864 resultados para Drinking vessels.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study focuses prudent elucidation of microbial pollution and antibiotic sensitivity profiling of the fecal coliforms isolated from River Cauvery, a major drinking water source in Karnataka, India. Water samples were collected from ten hotspots during the year 2011-2012. The physiochemical characteristics and microbial count of water samples collected from most of the hotspots exhibited greater biological oxygen demand and bacterial count especially coliforms in comparison with control samples (p <= 0.01). The antibiotic sensitivity testing was performed using 48 antibiotics against the bacterial isolates by disk-diffusion assay. The current study showed that out of 848 bacterial isolates, 93.51 % (n=793) of the isolates were found to be multidrug-resistant to most of the current generation antibiotics. Among the major isolates, 96.46 % (n=273) of the isolates were found to be multidrug-resistant to 30 antibiotics and they were identified to be Escherichia coli by 16S rDNA gene sequencing. Similarly, 93.85 % (n=107), 94.49 % (n=103), and 90.22 % (n=157) of the isolates exhibited multiple drug resistance to 32, 40, and 37 antibiotics, and they were identified to be Enterobacter cloacae, Pseudomonas trivialis, and Shigella sonnei, respectively. The molecular studies suggested the prevalence of blaTEM genes in all the four isolates and dhfr gene in Escherichia coli and Sh. sonnei. Analogously, most of the other Gram-negative bacteria were found to be multidrug-resistant and the Gram-positive bacteria, Staphylococcus spp. isolated from the water samples were found to be methicillin and vancomycin-resistant Staphylococcus aureus. This is probably the first study elucidating the bacterial pollution and antibiotic sensitivity profiling of fecal coliforms isolated from River Cauvery, Karnataka, India.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Household-level water treatment and safe storage systems (HWTS) are simple, local, user-friendly, and low cost options to improve drinking water quality at the point of use. However, despite conclusive evidence of the health and economic benefits of HWTS, and promotion efforts in over 50 countries in the past 20 years, implementation outcomes have been slow, reaching only 5-10 million regular users. This study attempts to understand the barriers and drivers affecting HWTS implementation. Using a case study example of a biosand filter program in southern India, system dynamics modelling is shown to be a useful tool to map the inter-relationships of different critical factors and to understand the dissemination dynamics. It is found that the co-existence of expanding quickly and achieving financial sustainability appears to be difficult to achieve under the current program structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a newly developed method of manufacturing spherical pressure vessels based on the technology of non-die explosive forming. Compared with the traditional method, this technology does not need any dies and pressing equipment, so that the cost of the production process can be greatly reduced, especially for vessels of less than 100 m3 capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased boating activities and new waterfront developments have contributed an estimated 3,000 dismantled, abandoned, junked, wrecked, derelict vessels to Florida coastal waters. This report outlines a method of siting and prioritizing derelict vessel removal using the Florida Keys as a test area. The data base was information on 240 vessels, obtained from Florida Marine Patrol files. Vessel location was plotted on 1:250,000 regional and 1:5,000 and 1:12,000 site maps. Type of vessel, length, hull material, engine, fuel tanks, overall condition, afloat and submerged characteristics, and accessibility, were used to derive parametric site indices of removal priority and removal difficulty. Results indicate 59 top priority cases which should be the focus of immediate clean up efforts in the Florida Keys. Half of these cases are rated low to moderate in removal difficulty; the remainder are difficult to remove. Removal difficulty is a surrogate for removal cost: low difficulty -low cost, high difficulty - high cost. The rating scheme offers coastal planners options of focusing removal operations either on (1) specific areas with clusters of high priority derelict vessels or on (2) selected targeted derelicts at various, specific locations. (PDF has 59 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ENGLISH: Since the inception of the Inter-American Tropical Tuna Commission in 1950, one of the primary tasks of its scientific staff has been the collection and analysis of the statistics of total catch, effort expended in obtaining this catch, and the apparent abundance of yellowfin tuna (Neothunnus macropterus) and the skipjack tuna (Katsuwonus pelamis) in the Eastern Pacific Ocean. A concentrated effort by the staff during 1951 and 1952 resulted in the compilation of a series of historical data on the catch and catch-per-effort of tropical tunas for the years 1934-1950, and in the establishment of a detailed logbook system to monitor the current activities of the tuna fleets. Schaefer (1953) and Shimada and Schaefer (1956) have reviewed in detail the methods of collection and analysis of these data. Further studies, based on these and subsequently collected records, are contained in publications by Schaefer (1957), Shimada (1958), Alverson (1959, 1960), Griffiths (1960) and Calkins (1961). SPANISH: Desde que la Comisión Interamericana del Atún Tropical comenzó sus funciones en 1950, entre las más importantes tareas de su personal científico incluyó la recolección y análisis de las estadísticas