892 resultados para Electricity Network Distribution Wastes


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The next couple of years will see the need for replacement of a large amount of life-expired switchgear on the UK 11 kV distribution system. Latest technology and alternative equipment have made the choice of replacement a complex task. The authors present an expert system as an aid to the decision process for the design of the 11 kV power distribution network.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Smart meters are becoming more ubiquitous as governments aim to reduce the risks to the energy supply as the world moves toward a low carbon economy. The data they provide could create a wealth of information to better understand customer behaviour. However at the household, and even the low voltage (LV) substation level, energy demand is extremely volatile, irregular and noisy compared to the demand at the high voltage (HV) substation level. Novel analytical methods will be required in order to optimise the use of household level data. In this paper we briefly outline some mathematical techniques which will play a key role in better understanding the customer's behaviour and create solutions for supporting the network at the LV substation level.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper assesses the impact of the location and configuration of Battery Energy Storage Systems (BESS) on Low-Voltage (LV) feeders. BESS are now being deployed on LV networks by Distribution Network Operators (DNOs) as an alternative to conventional reinforcement (e.g. upgrading cables and transformers) in response to increased electricity demand from new technologies such as electric vehicles. By storing energy during periods of low demand and then releasing that energy at times of high demand, the peak demand of a given LV substation on the grid can be reduced therefore mitigating or at least delaying the need for replacement and upgrade. However, existing research into this application of BESS tends to evaluate the aggregated impact of such systems at the substation level and does not systematically consider the impact of the location and configuration of BESS on the voltage profiles, losses and utilisation within a given feeder. In this paper, four configurations of BESS are considered: single-phase, unlinked three-phase, linked three-phase without storage for phase-balancing only, and linked three-phase with storage. These four configurations are then assessed based on models of two real LV networks. In each case, the impact of the BESS is systematically evaluated at every node in the LV network using Matlab linked with OpenDSS. The location and configuration of a BESS is shown to be critical when seeking the best overall network impact or when considering specific impacts on voltage, losses, or utilisation separately. Furthermore, the paper also demonstrates that phase-balancing without energy storage can provide much of the gains on unbalanced networks compared to systems with energy storage.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the first part some information and characterisation about an AC distribution network that feeds traction substations and their possible influences on the DC traction load flow are presented. Those influences are investigated and mathematically modelled. To corroborate the mathematical model, an example is presented and their results are confronted with real measurements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We consider the two-level network design problem with intermediate facilities. This problem consists of designing a minimum cost network respecting some requirements, usually described in terms of the network topology or in terms of a desired flow of commodities between source and destination vertices. Each selected link must receive one of two types of edge facilities and the connection of different edge facilities requires a costly and capacitated vertex facility. We propose a hybrid decomposition approach which heuristically obtains tentative solutions for the vertex facilities number and location and use these solutions to limit the computational burden of a branch-and-cut algorithm. We test our method on instances of the power system secondary distribution network design problem. The results show that the method is efficient both in terms of solution quality and computational times. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Drinking water quality guidelines are becoming increasingly stringent. To comply with these guidelines and to manage water quality in a distribution system, improved understanding of the movement and fate of drinking water constituents within the system is required. This study illustrates the construction and calibration of an electronic model of the Townsville drinking water distribution system. Being in the tropics, the temperature of the water in the distribution system changes little throughout the year (usually between 20 and 25°C); also, water is supplied to the system from two sources, the location of the blending of these waters is varies with demand.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper examines and analyzes different aggregation algorithms to improve accuracy of forecasts obtained using neural network (NN) ensembles. These algorithms include equal-weights combination of Best NN models, combination of trimmed forecasts, and Bayesian Model Averaging (BMA). The predictive performance of these algorithms are evaluated using Australian electricity demand data. The output of the aggregation algorithms of NN ensembles are compared with a Naive approach. Mean absolute percentage error is applied as the performance index for assessing the quality of aggregated forecasts. Through comprehensive simulations, it is found that the aggregation algorithms can significantly improve the forecasting accuracies. The BMA algorithm also demonstrates the best performance amongst aggregation algorithms investigated in this study.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Isolated distribution systems are dispersed throughout regional Queensland to supply small isolated communities that are distant from the main supply grid. The costs of maintaining the electricity supply to these areas is costly; mainly due to the cost of diesel fuel. Furthermore, there is a community focus on climate change, and Ergon Energy aims to reduce the reliance on fossil fuels whilst optimising cost efficiencies and greenhouse gas emissions. The objective of this study is to examine the impacts of renewable energy sources in isolated power systems. For the locations studied, viable renewable energy sources have been integrated into these networks. Anticipated challenges and issues with the integration of the intermittent renewable energy sources were addressed, using mitigation techniques, including energy storage solutions. The investigation and findings demonstrated that network improvements can be achieved by an ideal level of renewable penetration, which has been the main focus of the project. The project involved the development and simulation of MATLAB Simulink and SINCAL models of the two isolated networks at Gununa and Bamaga. The subsequent analysis of these systems has shown a modest penetration level of renewables can be combined with energy storage solutions, which reduces fuel consumption and greenhouse gas emissions at these locations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Large-scale renewable energy (RE) integration into the distribution network (DN) causes uncertainties due to its intermittent nature and is a challenging task today. In general RE sources are mostly connected near the end user level, i.e., in the low voltage distribution network. RE integration introduces bi-directional power flows across distribution transformer (DT) and hence DN experiences with several potential problems that includes voltage fluctuations, reactive power compensation and poor power factor in the DN. This study identifies the potential effects causes due to large-scale integration of RE into the Berserker Street Feeder, Frenchville Substation under Rockhampton DN. From the model analyses, it has clearly evident that voltage of the Berserker Street Feeder fluctuates with the increased integration of RE and causes uncertainties in the feeder as well as the DN.