823 resultados para Corrosion testing and monitoring


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gill-netting and rotenoning have been used for assessing and monitoring fish stock abundance in Volta Lake. The lake and the main gear types used on it have been described. Before a gill-net sampling plan was set up, a preliminary survey was undertaken which largely determined the final form of the plan. An investigation as to whether or not the lake was being overfished concluded that it was being underfished. Commercial and experimental catch data analyses disclosed that the adults of the small species were being little utilized. Commercial sized species were also not being harvested according to their apparent proportion in the population. Production is presently fluctuating between approximately 37,000 and 40,000 tonnes. A high correlation between commercial and experimental catch was realized. Developments which have followed in the wake of stock assessment and monitoring studies include: introduction of monofilament nylon net, development of a special scoop net to permit mass harvest of clupeids after they have been attracted to light, and the design of a larger canoe which would help to extend the fishery into open water. New regulation and management policies will have to be formulated in the light of new findings before a rational exploitation of all the species can be achieved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Offshore wind capacity is expected to grow exponentially over the next decade resulting in the production of a considerable amount of renewable energy. Monopiles are currently the most popular type of foundation for supporting offshore wind turbines in shallow to medium depth waters. In this paper, the load-deformation response of a 3.8 m diameter monopile installed in soft clays when subjected to axial and lateral loading is investigated using centrifuge testing and soil pore-fluid coupled three-dimensional finite element analysis. Monopile deformation is principally assessed in terms of its lateral displacements and bending moments. Its behaviour as a short rigid pile is discussed using concepts such as its rotation at mudline and the pile depth at which pivoting occurs. © 2014 Taylor & Francis Group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mechanical properties and fracture behavior of silicon nitride (SiNx) thin film fabricated by plasma-enhanced chemical vapor deposition is reported. Plane-strain moduli, prestresses, and fracture strengths of silicon nitride thin film; deposited both oil a bare Si substrate and oil a thermally oxidized Si substrate were extracted using bulge testing combined with a refined load-deflection model of long rectangular membranes. The plane-strain modu i and prestresses of SiNx thin films have little dependence on the substrates, that is, for the bare Si substrate, they are 133 +/- 19 GPa and 178 +/- 22 MPa, respectively, while for the thermally oxidized substrate, they are 140 +/- 26 Gila and 194 +/- 34 MPa, respectively. However, the fracture strength values of SiNx films grown on the two substrates are quite different, i.e., 1.53 +/- 0.33 Gila and 3.08 +/- 0.79 GPa for the bare Si substrate a A the oxidized Si substrate, respectively. The reference stresses were computed by integrating the local stress of the membrane at the fracture over the edge, Surface, and volume of the specimens and fitted with the Weibull distribution function. For SiNx thin film produced oil the bare Si Substrate, the Volume integration gave a significantly better agreement between data and model, implying that the volume flaws re the dominant fracture origin. For SiNx thin film grown on the oxidized Si substrate, the fit quality of surface and edge integration was significantly better than the Volume integration, and the dominant surface and edge flaws could be caused by buffered HF attacking the SiNx layer during SiO2 removal. Crown Copyright (C) 2008 Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Susceptibility to stress corrosion cracking of X56 steel and its relationship with hydrogen permeation behaviour in atmospheric environment containing H2S was investigated by hydrogen permeation tests at a slow strain rate. The results show that: the fracture strain decreases with the decrease of strain rate under the same experimental conditions; the fracture strain also decreases with the increase of H2S concentration under the same strain rate, and the increased concentration of H2S has no significant effect on the hydrogen permeation in the first wet, etc. dry cycle, however has lead to increased hydrogen permeation in the later cycles. The SEM images of the fractured surfaces show clear evidences of enhanced stress corrosion cracking susceptibility by H2S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Barnes, D. P., Lee, M. H., Hardy, N. W. (1983). A control and monitoring system for multiple-sensor industrial robots. In Proc. 3rd. Int. Conf. Robot Vision and Sensory Controls, Cambridge, MA. USA., 471-479.