de la captura total, del esfuerzo empleado en obtener esta captura y de la abundancia aparente de los atunes aleta amarilla (Neothunnus macropterus) y barriletes (Katsutvonus pelamis) en el Océano Pacífico Oriental. El concentrado esfuerzo del personal científico de la Comisión durante 1951 y 1952 dió como resultado la compilación de una serie de datos históricos sobre la captura de atunes tropicales y sobre la captura según el esfuerzo durante los años 1934 a 1950, así como el establecimiento de un sistema detallado de registro de las anotaciones en los cuadernos de bitácora para vigilar las actividades diarias de las flotas atuneras. Schaefer (1953) y Shimada y Schaefer (1956) han expuesto detalladamente los métodos de recolección y análisis de dichos datos. Otros estudios, basados en estos registros y en los recolectados posteriormente, se encuentran en las publicaciones de Schaefer (1957), Shimada (1958), Alverson (1959, 1960), Griffiths (1960) y Calkins (1961).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During 1973-88, 3,661 marine mammals of 17 species were reported as incidental catch by U.S. fishery observers aboard foreign and joint venture trawl vessels in the U.S. Exclusive Economic Zone in the North Pacific Ocean and the Bering Sea. Northern sea lions (Eumetopias jubatus) accounted for 90% of the reported incidental mortality in the Gulf of Alaska and eastern Bering Sea. Nearly half of these sea lions were taken in trawl nets in the Shelikof Strait, Alaska, joint venture fishery during 1982-84. However, high incidental mortality rates (>25 sea lions per 10,000 metric tons of groundfish catch) also occurred in the foreign fisheries near Kodiak Island and in the Aleutian Islands area in earlier years. Estimated annual mortality of incidentally caught northern sea lions in Alaska declined from 1,000 to 2,000 animals per year during the early 1970s and 1982 to fewer than 100 animals in 1988. In the Bering Sea most sea lions incidentally caught were males, while in the Gulf of Alaska females were more frequently caught. Females may also have been dominant in the incidental catch of sea lions in the Aleutian Islands area, but age and sex composition data are limited. Incidental mortality of adult female sea lions by foreign trawl fisheries in these areas could have partially contributed to the reported declines in northern sea lion populations in Alaska during the 1970s, but it cannot alone account for the present decline in population size. (PDF file contains 64 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of self-contained, low-maintenance sensor systems installed on commercial vessels is becoming an important monitoring and scientific tool in many regions around the world. These systems integrate data from meteorological and water quality sensors with GPS data into a data stream that is automatically transferred from ship to shore. To begin linking some of this developing expertise, the Alliance for Coastal Technologies (ACT) and the European Coastal and Ocean Observing Technology (ECOOT) organized a workshop on this topic in Southampton, United Kingdom, October 10-12, 2006. The participants included technology users, technology developers, and shipping representatives. They collaborated to identify sensors currently employed on integrated systems, users of this data, limitations associated with these systems, and ways to overcome these limitations. The group also identified additional technologies that could be employed on future systems and examined whether standard architectures and data protocols for integrated systems should be established. Participants at the workshop defined 17 different parameters currently being measured by integrated systems. They identified that diverse user groups utilize information from these systems from resource management agencies, such as the Environmental Protection Agency (EPA), to local tourism groups and educational organizations. Among the limitations identified were instrument compatibility and interoperability, data quality control and quality assurance, and sensor calibration andlor maintenance frequency. Standardization of these integrated systems was viewed to be both advantageous and disadvantageous; while participants believed that standardization could be beneficial on many levels, they also felt that users may be hesitant to purchase a suite of instruments from a single manufacturer; and that a "plug and play" system including sensors from multiple manufactures may be difficult to achieve. A priority recommendation and conclusion for the general integrated sensor system community was to provide vessel operators with real-time access to relevant data (e.g., ambient temperature and salinity to increase efficiency of water treatment systems and meteorological data for increased vessel safety and operating efficiency) for broader system value. Simplified data displays are also required for education and public outreach/awareness. Other key recommendations were to encourage the use of integrated sensor packages within observing systems such as 100s and EuroGOOS, identify additional customers of sensor system data, and publish results of previous work in peer-reviewed journals to increase agency and scientific awareness and confidence in the technology. Priority recommendations and conclusions for ACT entailed highlighting the value of integrated sensor systems for vessels of opportunity through articles in the popular press, and marine science. [PDF contains 28 pages]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ENGLISH: This report presents fine-scale spatial summaries of annual catch and effort information compiled by the IATTC staff. These data summaries are presented in a graphical format, and display only information collected from