983 resultados para Cone-bean computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Increasing age and cholesterol levels, male gender, and family history of early coronary heart disease (CHD) are associated with early onset of CHD in familial hypercholesterolemia (FH). Objective: Assess subclinical atherosclerosis by computed tomography coronary angiography (CTCA) and its association with clinical and laboratorial parameters in asymptomatic FH subjects. Methods: 102 FH subjects (36% male, 45 +/- 13 years, LDL-c 280 +/- 54 mg/dL) and 35 controls (40% male, 46 +/- 12 years, LDL-c 103 +/- 18 mg/dL) were submitted to CTCA. Plaques were divided into calcified, mixed and non-calcified; luminal stenosis was characterized as >50% obstruction. Results: FH had a greater atherosclerotic burden represented by higher number of patients with: plaques (48% vs. 14%, p = 0.0005), stenosis (19% vs. 3%, p = 0.015), segments with plaques (2.05 +/- 2.85 vs. 0.43 +/- 1.33, p = 0.0016) and calcium scores (55 perpendicular to 129 vs. 38 perpendicular to 140, p = 0.0028). After multivariate analysis, determinants of plaque presence were increasing age (OR = 2.06, for age change of 10 years, CI95%: 1.38-3.07, p < 0.001) and total cholesterol (OR = 1.86, for cholesterol change by 1 standard deviation, CI95%: 1.09-3.15, p = 0.027). Coronary calcium score was associated with the presence of stenosis (OR = 1.54; CI95%: 1.27-1.86, p < 0.001, for doubling the calcium score). Male gender was directly associated with the presence of non-calcified plaques (OR: 15.45, CI95% 1.72-138.23, p = 0.014) and inversely with calcified plaques (OR = 0.21, CI95%: 0.05-0.84, p = 0.027). Family history of early CHD was associated with the presence of mixed plaques (OR = 4.90, CI95%: 1.32-18.21, p = 0.018). Conclusions: Patients with FH had an increased burden of coronary atherosclerosis by CTCA. The burden of atherosclerosis and individual plaque subtypes differed with the presence of other associated risk factors, with age and cholesterol being most important. A coronary calcium score of zero ruled out obstructive disease in this higher risk population. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. Chronic rhinosinusitis (CRS) is a risk factor for asthma exacerbations and is associated with greater clinical severity. Discrepancies may exist between CRS clinical diagnosis and data from paranasal sinus (PS) X-ray or computed tomography (CT) scans. The objective was to compare PS involvement using low-dose CT and plain X-ray in allergic asthmatic patients with rhinitis. Methods. Patients underwent PS radiography in the frontal and mentonian positions and low-dose CT consisting of six to eight coronal scans performed on the central region of the sphenoidal, ethmoidal, maxillary, and frontal sinuses. Possible results for each sinus were a normal aspect or the presence of mucosal thickening, opacification, and/or air-fluid level. Results. Eighty-five (93.4%) of 91 study patients had radiological changes on radiography or CT. In only six (6.6%) were both tests normal. The maxillary was the most involved sinus by both methods. Simultaneous PS abnormalities were observed in 40.5% on X-ray and 56.7% on CT. For the frontal, ethmoidal, and sphenoidal sinuses, the proportion of normal results differed significantly between X-ray and CT: 80.2% versus 89%, 76.9% versus 63.7% and 96.7% versus 70.3%, respectively (p <.05). Agreement was over 70% for the maxillary and frontal sinuses. CT also provided a better diagnosis of air-fluid level changes than X-ray. Conclusions. Low-dose CT significantly showed larger number of normal PS results and diagnosed more severe PS lesions. As the determination of true sinus severity lesion impacts in asthma control, low-dose CT may replace PS plain X-ray and conventional CT to support better clinical decisions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Visceral abdominal fat has been associated to cardiovascular risk factors and coronary artery disease (CAD). Computed tomography (CT) coronary angiography is an emerging technology allowing detection of both obstructive and nonobstructive CAD adding information to clinical risk strati. cation. The aim of this study was to evaluate the association between CAD and adiposity measurements assessed clinically and by CT. We prospectively evaluated 125 consecutive subjects (57% men, age 56.0 +/- 12 years) referred to perform CT angiography. Clinical and laboratory variables were determined and CT angiography and abdominal CT were performed in a 64-slice scanner. CAD was defined as any plaque calcified or not detected by CT angiography. Visceral and subcutaneous adiposity areas were determined at different intervertebral levels. CT angiography detected CAD in 70 (56%) subjects, and no association was found with usual anthropometric adiposity measurements (waist and hip circumferences and body mass index). Otherwise, CT visceral fat areas (VFA) were significantly related to CAD. VFA T12-L1 values >= 145 cm(2) had an odds ratio of 2.85 (95% CI 1.30-6.26) and VFA L4-L5 >= 150 cm(2) had a 2.87-fold (95% CI 1.31-6.30) CAD risk. The multivariate analysis determined age and VFA T12-L1 as the only independent variables associated to CAD. Visceral fat assessed by CT is an independent marker of CAD determined by CT angiography. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The development of newer diagnostic technologies has reduced the need for invasive electroencephalographic (EEG) studies in identifying the epileptogenic zone, especially in adult patients with mesial temporal lobe epilepsy and hippocampal sclerosis (MTLE-HS). OBJECTIVE: To evaluate ictal single photon emission computed tomography (SPECT) in the evaluation and treatment of patients with MTLE-HS. METHODS: MTLE patients were randomly assigned to those with (SPECT, n = 124) and without ictal SPECT (non-SPECT, n = 116) in an intent-to-treat protocol. Primary end points were the proportion of patients with invasive EEG studies, and those offered surgery. Secondary end points were the length of hospital stay and the proportion of patients with secondarily generalized seizures (SGS) during video-EEG, postsurgical seizure outcome, and hospital cost. RESULTS: The proportion of patients offered surgery was similar in the SPECT (85%) and non-SPECT groups (81%), as well as the proportion that had invasive EEG studies (27% vs 23%). The mean duration of hospital stay was 1 day longer for the SPECT group (P < 0.001). SGS occurred in 51% of the SPECT and 26% of the non-SPECT group (P < 0.001). The cost of the presurgical evaluation was 35% higher for the SPECT compared with the non-SPECT group (P < 0.001). The proportion of patients seizure-free after surgery was similar in the SPECT (59%) compared with non-SPECT group (54%). CONCLUSION: Ictal-SPECT did not add localizing value beyond what was provided by EEG-video telemetry and structural MRI that altered the surgical decision and outcome for MTLE-HS patients. Ictal-SPECT increased hospital stay was associated with increased costs and a higher chance of SGS during video-EEG monitoring. These findings support the notion that a protocol including ictal SPECT is equivalent to one without SPECT in the presurgical evaluation of adult patients with MTLE-HS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For some surgical procedures in veterinary dentistry including exodontia, orthognathic surgery, orthopedic surgery, oncologic surgery, and for the placement of dental implants, it is important to know the accurate location of the neurovascular structures within the mandibular canal. The aim of this research was to determine the course of the mandibular canal in the mandible and its relationship with other anatomical structures in brachycephalic dogs using computerized tomography. Mandibles from 10 brachycephalic cadaver dogs were evaluated. Measurements were taken in relation to the lingual, vestibular alveolar crest, and ventral surfaces. These measurements indicated that the mandibular canal descends slightly from the mandibular foramen to the molar area, decreasing the distance of the mandibular canal from the mandibular ventral border The mandibular canal is slightly closer to the lingual surface than the vestibular surface except in the molar tooth region. The mandibular canal continues in a rostral direction occupying the ventral region of the mandibular body, reaching its maximum distance from the alveolar crest at the level of the first molar and fourth premolar teeth. In the third and fourth premolar tooth region, the mandibular canal maintains a similar distance between the vestibular and lingual borders; then, at the level of the second premolar tooth, the distance of the mandibular canal from the lingual and ventral border increases before its termination at the mental, foramen. The study reported here documents the feasibility of using CT to determine the location of the mandibular canal in relation to bony and dental parameters. Although the difference in mandible size of the group of brachycephalic dogs reported here resulted in broad ranges of measurements, it is clear that the MC course may vary between individual dogs. J Vet Dent 26(3); 156 - 163, 2009

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8 +/- 2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618 +/- 211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The aim was to verify the concordance of CT evaluation among four radiologists (two oral and maxillofacial and two medical radiologists) at the TN (tumour/node) stage and in the follow-up of oral cavity and oropharyngeal cancer patients. The study also compared differences between clinical and CT examinations in determining the TN stage. Methods: The following clinical and tomographic findings of 15 non-treated oral cavity and oropharyngeal cancer patients were compared: tumour size, bone invasion and lymph node metastases. In another 15 patients, who had previously been treated, a clinical and tomographic analysis comparison for the presence of tumoural recurrence, post-therapeutic changes in muscles and lymph node metastases was performed. The concordances of tomographic evaluation between the radiologists were analysed using the kappa index. Results: Significant agreement was verified between all radiologists for the T stage, but not for the N stage. In the group of treated patients, CT disclosed post-therapeutic changes in muscles, tumour recurrence and lymph node metastases, but no concordance for the detection of lymph node metastases was found between radiologists. In the first group, for all radiologists, no concordance was demonstrated between clinical and tomographic staging. CT was effective for delimitating advanced lesions and for detecting lymph node involvement in N0 stage patients. CT revealed two cases of bone invasion not clinically detected. Conclusions: Interprofessional relationships must be stimulated to improve diagnoses, and to promote a multidisciplinary approach to oral cavity and oropharyngeal cancer. Although CT was important in the diagnosis and follow-up of cancer patients, differences between medical and dental analyses should be acknowledged. Dentomaxillofacial Radiology (2010) 39, 140-148. doi: 10.1259/dmfr/69910245