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For high-intensity focused ultrasound (HIFU) to continue to gain acceptance for cancer treatment it is necessary to understand how the applied ultrasound interacts with gas trapped in the tissue. The presence of bubbles in the target location have been thought to be responsible for shielding the incoming pressure and increasing local heat deposition due to the bubble dynamics. We lack adequate tools for monitoring the cavitation process, due to both limited visualization methods and understanding of the underlying physics. The goal of this project was to elucidate the role of inertial cavitation in HIFU exposures in the hope of applying noise diagnostics to monitor cavitation activity and control HIFU-induced cavitation in a beneficial manner. A number of approaches were taken to understand the relationship between inertial cavitation signals, bubble heating, and bubble shielding in agar-graphite tissue phantoms. Passive cavitation detection (PCD) techniques were employed to detect inertial bubble collapses while the temperature was monitored with an embedded thermocouple. Results indicate that the broadband noise amplitude is correlated to bubble-enhanced heating. Monitoring inertial cavitation at multiple positions throughout the focal region demonstrated that bubble activity increased prefocally as it diminished near the focus. Lowering the HIFU duty cycle had the effect of maintaining a more or less constant cavitation signal, suggesting the shielding effect diminished when the bubbles had a chance to dissolve during the HIFU off-time. Modeling the effect of increasing the ambient temperature showed that bubbles do not collapse as violently at higher temperatures due to increased vapor pressure inside the bubble. Our conclusion is that inertial cavitation heating is less effective at higher temperatures and bubble shielding is involved in shifting energy deposition at the focus. The use of a diagnostic ultrasound imaging system as a PCD array was explored. Filtering out the scattered harmonics from the received RF signals resulted in a spatially- resolved inertial cavitation signal, while the amplitude of the harmonics showed a correlation with temperatures approaching the onset of boiling. The result is a new tool for detecting a broader spectrum of bubble activity and thus enhancing HIFU treatment visualization and feedback.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the design and evaluation of the REAM (Remote Electricity Actuation and Monitoring) node based around the modular Tyndall Mote platform. The REAM node enables the user to remotely actuate power to a mains power extension board while sampling the current, voltage, power and power factor of the attached load. The node contains a current transformer interfaced to an Energy Metering IC which continuously samples current and voltage. These values are periodically read from the part by a PIC24 microcontroller, which calculates the RMS current and voltage, power factor and overall power. The resultant values can then be queried wirelessly employing the Tyndall 802.15.4 compliant wireless module.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cream liqueurs manufactured by a one-step process, where alcohol was added before homogenisation, were more stable than those processed by a two -step process which involved addition of alcohol after homogenisation. Using the one-step process, it was possible to produce creaming-stable liqueurs by using one pass through a homogeniser (27.6 MPa) equipped with "liquid whirl" valves. Test procedures to characterise cream liqueurs and to predict shelf life were studied in detail. A turbidity test proved simple, rapid and sensitive for characterising particle size and homogenisation efficiency. Prediction of age thickening/gelation in cream liqueurs during incubation at 45 °C depended on the age of the sample when incubated. Samples that gelled at 45 °C may not do so at ambient temperature. Commercial cream liqueurs were similar in gross chemical composition, and unlike experimentally produced liqueurs, these did not exhibit either age-gelation at ambient or elevated temperatures. Solutions of commercial sodium caseinates from different sources varied in their calcium sensitivity. When incorporated into cream liqueurs, caseinates influenced the rate of viscosity increase, coalescence and, possibly, gelation during incubated storage. Mild heat and alcohol treatment modified the properties of caseinate used to stabilise non-alcoholic emulsions, while the presence of alcohol in emulsions was important in preventing clustering of globules. The response to added trisodium citrate varied. In many cases, addition of the recommended level (0.18%) did not prevent gelation. Addition of small amounts of NaOH with 0.18 % trisodium citrate before homogenisation was beneficial. The stage at which citrate was added during processing was critical to the degree of viscosity increase (as opposed to gelation) in the product during 45 °C incubation. The component responsible for age-gelation was present in the milk-solids non fat portion of the cream and variations in the creams used were important in the age-gelation phenomenon Results indicated that, in addition to possibly Ca++, the micellar casein portion of serum may play a role in gelation. The role of the low molecular weight surfactants, sodium stearoyl lactylate and monodiglycerides in preventing gelation, was influenced by the presence of trisodium citrate. Clustering of fat globules and age-gelation were inhibited when 0.18 % citrate was included. Inclusion of sodium stearoyl lactylate, but not monodiglycerides, reduced the extent of viscosity increase at 45 °C in citrate containing liqueurs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate relationships between institutional mistrust (systematic discrimination, organizational suspicion, and conspiracy beliefs), HIV risk behaviors, and HIV testing in a multiethnic sample of men who have sex with men (MSM), and to test whether perceived susceptibility to HIV mediates these relationships for White and ethnic minority MSM. METHOD: Participants were 394 MSM residing in Central Arizona (M age = 37 years). Three dimensions of mistrust were examined, including organizational suspicion, conspiracy beliefs, and systematic discrimination. Assessments of sexual risk behavior, HIV testing, and perceived susceptibility to HIV were made at study