928 resultados para Computer input-output equipment
Resumo:
Includes bibliographical references.
Resumo:
Tables.
Resumo:
"July 1980".
Resumo:
Mode of access: Internet.
Resumo:
"May 1986."
Resumo:
"ST/STAT/CONF.10/L.11 & Add. 1."
Resumo:
Mode of access: Internet.
Resumo:
This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.
Resumo:
This thesis investigates how people select items from a computer display using the mouse input device. The term computer mouse refers to a class of input devices which share certain features, but these may have different characteristics which influence the ways in which people use the device. Although task completion time is one of the most commonly used performance measures for input device evaluation, there is no consensus as to its definition. Furthermore most mouse studies fail to provide adequate assurances regarding its correct measurement.Therefore precise and accurate timing software were developed which permitted the recording of movement data which by means of automated analysis yielded the device movements made. Input system gain, an important task parameter, has been poorly defined and misconceptualized in most previous studies. The issue of gain has been clarified and investigated within this thesis. Movement characteristics varied between users and within users, even for the same task conditions. The variables of target size, movement amplitude, and experience exerted significant effects on performance. Subjects consistently undershot the target area. This may be a consequence of the particular task demands. Although task completion times indicated that mouse performance had stabilized after 132 trials the movement traces, even of very experienced users, indicated that there was still considerable room for improvement in performance, as indicated by the proportion of poorly made movements. The mouse input device was suitable for older novice device users, but they took longer to complete the experimental trials. Given the diversity and inconsistency of device movements, even for the same task conditions, caution is urged when interpreting averaged grouped data. Performance was found to be sensitive to; task conditions, device implementations, and experience in ways which are problematic for the theoretical descriptions of device movement, and limit the generalizability of such findings within this thesis.
Resumo:
Astrocytes in the somatosensory ventrobasal (VB) thalamus of rats respond to glutamatergic synaptic input with metabotropic glutamate receptor (mGluR) mediated intracellular calcium ([Ca²?](i)) elevations. Astrocytes in the VB thalamus also release the gliotransmitter (GT) glutamate in a Ca²?-dependent manner. The tripartite synapse hypothesis posits that astrocytic [Ca²?](i) elevations resulting from synaptic input releases gliotransmitters that then feedback to modify the synapse. Understanding the dynamics of this process and the conditions under which it occurs are therefore important steps in elucidating the potential roles and impact of GT release in particular brain activities. In this study, we investigated the relationship between VB thalamus afferent synaptic input and astrocytic glutamate release by recording N-methyl-D-aspartate (NMDA) receptor-mediated slow inward currents (SICs) elicited in neighboring neurons. We found that Lemniscal or cortical afferent stimulation, which can elicit astrocytic [Ca²?](i) elevations, do not typically result in the generation of SICs in thalamocortical (TC) neurons. Rather, we find that the spontaneous emergence of SICs is largely resistant to acute afferent input. The frequency of SICs, however, is correlated to long-lasting afferent activity. In contrast to short-term stimulus-evoked GT release effects reported in other brain areas, astrocytes in the VB thalamus do not express a straightforward input-output relationship for SIC generation but exhibit integrative characteristics.
Resumo:
While conventional Data Envelopment Analysis (DEA) models set targets for each operational unit, this paper considers the problem of input/output reduction in a centralized decision making environment. The purpose of this paper is to develop an approach to input/output reduction problem that typically occurs in organizations with a centralized decision-making environment. This paper shows that DEA can make an important contribution to this problem and discusses how DEA-based model can be used to determine an optimal input/output reduction plan. An application in banking sector with limitation in IT investment shows the usefulness of the proposed method.