941 resultados para Differences-in-Differences method
Resumo:
OBJECTIVE: Patients with schizophrenia show deficits in visuospatial working memory and visual pursuit processes. It is currently unclear, however, whether both impairments are related to a common neuropathological origin. The purpose of the present study was therefore to examine the possible relations between the encoding and the discrimination of dynamic visuospatial stimuli in schizophrenia. METHOD: Sixteen outpatients with schizophrenia and 16 control subjects were asked to encode complex disc displacements presented on a screen. After a delay, participants had to identify the previously presented disc trajectory from a choice of six static linear paths, among which were five incorrect paths. The precision of visual pursuit eye movements during the initial presentation of the dynamic stimulus was assessed. The fixations and scanning time in definite regions of the six paths presented during the discrimination phase were investigated. RESULTS: In comparison with controls, patients showed poorer task performance, reduced pursuit accuracy during incorrect trials and less time scanning the correct stimulus or the incorrect paths approximating its global structure. Patients also spent less time scanning the leftmost portion of the correct path even when making a correct choice. The accuracy of visual pursuit and head movements, however, was not correlated with task performance. CONCLUSIONS: The present study provides direct support for the hypothesis that active integration of visuospatial information within working memory is deficient in schizophrenia. In contrast, a general impairment of oculomotor mechanisms involved in smooth pursuit did not appear to be directly related to lower visuospatial working memory performance in schizophrenia.
Resumo:
Introduction: The prevalence of multimorbidity (MM) in hospitalized patients is increasing and recognized as an important factor that may modify the strategies of treatment and increase the length of stay. Little is currently known about the prevalence of MM in the general population and if measured or self-reported diseases are different in the outpatient setting compared to hospitalized patients. The objective of the study was, therefore, to assess the prevalence of self-reported and measured MM in representative sample of the general population aged 35-75 years in Switzerland. Method: Data were obtained from the population based CoLaus Study: 3712 participants (1965 women, 50±9 years). MM was defined as presenting >=2 morbidities according to a list of 27 items (either measured or self-reported data, according to Barret et al.) or a Functional Comorbidity Index (FCI) (18 items, measured only). Results: The prevalence of MM according to these three definitions is summarized in the table 1. For all definitions prevalence of MM was higher in women, elderly participants, those with lower education levels, Swiss nationals, former smokers and obese participants. The prevalence of MM when measured data were used was significantly higher than according to self-reported (p<0.001). Multivariate analysis confirmed most of these associations, except that no difference was found for educational level and for overweight participants. Conclusion: The prevalence of MM is high in the general population, ranging from 13.8 and 50.3% even in the younger age group. The prevalence is higher in women, and increases with age and weight. The prevalence varies considerably according to the definition and is lower when using self-reported compared to measured data.
Resumo:
OBJECTIVE: To investigate the determinants and the 4-year evolution of the forgoing of healthcare for economic reasons in Switzerland. METHOD: Population-based survey (2007-2010) of a representative sample aged 35-74years in the Canton of Geneva, Switzerland. Healthcare forgone, socioeconomic and insurance status, marital status, and presence of dependent children were assessed using standardized methods. RESULTS: A total of 2601 subjects were included in the analyses. Of the subjects, 13.8% (358/2601) reported having forgone healthcare for economic reasons, with the percentage varying from 3.7% in the group with a monthly income ≥13,000CHF (1CHF≈1$) to 30.9% in the group with a monthly income <3000CHF. In subjects with a monthly income <3000CHF, the percentage who had forgone healthcare increased from 22.5% in 2007/8 to 34.7% in 2010 (P trend=0.2). Forgoing healthcare for economic reasons was associated with lower income, female gender, smoking status, lower job position, having dependent children, being divorced and single, paying a higher deductible, and receiving a premium subsidy. CONCLUSION: In a Swiss region with universal health insurance coverage, the reported prevalence of forgoing healthcare for economic reasons was high and greatly dependent on socioeconomic factors. Our data suggested an increasing trend among participants with the lowest income.