entry (T1) and again 6 months later (T2). RESULTS: There were no main effects of institutional mistrust dimensions or ethnic minority status on T2 risk behavior, but the interaction of systematic discrimination and conspiracy beliefs with minority status was significant such that higher levels of systematic discrimination and more conspiracy beliefs were associated with increased risk only among ethnic minority MSM. Higher levels of systematic discrimination were significantly related to lower likelihood for HIV testing, and the interaction of organizational suspicion with minority status was significant such that greater levels of organizational suspicion were related to less likelihood of having been tested for HIV among ethnic minority MSM. Perceived susceptibility did not mediate these relationships. CONCLUSION: Findings suggest that it is important to look further into the differential effects of institutional mistrust across marginalized groups, including sexual and ethnic minorities. Aspects of mistrust should be addressed in HIV prevention and counseling efforts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To evaluate pretreatment hepatitis B virus (HBV) testing, vaccination, and antiviral treatment rates in Veterans Affairs patients receiving anti-CD20 Ab for quality improvement. METHODS: We performed a retrospective cohort study using a national repository of Veterans Health Administration (VHA) electronic health record data. We identified all patients receiving anti-CD20 Ab treatment (2002-2014). We ascertained patient demographics, laboratory results, HBV vaccination status (from vaccination records), pharmacy data, and vital status. The high risk period for HBV reactivation is during anti-CD20 Ab treatment and 12 mo follow up. Therefore, we analyzed those who were followed to death or for at least 12 mo after completing anti-CD20 Ab. Pretreatment serologic tests were used to categorize chronic HBV (hepatitis B surface antigen positive or HBsAg+), past HBV (HBsAg-, hepatitis B core antibody positive or HBcAb+), resolved HBV (HBsAg-, HBcAb+, hepatitis B surface antibody positive or HBsAb+), likely prior vaccination (isolated HBsAb+), HBV negative (HBsAg-, HBcAb-), or unknown. Acute hepatitis B was defined by the appearance of HBsAg+ in the high risk period in patients who were pretreatment HBV negative. We assessed HBV antiviral treatment and the incidence of hepatitis, liver failure, and death during the high risk period. Cumulative hepatitis, liver failure, and death after anti-CD20 Ab initiation were compared by HBV disease categories and differences compared using the χ(2) test. Mean time to hepatitis peak alanine aminotransferase, liver failure, and death relative to anti-CD20 Ab administration and follow-up were also compared by HBV disease group. RESULTS: Among 19304 VHA patients who received anti-CD20 Ab, 10224 (53%) had pretreatment HBsAg testing during the study period, with 49% and 43% tested for HBsAg and HBcAb, respectively within 6 mo pretreatment in 2014. Of those tested, 2% (167/10224) had chronic HBV, 4% (326/7903) past HBV, 5% (427/8110) resolved HBV, 8% (628/8110) likely prior HBV vaccination, and 76% (6022/7903) were HBV negative. In those with chronic HBV infection, ≤ 37% received HBV antiviral treatment during the high risk period while 21% to 23% of those with past or resolved HBV, respectively, received HBV antiviral treatment. During and 12 mo after anti-CD20 Ab, the rate of hepatitis was significantly greater in those HBV positive vs negative (P = 0.001). The mortality rate was 35%-40% in chronic or past hepatitis B and 26%-31% in hepatitis B negative. In those pretreatment HBV negative, 16 (0.3%) developed acute hepatitis B of 4947 tested during anti-CD20Ab treatment and follow-up. CONCLUSION: While HBV testing of Veterans has increased prior to anti-CD20 Ab, few HBV+ patients received HBV antivirals, suggesting electronic health record algorithms may enhance health outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report covers the testing and evaluation of the airEXODUS evacuation model. airEXODUS has been developed for evacuation certification testing, crew training and aircraft design. The report demonstrates the effectiveness of the model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The corrosion of steel reinforcement bars in reinforced concrete structures exposed to severe marine environments usually is attributed to the aggressive nature of chloride ions. In some cases in practice corrosion has been observed to commence already within a few years of exposure even with considerable concrete cover to the reinforcement and apparently high quality concretes. However, there are a number of other cases in practice for which corrosion initiation took much longer, even in cases with quite modest concrete cover and modest concrete quality. Many of these structures show satisfactory long-term structural performance, despite having high levels of localized chloride concentrations at the reinforcement. This disparity was noted already more than 50 years ago, but appears still not fully explained. This paper presents a systematic overview of cases reported in the engineering and corrosion literature and considers possible reasons for these differences. Consistent with observations by others, the data show that concretes made from blast furnace cements have better corrosion durability properties. The data also strongly suggest that concretes made with limestone or non-reactive dolomite aggregates or sufficiently high levels of other forms of calcium carbonates have favourable reinforcement corrosion properties. Both corrosion initiation and the onset of significant damage are delayed. Some possible reasons for this are explored briefly.