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the area and volume of bone available for grafting in a donor retromolar region using computed tomography (CT). Materials and Methods: Ten patients previously scanned by multislice CT were selected for evaluation. Images from partially and completely dentate patients at least 18 years of age were included in the study; those from patients with impacted or erupted third molars or intrabony lesions in the study area were not included. Computer software with appropriate tools was used to handle the images. Two calibrated observers made measurements separately. Safety margins in relation to the lingual cortex, the base of mandible, and the alveolar canal were established in each cross-section of the CTs. Measurements were done by using cross-sectional views, and the results were calculated after three-dimensional reconstruction, providing area and volume data. Results: The mean area of bone available for grafting was 8.12 cm(2) ( range, 0.00 to 13.60 cm(2)) and 8.32 cm(2) ( range, 0.00 to 14.30 cm(2)) for observers 1 and 2, respectively. Mean available bone volume for grafting was 0.79 cm(3) ( range, 0.00 to 1.50 cm(3)) for observer 1 and 0.85 cm(3) ( range, 0.00 to 1.60 cm(3)) for observer 2. Interobserver analysis showed substantial agreement. Conclusion: The retromolar region showed a wide variety of anatomic differences among patients. Three-dimensional multislice CT allows reproducible measurements of the area and volume of the retromolar region. Int J Oral Maxillofac Implants 2010; 25: 374-378

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tumoural and cystic lesions are common findings in the daily practice of dental professionals and maxillofacial radiologists. However, simultaneous lesions are rare and represent a diagnostic challenge to overcome. Among tumoural pathologies, odontomas are the most common odontogenic tumour of the jaws. Cystic transformation or development from the tumoural capsule are well recognized in situations such as ameloblastomas originated from a dentigerous cyst. Otherwise, despite literature reports, dentigerous cysts arising from odontomas are very rare and could lead to misdiagnosis. Here, we report a case of a complex odontoma associated with a dentigerous cyst in the maxillary sinus, focussing on the tomographic features and a differential imaging approach to the diagnosis of these lesions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the root canal preparation in flat-oval canals treated with either rotary or self-adjusting file (SAF) by using micro-tomography analysis. Methods: Forty mandibular incisors were scanned before and after root canal instrumentation with rotary instruments (n = 20) or SAF (n = 20). Changes in canal volume, surface area, and cross-sectional geometry were compared with preoperative values. Data were compared by independent sample t test and chi(2) test between groups and paired sample t test within the group (alpha = 0.05). Results: Overall, area, perimeter, roundness, and major and minor diameters revealed no statistical difference between groups (P > .05). In the coronal third, percentage of prepared root canal walls and mean increases of volume and area were significantly higher with SAF (92.0%, 1.44 +/- 0.49 mm(3), 0.40 +/- 0.14 mm(2), respectively) than rotary instrumentation (62.0%, 0.81 +/- 0.45 mm(3), 0.23 +/- 0.15 mm2, respectively) (P < .05). SAF removed dentin layer from all around the canal, whereas rotary instrumentation showed substantial untouched areas. Conclusions: In the coronal third, mean increases of area and volume of the canal as well as the percentage of prepared walls were significantly higher with SAF than with rotary instrumentation. By using SAF instruments, flat-oval canals were homogenously and circumferentially prepared. The size of the SAF preparation in the apical third of the canal was equivalent to those prepared with #40 rotary file with a 0.02 taper. (J Endod 2011;37:1002-1007)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>Aim To investigate the internal and external anatomy of extracted human mandibular canines with two roots and two distinct canals using micro-computed tomography (mu CT). Methodology Fourteen two-rooted human mandibular canines were scanned using a high-resolution mu CT system (SkyScan 1174v2; SkyScan N.V., Kontich, Belgium). The images were processed to evaluate the size of the roots, the furcation regions, the presence of accessory canals, the mean distances between several anatomical landmarks, the position of the apical foramina, the direction of root curvatures, the cross-sectional appearances (SMI index), the volume and surface areas of the root canals. Results Root bifurcation was located in both apical (44%, n = 6) and middle (58%, n = 8) thirds of the root. The size of the buccal and lingual roots was similar in 29% of the sample. From a buccal view, no curvature towards the lingual or buccal direction occurred in either roots. From a proximal view, no straight lingual root occurred. In both views, S-shaped roots were found in 21% of the specimens. Location of the apical foramen varied considerably, tending to the mesio-buccal aspect of both roots. Lateral and furcation canals were observed mostly in the cervical third in 29% and 65% of the sample, respectively. The structure model index (SMI) index ranged from 1.87 to 3.86, with a mean value of 2.93 +/- 0.46. Mean volume and area of the root canals were 11.52 +/- 3.44 mm3 and 71.16 +/- 11.83 mm2, respectively. Conclusions The evaluation of two-rooted mandibular canines revealed that bifurcations occurred in the apical and middle third. S-shaped roots were found in 21% of the specimens. Mean volume, surface area and SMI index of the root canals were 11.52 mm3, 71.16 mm2 and 2.93, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eight patients with heterozygous familial hypercholesterolemia who received combined long-term low-density lipoprotein apheresis and high-dose statin therapy showed a significant decrease in volume of coronary calcium over a period of 29 months as measured by, computed tomography. This suggests that the effects of aggressive lipid-lowering therapy can be assessed non-invasively and may be used as surrogate end points when testing new therapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.