924 resultados para Equipment, laryngeal mask


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel read-only memory (ROM) disk with an AgOx mask layer was proposed and studied in this letter. The AgOx films sputtered on the premastered substrates, with pits depth of 50 nm and pits length of 380 nm, were studied by an atomic force microscopy. The transmittances of these AgOx films were also measured by a spectrophotometer. Disk measurement was carried out by a dynamic setup with a laser wavelength of 632.8 nm and a lens numerical aperture (NA) of 0.40. The readout resolution limit of this setup was λ/(4NA) (400 nm). Results showed that the super-resolution readout happened only when the oxygen flow ratios were at suitable values for these disks. The best super-resolution performance was achieved at the oxygen flow ratio of 0.5 with the smoothest film surface. The super-resolution readout mechanism of these ROM disks was analyzed as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Static recording characteristic of super-resolution near-field structure with antimony (Sb) is investigated in this paper. The recording marks are observed by a scanning electron microscopy (SEM), a high-resolution optical microscopy with a CCD camera and an atomic force microscopy (AFM). The super-resolution mechanism is also analyzed based on these static recording marks. Results show that the light reaching on recording layer is composed of two parts, one is the linear transmissive light (propagating field) and the other is the nonlinear evanescent light in the optical near field. The evanescent light may be greatly enhanced in the center of the spot because Sb will transit from a semiconductor to a metal when it is melted under the high laser power irradiation. This local melted area in the spot center may be like a metal tip in the optical near field that can collect and enhance the information that is far beyond the diffraction limit, which leads to the super-resolution recording and readout. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two novel read-only memory (ROM) disks, one with an AgOx mask layer and the other with an AgInSbTe mask layer, are proposed and studied. The AgOx and the AgInSbTe films sputtered on the premastered substrates with pit depths of 50 nm and pit lengths (space) of 380 nm are studied by atomic force microscopy. Disk readout measurement is carried out using a dynamic setup with a laser wavelength of 632.8 nm and an object lens numerical aperture (NA) of 0.40. Results show that the superresolution effect happens only at a suitable oxygen flow ratio for the AgOx ROM disk. The best superresolution readout effect is achieved at an oxygen flow ratio of 0.5 with the smoothest film surface. Compared with the AgOx ROM disk, the AgInSbTe ROM disk has a much smoother film surface and better superresolution effect. A carrier-to-noise ratio (CNR) of above 40 dB can be obtained at an appropriate readout power and readout velocity. The readout CNR of both the AgOx and AgInSbTe ROM disks have a nonlinear dependence on the readout power. The superresolution readout mechanisms for these ROM disks are analyzed and compared as well. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sb-Bi alloy films are proposed as a new kind of super-resolution mask layer with low readout threshold power. Using the Sb-Bi alloy film as a mask layer and SiN as a protective layer in a read-only memory disc, the super-resolution pits with diameters of 380 nm are read out by a dynamic setup, the laser wavelength is 780 nm and the numerical aperture of pickup lens is 0.45. The effects of the Sb-Bi thin film thickness, laser readout power and disc rotating velocity on the readout signal are investigated. The results show that the threshold laser power of super-resolution readout of the Sb-Bi mask layer is about 0.5 mW, and the corresponding carrier-to-noise ratio is about 20 dB at the film thickness of 50 nm. The super-resolution mechanism of the Sb-Bi alloy mask layer is discussed based on its temperature dependence of reflection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The document reports on the major findings from a definition study to appraise the options to develop fish tracking equipment, in particular tags and data logging systems, in order to improve the effeciency of the Agency tracking studies and to obtain a greater understanding of fish biology. The definition study was in two parts. The first, Phase 1, collated and evaluated all the known tracking systems that may be suitable for studies of fish which are either produced commercially or have been constructed for specific in-house studies. Phase 2 was an evaluation of all the tracking equipment considered to merit further investigation in Phase 1. The deficiencies between existing and required technologies to improve the efficiency of Agency's tracking studies and to obtain a greater understanding of fish biology are also identified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

按照高斯型渐变反射率镜(GRM)的参数要求,采用了中间层厚度渐变的方案对膜系和掩模板形状进行设计.根据薄膜的实际需求和具体的沉积设备,设计了掩模和掩模切换装置.在一次高真空环境下镀制了渐变反射率镜的所有膜系.采用直接测量的方法,测量了高斯型渐变反射率镜反射率的径向分布.测试结果表明,用这种技术制备的样品,与设计要求基本一致.分析得出,掩模板形状与精度对镀制结果有影响.随着设计尺寸减小,掩模板对膜料分子的散射作用增强,使样品中心反射率小于设计要求,边缘出现旁瓣.提出了减小基片与掩模板之间的距离和提高膜厚监控的精度的改善方案.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the parameter requirements of a graded reflectivity mirror with a Gaussian profile, the layer structure and the mask pattern are designed using a graded-thickness middle layer. The mask and the automatic mask-switchover equipment are designed considering the actual requirement of the thin films and the specific deposit facility. The uniformity of the layer thickness is analyzed. The measurement results indicate that samples prepared with this technique are basically in accordance with the design parameter. The scattering effect between the material molecules and the mask, thickness errors, and the alignment error between the mask and the substrate are the main factors that influence the deposit result. (c) 2008 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3027595]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The report looks at experiments into electric fishing equipment and effects on salmon and trout within the Lancashire River Board. Experiments include obtaining information on voltage gradients, ascertaining what damage to fish of the larger size groups resulted from electric fishing, determining whether or not fractures could occur in coarse fish and brown trout,similar to those occurring in salmon and sea trout, and effects low temperatures have on electrofishing techniques.