926 resultados para Diagnóstico por imagem - Qualidade - Estudos experimentais
Resumo:
There are many advantages when using a phantom for the evaluation of the mammographic images, one of them is to test the visibility of the distribution of objects that constitute it, and then, set the best image in order to obtain a diagnostic medical insurance, trying to reach the best risk - benefit ratio for the patient. Typically, the quality of the mammographic image is performed by subjective and quantitative assessments. This study developed algorithms that can quantitatively evaluate digital images (DICOM), obtained from mammographic phantom consisting of test objects. The results were adjusted by the response of the subjective evaluation performed by experts in radiology. This procedure aims to create an independence of the experts in radiology in daily tests of quality control in routine clinical diagnostic radiology
Resumo:
Almost forty years computed tomography (CT) has been one of the most powerful tools in diagnostic imaging. However, this modality delivers relatively high doses to their patients. It is known that the inappropriate use and unnecessary radiation may be associated with a significant risk of cancer, especially in pediatric patients. Moreover, the quality assurance in CT, provided and required by Portaria 453/98 and the guide of the RE 1016/05, ensures that the images generated by computer tomography provide reliable diagnostic information with doses as low as reasonably achievable. This research aimed to make the quality control (QC) of CT equipment; establish a better relationship between dose and noise on the image to protocols of skull CT according to the study of optimization proposed in 2005 by Daros; and assess the dose distribution in different cranial organs for protocols of adult and pediatric use in the routine of the Department of Diagnostic Imaging of HCFMB-UNESP. The equipment used for testing QC, optimization and dosimetry was a third generation tomograph GE Sytec 3000i
Resumo:
Portosystemic shunt, an hepatobiliary anomaly, much common in dogs and less frequent in cats, can be detected by several diagnostic methods. Among them, the one which stands out is ultrasonography due to its numerous advantages: noninvasive, quick, accessible, relatively low cost and provides useful information relating to the other systems, apart from being a highly sensitive method. Portosystemic shunt diagnosis using ultrasonography becomes highly sensitive when associated with B-mode, color Doppler and pulsed Doppler. A bibliographic survey about portosystemic shunt ultrasonographic diagnosis was carried out, and the main ultrasonographic signals were: decreased hepatic size, difficulty in blood vessels visualization, presence of an anomalous vessel, tortuous with turbulent flow and, finally, increased portal blood flow velocity near the shunting vessel
Resumo:
The Quality Control services for diagnostic imaging is essential to ensure that their activities occur as planned. Procedures are aimed at a positive cost-benefit to the institution and risk-benefit to the patients. And this requires trained and skilled professionals working with high technology equipment. The company PhyMED Consultores em Física Médica e Radioproteção Ltda., a Pioneer in the field of Medica Physics in Rio Grande do Sul, is dedicated to providing consulting services in healthcare. Physicists are experienced working in many areas of diagnostic imaging
Resumo:
O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)
Resumo:
The equine locomotors system alterations are very frequent and corresponds a large portion of cases in equine medicine. The most equine veterinarian’s challenge is to do a precise diagnosis of lameness cause to perform a specific and proper treatment as early as possible. The navicular syndrome is considered responsible for one third of lameness causes and, although much studied, its etiology is still not fully understood. The most varied methods of diagnosis, such as x-ray, magnetic resonance, bursography, scintigraphy, computed tomography and ultrasound, have been used to assess podotrochlear apparatus situation in order to diagnose this syndrome. Among them transcuneal ultrasound can be used to observe some important structures such as the flexor surface of distal sesamoid bone, distal deep digital flexor tendon, distal sesamoid ligament entheses odd and the distal phalanx. The aim of this present paper is provide a brief review on the use and the technique of ultrasonography on third phalanx transcuneal region evaluation and its interpretation on navicular syndrome diagnosis in horses
Resumo:
By the early 20th century, the blood vessels could only be seen by anatomical studies. Shortly after the discovery of X-rays by Conrad Roentgen in 1895, the first experiments with radiographic imaging were performed with blood vessels. In 1905, the first experiment involving catheterization of arterial and venous system in dogs was performed and only in 1914 performed on living human patients. Parallel to these landmarks, there were advances in diagnostic imaging devices and the evolution of contrast substances was of utmost importance to the current angiography occupy a prominent role not only in terms of diagnosis, but also in the treatment of various disorders. The main objective of this review is to weave historical considerations and comparisons between the different methodologies used in angiography, because its importance; that may be in future, a veterinary diagnostic decisive test
Resumo:
Objectives: The objective of this study was to evaluate the ability of endodontists and general practioners to perform the differential radiographic diagnosis between internal and external root resorptions, using digitized periapical radiographs. Methods: Thirty periapical radiographic images of external and internal resorption were selected. The evaluators were comprised of 15 endodontists and 29 general practitioners who answered a questionnaire with the following question: “What type of resorption in the following radiographics do you diagnose?” (1) Inflammatory external root resorption. (2) Internal root resorption. Statistical analysis was performed based on the Mann-Whitney test, with significance level of 5%. Results: There was no statistically significant difference in the percentage of correct answers from specialists in endodontics and general practitioners. Conclusions: Both groups demonstrated satisfactory skill in the radiographic interpretation of internal and external resorption and there was a higher percentage of correct diagnosis of internal resorption than the external.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background: To establish the best methodology for diagnosis and management of patients with solid and complex renal masses by comparing the costs and benefits of different imaging methods and to improve differential diagnosis of these benign and malignant lesions, particularly by investigating tumour calcifications. Methods: We performed a prospective study on 31 patients with solid or complex masses by submitting them to Abdominal Ultrasonography (US), Doppler Ultrasonography of the renal mass (US Dop), Computed Tomography (CT), and Magnetic Resonance Imaging (MRI). Results: We found 28 patients with malignant and three with benign masses. Of the 28 malignant, 17 showed calcifications at CT; 16 central and one was of the pure peripheral curvilinear type (egg shell). Excretory Urography (IVP) had a significantly lower detection rate for central calcifications than both US and CT. Benign and malignant masses appeared as described in literature, with US, CT and MRI showing high sensitivity and specificity in renal tumor diagnosis. The exception was US Dop where we obtained lower sensitivity for the characterization of malignant tumor flow. Conclusions: In this series we were surprised to find that CT revealed central calcifications in 51.6% of patients, all with malignant lesions, while, literature reports a frequency of calcification in renal cell carcinoma between 8 and 22%, in studies using abdominal films and EU (IVP). This finding is of great importance when we consider that these calcifications occur particularly in malignant neoplasms. As a result of comparing these different imaging methods we have developed a better methodology for renal tumor investigation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In veterinary medicine, the same clinician usually follows an animal from birth to old age, whereas in human medicine different specialists are required. It is therefore essential that veterinarians know the normal imaging, biochemical, hematological and physical exam values for younglings, which differ significantly from those of adults of the same species. Abdominal radiographies of young animals are poorly defined due to differences in tissue constitution in relation to adults. These same factors, however, substantially improve sonographic images of the region. Nonetheless, the interpretation of B-mode sonographic findings in puppies is difficult due to the lack of information about the normal parameters in this phase of life. The objective of this study was to compile information about peculiarities of abdominal B-mode ultrasonography in puppies and kittens.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB