969 resultados para Complete blood count


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O ENH é séria intercorrência aguda ou subaguda que acomete pacientes das formas dimorfa-virchowiana e virchowiana da classificação de Ridley e Jopling. Neste estudo, foi utilizada uma droga imunorreguladora, a ciclosporina A, com o propósito de avaliar a eficácia nesta reação, cujo tratamento depende de medicamentos como a talidomida, que tem contra-indicações formais e corticóides, que provocam dependência, entre outros danos. Foram selecionados dez doentes de ENH com sintomas sistêmicos; todos haviam passado por vários episódios desta reação e faziam uso contínuo e prolongado de prednisona em doses elevadas e ocasionalmente, de talidomida. Os pacientes tomaram ciclosporina A em doses de 3-5 mg/kg/dia durante um período de 90 dias. Realizaram exames laboratoriais nos dias zero, 150 e 600 de uso da ciclosporina A e também o histopatológico das lesões de ENH (antes do tratamento e com 60 dias). Os exames laboratoriais solicitados foram: hemograma e leucograma; TGO; TGP: uréia e creatinina. Detectou-se leucocitose em graus entre moderado e elevado em 70% dos casos, mas evoluiu para leucocitose leve até o término do acompanhamento na mesma percentagem dos doentes. O exame bioquímico não mostrou alterações significantes, com exceção da elevação da TGO em um caso, da TGP em outro, além de dois pacientes que mostraram aumento da uréia e creatinina, mas que posteriormente, normalizaram sem precisar de medidas adicionais. Os achados histológicos encontrados no primeiro exame foram representados em 40% dos doentes, por dermatite granulomatosa e em 30%, por dermatite nodular. Na segunda análise, houve mudança para dermatite perivascular superficial e profunda em 50% dos casos e para paniculite septal em 20%; isto denota melhora histológica compatível com a melhora dos sintomas verificada nos primeiros quinze dias de terapêutica. A ação da ciclosporina A se revelou benéfica, principalmente na sintomatologia sistêmica, com exceção dos casos que se acompanhavam de neurite; desta forma, a ciclosporina A pode ser uma opção para a melhoria clínica das reações hansênicas tipo 11.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effects of dimethyl sulfoxide (DMSO) treatment on aspects of renal function, serum profile, total blood count parameters and clinical condition of health or chronic kidney disease (CKD) dogs. The evaluations were done before, during and after the administration of DMSO 10% at a dose of 0.5g kg-1, each 24h, for three days. DMSO resulted in some adverse effects in both healthy and CKD dogs, however the effects were more frequent and worse in CKD dogs. Despite these adverse effects, both groups don't have contraindications to use the drug in a short time. The severity of adverse effects related to the DMSO and its possible association with death in stage 4 CKD dogs, are contraindications for the drug in this group of patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it's more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)