692 resultados para Cromo - Toxicologia
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Tesis Universidad Central, 1858.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Loca ex veterum monimentis eruta perpetuo commentario ornavit, varia experimenta et observata adjecit.
Resumo:
Hexavalent chromium is a heavy metal present in various industrial effluents, and depending on its concentration may cause irreparable damage to the environment and to humans. Facing this surrounding context, this study aimed on the application of electrochemical methods to determine and remove the hexavalent chromium (Cr6+) in simulated wastewater. To determine was applied to cathodic stripping voltammetry (CSV) using ultra trace graphite electrodes ultra trace (work), Ag/AgCl (reference) and platinum (counter electrode), the samples were complexed with 1,5- diphenylcarbazide and then subjected to analysis. The removal of Cr6+ was applied electrocoagulation process (EC) using Fe and Al electrodes. The variables that constituted the factorial design 24, applied to optimizing the EC process, were: current density (5 and 10 mA.cm-2), temperature (25 and 60 ºC), concentration (50 and 100 ppm) and agitation rate (400 and 600 RPM). Through the preliminary test it was possible the adequacy of applying the CSV for determining of Cr6+, removed during the EC process. The Fe and Al electrodes as anodes sacrifice showed satisfactory results in the EC process, however Fe favored complete removal in 30 min, whereas with Al occurred at 240 min. In the application of factorial design 24 and analysis of Response Surface Methodology was possible to optimize the EC process for removal of Cr6+ in H2SO4 solution (0.5 mol.L-1), in which the temperature, with positive effect, was the variable that presented higher statistical significance compared with other variables and interactions, while in optimizing the EC process for removal of Cr6+ in NaCl solution (0.1 mol.L-1) the current density, with positive effect, and concentration, with a negative effect were the variables that had greater statistical significance with greater statistical significance compared with other variables and interactions. The utilization of electrolytes supports NaCl and Na2SO4 showed no significant differences, however NaCl resulted in rapid improvement in Cr6+ removal kinetics and increasing the NaCl concentration provided an increase in conductivity of the solution, resulting in lower energy consumption. The wear of the electrodes evaluated in all the process of EC showed that the Al in H2SO4 solution (0.5 mol.L-1), undergoes during the process of anodization CE, then the experimental mass loss is less than the theoretical mass loss, however, the Fe in the same medium showed a loss of mass greater experimental estimated theoretically. This fact is due to a spontaneous reaction of Fe with H2SO4, and when the reaction medium was the NaCl and Na2SO4 loss experimental mass approached the theoretical mass loss. Furthermore, it was observed the energy consumption of all processes involved in this study had a low operating cost, thus enabling the application of the EC process for treating industrial effluents. The results were satisfactory, it was achieved complete removal of Cr6+ in all processes used in this study.
Resumo:
Dissertação (Mestrado em Tecnologia Nuclear)
Resumo:
The environmental pollution caused by industries has increased the concentration of pollutants in the environment, especially in water. Among the most diverse contaminants, there is the metals, who may or may not to be heavy/toxic, causing effluent of difficult treatment when in low concentrations. The search for alternative measures of wastewater effluent treatment has led to studies using phytoremediation technique through the various matrices (plant, fungi, bacteria) as means of polishing treatment to remove contaminants by means of biosorption/bioaccumulation. In order to use the phytoremediation technique for removing metals of the environmental, it have been performed bioassay with the macrophyte Pistia stratiotes. The bioassays were realized with healthy plants of P. stratiotes acclimatized in a greenhouse, at room temperature and lighting conditions during 28 days of cultivate. The cultivations were performed in glass vessels containing 1 L of the hydroponic solution with chromium (VI) in the potassium dichromate form with concentration range 0.10 to 4.90 mg L-1. The experiments were performed by Outlining Central Composite Rotational (OCCR), where the kinetics of bioaccumulation and chlorophyll a fluorescence were monitored in plants of P. stratiotes during cultivation. The collections of the samples and cultive solution were performed according to the OCCR. The chromium levels were measured in samples of P. stratiotes and the remaining solutions by the methodology of atomic absorption spectrometry by flame. The tolerance of P. stratiotes in relation to exposure to chromium (VI) was analyzed by parameters of physiological activity by means of chlorophyll a fluorescence, using the portable fluorometer PAM (Pulse Amplitude Modulation). The development of P. stratiots and their biomass were related to the time factor, while bioaccumulation capacities were strongly influenced by factors of time and chromium concentration (VI). The chlorophyll fluorescence parameters were affected by chromium and the exposure time at the bioassays. It was obtained an higher metal removal from the root in relation to the sheet, reaching a high rate of metal removal in solution. The experimental data removal kinetics were represented by kinetic models Irreversibly Langmuir, Reversible Langmuir, Pseudo-first Order and Pseudo-second Order, and the best fit for the culture solution was the Reversible Langmuir model with R² 0.993 and for the plant the best model was Pseudo-second order with R² 0.760.