Resumo:
Software engineering is criticized as not being engineering or 'well-developed' science at all. Software engineers seem not to know exactly how long their projects will last, what they will cost, and will the software work properly after release. Measurements have to be taken in software projects to improve this situation. It is of limited use to only collect metrics afterwards. The values of the relevant metrics have to be predicted, too. The predictions (i.e. estimates) form the basis for proper project management. One of the most painful problems in software projects is effort estimation. It has a clear and central effect on other project attributes like cost and schedule, and to product attributes like size and quality. Effort estimation can be used for several purposes. In this thesis only the effort estimation in software projects for project management purposes is discussed. There is a short introduction to the measurement issues, and some metrics relevantin estimation context are presented. Effort estimation methods are covered quite broadly. The main new contribution in this thesis is the new estimation model that has been created. It takes use of the basic concepts of Function Point Analysis, but avoids the problems and pitfalls found in the method. It is relativelyeasy to use and learn. Effort estimation accuracy has significantly improved after taking this model into use. A major innovation related to the new estimationmodel is the identified need for hierarchical software size measurement. The author of this thesis has developed a three level solution for the estimation model. All currently used size metrics are static in nature, but this new proposed metric is dynamic. It takes use of the increased understanding of the nature of the work as specification and design work proceeds. It thus 'grows up' along with software projects. The effort estimation model development is not possible without gathering and analyzing history data. However, there are many problems with data in software engineering. A major roadblock is the amount and quality of data available. This thesis shows some useful techniques that have been successful in gathering and analyzing the data needed. An estimation process is needed to ensure that methods are used in a proper way, estimates are stored, reported and analyzed properly, and they are used for project management activities. A higher mechanism called measurement framework is also introduced shortly. The purpose of the framework is to define and maintain a measurement or estimationprocess. Without a proper framework, the estimation capability of an organization declines. It requires effort even to maintain an achieved level of estimationaccuracy. Estimation results in several successive releases are analyzed. It isclearly seen that the new estimation model works and the estimation improvementactions have been successful. The calibration of the hierarchical model is a critical activity. An example is shown to shed more light on the calibration and the model itself. There are also remarks about the sensitivity of the model. Finally, an example of usage is shown.
Resumo:
Background: Alcohol-related expectancies are especially relevant in relation to alcohol consumption during adolescence. The main aim of this study was to adapt and translate into Spanish (Castilian) the Expectancy Questionnaire (EQ), and to study its psychometric properties in adolescents. Method: The sample was composed of 514 adolescents (57.20% female, mean age = 15.21; SD = .63) who completed the EQ and the alcohol consumption questionnaire AIS-UJI. Results: Confi rmatory factor analysis indicated that an eight-factor model, grouped into two general factors of positive and negative expectancies, had acceptable fi t indices. Cronbach’s alphas ranged from .75 to .96. Finally, the structural equation model showed that positive expectancies were positively related to alcohol use, whereas negative expectancies were negatively related to drinking. Conclusions: Results showed that the Spanish version of the EQ for adolescents is a valid and reliable questionnaire to measure expectancies about alcohol effects.
Resumo:
This dissertation is based on four articles dealing with modeling of ozonation. The literature part of this considers some models for hydrodynamics in bubble column simulation. A literature review of methods for obtaining mass transfer coefficients is presented. The methods presented to obtain mass transfer are general models and can be applied to any gas-liquid system. Ozonation reaction models and methods for obtaining stoichiometric coefficients and reaction rate coefficients for ozonation reactions are discussed in the final section of the literature part. In the first article, ozone gas-liquid mass transfer into water in a bubble column was investigated for different pH values. A more general method for estimation of mass transfer and Henry’s coefficient was developed from the Beltrán method. The ozone volumetric mass transfer coefficient and the Henry’s coefficient were determined simultaneously by parameter estimation using a nonlinear optimization method. A minor dependence of the Henry’s law constant on pH was detected at the pH range 4 - 9. In the second article, a new method using the axial dispersion model for estimation of ozone self-decomposition kinetics in a semi-batch bubble column reactor was developed. The reaction rate coefficients for literature equations of ozone decomposition and the gas phase dispersion coefficient were estimated and compared with the literature data. The reaction order in the pH range 7-10 with respect to ozone 1.12 and 0.51 the hydroxyl ion were obtained, which is in good agreement with literature. The model parameters were determined by parameter estimation using a nonlinear optimization method. Sensitivity analysis was conducted using object function method to obtain information about the reliability and identifiability of the estimated parameters. In the third article, the reaction rate coefficients and the stoichiometric coefficients in the reaction of ozone with the model component p-nitrophenol were estimated at low pH of water using nonlinear optimization. A novel method for estimation of multireaction model parameters in ozonation was developed. In this method the concentration of unknown intermediate compounds is presented as a residual COD (chemical oxygen demand) calculated from the measured COD and the theoretical COD for the known species. The decomposition rate of p-nitrophenol on the pathway producing hydroquinone was found to be about two times faster than the p-nitrophenol decomposition rate on the pathway producing 4- nitrocatechol. In the fourth article, the reaction kinetics of p-nitrophenol ozonation was studied in a bubble column at pH 2. Using the new reaction kinetic model presented in the previous article, the reaction kinetic parameters, rate coefficients, and stoichiometric coefficients as well as the mass transfer coefficient were estimated with nonlinear estimation. The decomposition rate of pnitrophenol was found to be equal both on the pathway producing hydroquinone and on the path way producing 4-nitrocathecol. Comparison of the rate coefficients with the case at initial pH 5 indicates that the p-nitrophenol degradation producing 4- nitrocathecol is more selective towards molecular ozone than the reaction producing hydroquinone. The identifiability and reliability of the estimated parameters were analyzed with the Marcov chain Monte Carlo (MCMC) method. @All rights reserved. No part of the publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior permission of the author.
