975 resultados para Electroencephalogram(ECG)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent work with P-36 demonstrates that the replacement of the last two doses of Follicle-Stimulating Hormone (FSH) with equine chorionic gonadotropin (eCG) increases embryo yields. However, it is unclear if the positive effect of eCG is related to its FSH-like activity, LH-like activity, or both. This study aimed to verify the replacement of eCG with pLH on the last day of superstimulatory treatment. Twenty-five Nelore cows were allocated to four groups: P-36 (control), P-36/eCG, P-36/LH2, and P-36/LH4. All animals underwent four treatments in a crossover design. The control group cows were superstimulated with decreasing doses of porcine Follicle-Stimulating Hormone (pFSH, 133 mg, im). In the P-36/eCG, P-36/LH2, and P-36/LH4 groups, the last two doses of pFSH were replaced in the former group by two doses of eCG (200 IU each dose, im) and in the latter two groups by two doses of pLH (1 and 2 mg each dose, im), respectively. Donors received fixed-time artificial insemination 12 and 24 hours after pLH. Embryo flushing was performed on D16. Data were analyzed by ANOVA (Proc Mixed, SAS). There was a trend of decreasing ovulation rate when comparing groups LH2 and eCG (P = 0.06). However, there was no significant difference in the mean number of viable embryos among groups P-36 (3.3 ± 0.7), P-36/eCG (4.5 ± 0.5), P-36/LH2 (3.7 ± 0.8), and P-36/LH4 (4.2 ± 1.0). It is concluded that the replacement of eCG by pLH on the last day of superstimulatory treatment can be performed with no significant variation in the production of viable embryos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

È nata la necessità di trasferire nell’abitazione del paziente il percorso terapeutico, realizzando forme di assistenza a domicilio, che evitino da un lato il disagio dell’accesso alle strutture specialistiche, dall’altro che consentano di ridurre il carico di pazienti gestiti direttamente dalle strutture ospedaliere. Questi servizi sono in grado di favorire una delocalizzazione delle cure, decongestionando ospedali ed ambulatori. Questi sistemi di monitoraggio potranno così aiutare a risolvere una delle principali criticità del nostro servizio sanitario, ovvero la lunghezza delle liste d'attesa per le visite ambulatoriali,e contribuire a ridurre le spese per la loro erogazione. Nel mio elaborato discuto e analizzo due dispositivi in particolare il sensore BioHarness BH3 ed un prodotto innovativo studiato in Italia la MagIc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patient with an SCN5A p.W822X nonsense mutation, localized in the transmembrane region DII-S4 of the Na(v)1.5 sodium channel and leading to a non-expression of the mutant allele, was prescribed the selective serotonin reuptake inhibitor (SSRI) fluvoxamine (Floxyfral), 100 mg per day. His normal baseline ECG changed to a characteristic Brugada-Type-1-ECG pattern. To investigate whether fluvoxamine may reduce the cardiac sodium current, the effect of this drug was studied on the wild-type voltage-gated cardiac sodium channel Na(v)1.5 stably expressed in HEK293 cells. Patch-clamp recording showed a 50% inhibition of the current at a concentration of 57.3 microM. In our patient, no arrhythmia occurred but the proarrhythmic potential of SSRI in patients with SCN5A mutations cannot be excluded. Therefore, we advise 12-lead ECG control after administering SSRI in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Diagnosing arrhythmias by conventional Holter-ECG can be cumbersome because of artifacts, skin irritation and poor P-waves. In contrast, esophageal electrocardiography (eECG) is promising due to the anatomic relationship of the esophagus to the atria and its favorable bioelectric properties. Methods used: In an ambulant setting, we recorded eECGs from 10 volunteers with a novel, highly-miniaturized eECG recorder that is worn discretely behind the ear (1.5×1.8×5cm, 22grams). The device continuously records two eECG leads during 3 days with 500Hz sampling frequency and 24-bit resolution. Results: Mean ± SD recording time was 21.7±19.6 hours (max. 60 hours). Test persons were not limited in daily activities (e.g. eating, speaking) and only complained mild discomfort during probe insertion, which subsided later on. During 99.8% of time, the recorder acquired signals appropriate for further analysis. In unfiltered data, QRS complexes and P-waves were identifiable during >98% of time. P waves had higher amplitudes as compared to surface ECG (0.71 ± 0.42mV vs. 0.16 ± 0.03mV, p = 0.004). No complications occurred. Conclusion: Ambulatory eECG recording is safe, well tolerated and promising due to excellent P-wave detection, overcoming some limitations of conventional Holter ECG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prolonged ECG monitoring is standard for atrial fibrillation (AF) screening. This study investigated whether 7-day event triggered (tECG) ECG recording is equivalent to 7-day continuous Holter (cECG) ECG recording for AF screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In populations of older adults, prediction of coronary heart disease (CHD) events through traditional risk factors is less accurate than in middle-aged adults. Electrocardiographic (ECG) abnormalities are common in older adults and might be of value for CHD prediction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Detection of arrhythmic atrial beats in surface ECGs can be challenging when they are masked by the R or T wave, or do not affect the RR-interval. Here, we present a solution using a high-resolution esophageal long-term ECG that offers a detailed view on the atrial electrical activity. The recorded ECG shows atrial ectopic beats with long coupling intervals, which can only be successfully classified using additional morphology criteria. Esophageal high-resolution ECGs provide this information, whereas surface long-term ECGs show poor atrial signal quality. This new method is a promising tool for the long-term rhythm monitoring with software-based automatic classification of atrial beats.