963 resultados para Distribution control center


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2008

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2009

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2010

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Few studies on sugar cane have evaluated the root system of the crop, in spite of its importance. This is mainly due to the difficulty of evaluation and high variability of results. The objective of this study was to develop an evaluation method of the cane root system by means of probes so as to evaluate the mass, distribution and metabolically active roots related to N fertilization at planting. For this purpose, an experiment was conducted in an Arenic Kandiustults with medium texture in Jaboticabal/SP, in a randomized block design with four replications and four treatments: control (without N) and 40, 80 and 120 kg ha-1 of N applied in the form of urea in the planting furrow of the cane variety SP81 3250. One week before harvest, a urea-15N solution was applied at the cane stalk base to detect active metabolism in the root system. Trenches of 1.5 m length and 0.6 m depth were opened between two sugar cane rows for root sampling by two methods: monoliths (0.3, 0.2 and 0.15 m wide, deep and long respectively) taken from the trench wall and by probe (internal diameter 0.055 m). For each method, 15 samples per plot were collected. The roots were separated from the soil in a sieve (2 mm mesh), oven-dried (at 65 ºC) and the dry matter was measured. Root sampling by probes resulted in root mass that did not differ from the evaluation in monoliths, indicating that this evaluation method may be used for sugar cane root mass, although neither the root distribution in the soil profile nor the rhizome mass were efficiently evaluated, due to the small sample volume. Nitrogen fertilization at planting did not result in a greater root accumulation in the sugar cane plant, but caused changes in the distribution of the root system in the soil. The absence of N fertilization led to a better root distribution in the soil profile, with 50, 34 and 16 % in the 0-0.2, 0.2-0.4 and 0.4-0.6 m layers, respectively; in the fertilized treatments the roots were concentrated in the surface layer, with on average 70, 17 and 13 % for the same layers. The metabolically active roots were concentrated in the center of the cane stool, amounting to 40 % of the total root mass, regardless of N fertilization (application of 120 kg ha-1 N or without N).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2011

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2012

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2013

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2014

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Report on the Iowa Department of Human Services – Central Distribution Center for the year ended June 30, 2015

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Electricity distribution network operation (NO) models are challenged as they are expected to continue to undergo changes during the coming decades in the fairly developed and regulated Nordic electricity market. Network asset managers are to adapt to competitive technoeconomical business models regarding the operation of increasingly intelligent distribution networks. Factors driving the changes for new business models within network operation include: increased investments in distributed automation (DA), regulative frameworks for annual profit limits and quality through outage cost, increasing end-customer demands, climatic changes and increasing use of data system tools, such as Distribution Management System (DMS). The doctoral thesis addresses the questions a) whether there exist conditions and qualifications for competitive markets within electricity distribution network operation and b) if so, identification of limitations and required business mechanisms. This doctoral thesis aims to provide an analytical business framework, primarily for electric utilities, for evaluation and development purposes of dedicated network operation models to meet future market dynamics within network operation. In the thesis, the generic build-up of a business model has been addressed through the use of the strategicbusiness hierarchy levels of mission, vision and strategy for definition of the strategic direction of the business followed by the planning, management and process execution levels of enterprisestrategy execution. Research questions within electricity distribution network operation are addressed at the specified hierarchy levels. The results of the research represent interdisciplinary findings in the areas of electrical engineering and production economics. The main scientific contributions include further development of the extended transaction cost economics (TCE) for government decisions within electricity networks and validation of the usability of the methodology for the electricity distribution industry. Moreover, DMS benefit evaluations in the thesis based on the outage cost calculations propose theoretical maximum benefits of DMS applications equalling roughly 25% of the annual outage costs and 10% of the respective operative costs in the case electric utility. Hence, the annual measurable theoretical benefits from the use of DMS applications are considerable. The theoretical results in the thesis are generally validated by surveys and questionnaires.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACTScarlet Morning Glory is considered to be an infesting weed that affects several crops and causes serious damage. The application of chemical herbicides, which is the primary control method, requires a broad knowledge of the various characteristics of the solution and application technology for a more efficient phytosanitary treatment. Therefore this study aimed to characterize the effect of rainfall incidence on the control of Ipomoea hederifolia, considering droplet size, surface tension, contact angle of droplets formed by herbicides liquid on vegetal and artificial surfaces, associated to adjuvants and the volumetric distribution profile of the spray jet. The addition of the adjuvants to the herbicide spraying liquid improved the application quality, as it influenced the angle formed by the spray by broadening the deposition band of the spray nozzle and thus the possible distance between the nozzles on spray boom and due the changes at droplet size, which contribute to a safety application. The rainfall occurrence affected negatively the weed control with the different spraying liquids and also the dry matter weight, suggesting that the phytosanitary product applied was washed off.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, a controller for regulating the transients in water distribution networks is established. The control technique is the H¥ Control. The developed controller is applied to a water distribution network and the results of this application demonstrate that the technique allowed the establishment of a robust controller, capable of attenuating the disturbances in a suitable way, being effective in controlling the oscillations of the state variables in question.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article models the interactions between safety and quality control and stage of distribution in the food marketing complex