1000 resultados para Ethyl Alcohol


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the development and prognosis of alcohol-induced liver disease (ALD) vary significantly with genetic background, identification of a genetic background-independent noninvasive ALD biomarker would significantly improve screening and diagnosis. This study explored the effect of genetic background on the ALD-associated urinary metabolome using the Ppara-null mouse model on two different backgrounds, C57BL/6 (B6) and 129/SvJ (129S), along with their wild-type counterparts. Reversed-phase gradient UPLC-ESI-QTOF-MS analysis revealed that urinary excretion of a number of metabolites, such as ethylsulfate, 4-hydroxyphenylacetic acid, 4-hydroxyphenylacetic acid sulfate, adipic acid, pimelic acid, xanthurenic acid, and taurine, were background-dependent. Elevation of ethyl-β-d-glucuronide and N-acetylglycine was found to be a common signature of the metabolomic response to alcohol exposure in wild-type as well as in Ppara-null mice of both strains. However, increased excretion of indole-3-lactic acid and phenyllactic acid was found to be a conserved feature exclusively associated with the alcohol-treated Ppara-null mouse on both backgrounds that develop liver pathologies similar to the early stages of human ALD. These markers reflected the biochemical events associated with early stages of ALD pathogenesis. The results suggest that indole-3-lactic acid and phenyllactic acid are potential candidates for conserved and pathology-specific high-throughput noninvasive biomarkers for early stages of ALD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The analysis of ethyl glucuronide (EtG), a marker of recent alcohol consumption, in serum with an optimized CZE assay is reported. The method uses a 0.1-mm id fused-silica capillary of 50 cm effective length that is coated with linear polyacrylamide, a pH 4.4 nicotinic acid/epsilon-aminocaproic acid (EACA) BGE, reversed polarity and indirect analyte detection. The assay is based on a 1:1 dilution of serum with deionized water and has LODs for EtG, lactate and acetate of 3.8 x 10(-7) M, 2.60 x 10(-6 )M and 2.18 x 10(-6 )M, respectively. Separation of EtG from endogenous macro- and microcomponents (anionic serum components of high and low concentration, respectively) and its quantification are shown to be possible for a wide range of lactate (stacker) and acetate (destacker) concentrations, macrocomponents that have an impact on the CZE behavior of EtG and that change after intake of ethanol. The assay has been successfully applied to the analysis of EtG, lactate and acetate in (i) sera of volunteers that ingested known amounts of alcohol and (ii) samples of patients that were classified (teetotalers and social drinkers vs. alcohol abusers) via analysis of carbohydrate-deficient transferrin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of capillary zone electrophoresis (CZE) with indirect absorbance detection for the analysis of ethyl sulfate (EtS) in serum and urine was investigated. EtS is a direct metabolite of ethanol employed as marker for recent alcohol consumption. Fused-silica capillaries of 60 cm total length were either coated with cetyltrimethylammonium bromide (CTAB, 50 microm I.D. capillary) or poly(diallyldimethylammonium chloride) (PDADMAC, 100 microm I.D. capillary) to allow CZE analyses to be performed with reversed polarity. At pH 2.2 with a maleic acid/phthalic acid background electrolyte, both approaches provided reliable EtS serum levels down to 0.2 mg L(-1) (1.6 microM) for the analysis of solid-phase extracts that were prepared after chloride precipitation. Analysis of urines diluted to a conductivity of 5 S m(-1) and analyzed in the two capillary formats resulted in limits of quantification (LOQs) of 2 and 1 mg L(-1), respectively. With urines adjusted to 10 S m(-1) via dilution or condensation, an LOQ of 0.6 mg L(-1) (4.8 microM) was obtained in the CTAB coated capillary whereas in the PDADMAC-coated capillary of equal length not all matrix components were resolved from EtS. The developed assays are robust and suitable to monitor EtS in samples of individuals who consumed as little as one standard drink of an alcoholic beverage containing about 14 g of ethanol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ethyl glucuronide (EtG) is a marker of recent alcohol consumption. For the optimization of the analysis of EtG by CZE with indirect absorbance detection, the use of capillaries with permanent and dynamic wall coatings, the composition of the BGE, and various sample preparation procedures, including dilution with water, ultrafiltration, protein precipitation, and SPE, were investigated. Two validated