenol red thread test, conjunctival hyperemia, fluorescein tear breakup time, corneal and conjunctival staining, and Schirmer test were evaluated on three different consecutive visits. Reliability was assessed using the intraclass correlation coefficient and weighted kappa (J) coefficient for quantitative and ordinal variables, respectively. Results. Fourteen subjects were recruited in each city with a mean (TSD) age of 63.0 (T1.7) and 59.1 (T0.9) years (p = 0.08) in Valladolid and Braga, respectively. Intraclass correlation coefficient and J values of the tests performed were below 0.69 and 0.61, respectively, for both samples, thus showing moderate to poor reliability. Subsequently, comparisons were made between the results corresponding to the middle and higher outdoor relative humidity (RH) visit in each location as there were no differences in mean temperature (p Q 0.75) despite RH values significantly differing (p e 0.005). Significant (p e 0.05) differences were observed between Valladolid and Braga samples on tear breakup time (middle RH visit, 2.76 T 0.60 vs. 5.26 T 0.64 seconds; higher RH visit, 2.61 T 0.32 vs. 5.78 T 0.88 seconds) and corneal (middle RH, 0.64 T 0.17 vs. 0.14 T 0.10; higher RH, 0.60 T 0.22 vs. 0.0 T 0.0) and conjunctival staining (middle RH, 0.61 T 0.17 vs. 0.14 T 0.08; higher RH, 0.57 T 0.15 vs. 0.18 T 0.09). Conclusions. This pilot study provides initial evidence to support that DED test outcomes assessing the ocular surface integrity and tear stability are climate dependent. Future large-sample studies should support these outcomes also in DED patients. This knowledge is fundamental for multicenter clinical trials. Lack of consistency in diagnostic clinical tests for DED was also corroborated. (Optom Vis Sci 2015;92:e284Ye289)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to advance blinking detection in the context of work activity. Rather than patients having to attend a clinic, blinking videos can be acquired in a work environment, and further automatically analyzed. Therefore, this paper presents a methodology to perform the automatic detection of eye blink using consumer videos acquired with low-cost web cameras. This methodology includes the detection of the face and eyes of the recorded person, and then it analyzes the low-level features of the eye region to create a quantitative vector. Finally, this vector is classified into one of the two categories considered —open and closed eyes— by using machine learning algorithms. The effectiveness of the proposed methodology was demonstrated since it provides unbiased results with classification errors under 5%

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare pattern of exploratory eye movements during visual scanning of the Rorschach and TAT test cards in people with schizophrenia and controls. METHOD: 10 participants with schizophrenia and 10 controls matched by age, schooling and intellectual level participated in the study. Severity of symptoms was evaluated with the Positive and Negative Syndrome Scale. Test cards were divided into three groups: TAT cards with scenes content, TAT cards with interaction content (TAT-faces), and Rorschach cards with abstract images. Eye movements were analyzed for: total number, duration and location of fixation; and length of saccadic movements. RESULTS: Different pattern of eye movement was found, with schizophrenia participants showing lower number of fixations but longer fixation duration in Rorschach cards and TAT-faces. The biggest difference was observed in Rorschach, followed by TAT-faces and TAT-scene cards. CONCLUSIONS: Results suggest alteration in visual exploration mechanisms possibly related to integration of abstract visual information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Média Interativos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In March 2004, the Scottish government announced a review of eye care services in Scotland, which culminated in the introduction of free eye examinations from 1st April 2006. This free eye examination is not just a sight test; it is a thorough examination to check the health of the patient’s eyes and to look for signs of other health problems. The Scottish government commissioned private ophthalmic optician practices to perform these eye examinations. Consequently, since April 2006 individuals in Scotland could walk into any high street optometry practice and get a ‘free’ eye examination funded under the NHS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 22-year-old man after severe cranial trauma, who was noted to have conjugate eye deviation (CED) to the left. A magnetic resonance imaging (MRI) scan demonstrated a lesion in the left (ipsilateral) striatal-subthalamic region. The involvement of supranuclear fibres from the left frontal eye field (FEF) traveling to the right parapontine reticular formation (PPRF) could explain this clinical finding. Alternatively, involvement of deep brain nuclei, such as the striatum and the subthalamic nucleus, could be responsible for this phenomenon. This neurological presentation is unusual after severe cranial trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous solutions of the molluscicidal latex of Euphorbia splendens are irritant to the rabbit eye in concentrations higher than 0.35% and to the rabbit skin in concentrations higher than 0.5%. Although this irritant potential does not proclude its use as a molluscicide, special precautions are recommended for hanbdling and application of the product and the hazard of skin tumor-promoting potencial should be carefully investigated before its use for schistosomiasis vector control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the eye's specific anatomical and physiological conformation, the treatment of eye diseases is a real challenge for pharmaceutical therapy. The presence of efficient protective barriers (i.e., the conjunctival and corneal membranes) and protective mechanisms (i.e., blinking and nasolachrymal drainage) makes this organ particularly impervious to local drug therapy. To overcome these issues, numerous strategies have been envisioned using pharmaceutical technology. Many formulations currently on the market or still under development are emulsions or colloidal systems intended to enhance precorneal residence time and corneal penetration, causing a consequent increase in drug bioavailability after instillation. After a review of some recent developments in the field of cyclosporin A formulations for the eye, a novel micellar formulation of cyclosporine A based on a diblock methoxy-poly(ethylene glycol)-hexysubstituted poly(lactides) (MPEG-hexPLA) is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les résultats préliminaires de trois essais cliniques de thérapie génique d'une forme agressive de rétinite pigmentaire (l'amaurose congénitale de Leber) ont prouvé que le traitement des maladies dégénératives de la rétine par transfert de gène peut être sûr et efficace pour rétablir une fonction visuelle. Il faudra encore attendre les résultats à long terme de ces études pour que soit définitivement validée cette approche thérapeutique. Dans l'intervalle, il importe de se préparer à son introduction en ophtalmologie de façon à la rendre accessible à nos malades. Pratiquement cela revient à promouvoir: 1) le recrutement; 2) la caractérisation du phénotype et du génotype des sujets atteints et 3) la constitution d'un registre des rétinopathies héréditaires. Recently, preliminary results of three clinical gene therapy trials for early onset retinitis pigmentosa--Leber congenital amaurosis--suggested that treating this degenerative retinal disease by gene transfection can be safe and efficient to restore a visual function. The definitive validation of this therapeutic approach depends on the long-term results. The forthcoming availability of gene therapy in ophthalmology prompts the implementation: of 1) recruitment, 2) phenotyping and genotyping of affected patients, 3) and creation of a hereditary retinopathy registry.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.