Resumo:
In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.
Resumo:
In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.
Resumo:
Two sensitive spectrophotometric methods are described for the determination of lansoprazole (LPZ) in bulk drug and in capsule formulation. The methods are based on the oxidation of lansoprazole by insitu generated bromine followed by determination of unreacted bromine by two different reaction schemes. In one procedure (method A), the residual bromine is treated with excess of iron (II), and the resulting iron (III) is complexed with thiocyanate and measured at 470 nm. The second approach (method B) involves treating the unreacted bromine with a measured excess of iron (II) and remaining iron (II) is complexed with orthophenanthroline at a raised pH, and measured at 510 nm. In both methods, the amount of bromine reacted corresponds to the amount of LPZ. The experimental conditions were optimized. In method A, the absorbance is found to decrease linearly with the concentration of LPZ (r = -0.9986) where as in the method B a linear increase in absorbance occurs (r = 0.9986) The systems obey Beer's law for 0.5-4.0 and 0.5-6.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 3.97µ10(4) and 3.07µ10(4) L mol-1cm-1 for method A and method B, respectively, and the corresponding Sandell sensitivity values are 0.0039 and 0.0013 µg cm-2. The limit of detection (LOD) and quantification (LOQ) are also reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of LPZ in capsules and the results tallied well with the label claim and the results were statistically compared with those of a reference method by applying the Student's t-test and F-test. No interference was observed from the concomitant substances normally added to capsules. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard-addition method.
Resumo:
Four simple titrimetric procedures are described for the determination of lisinopril (LNP) in bulk and in pharmaceuticals based on the neutralization of basic-amino and acidic carboxylic acid groups present in LNP. Method A is based on the neutralization of basic amino groups using perchloric acid as titrant in anhydrous acetic acid medium. Method B, method C and method D are based on neutralization of carboxylic acid group using NaOH, sodium methoxide and methanolic KOH, as titrants, respectively. Method A is applicable over 2.0-20.0 mg range and the calculations are based in the molar ratio of 1:2 (LNP:HClO4). Method B, method C and method D are applicable over 2.0-20.0 mg, 1.0-10.0 mg and 5.0-15.0 mg range, respectively, and their respective molar ratios are 1:1 (LNP:NaOH), 1:2 (LNP:CH3ONa) and 1:1 (LNP:KOH). Intraday and inter day accuracy and precision of the methods were evaluated and the results showed intra- and inter-day precision less than 2.7% (RSD), and accuracy of < 2.5 % (RE). The developed methods were applied to determine LNP in tablets and the results were validated statistically by comparing the results with those of the reference method by applying the Student's t-test and F-test. The accuracy was further ascertained by recovery studies via standard addition technique. No interferences from common tablet exipients was observed.
Resumo:
Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level.
Resumo:
A method for determining aflatoxins B1 (AFB1), B2 (AFB2),G1 (AFG1) andG2 (AFG2) in maize with florisil clean up was optimised aiming at one-dimensional thin layer chromatography (TLC) analysis with visual and densitometric quantification. Aflatoxins were extracted with chloroform: water (30:1, v/v), purified through florisil cartridges, separated on TLC plate, detected and quantified by visual and densitometric analysis. The in-house method performance characteristics were determined by using spiked, naturally contaminated maize samples, and certified reference material. The mean recoveries for aflatoxins were 94.2, 81.9, 93.5 and 97.3% in the range of 1.0 to 242 µg/kg for AFB1, 0.3 to 85mg/kg for AFB2, 0.6 to 148mg/kg for AFG1 and 0.6 to 140mg/kg for AFG2, respectively. The correlation values between visual and densitometric analysis for spiked samples were higher than 0.99 for AFB1, AFB2, AFG1 and 0.98 for AFG2. The mean relative standard deviations (RSD) for spiked samples were 16.2, 20.6, 12.8 and 16.9% for AFB1, AFB2, AFG1 and AFG2, respectively. The RSD of the method for naturally contaminated sample (n = 5) was 16.8% for AFB1 and 27.2% for AFB2. The limits of detection of the method (LD) were 0.2, 0.1, 0.1 and 0.1mg/kg and the limits of quantification (LQ) were 1.0, 0.3, 0.6 and 0.6mg/kg for AFB1, AFB2, AFG1 and AFG2, respectively.