screening assays for the determination of EtG in human serum, a CZE-based approach and an enzyme immunoassay (EIA), are described. The CZE assay uses a coated capillary, 2,4-dimethylglutaric acid as an internal standard, and a pH 4.65 BGE comprising 9 mM nicotinic acid, epsilon-aminocaproic acid and 10% v/v ACN. Proteins are removed via precipitation with ACN prior to analysis and the LOQ is 0.50 mg/L. The EIA is based upon commercial reagents which are promoted for the determination of urinary EtG. Krebs-Ringer solution containing 5% BSA is used as a calibration matrix. All samples are ultrafiltered prior to analysis of the ultrafiltrate on a Mira Plus analyzer. Assay calibration ranged between 0 and 2 mg/L and the upper reference limit was determined to be 0.05 mg/L. Both assays proved to be suitable for the analysis of samples from different individuals. For EtG levels above 0.50 mg/L, good agreement was observed for the comparison of the results of the two methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Monitoring alcohol use is important in numerous situations. Direct ethanol metabolites, such as ethyl glucuronide (EtG), have been shown to be useful tools in detecting alcohol use and documenting abstinence. For very frequent or continuous control of abstinence, they lack practicability. Therefore, devices measuring ethanol itself might be of interest. This pilot study aims at elucidating the usability and accuracy of the cellular photo digital breathalyzer (CPDB) compared to self-reports in a naturalistic setting. Method: 12 social drinkers were included. Subjects used a CPDB 4 times daily, kept diaries of alcohol use and submitted urine for EtG testing over a period of 5 weeks. Results: In total, the 12 subjects reported 84 drinking episodes. 1,609 breath tests were performed and 55 urine EtG tests were collected. Of 84 drinking episodes, CPDB detected 98.8%. The compliance rate for breath testing was 96%. Of the 55 EtG tests submitted, 1 (1.8%) was positive. Conclusions: The data suggest that the CPDB device holds promise in detecting high, moderate, and low alcohol intake. It seems to have advantages compared to biomarkers and other Monitoring devices. The preference for CPDB by the participants might explain the high compliance. Further studies including comparison with biomarkers and transdermal devices are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for These parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Work dealing with the monitoring of alcohol markers by CE performed during the past two decades led to the development of assays for carbohydrate-deficient transferrin (CDT), ethyl sulfate, ethyl glucuronide, and phosphatidylethanol in body fluids and first attempts for the detection of the urinary 5-hydroxytryptophol/5-hydroxyindoleacetic acid ratio and stable hemoglobin acetaldehyde adducts. Most notably are assays for CDT that have been commercialized and are being used in many laboratories under routine conditions. This paper provides insight into the development, specifications, and use of the currently known CE-based assays suitable to detect alcohol markers. The achievements reached so far indicate that CE is an attractive technology for monitoring alcohol markers. This is particularly seen with the CDT assays that do not require an elaborate sample pretreatment and thus could be fully automated for high-throughput analyses on multicapillary instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Alcohol-related disorders are common, expensive in their course, and often underdiagnosed. To facilitate early diagnosis and therapy of alcohol-related disorders and to prevent later complications, questionnaires and biomarkers are useful. METHODS Indirect state markers like gamma-glutamyl-transpeptidase, mean corpuscular volume, and carbohydrate deficient transferrin are influenced by age, gender, various substances, and nonalcohol-related illnesses, and do not cover the entire timeline for alcohol consumption. Ethanol (EtOH) metabolites, such as ethyl glucuronide, ethyl sulfate, phosphatidylethanol, and fatty acid ethyl esters have gained enormous interest in the last decades as they are detectable after EtOH intake. RESULTS For each biomarker, pharmacological characteristics, detection methods in different body tissues, sensitivity/specificity values, cutoff values, time frames of detection, and general limitations are presented. Another focus of the review is the use of the markers in special clinical and forensic samples. CONCLUSIONS Depending on the biological material used for analysis, ethanol metabolites can be applied in different settings such as assessment of alcohol intake, screening, prevention, diagnosis, and