purse-seine vessels fishing in the eastern Pacific Ocean (EPO) during 1965-1998. Data collected from baitboat and longline vessels fishing in the EPO are not considered in this report. Equivalent data from Japanese longline vessels fishing in the EPO are presented by Uosaki and Bayliff(1999) for 1988-1992 and by' references cited in that publication for 1956-1987. SPANISH: Este informe presenta resúmenes espaciales a escala fina de información sobre captura y esfuerzo anuales compilada por el personal de la CIAT. Se presentan los resúmenes en formato gráfico, e incluyen solamente información tomada de barcos cerqueros pescando en el Océano Pacifico oriental (OPO) durante 1965-1998. No se consideran en el informe datos provenientes de barcos de camada y palangreros que pescan en el OPO. Se presentan datos equivalentes de barcos palangreros japoneses pescando en el OPO en Uosaki y Bayliff (1999) para 1988-1992 yen las referencias citadas en dicha publicación para 1956-1987. (PDF contains 104 pages.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the mesotrophic-eutrophic Saidenbach Reservoir in Saxony, the nanoplankton and cyanobacteria have increased at the expense of diatom dominance, due to a doubling of the external phosphorus load in the last 15 years. However, the phosphorus sedimentation flux is still very high (up to 80% of the input), corresponding to more than 2 g m2 d-1 in terms of dry weight. There is a strong correlation between the abundance of diatoms in the euphotic zone and their sedimentation flux (with a delay of about 2 weeks). Only about 25% of the deposited material could be clearly attributed to plankton biomass; the remainder resulted from flocculation and precipitation processes or directly from the inflow of clay minerals. The ash content of the deposited material was high (73%). Thus the sedimentation flux can be considered to operate as an internal water-treatment/oligotrophication process within the lake. The neighbouring Neunzehnhain Reservoir still has a very clear water with a transparency up to 18 m depth. Though the sediment was not much lower than Saidenbach sediment in total phosphorus and total numbers of bacteria, sulphide was always absent and the ratio of Fe 2+ to Fe 3+ was very low in the upper (0- 5 cm) layer. Thus the external and internal phosphorus loads do not attain the critical level necessary to induce a ”phosphorus - phytoplankton” feedback loop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tap water is not sterile; it contains organisms which grow in water distribution systems or inside taps and their fittings. The absence of known pathogenic bacteria is assured by the absence of the indicator organisms but concerns have been raised in the past few years that drinking water fulfilling the standards laid down in the EC Directive ECC 80/778 may still cause disease. These concerns have arisen from several sources: the fact that a cause has been identified in only half of all suspected waterborne outbreaks of disease; reports have suggested that heterotrophic bacteria possessing single pathogenic mechanisms such as haemolysin may cause disease; reports of heterotrophic organisms causing water contact diseases in hospitals. These concerns led to a reappraisal of the pathogenic potential of heteretrophic bacteria, by carrying out an extensive literature search and review commissioned by the UK Water Research Company. This research identified many papers showing an association between drinking water and heterotrophic bacteria but only very few reports of suspected waterborne disease associated with the heterotrophs. The organisms demonstrating potential to cause disease were species of Aeromonas and Yersinia, but typing of organisms identified in patients and isolated from the water revealed very few similarities. The potential of Aeromonas and Yersinia to cause waterborne disease is thought to be very low and the Communicable Disease Surveillance Centre database of laboratory infections due to these two genera of organisms was analysed to produce population-related incidences for each health region in England and Wales. Additionally a laboratory questionnaire revealed different levels of ascertainment of these two organisms in different laboratories of the Public Health Laboratory Service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no evidence to indicate that there is a risk of acquiring a virus infection through the consumption of properly treated drinking water, provided the integrity of the distribution system is maintained and there is no post-treatment contamination. The consumption of inadequately treated, untreated or post-treatment contaminated water is, however, associated with a risk of hepatitis A, hepatitis E and viral gastroenteritis. The use of the standard bacterial indicators for water monitoring provides an adequate safeguard against viral contamination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The direct measurement of in situ respiring bacteria using 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) shows that, especially for Gram-negative bacteria, large numbers of viable but non-culturable (VBNC) bacteria are present in finished water from a conventional water treatment plant, and the regrowth of bacteria along distribution networks can be seen rapidly by using this very sensitive technique. The level of bacterial inactivation with chlorine is much less important than has been previously supposed (based on experiments with non-injured laboratory strains of bacteria and classical culture techniques). Threshold values of VBNC bacteria leaving water treatment plants or regrowing along distribution systems have to be determined for better control of coliform regrowth and health- risks associated with the consumption of drinking water.