593 resultados para Esophageal intramural pseudodiverticulosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two healthy cats underwent elective surgical procedures under general anesthesia. One developed severe esophagitis leading to esophageal rupture, mediastinitis, and pyothorax. The other cat developed esophageal stricture, diverticulum formation, and suspected iatrogenic perforation. Both cats had signs of dysphagia and regurgitation beginning a few days after anesthesia. The first cat also had severe dyspnea due to septic pleural effusion and pneumomediastinum. In the second cat, endoscopy revealed diffuse esophagitis, an esophageal stricture, and a large esophageal diverticulum. Rupture of the esophageal wall occurred while inflating the esophagus for inspection. Due to the poor prognosis, both cats were euthanized. Necropsy revealed severe esophageal changes. Postanesthetic esophagitis has been previously described in dogs and cats; however, severe life-threatening esophageal injuries rarely occur as a sequel to general anesthesia. To the authors' knowledge, esophageal rupture secondary to perianesthetic reflux has never been reported in cats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three horses (age 17 - 23 years) were referred to the equine clinic of the University of Berne due to colic, fever, tachycardia and tachypnea. All horses showed pleural effusion. Clinical findings in 2 of the horses were highly suggestive of an intra-thoracic esophageal perforation. Severe septic pleuropneumonia without suspicion of an esophageal lesion was diagnosed in the 3rd horse. In addition, an 11 year old stallion was referred to the equine clinic for treatment of a presumptive large colon impaction. The horse was given laxatives after nasogastric intubation. Subsequent dramatic clinical deterioration and signs consistent with severe pleuropneumonia suggest that esophageal perforation had occurred when passing the nasogastric tube. All 4 horses were euthanized due to a poor prognosis. Esophageal perforation was diagnosed or confirmed post mortem in all cases. A hypertrophy of the tunica muscularis of the intra-thoracic esophagus was found in 3 of 4 horses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alterations of the epidermal growth factor receptor (EGFR) can be observed in a significant subset of esophageal adenocarcinomas (EACs), and targeted therapy against EGFR may become an interesting approach for the treatment of these tumors. Mutations of KRAS, NRAS, BRAF, and phosphatidylinositol-3-kinase catalytic subunit (PIK3CA) and deregulation of PTEN expression influence the responsiveness against anti-EGFR therapy in colorectal carcinomas. We investigated the prevalence of these events in a collection of 117 primary resected EACs, correlated the findings with EGFR expression and amplification, and determined their clinicopathologic impact. KRAS mutations were detected in 4 (3%) of 117 tumors (3× G12D and 1 G12V mutation). One tumor had a PIK3CA E545K mutation. Neither NRAS nor BRAF mutations were detected. Sixteen (14%) of 117 cases were negative for PTEN expression, determined by immunohistochemistry. Loss of PTEN was observed predominantly in advanced tumor stages (P = .004). There was no association between PTEN and EGFR status. Loss of PTEN was associated with shorter overall and disease-free survival (P < .001 each) and also an independent prognostic factor in multivariate analysis (P = .015). EGFR status had no prognostic impact in this case collection. In summary, loss of PTEN can be detected in a significant subset of EAC and is associated with an aggressive phenotype. Therefore, PTEN may be useful as a prognostic biomarker. In contrast, mutations of RAS/RAF/PIK3CA appear only very rarely, if at all, in EAC. A possible predictive role of PTEN in anti-EGFR treatment warrants further investigations, whereas determination of RAS/RAF/PIK3CA mutations may only have a minor impact in this context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most common techniques to perform stellate ganglion blocks (SGBs) are the blind C6 approach and the fluoroscopic-controlled paratracheal C7 approach, both after manual dislocation of the large vessels. Complications due to vascular or esophageal puncture have been reported. The goal of this ultrasound imaging study was to determine how frequently hazardous structures are located along the needle path of conventional SGB and to determine the influence of the dislocation maneuver on their position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esophageal motility abnormalities include a series of manometric findings that differ to a significant degree from findings in normal, asymptomatic volunteers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Chicago Classification of esophageal motility was developed to facilitate the interpretation of clinical high resolution esophageal pressure topography (EPT) studies, concurrent with the widespread adoption of this technology into clinical practice. The Chicago Classification has been an evolutionary process, molded first by published evidence pertinent to the clinical interpretation of high resolution manometry (HRM) studies and secondarily by group experience when suitable evidence is lacking.