therapy of alcohol use disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The forensic utility of fatty acid ethyl esters (FAEEs) in dried blood spots (DBS) as short-term confirmatory markers for ethanol intake was examined. An LC-MS/MS method for the determination of FAEEs in DBS was developed and validated to investigate FAEE formation and elimination in a drinking study, whereby eight subjects ingested 0.66-0.84 g/kg alcohol to reach blood alcohol concentrations (BAC) of 0.8 g/kg. Blood was taken every 1.5-2 h, BAC was determined, and dried blood spots were prepared, with 50 μL of blood, for the determination of FAEEs. Lower limits of quantitation (LLOQ) were between 15 and 37 ng/mL for the four major FAEEs. Validation data are presented in detail. In the drinking study, ethyl palmitate and ethyl oleate proved to be the two most suitable markers for FAEE determination. Maximum FAEE concentrations were reached in samples taken 2 or 4 h after the start of drinking. The following mean peak concentrations (c̅ max) were reached: ethyl myristate 14 ± 4 ng/mL, ethyl palmitate 144 ± 35 ng/mL, ethyl oleate 125 ± 55 ng/mL, ethyl stearate 71 ± 21 ng/mL, total FAEEs 344 ± 91 ng/mL. Detectability of FAEEs was found to be on the same time scale as BAC. In liquid blood samples containing ethanol, FAEE concentrations increase post-sampling. This study shows that the use of DBS fixation prevents additional FAEE formation in blood samples containing ethanol. Positive FAEE results obtained by DBS analysis can be used as evidence for the presence of ethanol in the original blood sample. Graphical Abstract Time courses for fatty acid ethyl ester (FAEE) concentrations in DBS and ethanol concentrations for subject 1 over a period of 7 h. Ethanol ingestion occured during the first hour of the time course.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For driving aptitude assessment (DAA), the analysis of several alcohol biomarkers is essential for the detection of alcohol intake besides psycho-medical exploration. In Switzerland, EtG in hair (hEtG) is often the only direct marker for abstinence monitoring in DAA. Therefore, the suitability of phosphatidylethanol (PEth) was investigated as additional biomarker. PEth 16:0/18:1 and 16:0/18:2 were determined by online-SPE-LC-MS/MS in 136 blood samples of persons undergoing DAA and compared to hEtG, determined in hair segments taken at the same time. With a PEth 16:0/18:1 threshold of 210 ng/mL for excessive alcohol consumption, all (n = 30) but one tested person also had hEtG values ≥30 pg/mg. In 54 cases, results are not in contradiction to an abstinence as neither PEth (<20 ng/mL) nor hEtG (<7 pg/mg) was detected. In eight cases, both markers showed moderate consumption. Altogether, PEth and hEtG were in accordance in 68 % of the samples, although covering different time periods of alcohol consumption. With receiver operating characteristic analysis, PEth was evaluated to differentiate abstinence, moderate, and excessive alcohol consumption in accordance with hEtG limits. A PEth 16:0/18:1 threshold of 150 ng/mL resulted in the best sensitivity (70.6 %) and specificity (98.8 %) for excessive consumption. Values between 20 and 150 ng/mL passed for moderate consumption, values <20 ng/mL passed for abstinence. As PEth mostly has a shorter detection window (2-4 weeks) than hEtG (up to 6 months depending on hair length), changes in drinking behavior can be detected earlier by PEth than by hEtG analysis alone. Therefore, PEth helps to improve the diagnostic information and is a valuable additional alcohol marker for DAA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate associations between polymorphisms of the N-acetyltransferase 2 (NAT2), human 8-oxoguanine glycosylase 1 (hOGG1) and X-ray repair cross-complementing protein 1 (XRCC1) genes and risk of upper aerodigestive tract (UADT) cancer. A case-control study involving 117 cases and 224 controls was undertaken. The NAT2 gene polymorphisms were genotyped by automated sequencing and XRCC1 Arg399Gln and hOGG1 Ser326Cys polymorphisms were determined by Polymerase Chain Reaction followed by Restriction Fragment Length Polymorphism (PCR-RFLP) methods. Slow metabolization phenotype was significantly associated as a risk factor for the development of UADT cancer (p=0.038). Furthermore, haplotype of slow metabolization was also associated with UADT cancer (p=0.014). The hOGG1 Ser326Cys polymorphism (CG or GG vs. CC genotypes) was shown as a protective factor against UADT cancer in moderate smokers (p=0.031). The XRCC1 Arg399Gln polymorphism (GA or AA vs. GG genotypes), in turn, was a protective factor against UADT cancer only among never-drinkers (p=0.048). Interactions involving NAT2, XRCC1 Arg399Gln and hOGG1 Ser326Cys polymorphisms may modulate the risk of UADT cancer in this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pathological conditions associated with the impairment of nitric oxide (NO) production in the vasculature, such as Raynaud's syndrome and diabetic angiopathy, have stimulated the development of new biomaterials capable of delivering NO topically. With this purpose, we modified poly(vinyl-alcohol) (PVA) by chemically crosslinking it via esterification with mercaptosuccinic acid. This reaction allowed the casting of sulfhydrylated PVA (PVA-SH) films. Differential scanning calorimetry and X-ray diffractometry showed that the crosslinking reaction completely suppressed the crystallization of PVA, leading to a non-porous film with a homogeneous distribution of -SH groups. The remaining free hydroxyl groups in the PVA-SH network conferred partial hydrophylicity to the material, which was responsible for a swelling degree of ca. 110%. The PVA-SH films were subjected to an S-nitrosation reaction of the -SH groups, yielding a PVA containing S-nitrosothiol groups (PVA-SNO). Amperometric and chemiluminescence measurements showed that the PVA-SNO films were capable of releasing NO spontaneously after immersion in physiological medium. Laser Doppler-flowmetry, used to assess the blood flow in the dermal microcirculation, showed that the topical application of hydrated PVA-SNO films on the health skin led to a dose- and time-dependent increase of more than 5-fold in the dermal baseline blood flow in less than 10min, with a prolonged action of more than 4h during continuous application. These results show that PVA-SNO films might emerge as a new material with potential for the topical treatment of microvascular skin disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the degree of conversion (DC) and the cytotoxicity of photo-cured experimental resin composites containing 4-(N,N-dimethylamino)phenethyl alcohol (DMPOH) combined to the camphorquinone (CQ) compared with ethylamine benzoate (EDAB). The resin composites were mechanically blended using 35 wt% of an organic matrix and 65 wt% of filler loading. To this matrix was added 0.2 wt% of CQ and 0.2 wt% of one of the reducing agents tested. 5x1 mm samples (n=5) were previously submitted to DC measurement and then pre-immersed in complete culture medium without 10% (v/v) bovine serum for 1 h or 24 h at 37 °C in a humidifier incubator with 5% CO2 and 95% humidity to evaluate the cytotoxic effects of experimental resin composites using the MTT assay on immortalized human keratinocytes cells. As a result of absence of normal distribution, the statistical analysis was performed using the nonparametric Kruskal-Wallis to evaluate the cytotoxicity and one-way analysis of variance to evaluate the DC. For multiple comparisons, cytotoxicity statistical analyses were submitted to Student-Newman-Keuls and DC analysis to Tukey's HSD post-hoc test (=0.05). No significant differences were found between the DC of DMPOH (49.9%) and EDAB (50.7%). 1 h outcomes showed no significant difference of the cell viability between EDAB (99.26%), DMPOH (94.85%) and the control group (100%). After 24 h no significant difference were found between EDAB (48.44%) and DMPOH (38.06%), but significant difference was found compared with the control group (p>0.05). DMPOH presented similar DC and cytotoxicity compared with EDAB when associated with CQ.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to study the effect of the hydrolysis degree (HD) and the concentration (C PVA) of two types of poly (vinyl alcohol) (PVA) and the effect of the type and the concentration of plasticizers on the phase properties of biodegradable films based on blends of gelatin and PVA, using a response-surface methodology. The films were made by casting and the studied properties were their glass (Tg) and melting (Tm) transition temperatures, which were determined by diferential scanning calorimetry (DSC). For the data obtained on the first scan, the fitting of the linear model was statistically significant and predictive only for the second melting temperature. In this case, the most important effect on the second Tm of the first scan was due to the HD of the PVA. In relation to the second scan, the linear model could be fit to Tg data with only two statistically significant parameters. Both the PVA and plasticizer concentrations had an important effect on Tg. Concerning the second Tm of the second scan, the linear model was fit to data with two statistically significant parameters, namely the HD and the plasticizer concentration. But, the most important effect was provoked by the HD of the PVA.