1000 resultados para Digital Labor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to determine if digital vasculitis (DV), a clinical manifestation with a high systemic lupus erythematosus disease activity index (SLEDAI) score, is associated with lupus severity. DV and other clinical manifestations defined according to the SLEDAI were evaluated in 168 consecutive patients with systemic lupus erythematosus (SLE). Two groups were defined according to presence (DV+, n = 27) or absence of DV (DV-, n = 141) at the time of evaluation. The exclusion criterion was the presence of antiphospholipid syndrome (Sapporo`s criteria). The two groups were comparable with regard to age (P = 0.09), gender (P = 1.00), white race (P = 0.81), and disease duration (P = 0.78). Compared to the DV-group, the DV+ group had a significantly higher frequency of mucocutaneous manifestations (66.7 vs. 39.0%, P = 0.01), haematological abnormalities (22.2 vs. 6.4%, P = 0.02) and constitutional symptoms (11.1 vs. 0.7%, P = 0.01). Renal and neurological involvements were similar in both groups ( P = 0.57 and P = 1.00, respectively). The evaluation of each SLEDAI parameter confirmed that the DV+ group had higher frequencies of mild manifestations, such as new rash (P = 0.02), alopecia (P = 0.02), oral ulcers (P = 0.045), fever (P = 0.01) and leucopenia (P = 0.005). In contrast, both groups had similarly increased anti-dsDNA (P = 0.78) and decreased complement levels (P = 0.29). In conclusion, DV in patients with SLE identifies a subgroup of a mild disease. The high `weighted` index attributed to this alteration in the SLEDAI score should therefore be revised. Lupus (2009) 18, 990-993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of sensorineural hearing loss is based on hearing aids, also known as individual sound amplification devices. The hearing aids purchased by the Brazilian Government, aiming at fulfilling public policies, are based on dedicated components, which bring about benefits, but also render them expensive and may impair repair services after manufacture`s warranty expires. Aim: to design digital behind-the-ear hearing aids built from standardized components coming from the very supply chain of these manufacturers. Study design: experimental. Materials and Methods: to identify the supply chain of these manufacturers, request samples and set up hearing aids in the laboratory. Results: The developed hearing aids did not show lesser electroacoustic characteristics when compared to those acquired by the Government, also being tested by the same reference international technical standard. Conclusion: It is possible to develop digital behind-the-ear hearing aids based on off-the-shelf components from hearing aid manufacturers` supply chain. Their advantages include low operational costs - for acquisition (with clear advantages for the Government) and service (advantage for the patient).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Olm MA, Kogler JE Jr, Macchione M, Shoemark A, Saldiva PH, Rodrigues JC. Primary ciliary dyskinesia: evaluation using cilia beat frequency assessment via spectral analysis of digital microscopy images. J Appl Physiol 111: 295-302, 2011. First published May 5, 2011; doi:10.1152/japplphysiol.00629.2010.-Ciliary beat frequency (CBF) measurements provide valuable information for diagnosing of primary ciliary dyskinesia (PCD). We developed a system for measuring CBF, used it in association with electron microscopy to diagnose PCD, and then analyzed characteristics of PCD patients. 1 The CBF measurement system was based on power spectra measured through digital imaging. Twenty-four patients suspected of having PCD (age 1-19 yr) were selected from a group of 75 children and adolescents with pneumopathies of unknown causes. Ten healthy, nonsmoking volunteers (age >= 17 yr) served as a control group. Nasal brush samples were collected, and CBF and electron microscopy were performed. PCD was diagnosed in 12 patients: 5 had radial spoke defects, 3 showed absent central microtubule pairs with transposition, 2 had outer dynein arm defects, 1 had a shortened outer dynein arm, and 1 had a normal ultrastructure. Previous studies have reported that the most common cilia defects are in the dynein arm. As expected, the mean CBF was higher in the control group (P < 0.001) and patients with normal ultrastructure (P < 0.002), than in those diagnosed with cilia ultrastructural defects (i.e., PCD patients). An obstructive ventilatory pattern was observed in 70% of the PCD patients who underwent pulmonary function tests. All PCD patients presented bronchial wall thickening on chest computed tomography scans. The protocol and diagnostic techniques employed allowed us to diagnose PCD in 16% of patients in this study.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the effects of combined spinal-epidural and traditional epidural analgesia on uterine basal tone and its association with the occurrence of fetal heart rate (FHR) abnormalities. METHODS: Seventy-seven laboring patients who requested pain relief during labor were randomly assigned to combined spinal-epidural (n=41) or epidural analgesia (n=36). Uterine contractions and FHR were recorded 15 minutes before and after analgesia. Uterine tone was evaluated with intrauterine pressure catheter. Primary outcomes were the elevation of baseline uterine tone and occurrence of FHR prolonged decelerations or bradycardia after analgesia. The influence of other variables such as oxytocin use, hypotension, and speed of pain relief were estimated using a logistic regression model. RESULTS: The incidence of all outcomes was significantly greater in the combined spinal-epidural group compared with epidural: uterine hypertonus (17 compared with 6; P=.018), FHR abnormalities (13 compared with 2; P<.01), and both events simultaneously (11 compared with 1; P<.01). Logistic regression analysis showed the type of analgesia as the only independent predictor of uterine hypertonus (odds ratio 3.526, 95% confidence interval 1.21-10.36; P=.022). For the occurrence of FHR abnormalities, elevation of uterine tone was the independent predictor (odds ratio 18.624, 95% confidence interval 4.46-77.72; P<.001). Regression analysis also found a correlation between decrease on pain scores immediately after analgesia and the estimated probability of occurrence of hypertonus and FHR abnormalities. CONCLUSION: Combined spinal-epidural analgesia is associated with a significantly greater incidence of FHR abnormalities related to uterine hypertonus compared with epidural analgesia. The faster the pain relief after analgesia, the higher the probability of uterine hypertonus and FHR changes. CLINICAL TRIAL REGISTRATION: Umin Clinical Trials Registry, http://www.umin.ac.jp/ctr/index.htm, UMIN000001186

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To compare pelvic floor muscle (PFM) strength between women undergoing vaginal delivery, cesarean section, and nulliparae, investigating the factors associated with PFM strength, and observing the correlation between vaginal digital palpation and use of a perineometer. Methods. A cross-sectional study was conducted, including 31 women following vaginal delivery, 30 women following cesarean section, and 30 nulliparous women. PFM strength was measured by vaginal digital palpation and use of a perineometer. Multiple linear regression analysis with adjustment for covariables was used to compare the mean PFM strength and identify its associated factors. Results. The mean PFM strength of women undergoing vaginal delivery and cesarean section was 25.6 +/- 14.5 cmH(2)O and 39.6 +/- 22.0 cmH(2)O (p < 0.01, adjusted for covariables), respectively. A correlation was observed between measurements of PFM strength obtained by vaginal digital palpation and use of a perineometer (tau = 0.82; p < 0.01). The non-white race/ethnicity was negatively associated with PFM strength (coefficient: -10.2424; p = 0.02). Conclusions. A lower PFM strength was observed in women with a history of vaginal delivery compared to those undergoing cesarean section. Non-white race/ethnicity negatively affected PFM strength. Our data suggest that vaginal digital palpation may be used in clinical practice because of its expressive correlation with use of a perineometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)