Resumo:
A flow injection hydride generation direct current plasma atomic emission spectrometric (FI-HG-DCP-AES) method was developed for the determination of lead at ng.ml-l level. Potassium ferricyanide (K3Fe(CN)6) was used along with sodium tetrahydroborate(III) (NaBH4) to produce plumbane (PbH4) in an acid medium. The design of a gas-liquid separator (hydride generator) was tested and the parameters of the flow injection system were optimized to achieve a good detection limit and sample throughput. The technique developed gave a detection limit of 0.7 ng.ml-l(3ob). The precision at 20 ng.ml"* level was 1.6 % RSD with 1 1 measurements (n=l 1). Volume of sample loop was 500 |J.l. A sample throughput of 120 h"^ was achieved. The transition elements, Fe(II), FeOH), Cd(n), Co(II), Mn(n), Ni(II) and Zn(n) do not interfere in this method but 1 mg,l'l Cu(II) will suppress 50 % of the signal from a sample containing 20 ng.ml'l Pb. This method was successfully applied to determine lead in a calcium carbonate (CaC03) matrix of banded coral skeletons from Si-Chang Island in Thailand.
Resumo:
Introduction : La chronicité de la rhinosinusite, sa résistance aux antibiotiques, et ses exacerbations aiguës laissent croire que les biofilms sont impliqués dans la rhinosinusite chronique. Objectifs : Nous avons évalué la capacité des bactéries Pseudomonas aeruginosa, staphylocoques à coagulase négative et Staphylococcus aureus à former des biofilms par un essai in vitro, et si cette capacité de formation a un lien avec l’évolution de la maladie. Nous avons évalué in vitro l’effet de la moxifloxacine, un antibiotique utilisé dans le traitement de la rhinosinusite chronique sur des biofilms matures de Staphylococcus aureus. Méthodes : Trent et une souches bactériennes ont été isolées de 19 patients atteints de rhinosinusite chronique et qui ont subit au moins une chirurgie endoscopique des sinus. L’évolution de la maladie a été notée comme "bonne" ou "mauvaise" selon l’évaluation du clinicien. La production de biofilm a été évaluée grâce à la coloration au crystal violet. Nous avons évalué la viabilité du biofilm après traitement avec la moxifloxacine. Ces résultats ont été confirmés en microscopie confocale à balayage laser et par la coloration au LIVE/DEAD BacLight. Résultat et Conclusion : Vingt deux des 31 souches ont produit un biofilm. La production d’un biofilm plus importante chez Pseudomonas aeruginosa et Staphylococcus aureus était associée à une mauvaise évolution. Ceci suggère un rôle du biofilm dans la pathogenèse de la rhinosinusite chronique. Le traitement avec la moxifloxacine, à une concentration de 1000X la concentration minimale inhibitrice réduit le nombre des bactéries viables de 2 à 2.5 log. Ces concentrations (100 µg/ml - 200 µg/ml) sont faciles à atteindre dans des solutions topiques. Les résultats de notre étude suggèrent que l’utilisation de concentrations supérieure à la concentration minimale inhibitrice sous forme topique peut ouvrir des voies de recherche sur de nouveaux traitements qui peuvent être bénéfiques pour les patients atteints de forme sévère de rhinosinusite chronique surtout après une chirurgie endoscopique des sinus.
Resumo:
L’étude utilise la méthode des différences entre jumeaux monozygotes pour analyser le lien entre les pratiques parentales positives ou hostiles-réactives de la mère à 29 mois et la qualité des relations d’amitié des enfants à 6 ans, tout en contrôlant une série de facteurs confondants tels le sexe, le revenu familial, le tempérament et le poids à la naissance. Un effet modérateur du sexe est aussi testé. La méthodologie nouvelle et particulière de cette recherche permet de contrôler de possibles corrélations gènes-environnement. Les résultats ne concordent pas tous avec les hypothèses et démontrent que 1) le jumeau ayant reçu le plus de pratiques parentales positives de la mère est celui dont l’ami évalue le plus négativement sa relation d’amitié à 6 ans et 2) le jumeau ayant reçu le plus de pratiques parentales hostiles-réactives de la mère est celui dont l’ami évalue le moins positivement sa relation d’amitié à la maternelle. Différentes pistes d’explications sont proposées pour comprendre les résultats et pour guider les études futures.