Resumo:
Neste trabalho foi avaliado o processo de recobrimento de partículas de areia com quitosana utilizando a técnica dip-coating, e analisado o emprego destas partículas como recheio de uma coluna de leito fixo no processo de adsorção de cromo (VI) em solução aquosa. A quitosana foi obtida a partir de resíduos de camarão e caracterizada. O estudo avaliou a influência do tamanho das partículas e da concentração da solução de quitosana no recobrimento das partículas de areia. Foram avaliados parâmetros termodinâmicos, isotermas de equilíbrio e parâmetros relacionados ao funcionamento do leito (vazão e pH da solução, diâmetro de partícula) para o processo de adsorção de cromo (VI) em solução aquosa. No recobrimento das partículas de areia, o tamanho não teve significância na resposta, enquanto a concentração da solução de recobrimento mostrou ter grande influência sobre o resultado, sendo que a menor concentração de quitosana dentro da faixa estudada (0,5% p/v) apresentou o melhor desempenho. O processo de cura física para o recobrimento das partículas de areia mostrou melhor desempenho para a adsorção de cromo (VI) em leito fixo frente ao processo físico-químico. As análises de superfície (MEV) e de difração de raio-X (EDX) comprovaram a mudança na superfície das partículas recobertas e a presença de cromo após a adsorção. O modelo de Sips foi o que melhor representou os dados experimentais de equilíbrio, com R2 >0,99% e EMR<3,5%, sendo que a capacidade máxima de adsorção foi de 46,93 mg g-1 obtida a 298 K. O processo se mostrou espontâneo, exotérmico e favorável, com valores de -4,49 a -4,66kJ mol-1 para e energia livre de Gibbs, -5,97kJ mol-1 para a variação de entalpia e -5,17x10-3 kJ mol-1K -1 para variação de entropia. O aumento do pH diminuiu a adsorção de cromo (VI), sendo que a melhor resposta foi obtida em pH 3, sendo que o diâmetro de partícula não teve efeito significante. O estudo da vazão da solução de cromo (VI) no desempenho do leito mostrou que no menor valor (2,5 mL min-1 ) a concentração de saída do leito foi próxima a zero, mantendo-se com concentrações de saída abaixo de 20% por pelo menos 20 min. O estudo da dessorção do leito mostrou que após cinco ciclos de trabalho o leito manteve 86% da capacidade de adsorção, com taxas de recuperação do cromo no processo de dessorção maiores que 95%.
Resumo:
A presença de metais traço no ambiente está associada às fontes naturais e antropogênicas. O aumento das concentrações desses elementos pode resultar em um desequilíbrio do ecossistema tornando-se um risco potencial para o meio. O metal cromo tem seus efeitos relacionados com sua concentração e com o estado de oxidação em que se apresenta, já que seu estado trivalente é considerando essencial, enquanto que seu estado hexavalente é considerado extremamente tóxico. O objetivo deste trabalho é realizar a especiação química do cromo após ter sido realizada a revalidação analítica, englobando faixa linear de trabalho, limites de detecção e quantificação, exatidão e precisão. Este estudo é essencial tanto pela questão ambiental quanto sanitária, já que a especiação foi realizada em cinco pontos do Estuário da Lagoa dos Patos - dois na Zona Portuária e três no Saco da Mangueira, entre os meses de março e setembro de 2008 e também na Estação de Tratamento de Água que ocorreram entre os meses de janeiro e setembro de 2008. Foram realizadas determinações das frações de Cr (III) ativo, Cr (VI) e Cr (III) não ativo, por Voltametria de Redissolução Catódica. A Fração de Cromo Total foi determinada por Espectrometria de Absorção Atômica. Também foram realizadas in situ determinações dos seguintes parâmetros físicoquímicos: salinidade, pH, Eh, oxigênio dissolvido e temperatura; além dos nutrientes nitrogenados. As determinações não identificaram o metal no estado de oxidação mais tóxico (cromo hexavalente), também não foi identificada a fração de Cr (III) ativo. O metal foi identificado na forma de Cr (III) não-ativo, ou seja, na forma trivalente e complexada por ligantes naturais estáveis. As concentrações de cromo total estiveram sempre abaixo do limite estabelecido pelos órgãos reguladores competentes. Portanto, mesmo com as atividades industriais e portuárias existentes na região, não foram identificadas concentrações ou espécies de cromo que caracterizam um ambiente impactado.
Resumo:
Bogotá (Colombia) : Universidad de La Salle. Facultad de Ingeniería. Programa de Ingeniería Ambiental y Sanitaria